CVE-2017-18715 (GCVE-0-2017-18715)
Vulnerability from cvelistv5 – Published: 2020-04-24 13:32 – Updated: 2024-08-05 21:37
VLAI?
Summary
Certain NETGEAR devices are affected by reflected XSS. This affects EX3700 before 1.0.0.66, EX3800 before 1.0.0.66, EX6100 before 1.0.2.20, EX6120 before 1.0.0.34, EX6150 before 1.0.0.36, EX6200 before 1.0.3.84, and EX7000 before 1.0.0.60.
Severity ?
5.2 (Medium)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T21:37:42.918Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://kb.netgear.com/000053133/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Extenders-PSV-2016-0075"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by reflected XSS. This affects EX3700 before 1.0.0.66, EX3800 before 1.0.0.66, EX6100 before 1.0.2.20, EX6120 before 1.0.0.34, EX6150 before 1.0.0.36, EX6200 before 1.0.3.84, and EX7000 before 1.0.0.60."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:L/I:L/PR:N/S:C/UI:R",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-24T13:32:18",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://kb.netgear.com/000053133/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Extenders-PSV-2016-0075"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-18715",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by reflected XSS. This affects EX3700 before 1.0.0.66, EX3800 before 1.0.0.66, EX6100 before 1.0.2.20, EX6120 before 1.0.0.34, EX6150 before 1.0.0.36, EX6200 before 1.0.3.84, and EX7000 before 1.0.0.60."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"availabilityImpact": "NONE",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:N/C:L/I:L/PR:N/S:C/UI:R",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000053133/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Extenders-PSV-2016-0075",
"refsource": "CONFIRM",
"url": "https://kb.netgear.com/000053133/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Extenders-PSV-2016-0075"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2017-18715",
"datePublished": "2020-04-24T13:32:18",
"dateReserved": "2020-04-20T00:00:00",
"dateUpdated": "2024-08-05T21:37:42.918Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.0.66\", \"matchCriteriaId\": \"30915FC1-9C6E-4489-B61C-EC7EC311DF8C\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CDAA5899-B73C-4690-853E-B5400F034BE1\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.0.66\", \"matchCriteriaId\": \"8B16C884-E17F-4E30-8027-A6CF1E489309\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CC5488D9-651C-4BAB-A141-06B816690D42\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.2.20\", \"matchCriteriaId\": \"F28E1B99-7B65-4876-96B4-267CAE21D8F5\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:ex6100:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"AB84CD03-765C-4D4F-A176-364F8E72A4E7\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.0.34\", \"matchCriteriaId\": \"10486221-D787-4403-963E-FADEF2451B77\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8C6DFDB6-1D7A-459A-8D30-FD4900ED718B\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.0.36\", \"matchCriteriaId\": \"66193CFA-4E07-4905-B41A-C1986B830C71\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:ex6150:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"46452E97-9347-4788-9570-1EECECC7255E\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.3.84\", \"matchCriteriaId\": \"D4BC0A4D-0C9D-47AD-9A9A-3416E812EC7D\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:ex6200:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3186CC67-B567-4A0C-BD2C-0433716FBD1B\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.0.60\", \"matchCriteriaId\": \"42A19A73-B5FC-4D14-82D0-2128D3E7178B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9F45B620-60B8-40F3-A055-181ADD71EFFF\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Certain NETGEAR devices are affected by reflected XSS. This affects EX3700 before 1.0.0.66, EX3800 before 1.0.0.66, EX6100 before 1.0.2.20, EX6120 before 1.0.0.34, EX6150 before 1.0.0.36, EX6200 before 1.0.3.84, and EX7000 before 1.0.0.60.\"}, {\"lang\": \"es\", \"value\": \"Determinados dispositivos NETGEAR est\\u00e1n afectados por una vulnerabilidad de tipo XSS reflejado. Esto afecta a EX3700 versiones anteriores a la versi\\u00f3n 1.0.0.66, EX3800 versiones anteriores a la versi\\u00f3n 1.0.0.66, EX6100 versiones anteriores a 1.0.2.20, EX6120 versiones anteriores a 1.0.0.34, EX6150 versiones anteriores a 1.0.0.36, EX6200 versiones anteriores a 1.0.3.84, y EX7000 versiones anteriores a 1.0.0.60.\"}]",
"id": "CVE-2017-18715",
"lastModified": "2024-11-21T03:20:44.233",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 6.1, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 2.7}], \"cvssMetricV30\": [{\"source\": \"cve@mitre.org\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 5.2, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"ADJACENT_NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.1, \"impactScore\": 2.7}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:N/I:P/A:N\", \"baseScore\": 4.3, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
"published": "2020-04-24T14:15:13.060",
"references": "[{\"url\": \"https://kb.netgear.com/000053133/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Extenders-PSV-2016-0075\", \"source\": \"cve@mitre.org\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://kb.netgear.com/000053133/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Extenders-PSV-2016-0075\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2017-18715\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2020-04-24T14:15:13.060\",\"lastModified\":\"2024-11-21T03:20:44.233\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Certain NETGEAR devices are affected by reflected XSS. This affects EX3700 before 1.0.0.66, EX3800 before 1.0.0.66, EX6100 before 1.0.2.20, EX6120 before 1.0.0.34, EX6150 before 1.0.0.36, EX6200 before 1.0.3.84, and EX7000 before 1.0.0.60.\"},{\"lang\":\"es\",\"value\":\"Determinados dispositivos NETGEAR est\u00e1n afectados por una vulnerabilidad de tipo XSS reflejado. Esto afecta a EX3700 versiones anteriores a la versi\u00f3n 1.0.0.66, EX3800 versiones anteriores a la versi\u00f3n 1.0.0.66, EX6100 versiones anteriores a 1.0.2.20, EX6120 versiones anteriores a 1.0.0.34, EX6150 versiones anteriores a 1.0.0.36, EX6200 versiones anteriores a 1.0.3.84, y EX7000 versiones anteriores a 1.0.0.60.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}],\"cvssMetricV30\":[{\"source\":\"cve@mitre.org\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":5.2,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.1,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:P/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.0.66\",\"matchCriteriaId\":\"30915FC1-9C6E-4489-B61C-EC7EC311DF8C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CDAA5899-B73C-4690-853E-B5400F034BE1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.0.66\",\"matchCriteriaId\":\"8B16C884-E17F-4E30-8027-A6CF1E489309\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CC5488D9-651C-4BAB-A141-06B816690D42\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex6100_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.2.20\",\"matchCriteriaId\":\"F28E1B99-7B65-4876-96B4-267CAE21D8F5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex6100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AB84CD03-765C-4D4F-A176-364F8E72A4E7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex6120_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.0.34\",\"matchCriteriaId\":\"10486221-D787-4403-963E-FADEF2451B77\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex6120:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8C6DFDB6-1D7A-459A-8D30-FD4900ED718B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex6150_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.0.36\",\"matchCriteriaId\":\"66193CFA-4E07-4905-B41A-C1986B830C71\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex6150:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"46452E97-9347-4788-9570-1EECECC7255E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.3.84\",\"matchCriteriaId\":\"D4BC0A4D-0C9D-47AD-9A9A-3416E812EC7D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex6200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3186CC67-B567-4A0C-BD2C-0433716FBD1B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.0.60\",\"matchCriteriaId\":\"42A19A73-B5FC-4D14-82D0-2128D3E7178B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9F45B620-60B8-40F3-A055-181ADD71EFFF\"}]}]}],\"references\":[{\"url\":\"https://kb.netgear.com/000053133/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Extenders-PSV-2016-0075\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://kb.netgear.com/000053133/Security-Advisory-for-Reflected-Cross-Site-Scripting-on-Some-Extenders-PSV-2016-0075\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…