CVE-2014-5408 (GCVE-0-2014-5408)

Vulnerability from cvelistv5 – Published: 2014-11-05 11:00 – Updated: 2025-11-03 18:50
VLAI
Title
Nordex NC2 Cross-site Scripting
Summary
Cross-site scripting (XSS) vulnerability in the login script in the Wind Farm Portal on Nordex Control 2 (NC2) SCADA devices 15 and earlier allows remote attackers to inject arbitrary web script or HTML via the username parameter.
Severity
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
Nordex Nordex Control 2 (NC2) SCADA Affected: 0 , ≤ 15 (custom)
Create a notification for this product.
Date Public
2014-10-30 06:00
Credits
Darius Freamon
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T11:41:49.060Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-303-01"
          },
          {
            "name": "70851",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/70851"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Nordex Control 2 (NC2) SCADA",
          "vendor": "Nordex",
          "versions": [
            {
              "lessThanOrEqual": "15",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Darius Freamon"
        }
      ],
      "datePublic": "2014-10-30T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eCross-site scripting (XSS) vulnerability in the login script in the Wind Farm Portal on Nordex Control 2 (NC2) SCADA devices 15 and earlier allows remote attackers to inject arbitrary web script or HTML via the username parameter.\u003c/p\u003e"
            }
          ],
          "value": "Cross-site scripting (XSS) vulnerability in the login script in the Wind Farm Portal on Nordex Control 2 (NC2) SCADA devices 15 and earlier allows remote attackers to inject arbitrary web script or HTML via the username parameter."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 7.5,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "PARTIAL",
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-03T18:50:14.150Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-303-01"
        },
        {
          "name": "70851",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/70851"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2014/icsa-14-303-01.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eNordex will release a patch for all affected NC2-SCADA versions until\n the end of 2014. The patching of the NC2-SCADA system has to be done by\n Nordex.\u003c/p\u003e\n\u003cp\u003eNordex will upgrade all wind farms with a valid service contract to \nthe patched version of the NC2-SCADA in coordination with normal \nmaintenance operations.\u003c/p\u003e\n\u003cp\u003eOwners of Nordex NC2-based wind farms without a valid service \ncontract can order the patch from Nordex by contacting their local \nNordex service organization.\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Nordex will release a patch for all affected NC2-SCADA versions until\n the end of 2014. The patching of the NC2-SCADA system has to be done by\n Nordex.\n\n\nNordex will upgrade all wind farms with a valid service contract to \nthe patched version of the NC2-SCADA in coordination with normal \nmaintenance operations.\n\n\nOwners of Nordex NC2-based wind farms without a valid service \ncontract can order the patch from Nordex by contacting their local \nNordex service organization."
        }
      ],
      "source": {
        "advisory": "ICSA-14-303-01",
        "discovery": "EXTERNAL"
      },
      "title": "Nordex NC2 Cross-site Scripting",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-5408",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Cross-site scripting (XSS) vulnerability in the login script in the Wind Farm Portal on Nordex Control 2 (NC2) SCADA devices 15 and earlier allows remote attackers to inject arbitrary web script or HTML via the username parameter."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-14-303-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-303-01"
            },
            {
              "name": "70851",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/70851"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-5408",
    "datePublished": "2014-11-05T11:00:00.000Z",
    "dateReserved": "2014-08-22T00:00:00.000Z",
    "dateUpdated": "2025-11-03T18:50:14.150Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2014-5408",
      "date": "2026-05-29",
      "epss": "0.00868",
      "percentile": "0.75476"
    },
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:h:nordex:nordex_control_2_scada:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"15\", \"matchCriteriaId\": \"F8463267-BF0F-4FE4-80B2-4A8F00315C52\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Cross-site scripting (XSS) vulnerability in the login script in the Wind Farm Portal on Nordex Control 2 (NC2) SCADA devices 15 and earlier allows remote attackers to inject arbitrary web script or HTML via the username parameter.\"}, {\"lang\": \"es\", \"value\": \"Vulnerabilidad de XSS en las secuencias de comandos del inicio de sesi\\u00f3n en el portal Wind Farm en los dispositivos SCADA de Nordex Control 2 (NC2) 15 y anteriores permite a atacantes remotos inyectar secuencias de comandos web o HTML arbitrarios a trav\\u00e9s del par\\u00e1metro username.\"}]",
      "id": "CVE-2014-5408",
      "lastModified": "2024-11-21T02:11:59.627",
      "metrics": "{\"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:N/I:P/A:N\", \"baseScore\": 4.3, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
      "published": "2014-11-05T11:55:06.437",
      "references": "[{\"url\": \"http://www.securityfocus.com/bid/70851\", \"source\": \"ics-cert@hq.dhs.gov\"}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-14-303-01\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"http://www.securityfocus.com/bid/70851\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-14-303-01\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}]",
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2014-5408\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2014-11-05T11:55:06.437\",\"lastModified\":\"2026-05-06T22:30:45.220\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Cross-site scripting (XSS) vulnerability in the login script in the Wind Farm Portal on Nordex Control 2 (NC2) SCADA devices 15 and earlier allows remote attackers to inject arbitrary web script or HTML via the username parameter.\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad de XSS en las secuencias de comandos del inicio de sesi\u00f3n en el portal Wind Farm en los dispositivos SCADA de Nordex Control 2 (NC2) 15 y anteriores permite a atacantes remotos inyectar secuencias de comandos web o HTML arbitrarios a trav\u00e9s del par\u00e1metro username.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":7.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:P/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:nordex:nordex_control_2_scada:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"15\",\"matchCriteriaId\":\"F8463267-BF0F-4FE4-80B2-4A8F00315C52\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/70851\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2014/icsa-14-303-01.json\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"https://www.cisa.gov/news-events/ics-advisories/icsa-14-303-01\",\"source\":\"ics-cert@hq.dhs.gov\"},{\"url\":\"http://www.securityfocus.com/bid/70851\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-14-303-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…