CVE-2013-10003 (GCVE-0-2013-10003)
Vulnerability from cvelistv5 – Published: 2022-05-24 15:30 – Updated: 2025-04-15 14:38
VLAI?
Title
Telecommunication Software SAMwin Contact Center Suite Database SAMwinLIBVB.dll getCurrentDBVersion sql injection
Summary
A vulnerability classified as critical has been found in Telecommunication Software SAMwin Contact Center Suite 5.1. This affects the function getCurrentDBVersion in the library SAMwinLIBVB.dll of the database handler. The manipulation leads to sql injection. The exploit has been disclosed to the public and may be used. Upgrading to version 6.2 is able to address this issue. It is recommended to upgrade the affected component.
Severity ?
6.5 (Medium)
CWE
- CWE-89 - SQL Injection
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Telecommunication Software | SAMwin Contact Center Suite |
Affected:
5.1
|
Credits
Tobias Ospelt/Max Moser
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T18:09:17.213Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.modzero.ch/advisories/MZ-13-06_SAMwin_Architectural_Issues.txt"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://vuldb.com/?id.12789"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2013-10003",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-14T16:58:45.846967Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-15T14:38:59.503Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SAMwin Contact Center Suite",
"vendor": "Telecommunication Software",
"versions": [
{
"status": "affected",
"version": "5.1"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Tobias Ospelt/Max Moser"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability classified as critical has been found in Telecommunication Software SAMwin Contact Center Suite 5.1. This affects the function getCurrentDBVersion in the library SAMwinLIBVB.dll of the database handler. The manipulation leads to sql injection. The exploit has been disclosed to the public and may be used. Upgrading to version 6.2 is able to address this issue. It is recommended to upgrade the affected component."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89 SQL Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-24T15:30:29.000Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.modzero.ch/advisories/MZ-13-06_SAMwin_Architectural_Issues.txt"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://vuldb.com/?id.12789"
}
],
"title": "Telecommunication Software SAMwin Contact Center Suite Database SAMwinLIBVB.dll getCurrentDBVersion sql injection",
"x_generator": "vuldb.com",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cna@vuldb.com",
"ID": "CVE-2013-10003",
"REQUESTER": "cna@vuldb.com",
"STATE": "PUBLIC",
"TITLE": "Telecommunication Software SAMwin Contact Center Suite Database SAMwinLIBVB.dll getCurrentDBVersion sql injection"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SAMwin Contact Center Suite",
"version": {
"version_data": [
{
"version_value": "5.1"
}
]
}
}
]
},
"vendor_name": "Telecommunication Software"
}
]
}
},
"credit": "Tobias Ospelt/Max Moser",
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability classified as critical has been found in Telecommunication Software SAMwin Contact Center Suite 5.1. This affects the function getCurrentDBVersion in the library SAMwinLIBVB.dll of the database handler. The manipulation leads to sql injection. The exploit has been disclosed to the public and may be used. Upgrading to version 6.2 is able to address this issue. It is recommended to upgrade the affected component."
}
]
},
"generator": "vuldb.com",
"impact": {
"cvss": {
"baseScore": "6.5",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-89 SQL Injection"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.modzero.ch/advisories/MZ-13-06_SAMwin_Architectural_Issues.txt",
"refsource": "MISC",
"url": "http://www.modzero.ch/advisories/MZ-13-06_SAMwin_Architectural_Issues.txt"
},
{
"name": "https://vuldb.com/?id.12789",
"refsource": "MISC",
"url": "https://vuldb.com/?id.12789"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2013-10003",
"datePublished": "2022-05-24T15:30:29.000Z",
"dateReserved": "2022-05-24T00:00:00.000Z",
"dateUpdated": "2025-04-15T14:38:59.503Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:telecomsoftware:samwin_agent:5.01.19.06:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"277DED3E-2806-4FDC-95ED-FC3166AAE8DE\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:telecomsoftware:samwin_contact_center:5.1:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E5873B41-8E61-4AFB-842A-903ACF22B5AC\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability classified as critical has been found in Telecommunication Software SAMwin Contact Center Suite 5.1. This affects the function getCurrentDBVersion in the library SAMwinLIBVB.dll of the database handler. The manipulation leads to sql injection. The exploit has been disclosed to the public and may be used. Upgrading to version 6.2 is able to address this issue. It is recommended to upgrade the affected component.\"}, {\"lang\": \"es\", \"value\": \"Se ha encontrado una vulnerabilidad clasificada como cr\\u00edtica en Telecommunication Software SAMwin Contact Center Suite versi\\u00f3n 5.1. Afecta a la funci\\u00f3n getCurrentDBVersion de la biblioteca SAMwinLIBVB.dll del manejador de la base de datos. La manipulaci\\u00f3n conlleva a una inyecci\\u00f3n sql. La explotaci\\u00f3n ha sido divulgada al p\\u00fablico y puede ser usado. La actualizaci\\u00f3n a versi\\u00f3n 6.2 puede abordar este problema. Es recomendado actualizar el componente afectado\"}]",
"id": "CVE-2013-10003",
"lastModified": "2024-11-21T01:48:38.493",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cna@vuldb.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N\", \"baseScore\": 6.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 2.5}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:P/A:P\", \"baseScore\": 7.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2022-05-24T16:15:07.437",
"references": "[{\"url\": \"http://www.modzero.ch/advisories/MZ-13-06_SAMwin_Architectural_Issues.txt\", \"source\": \"cna@vuldb.com\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://vuldb.com/?id.12789\", \"source\": \"cna@vuldb.com\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"http://www.modzero.ch/advisories/MZ-13-06_SAMwin_Architectural_Issues.txt\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://vuldb.com/?id.12789\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}]",
"sourceIdentifier": "cna@vuldb.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"cna@vuldb.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-89\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-89\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2013-10003\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2022-05-24T16:15:07.437\",\"lastModified\":\"2024-11-21T01:48:38.493\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability classified as critical has been found in Telecommunication Software SAMwin Contact Center Suite 5.1. This affects the function getCurrentDBVersion in the library SAMwinLIBVB.dll of the database handler. The manipulation leads to sql injection. The exploit has been disclosed to the public and may be used. Upgrading to version 6.2 is able to address this issue. It is recommended to upgrade the affected component.\"},{\"lang\":\"es\",\"value\":\"Se ha encontrado una vulnerabilidad clasificada como cr\u00edtica en Telecommunication Software SAMwin Contact Center Suite versi\u00f3n 5.1. Afecta a la funci\u00f3n getCurrentDBVersion de la biblioteca SAMwinLIBVB.dll del manejador de la base de datos. La manipulaci\u00f3n conlleva a una inyecci\u00f3n sql. La explotaci\u00f3n ha sido divulgada al p\u00fablico y puede ser usado. La actualizaci\u00f3n a versi\u00f3n 6.2 puede abordar este problema. Es recomendado actualizar el componente afectado\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":2.5},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:telecomsoftware:samwin_agent:5.01.19.06:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"277DED3E-2806-4FDC-95ED-FC3166AAE8DE\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:telecomsoftware:samwin_contact_center:5.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E5873B41-8E61-4AFB-842A-903ACF22B5AC\"}]}]}],\"references\":[{\"url\":\"http://www.modzero.ch/advisories/MZ-13-06_SAMwin_Architectural_Issues.txt\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?id.12789\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"http://www.modzero.ch/advisories/MZ-13-06_SAMwin_Architectural_Issues.txt\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?id.12789\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"http://www.modzero.ch/advisories/MZ-13-06_SAMwin_Architectural_Issues.txt\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}, {\"url\": \"https://vuldb.com/?id.12789\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-06T18:09:17.213Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2013-10003\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-14T16:58:45.846967Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-14T16:58:47.357Z\"}}], \"cna\": {\"title\": \"Telecommunication Software SAMwin Contact Center Suite Database SAMwinLIBVB.dll getCurrentDBVersion sql injection\", \"credits\": [{\"lang\": \"en\", \"value\": \"Tobias Ospelt/Max Moser\"}], \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N\", \"integrityImpact\": \"LOW\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"LOW\"}}], \"affected\": [{\"vendor\": \"Telecommunication Software\", \"product\": \"SAMwin Contact Center Suite\", \"versions\": [{\"status\": \"affected\", \"version\": \"5.1\"}]}], \"references\": [{\"url\": \"http://www.modzero.ch/advisories/MZ-13-06_SAMwin_Architectural_Issues.txt\", \"tags\": [\"x_refsource_MISC\"]}, {\"url\": \"https://vuldb.com/?id.12789\", \"tags\": [\"x_refsource_MISC\"]}], \"x_generator\": \"vuldb.com\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability classified as critical has been found in Telecommunication Software SAMwin Contact Center Suite 5.1. This affects the function getCurrentDBVersion in the library SAMwinLIBVB.dll of the database handler. The manipulation leads to sql injection. The exploit has been disclosed to the public and may be used. Upgrading to version 6.2 is able to address this issue. It is recommended to upgrade the affected component.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-89\", \"description\": \"CWE-89 SQL Injection\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2022-05-24T15:30:29.000Z\"}, \"x_legacyV4Record\": {\"credit\": \"Tobias Ospelt/Max Moser\", \"impact\": {\"cvss\": {\"version\": \"3.1\", \"baseScore\": \"6.5\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N\"}}, \"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"5.1\"}]}, \"product_name\": \"SAMwin Contact Center Suite\"}]}, \"vendor_name\": \"Telecommunication Software\"}]}}, \"data_type\": \"CVE\", \"generator\": \"vuldb.com\", \"references\": {\"reference_data\": [{\"url\": \"http://www.modzero.ch/advisories/MZ-13-06_SAMwin_Architectural_Issues.txt\", \"name\": \"http://www.modzero.ch/advisories/MZ-13-06_SAMwin_Architectural_Issues.txt\", \"refsource\": \"MISC\"}, {\"url\": \"https://vuldb.com/?id.12789\", \"name\": \"https://vuldb.com/?id.12789\", \"refsource\": \"MISC\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"A vulnerability classified as critical has been found in Telecommunication Software SAMwin Contact Center Suite 5.1. This affects the function getCurrentDBVersion in the library SAMwinLIBVB.dll of the database handler. The manipulation leads to sql injection. The exploit has been disclosed to the public and may be used. Upgrading to version 6.2 is able to address this issue. It is recommended to upgrade the affected component.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"CWE-89 SQL Injection\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2013-10003\", \"STATE\": \"PUBLIC\", \"TITLE\": \"Telecommunication Software SAMwin Contact Center Suite Database SAMwinLIBVB.dll getCurrentDBVersion sql injection\", \"ASSIGNER\": \"cna@vuldb.com\", \"REQUESTER\": \"cna@vuldb.com\"}}}}",
"cveMetadata": "{\"cveId\": \"CVE-2013-10003\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-15T14:38:59.503Z\", \"dateReserved\": \"2022-05-24T00:00:00.000Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2022-05-24T15:30:29.000Z\", \"assignerShortName\": \"VulDB\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…