CVE-2016-9159 (GCVE-0-2016-9159)
Vulnerability from cvelistv5 – Published: 2016-12-17 03:34 – Updated: 2024-08-06 02:42
VLAI?
Summary
A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices.
Severity ?
No CVSS data available.
CWE
- CWE-200 - Information Exposure
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens AG | SIMATIC S7-300 CPU family |
Affected:
All versions
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T02:42:11.143Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "94820",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/94820"
},
{
"name": "1037434",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://www.securitytracker.com/id/1037434"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC S7-300 CPU family",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC S7-400 V6 and earlier CPU family",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC S7-400 V7 CPU family",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC S7-410 V8 CPU family",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"datePublic": "2016-12-16T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Information Exposure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-03-10T19:16:14",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"name": "94820",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/94820"
},
{
"name": "1037434",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://www.securitytracker.com/id/1037434"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2016-9159",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC S7-300 CPU family",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC S7-400 V6 and earlier CPU family",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC S7-400 V7 CPU family",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC S7-410 V8 CPU family",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-200: Information Exposure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "94820",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/94820"
},
{
"name": "1037434",
"refsource": "SECTRACK",
"url": "http://www.securitytracker.com/id/1037434"
},
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05"
},
{
"name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf",
"refsource": "CONFIRM",
"url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2016-9159",
"datePublished": "2016-12-17T03:34:00",
"dateReserved": "2016-11-03T00:00:00",
"dateUpdated": "2024-08-06T02:42:11.143Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"76189399-9032-4695-A976-8415E26B0DB8\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-300_cpu_312:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4FB328F8-3E03-440B-AB5C-ADA1D4F07F0E\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"78399465-EED5-4EBD-A2E1-6FE0BD01EDB4\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E8FD8E6D-0527-4215-B6F0-5824011433FB\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_pn\\\\/dp:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A773F92D-E5C0-4B51-8214-19BFE6BC7638\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-300_cpu_317-_2_dp:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E3C5065F-C0B9-4427-A9D2-072AFF3FCA69\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-300_cpu_317-2_pn\\\\/dp:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A340DA65-BA46-4F72-8951-93135F9F6602\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-300_cpu_319-3_pn\\\\/dp:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7167E5B0-D278-4F63-B5CD-39DBDF336089\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:simatic_s7-400_cpu_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F6EBD5F0-16A6-466B-80E5-B95DDBDE2FA3\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-400_cpu_412-1:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6498C679-46A3-4F87-9278-F64D2194E1F5\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"85F8C306-45F5-429B-B932-0278A9B909B7\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2_pn:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F0E162F8-B37A-4FFA-A523-FA6227372D37\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-400_cpu_414-2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8CD1CA5C-F729-4311-9E78-156BB6DE31A7\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"20E69856-A628-4B9D-9184-7FB9A924193E\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3_pn\\\\/dp:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A1EC8F19-313A-4C74-A68A-AAC320B123CE\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-400_cpu_416-2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"195259DF-8ABE-47A9-9A13-6BDAA25AA898\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3412299F-5778-4290-A80C-29BC6F46F701\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3_pn\\\\/dp:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CC41E925-88AF-4D33-AC49-CE5FEAAF2105\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-400_cpu_416f-2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"61363AEF-CBDB-4405-A605-4997798D38D8\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-400_cpu_416f-3_pn\\\\/dp:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2CFC71AB-3ACF-4E7E-B83E-31E02DEBDA48\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:simatic_s7-400_cpu_417-4:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"711A91B2-EB16-418B-AA63-56DFD40075D7\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en la familia de CPU SIMATIC S7-300 (todas las versiones), la familia de CPU SIMATIC S7-300 (incluidas las CPU ET200 relacionadas y las variantes SIPLUS) (todas las versiones), SIMATIC S7-400 PN / DP V6 y familias de CPU inferiores (incl. variantes SIPLUS) (todas las versiones), familia de CPU SIMATIC S7-400 PN / DP V7 (incl. variantes SIPLUS) (todas las versiones), SIMATIC S7-400 V6 y familia de CPU anterior (todas las versiones), SIMATIC S7-400 Familia de CPU V7 (todas las versiones), familia de CPU SIMATIC S7-410 V8 (todas las versiones), familia de CPU SIMATIC S7-410 V8 (incluidas las variantes SIPLUS) (todas las versiones). Un atacante con acceso de red al puerto 102 / tcp (ISO-TSAP) o a trav\\u00e9s de Profibus podr\\u00eda obtener credenciales del PLC si el nivel de protecci\\u00f3n 2 est\\u00e1 configurado en los dispositivos afectados.\"}]",
"id": "CVE-2016-9159",
"lastModified": "2024-11-21T03:00:43.270",
"metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 5.9, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.2, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:P/I:N/A:N\", \"baseScore\": 4.3, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2016-12-17T03:59:00.233",
"references": "[{\"url\": \"http://www.securityfocus.com/bid/94820\", \"source\": \"productcert@siemens.com\"}, {\"url\": \"http://www.securitytracker.com/id/1037434\", \"source\": \"productcert@siemens.com\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf\", \"source\": \"productcert@siemens.com\"}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05\", \"source\": \"productcert@siemens.com\"}, {\"url\": \"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf\", \"source\": \"productcert@siemens.com\"}, {\"url\": \"http://www.securityfocus.com/bid/94820\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"http://www.securitytracker.com/id/1037434\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-200\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-200\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2016-9159\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2016-12-17T03:59:00.233\",\"lastModified\":\"2025-04-12T10:46:40.837\",\"vulnStatus\":\"Deferred\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC S7-300 CPU family (All versions), SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) (All versions), SIMATIC S7-400 V6 and earlier CPU family (All versions), SIMATIC S7-400 V7 CPU family (All versions), SIMATIC S7-410 V8 CPU family (All versions), SIMATIC S7-410 V8 CPU family (incl. SIPLUS variants) (All versions). An attacker with network access to port 102/tcp (ISO-TSAP) or via Profibus could obtain credentials from the PLC if protection-level 2 is configured on the affected devices.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en la familia de CPU SIMATIC S7-300 (todas las versiones), la familia de CPU SIMATIC S7-300 (incluidas las CPU ET200 relacionadas y las variantes SIPLUS) (todas las versiones), SIMATIC S7-400 PN / DP V6 y familias de CPU inferiores (incl. variantes SIPLUS) (todas las versiones), familia de CPU SIMATIC S7-400 PN / DP V7 (incl. variantes SIPLUS) (todas las versiones), SIMATIC S7-400 V6 y familia de CPU anterior (todas las versiones), SIMATIC S7-400 Familia de CPU V7 (todas las versiones), familia de CPU SIMATIC S7-410 V8 (todas las versiones), familia de CPU SIMATIC S7-410 V8 (incluidas las variantes SIPLUS) (todas las versiones). Un atacante con acceso de red al puerto 102 / tcp (ISO-TSAP) o a trav\u00e9s de Profibus podr\u00eda obtener credenciales del PLC si el nivel de protecci\u00f3n 2 est\u00e1 configurado en los dispositivos afectados.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":5.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.2,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:N/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-300_cpu_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"76189399-9032-4695-A976-8415E26B0DB8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu_312:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4FB328F8-3E03-440B-AB5C-ADA1D4F07F0E\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu_314:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"78399465-EED5-4EBD-A2E1-6FE0BD01EDB4\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_dp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E8FD8E6D-0527-4215-B6F0-5824011433FB\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu_315-2_pn\\\\/dp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A773F92D-E5C0-4B51-8214-19BFE6BC7638\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu_317-_2_dp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E3C5065F-C0B9-4427-A9D2-072AFF3FCA69\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu_317-2_pn\\\\/dp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A340DA65-BA46-4F72-8951-93135F9F6602\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-300_cpu_319-3_pn\\\\/dp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7167E5B0-D278-4F63-B5CD-39DBDF336089\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_s7-400_cpu_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F6EBD5F0-16A6-466B-80E5-B95DDBDE2FA3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_412-1:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6498C679-46A3-4F87-9278-F64D2194E1F5\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"85F8C306-45F5-429B-B932-0278A9B909B7\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_412-2_pn:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F0E162F8-B37A-4FFA-A523-FA6227372D37\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_414-2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8CD1CA5C-F729-4311-9E78-156BB6DE31A7\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"20E69856-A628-4B9D-9184-7FB9A924193E\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_414-3_pn\\\\/dp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A1EC8F19-313A-4C74-A68A-AAC320B123CE\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_416-2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"195259DF-8ABE-47A9-9A13-6BDAA25AA898\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3412299F-5778-4290-A80C-29BC6F46F701\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_416-3_pn\\\\/dp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CC41E925-88AF-4D33-AC49-CE5FEAAF2105\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_416f-2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"61363AEF-CBDB-4405-A605-4997798D38D8\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_416f-3_pn\\\\/dp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2CFC71AB-3ACF-4E7E-B83E-31E02DEBDA48\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_s7-400_cpu_417-4:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"711A91B2-EB16-418B-AA63-56DFD40075D7\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/94820\",\"source\":\"productcert@siemens.com\"},{\"url\":\"http://www.securitytracker.com/id/1037434\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05\",\"source\":\"productcert@siemens.com\"},{\"url\":\"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf\",\"source\":\"productcert@siemens.com\"},{\"url\":\"http://www.securityfocus.com/bid/94820\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.securitytracker.com/id/1037434\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-731239.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-16-348-05\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-731239.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…