CVE-2017-18747 (GCVE-0-2017-18747)

Vulnerability from cvelistv5 – Published: 2020-04-23 15:31 – Updated: 2024-08-05 21:37
VLAI?
Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects EX3700 before 1.0.0.64, EX3800 before 1.0.0.64, EX6000 before 1.0.0.24, EX6130 before 1.0.0.16, EX6400 before 1.0.1.60, EX7000 before 1.0.0.50, EX7300 before 1.0.1.60, and WN2500RPv2 before 1.0.1.46.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T21:37:44.067Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000051507/Security-Advisory-for-Security-Misconfiguration-on-Some-Extenders-PSV-2016-0115"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects EX3700 before 1.0.0.64, EX3800 before 1.0.0.64, EX6000 before 1.0.0.24, EX6130 before 1.0.0.16, EX6400 before 1.0.1.60, EX7000 before 1.0.0.50, EX7300 before 1.0.1.60, and WN2500RPv2 before 1.0.1.46."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-23T15:31:49",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://kb.netgear.com/000051507/Security-Advisory-for-Security-Misconfiguration-on-Some-Extenders-PSV-2016-0115"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2017-18747",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects EX3700 before 1.0.0.64, EX3800 before 1.0.0.64, EX6000 before 1.0.0.24, EX6130 before 1.0.0.16, EX6400 before 1.0.1.60, EX7000 before 1.0.0.50, EX7300 before 1.0.1.60, and WN2500RPv2 before 1.0.1.46."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "availabilityImpact": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000051507/Security-Advisory-for-Security-Misconfiguration-on-Some-Extenders-PSV-2016-0115",
              "refsource": "CONFIRM",
              "url": "https://kb.netgear.com/000051507/Security-Advisory-for-Security-Misconfiguration-on-Some-Extenders-PSV-2016-0115"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2017-18747",
    "datePublished": "2020-04-23T15:31:49",
    "dateReserved": "2020-04-20T00:00:00",
    "dateUpdated": "2024-08-05T21:37:44.067Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.0.64\", \"matchCriteriaId\": \"B79CB764-3B62-4C39-9B68-A7C949EA91BE\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CDAA5899-B73C-4690-853E-B5400F034BE1\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.0.64\", \"matchCriteriaId\": \"72C578B9-6D52-492F-854F-067EB36F84B1\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CC5488D9-651C-4BAB-A141-06B816690D42\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:ex6000_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.0.24\", \"matchCriteriaId\": \"520E4E2B-FF48-4B11-8A41-975B1A5E9FA2\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:ex6000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"02E7CA7E-E6CA-4BAB-8F40-4731EA523D91\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.0.16\", \"matchCriteriaId\": \"0EF0C67F-9F79-4D2D-9453-824697828403\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"305E295C-9C73-4798-A0BE-7973E1EE5EAB\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.1.60\", \"matchCriteriaId\": \"4684219C-634D-4147-B1E9-CB736FF41A36\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1289BBB4-1955-46A4-B5FE-BF11153C24F5\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.0.50\", \"matchCriteriaId\": \"0CE0EC7C-EA3B-4624-BDA4-9FE3257B9E69\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9F45B620-60B8-40F3-A055-181ADD71EFFF\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.1.60\", \"matchCriteriaId\": \"4EB53B93-A502-4C92-830A-B0C968070AC7\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F285D60D-A5DA-4467-8F79-15EF8135D007\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:wn2500rp_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.1.46\", \"matchCriteriaId\": \"07CEF0FF-41A1-485B-8CDA-DB7AE8ECDB69\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:wn2500rp:v2:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1C4C1B98-9551-4862-AEAC-3D5C313BD275\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects EX3700 before 1.0.0.64, EX3800 before 1.0.0.64, EX6000 before 1.0.0.24, EX6130 before 1.0.0.16, EX6400 before 1.0.1.60, EX7000 before 1.0.0.50, EX7300 before 1.0.1.60, and WN2500RPv2 before 1.0.1.46.\"}, {\"lang\": \"es\", \"value\": \"Determinados dispositivos NETGEAR est\\u00e1n afectados por una configuraci\\u00f3n incorrecta de los ajustes de seguridad. Esto afecta a EX3700 versiones anteriores a 1.0.0.64, EX3800 versiones anteriores a 1.0.0.64, EX6000 versiones anteriores a 1.0.0.24, EX6130 versiones anteriores a 1.0.0.16, EX6400 versiones anteriores a 1.0.1.60, EX7000 versiones anteriores a 1.0.0.50, EX7300 versiones anteriores a 1.0.1.60 y WN2500RPv2 versiones anteriores a 1.0.1.46 .\"}]",
      "id": "CVE-2017-18747",
      "lastModified": "2024-11-21T03:20:49.440",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\", \"baseScore\": 6.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"ADJACENT_NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 3.6}], \"cvssMetricV30\": [{\"source\": \"cve@mitre.org\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"ADJACENT_NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:A/AC:L/Au:N/C:N/I:P/A:N\", \"baseScore\": 3.3, \"accessVector\": \"ADJACENT_NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"LOW\", \"exploitabilityScore\": 6.5, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2020-04-23T16:15:12.883",
      "references": "[{\"url\": \"https://kb.netgear.com/000051507/Security-Advisory-for-Security-Misconfiguration-on-Some-Extenders-PSV-2016-0115\", \"source\": \"cve@mitre.org\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://kb.netgear.com/000051507/Security-Advisory-for-Security-Misconfiguration-on-Some-Extenders-PSV-2016-0115\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-20\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2017-18747\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2020-04-23T16:15:12.883\",\"lastModified\":\"2024-11-21T03:20:49.440\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects EX3700 before 1.0.0.64, EX3800 before 1.0.0.64, EX6000 before 1.0.0.24, EX6130 before 1.0.0.16, EX6400 before 1.0.1.60, EX7000 before 1.0.0.50, EX7300 before 1.0.1.60, and WN2500RPv2 before 1.0.1.46.\"},{\"lang\":\"es\",\"value\":\"Determinados dispositivos NETGEAR est\u00e1n afectados por una configuraci\u00f3n incorrecta de los ajustes de seguridad. Esto afecta a EX3700 versiones anteriores a 1.0.0.64, EX3800 versiones anteriores a 1.0.0.64, EX6000 versiones anteriores a 1.0.0.24, EX6130 versiones anteriores a 1.0.0.16, EX6400 versiones anteriores a 1.0.1.60, EX7000 versiones anteriores a 1.0.0.50, EX7300 versiones anteriores a 1.0.1.60 y WN2500RPv2 versiones anteriores a 1.0.1.46 .\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}],\"cvssMetricV30\":[{\"source\":\"cve@mitre.org\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:A/AC:L/Au:N/C:N/I:P/A:N\",\"baseScore\":3.3,\"accessVector\":\"ADJACENT_NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":6.5,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex3700_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.0.64\",\"matchCriteriaId\":\"B79CB764-3B62-4C39-9B68-A7C949EA91BE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex3700:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CDAA5899-B73C-4690-853E-B5400F034BE1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex3800_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.0.64\",\"matchCriteriaId\":\"72C578B9-6D52-492F-854F-067EB36F84B1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex3800:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CC5488D9-651C-4BAB-A141-06B816690D42\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex6000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.0.24\",\"matchCriteriaId\":\"520E4E2B-FF48-4B11-8A41-975B1A5E9FA2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex6000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"02E7CA7E-E6CA-4BAB-8F40-4731EA523D91\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex6130_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.0.16\",\"matchCriteriaId\":\"0EF0C67F-9F79-4D2D-9453-824697828403\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex6130:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"305E295C-9C73-4798-A0BE-7973E1EE5EAB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex6400_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.1.60\",\"matchCriteriaId\":\"4684219C-634D-4147-B1E9-CB736FF41A36\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex6400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1289BBB4-1955-46A4-B5FE-BF11153C24F5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex7000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.0.50\",\"matchCriteriaId\":\"0CE0EC7C-EA3B-4624-BDA4-9FE3257B9E69\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex7000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9F45B620-60B8-40F3-A055-181ADD71EFFF\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex7300_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.1.60\",\"matchCriteriaId\":\"4EB53B93-A502-4C92-830A-B0C968070AC7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex7300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F285D60D-A5DA-4467-8F79-15EF8135D007\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:wn2500rp_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.1.46\",\"matchCriteriaId\":\"07CEF0FF-41A1-485B-8CDA-DB7AE8ECDB69\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:wn2500rp:v2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1C4C1B98-9551-4862-AEAC-3D5C313BD275\"}]}]}],\"references\":[{\"url\":\"https://kb.netgear.com/000051507/Security-Advisory-for-Security-Misconfiguration-on-Some-Extenders-PSV-2016-0115\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://kb.netgear.com/000051507/Security-Advisory-for-Security-Misconfiguration-on-Some-Extenders-PSV-2016-0115\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…