CVE-2013-6143 (GCVE-0-2013-6143)

Vulnerability from cvelistv5 – Published: 2014-01-31 16:00 – Updated: 2024-08-06 17:29
VLAI?
Summary
The Schneider Electric Telvent SAGE 3030 RTU with firmware C3413-500-001D3_P4 and C3413-500-001F0_PB allows remote attackers to cause a denial of service (temporary outage and CPU consumption) via malformed DNP3 traffic.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T17:29:43.215Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-006-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2014-01-30T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The Schneider Electric Telvent SAGE 3030 RTU with firmware C3413-500-001D3_P4 and C3413-500-001F0_PB allows remote attackers to cause a denial of service (temporary outage and CPU consumption) via malformed DNP3 traffic."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2014-01-31T16:57:00",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-006-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2013-6143",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Schneider Electric Telvent SAGE 3030 RTU with firmware C3413-500-001D3_P4 and C3413-500-001F0_PB allows remote attackers to cause a denial of service (temporary outage and CPU consumption) via malformed DNP3 traffic."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://ics-cert.us-cert.gov/advisories/ICSA-14-006-01",
              "refsource": "MISC",
              "url": "http://ics-cert.us-cert.gov/advisories/ICSA-14-006-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2013-6143",
    "datePublished": "2014-01-31T16:00:00",
    "dateReserved": "2013-10-16T00:00:00",
    "dateUpdated": "2024-08-06T17:29:43.215Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:telvent_sage_3030_firmware:c3413-500-001d3_p4:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3C4F6DA6-C66C-4EBC-B073-47E1692EBC80\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:telvent_sage_3030_firmware:c3413-500-001f0_pb:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0A8C5D42-04B6-46EA-A018-28ADBEE52F09\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"The Schneider Electric Telvent SAGE 3030 RTU with firmware C3413-500-001D3_P4 and C3413-500-001F0_PB allows remote attackers to cause a denial of service (temporary outage and CPU consumption) via malformed DNP3 traffic.\"}, {\"lang\": \"es\", \"value\": \"El Schneider Electric Telvent SAGE 3030 RTU con filmware C3413-500-001D3_P4 y C3413-500-001F0_PB permite a atacantes remotos causar una denegaci\\u00f3n de servicio (interrupci\\u00f3n temporal y consumo de CPU) a trav\\u00e9s de tr\\u00e1fico DNP3 malformado.\"}]",
      "evaluatorComment": "Vendor advisory:\nhttps://infrastructurecommunity.schneider-electric.com/servlet/JiveServlet/downloadBody/2966-102-1-4299/SAGE%20RTU%20DNP%20Security%20Bulletin%20123013%200102.pdf",
      "id": "CVE-2013-6143",
      "lastModified": "2024-11-21T01:58:44.950",
      "metrics": "{\"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:N/I:N/A:P\", \"baseScore\": 5.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2014-01-31T16:55:05.077",
      "references": "[{\"url\": \"http://ics-cert.us-cert.gov/advisories/ICSA-14-006-01\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"US Government Resource\"]}, {\"url\": \"http://ics-cert.us-cert.gov/advisories/ICSA-14-006-01\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"US Government Resource\"]}]",
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-20\"}, {\"lang\": \"en\", \"value\": \"CWE-399\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2013-6143\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2014-01-31T16:55:05.077\",\"lastModified\":\"2025-04-11T00:51:21.963\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The Schneider Electric Telvent SAGE 3030 RTU with firmware C3413-500-001D3_P4 and C3413-500-001F0_PB allows remote attackers to cause a denial of service (temporary outage and CPU consumption) via malformed DNP3 traffic.\"},{\"lang\":\"es\",\"value\":\"El Schneider Electric Telvent SAGE 3030 RTU con filmware C3413-500-001D3_P4 y C3413-500-001F0_PB permite a atacantes remotos causar una denegaci\u00f3n de servicio (interrupci\u00f3n temporal y consumo de CPU) a trav\u00e9s de tr\u00e1fico DNP3 malformado.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"},{\"lang\":\"en\",\"value\":\"CWE-399\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:telvent_sage_3030_firmware:c3413-500-001d3_p4:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3C4F6DA6-C66C-4EBC-B073-47E1692EBC80\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:telvent_sage_3030_firmware:c3413-500-001f0_pb:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0A8C5D42-04B6-46EA-A018-28ADBEE52F09\"}]}]}],\"references\":[{\"url\":\"http://ics-cert.us-cert.gov/advisories/ICSA-14-006-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"US Government Resource\"]},{\"url\":\"http://ics-cert.us-cert.gov/advisories/ICSA-14-006-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"US Government Resource\"]}],\"evaluatorComment\":\"Vendor advisory:\\nhttps://infrastructurecommunity.schneider-electric.com/servlet/JiveServlet/downloadBody/2966-102-1-4299/SAGE%20RTU%20DNP%20Security%20Bulletin%20123013%200102.pdf\"}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…