CVE-2013-2785 (GCVE-0-2013-2785)
Vulnerability from cvelistv5 – Published: 2013-07-31 10:00 – Updated: 2024-09-16 22:24
VLAI?
Summary
Multiple buffer overflows in CimWebServer.exe in the WebView component in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.0 SIM 27, 8.1 before SIM 25, and 8.2 before SIM 19, and Proficy Process Systems with CIMPLICITY, allow remote attackers to execute arbitrary code via crafted data in packets to TCP port 10212, aka ZDI-CAN-1621 and ZDI-CAN-1624.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T15:44:33.660Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-170-01"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=KB15602"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Multiple buffer overflows in CimWebServer.exe in the WebView component in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.0 SIM 27, 8.1 before SIM 25, and 8.2 before SIM 19, and Proficy Process Systems with CIMPLICITY, allow remote attackers to execute arbitrary code via crafted data in packets to TCP port 10212, aka ZDI-CAN-1621 and ZDI-CAN-1624."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-07-31T10:00:00Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-170-01"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=KB15602"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2013-2785",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple buffer overflows in CimWebServer.exe in the WebView component in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.0 SIM 27, 8.1 before SIM 25, and 8.2 before SIM 19, and Proficy Process Systems with CIMPLICITY, allow remote attackers to execute arbitrary code via crafted data in packets to TCP port 10212, aka ZDI-CAN-1621 and ZDI-CAN-1624."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://ics-cert.us-cert.gov/advisories/ICSA-13-170-01",
"refsource": "MISC",
"url": "http://ics-cert.us-cert.gov/advisories/ICSA-13-170-01"
},
{
"name": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=KB15602",
"refsource": "CONFIRM",
"url": "http://support.ge-ip.com/support/index?page=kbchannel\u0026id=KB15602"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2013-2785",
"datePublished": "2013-07-31T10:00:00Z",
"dateReserved": "2013-04-11T00:00:00Z",
"dateUpdated": "2024-09-16T22:24:45.426Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\\\/scada_cimplicity:8.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"90538C50-38BD-4EE5-BD30-96E2E2951FE3\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\\\/scada_cimplicity:8.1:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CB261867-B9B1-4D3D-B2DE-3CC3164EFD06\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\\\/scada_cimplicity:8.2:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"559DCD7A-0745-4D4C-A77A-83240EF6C510\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:ge:intelligent_platforms_proficy_process_systems_with_cimplicity:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"AD9711EA-2C95-41FA-8827-01FCB0ED4B06\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Multiple buffer overflows in CimWebServer.exe in the WebView component in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.0 SIM 27, 8.1 before SIM 25, and 8.2 before SIM 19, and Proficy Process Systems with CIMPLICITY, allow remote attackers to execute arbitrary code via crafted data in packets to TCP port 10212, aka ZDI-CAN-1621 and ZDI-CAN-1624.\"}, {\"lang\": \"es\", \"value\": \"M\\u00faltiples vulnerabilidades de desbordamiento de b\\u00fafer en GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY anterior a 8.0 SIM 27, 8.1 anterior a SIM 25, y 8.2 anterior a SIM 19, y Proficy Process Systems con CIMPLICITY, permite a atacantes remotos la ejecuci\\u00f3n de c\\u00f3digo arbitrario a trav\\u00e9s de datos manipulados en paquetes TCP hacia el puerto 10212. Aka ZDI-CAN-1621 y ZDI-CAN-1624.\"}]",
"id": "CVE-2013-2785",
"lastModified": "2024-11-21T01:52:21.817",
"metrics": "{\"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:C/I:C/A:C\", \"baseScore\": 9.3, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 8.6, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2013-07-31T13:20:28.707",
"references": "[{\"url\": \"http://ics-cert.us-cert.gov/advisories/ICSA-13-170-01\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"US Government Resource\"]}, {\"url\": \"http://support.ge-ip.com/support/index?page=kbchannel\u0026id=KB15602\", \"source\": \"ics-cert@hq.dhs.gov\"}, {\"url\": \"http://ics-cert.us-cert.gov/advisories/ICSA-13-170-01\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"US Government Resource\"]}, {\"url\": \"http://support.ge-ip.com/support/index?page=kbchannel\u0026id=KB15602\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-119\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2013-2785\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2013-07-31T13:20:28.707\",\"lastModified\":\"2025-04-11T00:51:21.963\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Multiple buffer overflows in CimWebServer.exe in the WebView component in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY before 8.0 SIM 27, 8.1 before SIM 25, and 8.2 before SIM 19, and Proficy Process Systems with CIMPLICITY, allow remote attackers to execute arbitrary code via crafted data in packets to TCP port 10212, aka ZDI-CAN-1621 and ZDI-CAN-1624.\"},{\"lang\":\"es\",\"value\":\"M\u00faltiples vulnerabilidades de desbordamiento de b\u00fafer en GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY anterior a 8.0 SIM 27, 8.1 anterior a SIM 25, y 8.2 anterior a SIM 19, y Proficy Process Systems con CIMPLICITY, permite a atacantes remotos la ejecuci\u00f3n de c\u00f3digo arbitrario a trav\u00e9s de datos manipulados en paquetes TCP hacia el puerto 10212. Aka ZDI-CAN-1621 y ZDI-CAN-1624.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:C/I:C/A:C\",\"baseScore\":9.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.6,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\\\/scada_cimplicity:8.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"90538C50-38BD-4EE5-BD30-96E2E2951FE3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\\\/scada_cimplicity:8.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CB261867-B9B1-4D3D-B2DE-3CC3164EFD06\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_hmi\\\\/scada_cimplicity:8.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"559DCD7A-0745-4D4C-A77A-83240EF6C510\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ge:intelligent_platforms_proficy_process_systems_with_cimplicity:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AD9711EA-2C95-41FA-8827-01FCB0ED4B06\"}]}]}],\"references\":[{\"url\":\"http://ics-cert.us-cert.gov/advisories/ICSA-13-170-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"US Government Resource\"]},{\"url\":\"http://support.ge-ip.com/support/index?page=kbchannel\u0026id=KB15602\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"http://ics-cert.us-cert.gov/advisories/ICSA-13-170-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"US Government Resource\"]},{\"url\":\"http://support.ge-ip.com/support/index?page=kbchannel\u0026id=KB15602\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…