CVE-2014-0883 (GCVE-0-2014-0883)
Vulnerability from cvelistv5 – Published: 2018-04-20 21:00 – Updated: 2024-08-06 09:27
VLAI
Title
IBM Power Hardware Management Console cross-site scripting
Summary
IBM Power HMC 7.1.0 through 7.8.0 and 7.3.5 is vulnerable to cross-site scripting. This vulnerability allows users to embed arbitrary JavaScript code in the Web UI thus altering the intended functionality potentially leading to credentials disclosure within a trusted session. IBM X-Force ID: 91163.
Severity
No CVSS data available.
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/security-bullet… | vendor-advisory |
| https://exchange.xforce.ibmcloud.com/vulnerabilit… | vdb-entry |
Impacted products
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T09:27:20.087Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://www.ibm.com/support/pages/security-bulletin-power-hardware-management-console-hmc-cve-2014-0883"
},
{
"tags": [
"vdb-entry",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/91163"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Power HMC",
"vendor": "IBM",
"versions": [
{
"lessThanOrEqual": "7.8.0",
"status": "affected",
"version": "7.1.0",
"versionType": "semver"
},
{
"status": "affected",
"version": "7.3.5"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "IBM Power HMC 7.1.0 through 7.8.0 and 7.3.5 is vulnerable to cross-site scripting. This vulnerability allows users to embed arbitrary JavaScript code in the Web UI thus altering the intended functionality potentially leading to credentials disclosure within a trusted session.\u0026nbsp; IBM X-Force ID:\u0026nbsp; 91163."
}
],
"value": "IBM Power HMC 7.1.0 through 7.8.0 and 7.3.5 is vulnerable to cross-site scripting. This vulnerability allows users to embed arbitrary JavaScript code in the Web UI thus altering the intended functionality potentially leading to credentials disclosure within a trusted session.\u00a0 IBM X-Force ID:\u00a0 91163."
}
],
"metrics": [
{
"cvssV2_0": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-09T01:18:33.347Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.ibm.com/support/pages/security-bulletin-power-hardware-management-console-hmc-cve-2014-0883"
},
{
"tags": [
"vdb-entry"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/91163"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "IBM Power Hardware Management Console cross-site scripting",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2014-0883",
"datePublished": "2018-04-20T21:00:00.000Z",
"dateReserved": "2014-01-06T00:00:00.000Z",
"dateUpdated": "2024-08-06T09:27:20.087Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2014-0883",
"date": "2026-06-10",
"epss": "0.00181",
"percentile": "0.39678"
},
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:ibm:power_hardware_management_console:7r7.1.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F8713B22-6C55-4037-8DA2-F8AEB1DFFE7C\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:ibm:power_hardware_management_console:7r7.2.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7BF8EB61-22AB-4539-85D4-FCEDD1DF8359\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:ibm:power_hardware_management_console:7r7.3.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1BABBB52-A944-4B6F-8454-C87F2FEB122A\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:ibm:power_hardware_management_console:7r7.3.5:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0EF8E1AC-5818-4B38-B5CA-C4DED4971651\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:ibm:power_hardware_management_console:7r7.4.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9AF51303-BBC1-4F08-9679-B921DD1BE1AD\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:ibm:power_hardware_management_console:7r7.5.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8D81C766-D383-41FD-AF67-68CC347C988B\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:ibm:power_hardware_management_console:7r7.6.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"33C1B1E5-7443-48EB-805C-C857CE7E7488\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:ibm:power_hardware_management_console:7r7.7.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1E755A0F-E499-4AD0-81B3-CD51F84F677A\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:ibm:power_hardware_management_console:7r7.7.0:sp1:*:*:*:*:*:*\", \"matchCriteriaId\": \"C6D26DF4-BFBF-423F-B475-A3305CE3C7B7\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:ibm:power_hardware_management_console:7r7.7.0:sp2:*:*:*:*:*:*\", \"matchCriteriaId\": \"B4D2E5AC-81C7-4510-9A2A-01F90CC58AA4\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:ibm:power_hardware_management_console:7r7.8.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"92B51D48-A9F6-4FBF-9E71-9FCC94B0BE45\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"IBM Power HMC 7.1.0 through 7.8.0 and 7.3.5 is vulnerable to cross-site scripting. This vulnerability allows users to embed arbitrary JavaScript code in the Web UI thus altering the intended functionality potentially leading to credentials disclosure within a trusted session.\\u00a0 IBM X-Force ID:\\u00a0 91163.\"}, {\"lang\": \"es\", \"value\": \"Vulnerabilidad de Cross-Site Scripting (XSS) en IBM Power Hardware Management Console (HMC) 7R7.1.0, 7R7.2.0, 7R7.3.0 hasta 7R7.3.5, 7R7.7.0 hasta SP3 y 7R7.8.0 anterior al SP1 permite que atacantes remotos inyecten scripts web o HTML arbitrarios mediante el nombre de usuario en la pantalla de inicio de sesi\\u00f3n. IBM X-Force ID: 91163.\"}]",
"id": "CVE-2014-0883",
"lastModified": "2024-11-21T02:02:58.443",
"metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 6.1, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 2.7}], \"cvssMetricV2\": [{\"source\": \"psirt@us.ibm.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:N/I:P/A:N\", \"baseScore\": 4.3, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:N/I:P/A:N\", \"baseScore\": 4.3, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
"published": "2018-04-20T21:29:00.220",
"references": "[{\"url\": \"https://exchange.xforce.ibmcloud.com/vulnerabilities/91163\", \"source\": \"psirt@us.ibm.com\"}, {\"url\": \"https://www.ibm.com/support/pages/security-bulletin-power-hardware-management-console-hmc-cve-2014-0883\", \"source\": \"psirt@us.ibm.com\"}, {\"url\": \"https://exchange.xforce.ibmcloud.com/vulnerabilities/91163\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://www.ibm.com/support/pages/security-bulletin-power-hardware-management-console-hmc-cve-2014-0883\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
"sourceIdentifier": "psirt@us.ibm.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"psirt@us.ibm.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2014-0883\",\"sourceIdentifier\":\"psirt@us.ibm.com\",\"published\":\"2018-04-20T21:29:00.220\",\"lastModified\":\"2024-11-21T02:02:58.443\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"IBM Power HMC 7.1.0 through 7.8.0 and 7.3.5 is vulnerable to cross-site scripting. This vulnerability allows users to embed arbitrary JavaScript code in the Web UI thus altering the intended functionality potentially leading to credentials disclosure within a trusted session.\u00a0 IBM X-Force ID:\u00a0 91163.\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad de Cross-Site Scripting (XSS) en IBM Power Hardware Management Console (HMC) 7R7.1.0, 7R7.2.0, 7R7.3.0 hasta 7R7.3.5, 7R7.7.0 hasta SP3 y 7R7.8.0 anterior al SP1 permite que atacantes remotos inyecten scripts web o HTML arbitrarios mediante el nombre de usuario en la pantalla de inicio de sesi\u00f3n. IBM X-Force ID: 91163.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"psirt@us.ibm.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:P/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:P/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"psirt@us.ibm.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:power_hardware_management_console:7r7.1.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F8713B22-6C55-4037-8DA2-F8AEB1DFFE7C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:power_hardware_management_console:7r7.2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7BF8EB61-22AB-4539-85D4-FCEDD1DF8359\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:power_hardware_management_console:7r7.3.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1BABBB52-A944-4B6F-8454-C87F2FEB122A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:power_hardware_management_console:7r7.3.5:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0EF8E1AC-5818-4B38-B5CA-C4DED4971651\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:power_hardware_management_console:7r7.4.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9AF51303-BBC1-4F08-9679-B921DD1BE1AD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:power_hardware_management_console:7r7.5.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8D81C766-D383-41FD-AF67-68CC347C988B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:power_hardware_management_console:7r7.6.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"33C1B1E5-7443-48EB-805C-C857CE7E7488\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:power_hardware_management_console:7r7.7.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1E755A0F-E499-4AD0-81B3-CD51F84F677A\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:power_hardware_management_console:7r7.7.0:sp1:*:*:*:*:*:*\",\"matchCriteriaId\":\"C6D26DF4-BFBF-423F-B475-A3305CE3C7B7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:power_hardware_management_console:7r7.7.0:sp2:*:*:*:*:*:*\",\"matchCriteriaId\":\"B4D2E5AC-81C7-4510-9A2A-01F90CC58AA4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:ibm:power_hardware_management_console:7r7.8.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"92B51D48-A9F6-4FBF-9E71-9FCC94B0BE45\"}]}]}],\"references\":[{\"url\":\"https://exchange.xforce.ibmcloud.com/vulnerabilities/91163\",\"source\":\"psirt@us.ibm.com\"},{\"url\":\"https://www.ibm.com/support/pages/security-bulletin-power-hardware-management-console-hmc-cve-2014-0883\",\"source\":\"psirt@us.ibm.com\"},{\"url\":\"https://exchange.xforce.ibmcloud.com/vulnerabilities/91163\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://www.ibm.com/support/pages/security-bulletin-power-hardware-management-console-hmc-cve-2014-0883\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}"
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…