CVE-2013-2782 (GCVE-0-2013-2782)
Vulnerability from cvelistv5 – Published: 2013-08-28 01:00 – Updated: 2024-09-16 16:22
VLAI?
Summary
Schneider Electric Trio J-Series License Free Ethernet Radio with firmware 3.6.0 through 3.6.3 uses the same AES encryption key across different customers' installations, which makes it easier for remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T15:44:33.682Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-234-01"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.schneider-electric.com/download/ww/en/file/141141292-SEVD-2013-143-01.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Schneider Electric Trio J-Series License Free Ethernet Radio with firmware 3.6.0 through 3.6.3 uses the same AES encryption key across different customers\u0027 installations, which makes it easier for remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-08-28T01:00:00Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-234-01"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.schneider-electric.com/download/ww/en/file/141141292-SEVD-2013-143-01.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2013-2782",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Schneider Electric Trio J-Series License Free Ethernet Radio with firmware 3.6.0 through 3.6.3 uses the same AES encryption key across different customers\u0027 installations, which makes it easier for remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-13-234-01",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-234-01"
},
{
"name": "http://www.schneider-electric.com/download/ww/en/file/141141292-SEVD-2013-143-01.pdf",
"refsource": "CONFIRM",
"url": "http://www.schneider-electric.com/download/ww/en/file/141141292-SEVD-2013-143-01.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2013-2782",
"datePublished": "2013-08-28T01:00:00Z",
"dateReserved": "2013-04-11T00:00:00Z",
"dateUpdated": "2024-09-16T16:22:35.646Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:h:schneider-electric:tburjr900:00002dh0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3689A9D3-40FB-4135-A9D3-DFC7AFE7B10B\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:h:schneider-electric:tburjr900:00002eh0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A92E024D-02C0-4B76-8352-ED5357DE34CA\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:h:schneider-electric:tburjr900:01002dh0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"816CA3DE-9453-4D60-886B-2BFED178B81B\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:h:schneider-electric:tburjr900:01002eh0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9BF82506-8036-4928-9C88-F1DB3B7CCD74\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:h:schneider-electric:tburjr900:05002dh0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"61D7AD31-432E-48AE-A0FB-C6868164A461\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:h:schneider-electric:tburjr900:05002eh0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"07890C35-BB97-416E-A451-9AE2B35FA83A\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:h:schneider-electric:tburjr900:06002dh0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5DB839C6-C3D3-4C61-BC6B-F550AF152965\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:h:schneider-electric:tburjr900:06002eh0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"580C28C8-0136-4F1F-8768-DF4C2F2A0500\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:tburjr900_firmware:3.6.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"29917F5D-651B-40C5-B5F7-0170B90389FA\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:tburjr900_firmware:3.6.1:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"483A3AE5-8421-47CB-8CB8-689D594EDE11\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:tburjr900_firmware:3.6.2:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4B1C8EB0-8562-44B0-9BAE-891089695AE8\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:tburjr900_firmware:3.6.3:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"73E32FDE-9828-4E29-B0C0-BB1899A3296A\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Schneider Electric Trio J-Series License Free Ethernet Radio with firmware 3.6.0 through 3.6.3 uses the same AES encryption key across different customers\u0027 installations, which makes it easier for remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation.\"}, {\"lang\": \"es\", \"value\": \"Schneider Electric Trio J-Series License Free Ethernet Radio con firmware v3.6.0 hasta v3.6.3 utiliza la misma clave de cifrado AES en las distintas instalaciones de los clientes, lo que hace que sea m\\u00e1s f\\u00e1cil para los atacantes remotos saltarse los mecanismos de protecci\\u00f3n de cifrado, mediante el aprovechamiento de los conocimientos de esta clave a partir de otra instalaci\\u00f3n.\"}]",
"id": "CVE-2013-2782",
"lastModified": "2024-11-21T01:52:21.467",
"metrics": "{\"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:C/I:C/A:C\", \"baseScore\": 9.3, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 8.6, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2013-08-28T13:09:15.230",
"references": "[{\"url\": \"http://ics-cert.us-cert.gov/advisories/ICSA-13-234-01\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"US Government Resource\"]}, {\"url\": \"http://www.schneider-electric.com/download/ww/en/file/141141292-SEVD-2013-143-01.pdf\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"http://ics-cert.us-cert.gov/advisories/ICSA-13-234-01\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"US Government Resource\"]}, {\"url\": \"http://www.schneider-electric.com/download/ww/en/file/141141292-SEVD-2013-143-01.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-310\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2013-2782\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2013-08-28T13:09:15.230\",\"lastModified\":\"2025-04-11T00:51:21.963\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Schneider Electric Trio J-Series License Free Ethernet Radio with firmware 3.6.0 through 3.6.3 uses the same AES encryption key across different customers\u0027 installations, which makes it easier for remote attackers to defeat cryptographic protection mechanisms by leveraging knowledge of this key from another installation.\"},{\"lang\":\"es\",\"value\":\"Schneider Electric Trio J-Series License Free Ethernet Radio con firmware v3.6.0 hasta v3.6.3 utiliza la misma clave de cifrado AES en las distintas instalaciones de los clientes, lo que hace que sea m\u00e1s f\u00e1cil para los atacantes remotos saltarse los mecanismos de protecci\u00f3n de cifrado, mediante el aprovechamiento de los conocimientos de esta clave a partir de otra instalaci\u00f3n.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:C/I:C/A:C\",\"baseScore\":9.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.6,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-310\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:schneider-electric:tburjr900:00002dh0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3689A9D3-40FB-4135-A9D3-DFC7AFE7B10B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:schneider-electric:tburjr900:00002eh0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A92E024D-02C0-4B76-8352-ED5357DE34CA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:schneider-electric:tburjr900:01002dh0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"816CA3DE-9453-4D60-886B-2BFED178B81B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:schneider-electric:tburjr900:01002eh0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9BF82506-8036-4928-9C88-F1DB3B7CCD74\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:schneider-electric:tburjr900:05002dh0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"61D7AD31-432E-48AE-A0FB-C6868164A461\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:schneider-electric:tburjr900:05002eh0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"07890C35-BB97-416E-A451-9AE2B35FA83A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:schneider-electric:tburjr900:06002dh0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5DB839C6-C3D3-4C61-BC6B-F550AF152965\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:schneider-electric:tburjr900:06002eh0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"580C28C8-0136-4F1F-8768-DF4C2F2A0500\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:tburjr900_firmware:3.6.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"29917F5D-651B-40C5-B5F7-0170B90389FA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:tburjr900_firmware:3.6.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"483A3AE5-8421-47CB-8CB8-689D594EDE11\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:tburjr900_firmware:3.6.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4B1C8EB0-8562-44B0-9BAE-891089695AE8\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:tburjr900_firmware:3.6.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"73E32FDE-9828-4E29-B0C0-BB1899A3296A\"}]}]}],\"references\":[{\"url\":\"http://ics-cert.us-cert.gov/advisories/ICSA-13-234-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"US Government Resource\"]},{\"url\":\"http://www.schneider-electric.com/download/ww/en/file/141141292-SEVD-2013-143-01.pdf\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://ics-cert.us-cert.gov/advisories/ICSA-13-234-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"US Government Resource\"]},{\"url\":\"http://www.schneider-electric.com/download/ww/en/file/141141292-SEVD-2013-143-01.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…