A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions). Specially crafted packets sent to port 80/tcp could cause the affected devices to go into defect mode. A cold restart is required to recover the system.
References
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-06T02:42:10.987Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "name": "94820", "tags": [ "vdb-entry", "x_refsource_BID", "x_transferred" ], "url": "http://www.securityfocus.com/bid/94820" }, { "name": "1037434", "tags": [ "vdb-entry", "x_refsource_SECTRACK", "x_transferred" ], "url": "http://www.securitytracker.com/id/1037434" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC S7-300 CPU family", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC S7-400 V6 and earlier CPU family", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] }, { "product": "SIMATIC S7-400 V7 CPU family", "vendor": "Siemens AG", "versions": [ { "status": "affected", "version": "All versions" } ] } ], "datePublic": "2016-12-16T00:00:00", "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions). Specially crafted packets sent to port 80/tcp could cause the affected devices to go into defect mode. A cold restart is required to recover the system." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20: Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-03-10T19:16:14", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "name": "94820", "tags": [ "vdb-entry", "x_refsource_BID" ], "url": "http://www.securityfocus.com/bid/94820" }, { "name": "1037434", "tags": [ "vdb-entry", "x_refsource_SECTRACK" ], "url": "http://www.securitytracker.com/id/1037434" }, { "tags": [ "x_refsource_MISC" ], "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2016-9158", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC S7-300 CPU family", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC S7-400 V6 and earlier CPU family", "version": { "version_data": [ { "version_value": "All versions" } ] } }, { "product_name": "SIMATIC S7-400 V7 CPU family", "version": { "version_data": [ { "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens AG" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions). Specially crafted packets sent to port 80/tcp could cause the affected devices to go into defect mode. A cold restart is required to recover the system." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-20: Improper Input Validation" } ] } ] }, "references": { "reference_data": [ { "name": "94820", "refsource": "BID", "url": "http://www.securityfocus.com/bid/94820" }, { "name": "1037434", "refsource": "SECTRACK", "url": "http://www.securitytracker.com/id/1037434" }, { "name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05", "refsource": "MISC", "url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05" }, { "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf", "refsource": "CONFIRM", "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2016-9158", "datePublished": "2016-12-17T03:34:00", "dateReserved": "2016-11-03T00:00:00", "dateUpdated": "2024-08-06T02:42:10.987Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2016-9158\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2016-12-17T03:59:00.187\",\"lastModified\":\"2020-03-10T20:15:11.883\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions). Specially crafted packets sent to port 80/tcp could cause the affected devices to go into defect mode. A cold restart is required to recover the system.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en la familia de CPU SIMATIC S7-300 (todas las versiones), la familia de CPU SIMATIC S7-300 (incluidas las CPU ET200 relacionadas y las variantes SIPLUS) (todas las versiones), SIMATIC S7-400 PN / DP V6 y familias de CPU inferiores (incl. variantes SIPLUS) (todas las versiones), familia de CPU SIMATIC S7-400 PN / DP V7 (incl. variantes SIPLUS) (todas las versiones), SIMATIC S7-400 V6 y familia de CPU anterior (todas las versiones), SIMATIC S7-400 Familia de CPU V7 (todas las versiones). Los paquetes especialmente dise\u00f1ados enviados al puerto 80 / tcp podr\u00edan hacer que los dispositivos afectados entren en modo defectuoso. Se requiere un reinicio en fr\u00edo para recuperar el sistema.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:C\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"COMPLETE\",\"baseScore\":7.8},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":6.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"76189399-9032-4695-A976-8415E26B0DB8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu_312:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4FB328F8-3E03-440B-AB5C-ADA1D4F07F0E\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"78399465-EED5-4EBD-A2E1-6FE0BD01EDB4\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E8FD8E6D-0527-4215-B6F0-5824011433FB\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_pn\\\\/dp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A773F92D-E5C0-4B51-8214-19BFE6BC7638\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu_317-_2_dp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E3C5065F-C0B9-4427-A9D2-072AFF3FCA69\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu_317-2_pn\\\\/dp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A340DA65-BA46-4F72-8951-93135F9F6602\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu_319-3_pn\\\\/dp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7167E5B0-D278-4F63-B5CD-39DBDF336089\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-400_cpu_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F6EBD5F0-16A6-466B-80E5-B95DDBDE2FA3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_412-1:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6498C679-46A3-4F87-9278-F64D2194E1F5\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"85F8C306-45F5-429B-B932-0278A9B909B7\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2_pn:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F0E162F8-B37A-4FFA-A523-FA6227372D37\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_414-2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8CD1CA5C-F729-4311-9E78-156BB6DE31A7\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"20E69856-A628-4B9D-9184-7FB9A924193E\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3_pn\\\\/dp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A1EC8F19-313A-4C74-A68A-AAC320B123CE\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_416-2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"195259DF-8ABE-47A9-9A13-6BDAA25AA898\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3412299F-5778-4290-A80C-29BC6F46F701\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3_pn\\\\/dp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CC41E925-88AF-4D33-AC49-CE5FEAAF2105\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_416f-2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"61363AEF-CBDB-4405-A605-4997798D38D8\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_416f-3_pn\\\\/dp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2CFC71AB-3ACF-4E7E-B83E-31E02DEBDA48\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_417-4:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"711A91B2-EB16-418B-AA63-56DFD40075D7\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/94820\",\"source\":\"productcert@siemens.com\"},{\"url\":\"http://www.securitytracker.com/id/1037434\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf\",\"source\":\"productcert@siemens.com\"}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.