cve-2015-3963
Vulnerability from cvelistv5
Published
2015-08-04 01:00
Modified
2024-08-06 06:04
Severity ?
Summary
Wind River VxWorks before 5.5.1, 6.5.x through 6.7.x before 6.7.1.1, 6.8.x before 6.8.3, 6.9.x before 6.9.4.4, and 7.x before 7 ipnet_coreip 1.2.2.0, as used on Schneider Electric SAGE RTU devices before J2 and other devices, does not properly generate TCP initial sequence number (ISN) values, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value.
References
ics-cert@hq.dhs.govhttp://www.schneider-electric.com/ww/en/download/document/SEVD-2015-162-01Patch, Third Party Advisory
ics-cert@hq.dhs.govhttp://www.securityfocus.com/bid/75302Third Party Advisory, VDB Entry
ics-cert@hq.dhs.govhttp://www.securitytracker.com/id/1032730Third Party Advisory, VDB Entry
ics-cert@hq.dhs.govhttp://www.securitytracker.com/id/1033181Third Party Advisory, VDB Entry
ics-cert@hq.dhs.govhttps://ics-cert.us-cert.gov/advisories/ICSA-15-169-01Third Party Advisory, US Government Resource
ics-cert@hq.dhs.govhttps://ics-cert.us-cert.gov/advisories/ICSA-15-169-01AThird Party Advisory, US Government Resource
ics-cert@hq.dhs.govhttps://security.netapp.com/advisory/ntap-20160324-0001/Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108http://www.schneider-electric.com/ww/en/download/document/SEVD-2015-162-01Patch, Third Party Advisory
af854a3a-2127-422b-91ae-364da2661108http://www.securityfocus.com/bid/75302Third Party Advisory, VDB Entry
af854a3a-2127-422b-91ae-364da2661108http://www.securitytracker.com/id/1032730Third Party Advisory, VDB Entry
af854a3a-2127-422b-91ae-364da2661108http://www.securitytracker.com/id/1033181Third Party Advisory, VDB Entry
af854a3a-2127-422b-91ae-364da2661108https://ics-cert.us-cert.gov/advisories/ICSA-15-169-01Third Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://ics-cert.us-cert.gov/advisories/ICSA-15-169-01AThird Party Advisory, US Government Resource
af854a3a-2127-422b-91ae-364da2661108https://security.netapp.com/advisory/ntap-20160324-0001/Third Party Advisory
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T06:04:01.028Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "75302",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/75302"
          },
          {
            "name": "1032730",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1032730"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.schneider-electric.com/ww/en/download/document/SEVD-2015-162-01"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-169-01A"
          },
          {
            "name": "1033181",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1033181"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20160324-0001/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-169-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2015-06-18T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Wind River VxWorks before 5.5.1, 6.5.x through 6.7.x before 6.7.1.1, 6.8.x before 6.8.3, 6.9.x before 6.9.4.4, and 7.x before 7 ipnet_coreip 1.2.2.0, as used on Schneider Electric SAGE RTU devices before J2 and other devices, does not properly generate TCP initial sequence number (ISN) values, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-11-09T10:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "75302",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/75302"
        },
        {
          "name": "1032730",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1032730"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.schneider-electric.com/ww/en/download/document/SEVD-2015-162-01"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-169-01A"
        },
        {
          "name": "1033181",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1033181"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://security.netapp.com/advisory/ntap-20160324-0001/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-169-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2015-3963",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Wind River VxWorks before 5.5.1, 6.5.x through 6.7.x before 6.7.1.1, 6.8.x before 6.8.3, 6.9.x before 6.9.4.4, and 7.x before 7 ipnet_coreip 1.2.2.0, as used on Schneider Electric SAGE RTU devices before J2 and other devices, does not properly generate TCP initial sequence number (ISN) values, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "75302",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/75302"
            },
            {
              "name": "1032730",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1032730"
            },
            {
              "name": "http://www.schneider-electric.com/ww/en/download/document/SEVD-2015-162-01",
              "refsource": "CONFIRM",
              "url": "http://www.schneider-electric.com/ww/en/download/document/SEVD-2015-162-01"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-169-01A",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-169-01A"
            },
            {
              "name": "1033181",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1033181"
            },
            {
              "name": "https://security.netapp.com/advisory/ntap-20160324-0001/",
              "refsource": "CONFIRM",
              "url": "https://security.netapp.com/advisory/ntap-20160324-0001/"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-169-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-169-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2015-3963",
    "datePublished": "2015-08-04T01:00:00",
    "dateReserved": "2015-05-12T00:00:00",
    "dateUpdated": "2024-08-06T06:04:01.028Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:windriver:vxworks:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"6.5\", \"versionEndIncluding\": \"6.6\", \"matchCriteriaId\": \"8F8C5727-B863-4B2D-896B-B079CC49FEBA\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:windriver:vxworks:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"6.7\", \"versionEndExcluding\": \"6.7.1.1\", \"matchCriteriaId\": \"12D324CD-4AAD-484B-BC8D-B0C7A76FC556\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:windriver:vxworks:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"6.8\", \"versionEndExcluding\": \"6.8.3\", \"matchCriteriaId\": \"F1E97899-D5E5-4C4D-A553-B15F1DD31041\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:windriver:vxworks:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"6.9\", \"versionEndExcluding\": \"6.9.4.4\", \"matchCriteriaId\": \"D1DE1FEF-4519-45F6-867D-5248A6B4753C\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:windriver:vxworks:6.6.3:*:*:*:cert:*:*:*\", \"matchCriteriaId\": \"ABFC811A-A440-464A-B5C8-1DB9DEAEEAF1\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:windriver:vxworks:6.6.4:*:*:*:cert:*:*:*\", \"matchCriteriaId\": \"A048ED68-46C5-49B3-9A8E-12F90CE1B6FB\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:windriver:vxworks:6.6.4.1:*:*:*:cert:*:*:*\", \"matchCriteriaId\": \"44AE1224-EFE0-4BA9-8250-1C4BB2F37301\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:windriver:vxworks:7.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D4810B35-06F6-4971-BE87-A30B1CF58AA0\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_1210:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A16A7B3E-0B50-4577-A27C-75422924226C\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_1230:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8EA1F2F1-F8C3-427B-AD6F-778AF0193996\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_1250:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7A95CFF8-563A-45B1-B038-E9DD1AB5C4D0\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_1310:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C9592965-4A3B-4AD8-81F3-EDECC295B567\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_1330:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"AEC4C5D0-DB9C-419A-B30B-62514DEDE901\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_1350:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4D66C8C1-E611-47B1-B9CF-32689F86B392\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"02E606BD-92F8-4396-AD13-666D76E1E34D\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"97E29CCC-4E21-411E-80DD-545A66E9B042\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"66759867-027F-4FA6-ABA6-BFDEE49E8F8D\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_2200:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"82032E41-EE2D-4DC4-8420-6BFE92593061\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"AA561E2A-4787-48D7-ABBB-26D0D7D24E6F\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_3030:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"88F83471-9806-4169-937E-27BDF3FC5A57\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"453696F2-0F4C-4000-A438-F814D0FC3504\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Wind River VxWorks before 5.5.1, 6.5.x through 6.7.x before 6.7.1.1, 6.8.x before 6.8.3, 6.9.x before 6.9.4.4, and 7.x before 7 ipnet_coreip 1.2.2.0, as used on Schneider Electric SAGE RTU devices before J2 and other devices, does not properly generate TCP initial sequence number (ISN) values, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value.\"}, {\"lang\": \"es\", \"value\": \"Vulnerabilidad en Wind River VxWorks en versiones anteriores a 5.5.1, 6.5.x hasta la versi\\u00f3n 6.7.x en versiones anteriores a 6.7.1.1, 6.8.x hasta la versi\\u00f3n 6.8.3, 6.9.x en versiones anteriores a 6.9.4.4 y 7.x en versiones anteriores a 7 ipnet_coreip 1.2.2.0, tal como se utiliza en dispositivos Schneider Electric SAGE RTU en versiones anteriores a J2 y otros dispositivos, no genera correctamente valores del n\\u00famero inicial de secuencia (ISN) de TCP, lo que hace que sea m\\u00e1s f\\u00e1cil para los atacantes remotos falsificar las sesiones TCP al predecir un valor ISN.\"}]",
      "id": "CVE-2015-3963",
      "lastModified": "2024-11-21T02:30:09.507",
      "metrics": "{\"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:N/I:P/A:P\", \"baseScore\": 5.8, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 4.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2015-08-04T01:59:07.357",
      "references": "[{\"url\": \"http://www.schneider-electric.com/ww/en/download/document/SEVD-2015-162-01\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Patch\", \"Third Party Advisory\"]}, {\"url\": \"http://www.securityfocus.com/bid/75302\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"http://www.securitytracker.com/id/1032730\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"http://www.securitytracker.com/id/1033181\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-15-169-01\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-15-169-01A\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://security.netapp.com/advisory/ntap-20160324-0001/\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"http://www.schneider-electric.com/ww/en/download/document/SEVD-2015-162-01\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Third Party Advisory\"]}, {\"url\": \"http://www.securityfocus.com/bid/75302\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"http://www.securitytracker.com/id/1032730\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"http://www.securitytracker.com/id/1033181\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-15-169-01\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-15-169-01A\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://security.netapp.com/advisory/ntap-20160324-0001/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}]",
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-330\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2015-3963\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2015-08-04T01:59:07.357\",\"lastModified\":\"2024-11-21T02:30:09.507\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Wind River VxWorks before 5.5.1, 6.5.x through 6.7.x before 6.7.1.1, 6.8.x before 6.8.3, 6.9.x before 6.9.4.4, and 7.x before 7 ipnet_coreip 1.2.2.0, as used on Schneider Electric SAGE RTU devices before J2 and other devices, does not properly generate TCP initial sequence number (ISN) values, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value.\"},{\"lang\":\"es\",\"value\":\"Vulnerabilidad en Wind River VxWorks en versiones anteriores a 5.5.1, 6.5.x hasta la versi\u00f3n 6.7.x en versiones anteriores a 6.7.1.1, 6.8.x hasta la versi\u00f3n 6.8.3, 6.9.x en versiones anteriores a 6.9.4.4 y 7.x en versiones anteriores a 7 ipnet_coreip 1.2.2.0, tal como se utiliza en dispositivos Schneider Electric SAGE RTU en versiones anteriores a J2 y otros dispositivos, no genera correctamente valores del n\u00famero inicial de secuencia (ISN) de TCP, lo que hace que sea m\u00e1s f\u00e1cil para los atacantes remotos falsificar las sesiones TCP al predecir un valor ISN.\"}],\"metrics\":{\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:P/A:P\",\"baseScore\":5.8,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-330\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:windriver:vxworks:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.5\",\"versionEndIncluding\":\"6.6\",\"matchCriteriaId\":\"8F8C5727-B863-4B2D-896B-B079CC49FEBA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:windriver:vxworks:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.7\",\"versionEndExcluding\":\"6.7.1.1\",\"matchCriteriaId\":\"12D324CD-4AAD-484B-BC8D-B0C7A76FC556\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:windriver:vxworks:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.8\",\"versionEndExcluding\":\"6.8.3\",\"matchCriteriaId\":\"F1E97899-D5E5-4C4D-A553-B15F1DD31041\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:windriver:vxworks:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.9\",\"versionEndExcluding\":\"6.9.4.4\",\"matchCriteriaId\":\"D1DE1FEF-4519-45F6-867D-5248A6B4753C\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:windriver:vxworks:6.6.3:*:*:*:cert:*:*:*\",\"matchCriteriaId\":\"ABFC811A-A440-464A-B5C8-1DB9DEAEEAF1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:windriver:vxworks:6.6.4:*:*:*:cert:*:*:*\",\"matchCriteriaId\":\"A048ED68-46C5-49B3-9A8E-12F90CE1B6FB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:windriver:vxworks:6.6.4.1:*:*:*:cert:*:*:*\",\"matchCriteriaId\":\"44AE1224-EFE0-4BA9-8250-1C4BB2F37301\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:windriver:vxworks:7.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D4810B35-06F6-4971-BE87-A30B1CF58AA0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_1210:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A16A7B3E-0B50-4577-A27C-75422924226C\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_1230:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8EA1F2F1-F8C3-427B-AD6F-778AF0193996\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_1250:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7A95CFF8-563A-45B1-B038-E9DD1AB5C4D0\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_1310:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C9592965-4A3B-4AD8-81F3-EDECC295B567\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_1330:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AEC4C5D0-DB9C-419A-B30B-62514DEDE901\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_1350:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4D66C8C1-E611-47B1-B9CF-32689F86B392\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_1410:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"02E606BD-92F8-4396-AD13-666D76E1E34D\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_1430:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"97E29CCC-4E21-411E-80DD-545A66E9B042\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_1450:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"66759867-027F-4FA6-ABA6-BFDEE49E8F8D\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_2200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"82032E41-EE2D-4DC4-8420-6BFE92593061\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_2400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AA561E2A-4787-48D7-ABBB-26D0D7D24E6F\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_3030:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"88F83471-9806-4169-937E-27BDF3FC5A57\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:sage_3030_magnum:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"453696F2-0F4C-4000-A438-F814D0FC3504\"}]}]}],\"references\":[{\"url\":\"http://www.schneider-electric.com/ww/en/download/document/SEVD-2015-162-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/75302\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://www.securitytracker.com/id/1032730\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://www.securitytracker.com/id/1033181\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-15-169-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-15-169-01A\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20160324-0001/\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"http://www.schneider-electric.com/ww/en/download/document/SEVD-2015-162-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/75302\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://www.securitytracker.com/id/1032730\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://www.securitytracker.com/id/1033181\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-15-169-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-15-169-01A\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20160324-0001/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.