Summary
The GENESIS32 IcoSetServer ActiveX control in ICONICS GENESIS32 9.21 and BizViz 9.21 configures the trusted zone on the basis of user input, which allows remote attackers to execute arbitrary code via a crafted web site, related to a "Workbench32/WebHMI component SetTrustedZone Policy vulnerability."
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-07T00:23:39.868Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-182-01.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The GENESIS32 IcoSetServer ActiveX control in ICONICS GENESIS32 9.21 and BizViz 9.21 configures the trusted zone on the basis of user input, which allows remote attackers to execute arbitrary code via a crafted web site, related to a \"Workbench32/WebHMI component SetTrustedZone Policy vulnerability.\""
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2012-04-18T17:00:00Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-182-01.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2011-5088",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The GENESIS32 IcoSetServer ActiveX control in ICONICS GENESIS32 9.21 and BizViz 9.21 configures the trusted zone on the basis of user input, which allows remote attackers to execute arbitrary code via a crafted web site, related to a \"Workbench32/WebHMI component SetTrustedZone Policy vulnerability.\""
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-182-01.pdf",
              "refsource": "MISC",
              "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-182-01.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2011-5088",
    "datePublished": "2012-04-18T17:00:00Z",
    "dateReserved": "2012-04-18T00:00:00Z",
    "dateUpdated": "2024-09-17T04:18:54.223Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:iconics:bizviz:9.21:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0B4F2D10-A4DD-4C7C-A5A8-BEDC23A413C2\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:iconics:genesis32:9.21:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7CDD1388-8FBF-4B3E-854E-B68D3EB6569B\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"The GENESIS32 IcoSetServer ActiveX control in ICONICS GENESIS32 9.21 and BizViz 9.21 configures the trusted zone on the basis of user input, which allows remote attackers to execute arbitrary code via a crafted web site, related to a \\\"Workbench32/WebHMI component SetTrustedZone Policy vulnerability.\\\"\"}, {\"lang\": \"es\", \"value\": \"El control ActiveX GENESIS32 IcoSetServer en ICONICS GENESIS32 v9.21 y BizViz v9.21 configura la zona de confianza sobre la base de datos del usuario, lo que permite a atacantes remotos ejecutar c\\u00f3digo arbitrario a trav\\u00e9s de un sitio web modificado, relaci\\u00f3nado con una \\\"Workbench32/WebHMI component SetTrustedZone Policy vulnerability.\\\"\"}]",
      "id": "CVE-2011-5088",
      "lastModified": "2024-11-21T01:33:36.377",
      "metrics": "{\"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:C/I:C/A:C\", \"baseScore\": 9.3, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 8.6, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
      "published": "2012-04-18T17:55:01.167",
      "references": "[{\"url\": \"http://www.us-cert.gov/control_systems/pdf/ICSA-11-182-01.pdf\", \"source\": \"cve@mitre.org\", \"tags\": [\"US Government Resource\"]}, {\"url\": \"http://www.us-cert.gov/control_systems/pdf/ICSA-11-182-01.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"US Government Resource\"]}]",
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-Other\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2011-5088\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2012-04-18T17:55:01.167\",\"lastModified\":\"2025-04-11T00:51:21.963\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The GENESIS32 IcoSetServer ActiveX control in ICONICS GENESIS32 9.21 and BizViz 9.21 configures the trusted zone on the basis of user input, which allows remote attackers to execute arbitrary code via a crafted web site, related to a \\\"Workbench32/WebHMI component SetTrustedZone Policy vulnerability.\\\"\"},{\"lang\":\"es\",\"value\":\"El control ActiveX GENESIS32 IcoSetServer en ICONICS GENESIS32 v9.21 y BizViz v9.21 configura la zona de confianza sobre la base de datos del usuario, lo que permite a atacantes remotos ejecutar c\u00f3digo arbitrario a trav\u00e9s de un sitio web modificado, relaci\u00f3nado con una \\\"Workbench32/WebHMI component SetTrustedZone Policy vulnerability.\\\"\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:C/I:C/A:C\",\"baseScore\":9.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.6,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-Other\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:iconics:bizviz:9.21:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0B4F2D10-A4DD-4C7C-A5A8-BEDC23A413C2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:iconics:genesis32:9.21:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7CDD1388-8FBF-4B3E-854E-B68D3EB6569B\"}]}]}],\"references\":[{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-11-182-01.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"US Government Resource\"]},{\"url\":\"http://www.us-cert.gov/control_systems/pdf/ICSA-11-182-01.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"US Government Resource\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…