CVE-2011-4535 (GCVE-0-2011-4535)
Vulnerability from cvelistv5 – Published: 2012-04-03 01:00 – Updated: 2024-09-17 00:50
VLAI
EPSS
VEX
Summary
Buffer overflow in TurboPower Abbrevia before 4.0, as used in ScadaTEC ScadaPhone 5.3.11.1230 and earlier, ScadaTEC ModbusTagServer 4.1.1.81 and earlier, and other products, allows remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via a crafted ZIP file.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| http://www.us-cert.gov/control_systems/pdf/ICSA-1… | x_refsource_MISC |
| http://sourceforge.net/projects/tpabbrevia/files/… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-07T00:09:18.767Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-362-01.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://sourceforge.net/projects/tpabbrevia/files/Abbrevia%204.0.zip/download"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Buffer overflow in TurboPower Abbrevia before 4.0, as used in ScadaTEC ScadaPhone 5.3.11.1230 and earlier, ScadaTEC ModbusTagServer 4.1.1.81 and earlier, and other products, allows remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via a crafted ZIP file."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2012-04-03T01:00:00.000Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-362-01.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://sourceforge.net/projects/tpabbrevia/files/Abbrevia%204.0.zip/download"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2011-4535",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Buffer overflow in TurboPower Abbrevia before 4.0, as used in ScadaTEC ScadaPhone 5.3.11.1230 and earlier, ScadaTEC ModbusTagServer 4.1.1.81 and earlier, and other products, allows remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via a crafted ZIP file."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-362-01.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-362-01.pdf"
},
{
"name": "http://sourceforge.net/projects/tpabbrevia/files/Abbrevia%204.0.zip/download",
"refsource": "MISC",
"url": "http://sourceforge.net/projects/tpabbrevia/files/Abbrevia%204.0.zip/download"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2011-4535",
"datePublished": "2012-04-03T01:00:00.000Z",
"dateReserved": "2011-11-22T00:00:00.000Z",
"dateUpdated": "2024-09-17T00:50:42.593Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2011-4535",
"date": "2026-07-13",
"epss": "0.27003",
"percentile": "0.97809"
},
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:craig_peterson:turbopower_abbrevia:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"3.05\", \"matchCriteriaId\": \"815BD4A7-574B-47BF-AD7C-ABD26411DE44\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:scadatec:modbustagserver:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"4.1.1.81\", \"matchCriteriaId\": \"5ADCC6BC-AEAC-4E43-B36B-2B1FF1DBC00B\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:scadatec:scadaphone:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"5.3.11.1230\", \"matchCriteriaId\": \"C41B9C82-D7B1-44EC-A379-01F9EDFCF0F6\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Buffer overflow in TurboPower Abbrevia before 4.0, as used in ScadaTEC ScadaPhone 5.3.11.1230 and earlier, ScadaTEC ModbusTagServer 4.1.1.81 and earlier, and other products, allows remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via a crafted ZIP file.\"}, {\"lang\": \"es\", \"value\": \"Desbordamiento de b\\u00fafer en TurboPower Abbrevia anteriores a v4.0, como el usado en ScadaTEC ScadaPhone v5.3.11.1230 y anteriores, ScadaTEC ModbusTagServer v4.1.1.81 y anteriores, y otros productos, permite a atacantes remotos provocar una denegaci\\u00f3n de servicio, (ca\\u00edda de la aplicaci\\u00f3n) o posiblemente ejecutar comandos a trav\\u00e9s de un fichero ZIP manipulado.\"}]",
"id": "CVE-2011-4535",
"lastModified": "2024-11-21T01:32:29.790",
"metrics": "{\"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:P/I:P/A:P\", \"baseScore\": 6.8, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
"published": "2012-04-03T03:44:36.117",
"references": "[{\"url\": \"http://sourceforge.net/projects/tpabbrevia/files/Abbrevia%204.0.zip/download\", \"source\": \"cret@cert.org\", \"tags\": [\"Patch\"]}, {\"url\": \"http://www.us-cert.gov/control_systems/pdf/ICSA-11-362-01.pdf\", \"source\": \"cret@cert.org\", \"tags\": [\"US Government Resource\"]}, {\"url\": \"http://sourceforge.net/projects/tpabbrevia/files/Abbrevia%204.0.zip/download\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\"]}, {\"url\": \"http://www.us-cert.gov/control_systems/pdf/ICSA-11-362-01.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"US Government Resource\"]}]",
"sourceIdentifier": "cret@cert.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-119\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2011-4535\",\"sourceIdentifier\":\"cret@cert.org\",\"published\":\"2012-04-03T03:44:36.117\",\"lastModified\":\"2026-04-29T01:13:23.040\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Buffer overflow in TurboPower Abbrevia before 4.0, as used in ScadaTEC ScadaPhone 5.3.11.1230 and earlier, ScadaTEC ModbusTagServer 4.1.1.81 and earlier, and other products, allows remote attackers to cause a denial of service (application crash) or possibly execute arbitrary code via a crafted ZIP file.\"},{\"lang\":\"es\",\"value\":\"Desbordamiento de b\u00fafer en TurboPower Abbrevia anteriores a v4.0, como el usado en ScadaTEC ScadaPhone v5.3.11.1230 y anteriores, ScadaTEC ModbusTagServer v4.1.1.81 y anteriores, y otros productos, permite a atacantes remotos provocar una denegaci\u00f3n de servicio, (ca\u00edda de la aplicaci\u00f3n) o posiblemente ejecutar comandos a trav\u00e9s de un fichero ZIP manipulado.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"baseScore\":6.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:craig_peterson:turbopower_abbrevia:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"3.05\",\"matchCriteriaId\":\"815BD4A7-574B-47BF-AD7C-ABD26411DE44\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:scadatec:modbustagserver:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.1.1.81\",\"matchCriteriaId\":\"5ADCC6BC-AEAC-4E43-B36B-2B1FF1DBC00B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:scadatec:scadaphone:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"5.3.11.1230\",\"matchCriteriaId\":\"C41B9C82-D7B1-44EC-A379-01F9EDFCF0F6\"}]}]}],\"references\":[{\"url\":\"http://sourceforge.net/projects/tpabbrevia/files/Abbrevia%204.0.zip/download\",\"source\":\"cret@cert.org\",\"tags\":[\"Patch\"]},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-11-362-01.pdf\",\"source\":\"cret@cert.org\",\"tags\":[\"US Government Resource\"]},{\"url\":\"http://sourceforge.net/projects/tpabbrevia/files/Abbrevia%204.0.zip/download\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\"]},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-11-362-01.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"US Government Resource\"]}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…