cve-2017-10606
Vulnerability from cvelistv5
Published
2017-10-13 17:00
Modified
2024-09-17 02:42
Summary
SRX Series: Cryptographic weakness in SRX300 Series TPM Firmware
References
Impacted products
Juniper NetworksJunos OS
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:41:55.511Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://kb.juniper.net/JSA10809"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "SRX300 Series"
          ],
          "product": "Junos OS",
          "vendor": "Juniper Networks",
          "versions": [
            {
              "status": "affected",
              "version": "15.1X49 prior to TPM firmware version 4.43"
            }
          ]
        }
      ],
      "datePublic": "2017-10-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Version 4.40 of the TPM (Trusted Platform Module) firmware on Juniper Networks SRX300 Series has a weakness in generating cryptographic keys that may allow an attacker to decrypt sensitive information in SRX300 Series products. The TPM is used in the SRX300 Series to encrypt sensitive configuration data. While other products also ship with a TPM, no other products or platforms are affected by this vulnerability. Customers can confirm the version of TPM firmware via the \u0027show security tpm status\u0027 command. This issue was discovered by an external security researcher. No other Juniper Networks products or platforms are affected by this issue."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Inadequate Encryption Strength",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-10-13T16:57:01",
        "orgId": "8cbe9d5a-a066-4c94-8978-4b15efeae968",
        "shortName": "juniper"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://kb.juniper.net/JSA10809"
        }
      ],
      "title": "SRX Series: Cryptographic weakness in SRX300 Series TPM Firmware",
      "workarounds": [
        {
          "lang": "en",
          "value": "There is no known workaround for this issue."
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "sirt@juniper.net",
          "DATE_PUBLIC": "2017-10-11T09:00",
          "ID": "CVE-2017-10606",
          "STATE": "PUBLIC",
          "TITLE": "SRX Series: Cryptographic weakness in SRX300 Series TPM Firmware"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Junos OS",
                      "version": {
                        "version_data": [
                          {
                            "platform": "SRX300 Series",
                            "version_value": "15.1X49 prior to TPM firmware version 4.43"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Juniper Networks"
              }
            ]
          }
        },
        "configuration": [],
        "credit": [],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Version 4.40 of the TPM (Trusted Platform Module) firmware on Juniper Networks SRX300 Series has a weakness in generating cryptographic keys that may allow an attacker to decrypt sensitive information in SRX300 Series products. The TPM is used in the SRX300 Series to encrypt sensitive configuration data. While other products also ship with a TPM, no other products or platforms are affected by this vulnerability. Customers can confirm the version of TPM firmware via the \u0027show security tpm status\u0027 command. This issue was discovered by an external security researcher. No other Juniper Networks products or platforms are affected by this issue."
            }
          ]
        },
        "exploit": "Juniper SIRT is not aware of any malicious exploitation of this vulnerability.",
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 4.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Inadequate Encryption Strength"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.juniper.net/JSA10809",
              "refsource": "CONFIRM",
              "url": "https://kb.juniper.net/JSA10809"
            }
          ]
        },
        "solution": "TPM firmware version 4.43 resolves this specific issue.  Updating TPM firmware requires one of the following software releases: Junos OS 15.1X49-D111, 17.4R1, or any subsequent release.\n\nNote: Junos OS 17.3 is unaffected by this issue since TPM functionality is not supported in this release.\n\nThe TPM firmware is then updated via a special \"jtpm\" package available for download along with the updated Junos OS package.  After upgrading to a fixed release above, execute the following command to update the TPM firmware:\n\n  user@junos\u003e request system software add jtpm-15.1X49-D111-signed.tgz\n\nWhen the TPM firmware is updated, the log message \"TPM firmware updated successfully.\" will appear on the screen.  After updating the TPM firmware, reboot the system using the \u2018request system reboot\u2019 command.\n \nOnce system reboots, verify TPM status using the \u2018show security tpm status\u2019 command.  The TPM Firmware revision should show as 4.43 instead of 4.40.\n\n\nThis issue is being tracked as PR 1293114 and is visible on the Customer Support website.",
        "work_around": [
          {
            "lang": "en",
            "value": "There is no known workaround for this issue."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8cbe9d5a-a066-4c94-8978-4b15efeae968",
    "assignerShortName": "juniper",
    "cveId": "CVE-2017-10606",
    "datePublished": "2017-10-13T17:00:00Z",
    "dateReserved": "2017-06-28T00:00:00",
    "dateUpdated": "2024-09-17T02:42:14.098Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2017-10606\",\"sourceIdentifier\":\"sirt@juniper.net\",\"published\":\"2017-10-13T17:29:00.457\",\"lastModified\":\"2019-10-09T23:21:39.167\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Version 4.40 of the TPM (Trusted Platform Module) firmware on Juniper Networks SRX300 Series has a weakness in generating cryptographic keys that may allow an attacker to decrypt sensitive information in SRX300 Series products. The TPM is used in the SRX300 Series to encrypt sensitive configuration data. While other products also ship with a TPM, no other products or platforms are affected by this vulnerability. Customers can confirm the version of TPM firmware via the \u0027show security tpm status\u0027 command. This issue was discovered by an external security researcher. No other Juniper Networks products or platforms are affected by this issue.\"},{\"lang\":\"es\",\"value\":\"La versi\u00f3n 4.40 de firmware del TPM (Trusted Platform Module) en la serie SRX300 de Juniper Networks tiene una vulnerabilidad a la hora de generar claves criptogr\u00e1ficas que podr\u00eda permitir que un atacante descifre informaci\u00f3n sensible en los productos de la serie SRX300. El TPM se utiliza en la serie SRX300 para cifrar datos de configuraci\u00f3n sensibles. Aunque otros productos tambi\u00e9n dan servicio con un TPM, no existen otros productos o plataformas que se vean afectados por esta vulnerabilidad. Los clientes pueden confirmar la versi\u00f3n del firmware del TPM mediante el comando \\\"show security tpm status\\\". Un investigador de seguridad externo descubri\u00f3 este problema. No hay ning\u00fan otro producto o plataforma de Juniper Networks que se vea afectado por este problema.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.4,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":0.8,\"impactScore\":3.6},{\"source\":\"sirt@juniper.net\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.4,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":0.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:N/A:N\",\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":2.1},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":3.9,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:juniper:trusted_platform_module_firmware:4.40:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F31C77A3-3CDB-4393-A6CC-7B1F54CF27E3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:juniper:srx300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BB5AB24B-2B43-43DD-AE10-F758B4B19F2A\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:juniper:srx320:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"80F9DC32-5ADF-4430-B1A6-357D0B29DB78\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:juniper:srx340:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8B82D4C4-7A65-409A-926F-33C054DCBFBA\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:juniper:srx345:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CE535749-F4CE-4FFA-B23D-BF09C92481E5\"}]}]}],\"references\":[{\"url\":\"https://kb.juniper.net/JSA10809\",\"source\":\"sirt@juniper.net\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.