CVE-2016-8784 (GCVE-0-2016-8784)
Vulnerability from cvelistv5 – Published: 2018-03-09 21:00 – Updated: 2024-08-06 02:35- memory leak
| URL | Tags |
|---|---|
| http://www.huawei.com/en/psirt/security-advisorie… | x_refsource_CONFIRM |
| http://www.securityfocus.com/bid/95079 | vdb-entryx_refsource_BID |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Huawei Technologies Co., Ltd. | CloudEngine 12800 |
Affected:
CloudEngine 12800 V100R003C00, V100R003C10, V100R005C00, V100R005C10, V100R006C00
|
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T02:35:00.939Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20161221-01-ldp-en"
},
{
"name": "95079",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/95079"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "CloudEngine 12800",
"vendor": "Huawei Technologies Co., Ltd.",
"versions": [
{
"status": "affected",
"version": "CloudEngine 12800 V100R003C00, V100R003C10, V100R005C00, V100R005C10, V100R006C00"
}
]
}
],
"datePublic": "2016-12-21T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Huawei CloudEngine 12800 V100R003C00, V100R003C10, V100R005C00, V100R005C10, V100R006C00 have a memory leak vulnerability. An unauthenticated attacker may send specific Label Distribution Protocol (LDP) packets to the devices. When the values of some parameters in the packet are abnormal, the LDP processing module does not release the memory to handle the packet, resulting in memory leak."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "memory leak",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-03-10T10:57:01.000Z",
"orgId": "25ac1063-e409-4190-8079-24548c77ea2e",
"shortName": "huawei"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20161221-01-ldp-en"
},
{
"name": "95079",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/95079"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@huawei.com",
"ID": "CVE-2016-8784",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "CloudEngine 12800",
"version": {
"version_data": [
{
"version_value": "CloudEngine 12800 V100R003C00, V100R003C10, V100R005C00, V100R005C10, V100R006C00"
}
]
}
}
]
},
"vendor_name": "Huawei Technologies Co., Ltd."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Huawei CloudEngine 12800 V100R003C00, V100R003C10, V100R005C00, V100R005C10, V100R006C00 have a memory leak vulnerability. An unauthenticated attacker may send specific Label Distribution Protocol (LDP) packets to the devices. When the values of some parameters in the packet are abnormal, the LDP processing module does not release the memory to handle the packet, resulting in memory leak."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "memory leak"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20161221-01-ldp-en",
"refsource": "CONFIRM",
"url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20161221-01-ldp-en"
},
{
"name": "95079",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/95079"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "25ac1063-e409-4190-8079-24548c77ea2e",
"assignerShortName": "huawei",
"cveId": "CVE-2016-8784",
"datePublished": "2018-03-09T21:00:00.000Z",
"dateReserved": "2016-10-18T00:00:00.000Z",
"dateUpdated": "2024-08-06T02:35:00.939Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2016-8784",
"date": "2026-11-04",
"epss": "0.00422",
"percentile": "0.36665"
},
"fkie_nvd": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:huawei:cloudengine_12800_firmware:v100r003c00:*:*:*:*:*:*:*",
"matchCriteriaId": "2AEB5929-1526-4910-BE22-07FCDDA06D0B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:huawei:cloudengine_12800_firmware:v100r003c10:*:*:*:*:*:*:*",
"matchCriteriaId": "5C4D77D6-4CCA-45A3-8B8F-2A2E3AD82753",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:huawei:cloudengine_12800_firmware:v100r005c00:*:*:*:*:*:*:*",
"matchCriteriaId": "E58D7203-2EE3-412A-B39C-94D82B0BBB98",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:huawei:cloudengine_12800_firmware:v100r005c10:*:*:*:*:*:*:*",
"matchCriteriaId": "71EF4F82-092F-4D19-832B-A174F7D47477",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:huawei:cloudengine_12800_firmware:v100r006c00:*:*:*:*:*:*:*",
"matchCriteriaId": "3C2DACA5-0AA6-419B-AC6A-8CC19326758E",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:huawei:cloudengine_12800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DE8A2875-0F7E-4790-A925-5999396B7578",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"descriptions": [
{
"lang": "en",
"value": "Huawei CloudEngine 12800 V100R003C00, V100R003C10, V100R005C00, V100R005C10, V100R006C00 have a memory leak vulnerability. An unauthenticated attacker may send specific Label Distribution Protocol (LDP) packets to the devices. When the values of some parameters in the packet are abnormal, the LDP processing module does not release the memory to handle the packet, resulting in memory leak."
},
{
"lang": "es",
"value": "Huawei CloudEngine 12800 V100R003C00, V100R003C10, V100R005C00, V100R005C10 y V100R006C00 tiene una vulnerabilidad de fuga de memoria. Un atacante no autenticado podr\u00eda enviar paquetes LDP (Label Distribution Protocol) a los dispositivos. Cuando los valores de algunos par\u00e1metros en el paquete no son normales, el m\u00f3dulo de procesamiento LDP no libera la memoria para gestionar el paquete, lo que resulta en una fuga de memoria."
}
],
"id": "CVE-2016-8784",
"lastModified": "2024-11-21T03:00:04.400",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 3.3,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 1.4,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-03-09T21:29:00.300",
"references": [
{
"source": "psirt@huawei.com",
"tags": [
"Vendor Advisory"
],
"url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20161221-01-ldp-en"
},
{
"source": "psirt@huawei.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/95079"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20161221-01-ldp-en"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/95079"
}
],
"sourceIdentifier": "psirt@huawei.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-399"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:huawei:cloudengine_12800_firmware:v100r003c00:*:*:*:*:*:*:*",
"matchCriteriaId": "2AEB5929-1526-4910-BE22-07FCDDA06D0B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:huawei:cloudengine_12800_firmware:v100r003c10:*:*:*:*:*:*:*",
"matchCriteriaId": "5C4D77D6-4CCA-45A3-8B8F-2A2E3AD82753",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:huawei:cloudengine_12800_firmware:v100r005c00:*:*:*:*:*:*:*",
"matchCriteriaId": "E58D7203-2EE3-412A-B39C-94D82B0BBB98",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:huawei:cloudengine_12800_firmware:v100r005c10:*:*:*:*:*:*:*",
"matchCriteriaId": "71EF4F82-092F-4D19-832B-A174F7D47477",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:huawei:cloudengine_12800_firmware:v100r006c00:*:*:*:*:*:*:*",
"matchCriteriaId": "3C2DACA5-0AA6-419B-AC6A-8CC19326758E",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:huawei:cloudengine_12800:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DE8A2875-0F7E-4790-A925-5999396B7578",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Huawei CloudEngine 12800 V100R003C00, V100R003C10, V100R005C00, V100R005C10, V100R006C00 have a memory leak vulnerability. An unauthenticated attacker may send specific Label Distribution Protocol (LDP) packets to the devices. When the values of some parameters in the packet are abnormal, the LDP processing module does not release the memory to handle the packet, resulting in memory leak."
},
{
"lang": "es",
"value": "Huawei CloudEngine 12800 V100R003C00, V100R003C10, V100R005C00, V100R005C10 y V100R006C00 tiene una vulnerabilidad de fuga de memoria. Un atacante no autenticado podr\u00eda enviar paquetes LDP (Label Distribution Protocol) a los dispositivos. Cuando los valores de algunos par\u00e1metros en el paquete no son normales, el m\u00f3dulo de procesamiento LDP no libera la memoria para gestionar el paquete, lo que resulta en una fuga de memoria."
}
],
"id": "CVE-2016-8784",
"lastModified": "2024-11-21T03:00:04.400",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "ADJACENT_NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 3.3,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:A/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.5,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
"version": "3.0"
},
"exploitabilityScore": 2.8,
"impactScore": 1.4,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-03-09T21:29:00.300",
"references": [
{
"source": "psirt@huawei.com",
"tags": [
"Vendor Advisory"
],
"url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20161221-01-ldp-en"
},
{
"source": "psirt@huawei.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/95079"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20161221-01-ldp-en"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/95079"
}
],
"sourceIdentifier": "psirt@huawei.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-399"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.