GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2017-18762 (GCVE-0-2017-18762)

Vulnerability from cvelistv5 – Published: 2020-04-22 15:44 – Updated: 2024-08-05 21:37
VLAI
Summary
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D3600 before 1.0.0.68, D6000 before 1.0.0.68, D6100 before 1.0.0.57, R6100 before 1.0.1.16, R6900P before 1.2.0.22, R7000 before 1.0.9.10, R7000P before 1.2.0.22, R7100LG before 1.0.0.40, WNDR3700v4 before 1.0.2.88, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.58.
CWE
  • n/a
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T21:37:43.399Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://kb.netgear.com/000051483/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2451"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D3600 before 1.0.0.68, D6000 before 1.0.0.68, D6100 before 1.0.0.57, R6100 before 1.0.1.16, R6900P before 1.2.0.22, R7000 before 1.0.9.10, R7000P before 1.2.0.22, R7100LG before 1.0.0.40, WNDR3700v4 before 1.0.2.88, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.58."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-22T15:44:39.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://kb.netgear.com/000051483/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2451"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2017-18762",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D3600 before 1.0.0.68, D6000 before 1.0.0.68, D6100 before 1.0.0.57, R6100 before 1.0.1.16, R6900P before 1.2.0.22, R7000 before 1.0.9.10, R7000P before 1.2.0.22, R7100LG before 1.0.0.40, WNDR3700v4 before 1.0.2.88, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.58."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT",
            "availabilityImpact": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:N/S:U/UI:N",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.netgear.com/000051483/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2451",
              "refsource": "CONFIRM",
              "url": "https://kb.netgear.com/000051483/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2451"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2017-18762",
    "datePublished": "2020-04-22T15:44:39.000Z",
    "dateReserved": "2020-04-20T00:00:00.000Z",
    "dateUpdated": "2024-08-05T21:37:43.399Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2017-18762",
      "date": "2026-09-20",
      "epss": "0.01857",
      "percentile": "0.78247"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D55132B3-B7CF-4BB9-B28B-406136D0C97B",
                  "versionEndExcluding": "1.0.0.68",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2B5E3F3F-237F-4ADD-8853-CEBE78AAAC36",
                  "versionEndExcluding": "1.0.0.68",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "2ECEA129-164C-4C80-A81E-9688F4AC3583",
                  "versionEndExcluding": "1.0.0.57",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "01A66936-4268-4990-8E83-24C74A75B9F6",
                  "versionEndExcluding": "1.0.1.16",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A8D2A56D-4AAA-4E55-AE7A-E343EA9D6133",
                  "versionEndExcluding": "1.2.0.22",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DD7D570E-C5EF-4D3E-BCCF-926DBDB12016",
                  "versionEndExcluding": "1.0.9.10",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4E7FE05C-8ACF-4D53-A6D9-2C99673CE41A",
                  "versionEndExcluding": "1.2.0.22",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EB388895-B579-43B7-A88E-4BD28D41F6E2",
                  "versionEndExcluding": "1.0.0.40",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3C2E8B48-CF6F-488A-A932-246B434CAF1B",
                  "versionEndExcluding": "1.0.2.88",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*",
                  "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3D0CAC32-5F12-45E6-AC84-D9D5020A41E6",
                  "versionEndExcluding": "1.0.2.90",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0",
                  "versionEndExcluding": "1.0.0.48",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A",
                  "versionEndExcluding": "1.0.0.48",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*",
                  "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9C819040-B30C-4393-9DD4-8E5744B13050",
                  "versionEndExcluding": "1.0.0.58",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*",
                  "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D3600 before 1.0.0.68, D6000 before 1.0.0.68, D6100 before 1.0.0.57, R6100 before 1.0.1.16, R6900P before 1.2.0.22, R7000 before 1.0.9.10, R7000P before 1.2.0.22, R7100LG before 1.0.0.40, WNDR3700v4 before 1.0.2.88, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.58."
        },
        {
          "lang": "es",
          "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.68, D6000 versiones anteriores a 1.0.0.68, D6100 versiones anteriores a 1.0.0.57, R6100 versiones anteriores a 1.0.1.16, R6900P versiones anteriores a 1.2.0.22, R7000 versiones anteriores a 1.0.9.10, R7000P versiones anteriores a 1.2.0.22, R7100LG versiones anteriores a 1.0.0.40, WNDR3700v4 versiones anteriores a 1.0.2.88, WNDR4300v1 versiones anteriores a 1.0.2.90, WNDR4300v2 versiones anteriores a 1.0.0.48, WNDR4500v3 versiones anteriores a 1.0.0.48 y WNR2000v5 versiones anteriores a 1.0.0.58."
        }
      ],
      "id": "CVE-2017-18762",
      "lastModified": "2024-11-21T03:20:51.437",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": false,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "ADJACENT_NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "PARTIAL",
              "baseScore": 5.8,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
              "version": "2.0"
            },
            "exploitabilityScore": 6.5,
            "impactScore": 6.4,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.0"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "cve@mitre.org",
            "type": "Secondary"
          }
        ],
        "cvssMetricV31": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "ADJACENT_NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 8.8,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            },
            "exploitabilityScore": 2.8,
            "impactScore": 5.9,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2020-04-22T16:15:11.373",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://kb.netgear.com/000051483/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2451"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Vendor Advisory"
          ],
          "url": "https://kb.netgear.com/000051483/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2451"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-74"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:netgear:d3600_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D55132B3-B7CF-4BB9-B28B-406136D0C97B",
                    "versionEndExcluding": "1.0.0.68",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:netgear:d3600:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "31DE9D4E-3CDC-4552-A63F-DD5D95E23F63",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:netgear:d6000_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2B5E3F3F-237F-4ADD-8853-CEBE78AAAC36",
                    "versionEndExcluding": "1.0.0.68",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:netgear:d6000:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6F6EA344-FF99-4F27-9860-3C5BE07345A7",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:netgear:d6100_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2ECEA129-164C-4C80-A81E-9688F4AC3583",
                    "versionEndExcluding": "1.0.0.57",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:netgear:d6100:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "7EFD1E86-F100-4E46-935D-903EB6FEFE9D",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:netgear:r6100_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "01A66936-4268-4990-8E83-24C74A75B9F6",
                    "versionEndExcluding": "1.0.1.16",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:netgear:r6100:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9F44A123-B256-428B-98C2-17570F2F32DC",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:netgear:r6900p_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A8D2A56D-4AAA-4E55-AE7A-E343EA9D6133",
                    "versionEndExcluding": "1.2.0.22",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:netgear:r6900p:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C41908FF-AE64-4949-80E3-BEE061B2DA8A",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:netgear:r7000_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "DD7D570E-C5EF-4D3E-BCCF-926DBDB12016",
                    "versionEndExcluding": "1.0.9.10",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:netgear:r7000:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C9F86FF6-AB32-4E51-856A-DDE790C0A9A6",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:netgear:r7000p_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "4E7FE05C-8ACF-4D53-A6D9-2C99673CE41A",
                    "versionEndExcluding": "1.2.0.22",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:netgear:r7000p:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "DFE55F4D-E98B-46D3-B870-041141934CD1",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:netgear:r7100lg_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "EB388895-B579-43B7-A88E-4BD28D41F6E2",
                    "versionEndExcluding": "1.0.0.40",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:netgear:r7100lg:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "366FA778-3C2A-42AF-9141-DAD7043B406C",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "3C2E8B48-CF6F-488A-A932-246B434CAF1B",
                    "versionEndExcluding": "1.0.2.88",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*",
                    "matchCriteriaId": "257A5E68-8EDC-44F5-A85C-83A91C93CCE5",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "3D0CAC32-5F12-45E6-AC84-D9D5020A41E6",
                    "versionEndExcluding": "1.0.2.90",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:netgear:wndr4300:v1:*:*:*:*:*:*:*",
                    "matchCriteriaId": "D99E146D-B278-4CA6-8156-7D9923015779",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8B1EBB8F-818F-4E04-BB25-A81C1C309CD0",
                    "versionEndExcluding": "1.0.0.48",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*",
                    "matchCriteriaId": "4428B145-B86D-4709-BBA9-64BDE7D35A25",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9591B73B-93BF-4976-998B-0200C990EF6A",
                    "versionEndExcluding": "1.0.0.48",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C31D6808-4103-4543-B7AB-84A79CD12006",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9C819040-B30C-4393-9DD4-8E5744B13050",
                    "versionEndExcluding": "1.0.0.58",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*",
                    "matchCriteriaId": "317F25FF-B3A2-4C68-888F-D2627C564867",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects D3600 before 1.0.0.68, D6000 before 1.0.0.68, D6100 before 1.0.0.57, R6100 before 1.0.1.16, R6900P before 1.2.0.22, R7000 before 1.0.9.10, R7000P before 1.2.0.22, R7100LG before 1.0.0.40, WNDR3700v4 before 1.0.2.88, WNDR4300v1 before 1.0.2.90, WNDR4300v2 before 1.0.0.48, WNDR4500v3 before 1.0.0.48, and WNR2000v5 before 1.0.0.58."
          },
          {
            "lang": "es",
            "value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un atacante no autenticado. Esto afecta a D3600 versiones anteriores a 1.0.0.68, D6000 versiones anteriores a 1.0.0.68, D6100 versiones anteriores a 1.0.0.57, R6100 versiones anteriores a 1.0.1.16, R6900P versiones anteriores a 1.2.0.22, R7000 versiones anteriores a 1.0.9.10, R7000P versiones anteriores a 1.2.0.22, R7100LG versiones anteriores a 1.0.0.40, WNDR3700v4 versiones anteriores a 1.0.2.88, WNDR4300v1 versiones anteriores a 1.0.2.90, WNDR4300v2 versiones anteriores a 1.0.0.48, WNDR4500v3 versiones anteriores a 1.0.0.48 y WNR2000v5 versiones anteriores a 1.0.0.58."
          }
        ],
        "id": "CVE-2017-18762",
        "lastModified": "2024-11-21T03:20:51.437",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "ADJACENT_NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "PARTIAL",
                "baseScore": 5.8,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:A/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              "exploitabilityScore": 6.5,
              "impactScore": 6.4,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV30": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 5.9,
              "source": "cve@mitre.org",
              "type": "Secondary"
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2020-04-22T16:15:11.373",
        "references": [
          {
            "source": "cve@mitre.org",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://kb.netgear.com/000051483/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2451"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://kb.netgear.com/000051483/Security-Advisory-for-Pre-Authentication-Command-Injection-on-Some-Routers-and-Gateways-PSV-2017-2451"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-74"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…