CVE-2017-7575 (GCVE-0-2017-7575)
Vulnerability from cvelistv5 – Published: 2017-04-06 21:00 – Updated: 2026-05-29 13:40
VLAI
Summary
Schneider Electric Modicon TM221CE16R 1.3.3.3 devices allow remote attackers to discover the application-protection password via a \x00\x01\x00\x00\x00\x05\x01\x5a\x00\x03\x00 request to the Modbus port (502/tcp). Subsequently the application may be arbitrarily downloaded, modified, and uploaded.
Severity
9.8 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
3 references
| URL | Tags |
|---|---|
| http://download.schneider-electric.com/files?p_Do… | x_refsource_CONFIRM |
| https://os-s.net/advisories/OSS-2017-01.pdf | x_refsource_MISC |
| http://www.securityfocus.com/bid/97523 | vdb-entryx_refsource_BID |
Date Public
2017-04-06 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T16:04:12.098Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-02"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://os-s.net/advisories/OSS-2017-01.pdf"
},
{
"name": "97523",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/97523"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2017-7575",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-05-29T13:37:23.199080Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-29T13:40:37.087Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2017-04-06T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Schneider Electric Modicon TM221CE16R 1.3.3.3 devices allow remote attackers to discover the application-protection password via a \\x00\\x01\\x00\\x00\\x00\\x05\\x01\\x5a\\x00\\x03\\x00 request to the Modbus port (502/tcp). Subsequently the application may be arbitrarily downloaded, modified, and uploaded."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-04-14T04:57:01.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-02"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://os-s.net/advisories/OSS-2017-01.pdf"
},
{
"name": "97523",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/97523"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2017-7575",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Schneider Electric Modicon TM221CE16R 1.3.3.3 devices allow remote attackers to discover the application-protection password via a \\x00\\x01\\x00\\x00\\x00\\x05\\x01\\x5a\\x00\\x03\\x00 request to the Modbus port (502/tcp). Subsequently the application may be arbitrarily downloaded, modified, and uploaded."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-02",
"refsource": "CONFIRM",
"url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-02"
},
{
"name": "https://os-s.net/advisories/OSS-2017-01.pdf",
"refsource": "MISC",
"url": "https://os-s.net/advisories/OSS-2017-01.pdf"
},
{
"name": "97523",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/97523"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2017-7575",
"datePublished": "2017-04-06T21:00:00.000Z",
"dateReserved": "2017-04-06T00:00:00.000Z",
"dateUpdated": "2026-05-29T13:40:37.087Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2017-7575",
"date": "2026-06-02",
"epss": "0.01623",
"percentile": "0.8217"
},
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:schneider-electric:modicon_tm221ce16r_firmware:1.3.3.3:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"26C40BAF-2C91-4069-A62E-1B1E60BA1619\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:schneider-electric:modicon_tm221ce16r:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"00715571-AC4B-4B1F-8E65-385B56F2004C\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Schneider Electric Modicon TM221CE16R 1.3.3.3 devices allow remote attackers to discover the application-protection password via a \\\\x00\\\\x01\\\\x00\\\\x00\\\\x00\\\\x05\\\\x01\\\\x5a\\\\x00\\\\x03\\\\x00 request to the Modbus port (502/tcp). Subsequently the application may be arbitrarily downloaded, modified, and uploaded.\"}, {\"lang\": \"es\", \"value\": \"Los dispositivos Schneider Electric Modicon TM221CE16R 1.3.3.3 permiten a atacantes remotos descubrir la contrase\\u00f1a de protecci\\u00f3n de la aplicaci\\u00f3n a trav\\u00e9s de una solicitud \\\\x00\\\\x01\\\\x00\\\\x00\\\\x00\\\\x05\\\\x01\\\\x5a\\\\x00\\\\x03\\\\x00 al puerto Modbus (502/tcp). Posteriormente la aplicaci\\u00f3n puede descargarse, modificarse y cargarse arbitrariamente.\"}]",
"id": "CVE-2017-7575",
"lastModified": "2024-11-21T03:32:11.873",
"metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:N/A:N\", \"baseScore\": 5.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2017-04-06T21:59:00.337",
"references": "[{\"url\": \"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-02\", \"source\": \"cve@mitre.org\"}, {\"url\": \"http://www.securityfocus.com/bid/97523\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://os-s.net/advisories/OSS-2017-01.pdf\", \"source\": \"cve@mitre.org\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-02\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}, {\"url\": \"http://www.securityfocus.com/bid/97523\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://os-s.net/advisories/OSS-2017-01.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}]",
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-200\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2017-7575\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2017-04-06T21:59:00.337\",\"lastModified\":\"2026-05-29T14:16:21.647\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Schneider Electric Modicon TM221CE16R 1.3.3.3 devices allow remote attackers to discover the application-protection password via a \\\\x00\\\\x01\\\\x00\\\\x00\\\\x00\\\\x05\\\\x01\\\\x5a\\\\x00\\\\x03\\\\x00 request to the Modbus port (502/tcp). Subsequently the application may be arbitrarily downloaded, modified, and uploaded.\"},{\"lang\":\"es\",\"value\":\"Los dispositivos Schneider Electric Modicon TM221CE16R 1.3.3.3 permiten a atacantes remotos descubrir la contrase\u00f1a de protecci\u00f3n de la aplicaci\u00f3n a trav\u00e9s de una solicitud \\\\x00\\\\x01\\\\x00\\\\x00\\\\x00\\\\x05\\\\x01\\\\x5a\\\\x00\\\\x03\\\\x00 al puerto Modbus (502/tcp). Posteriormente la aplicaci\u00f3n puede descargarse, modificarse y cargarse arbitrariamente.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-200\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:schneider-electric:modicon_tm221ce16r_firmware:1.3.3.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"26C40BAF-2C91-4069-A62E-1B1E60BA1619\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:schneider-electric:modicon_tm221ce16r:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"00715571-AC4B-4B1F-8E65-385B56F2004C\"}]}]}],\"references\":[{\"url\":\"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-02\",\"source\":\"cve@mitre.org\"},{\"url\":\"http://www.securityfocus.com/bid/97523\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://os-s.net/advisories/OSS-2017-01.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-02\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"},{\"url\":\"http://www.securityfocus.com/bid/97523\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://os-s.net/advisories/OSS-2017-01.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-02\", \"tags\": [\"x_refsource_CONFIRM\", \"x_transferred\"]}, {\"url\": \"https://os-s.net/advisories/OSS-2017-01.pdf\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}, {\"url\": \"http://www.securityfocus.com/bid/97523\", \"name\": \"97523\", \"tags\": [\"vdb-entry\", \"x_refsource_BID\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-05T16:04:12.098Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2017-7575\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-05-29T13:37:23.199080Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-200\", \"description\": \"CWE-200 Exposure of Sensitive Information to an Unauthorized Actor\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-05-29T13:37:54.733Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"datePublic\": \"2017-04-06T00:00:00.000Z\", \"references\": [{\"url\": \"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-02\", \"tags\": [\"x_refsource_CONFIRM\"]}, {\"url\": \"https://os-s.net/advisories/OSS-2017-01.pdf\", \"tags\": [\"x_refsource_MISC\"]}, {\"url\": \"http://www.securityfocus.com/bid/97523\", \"name\": \"97523\", \"tags\": [\"vdb-entry\", \"x_refsource_BID\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"Schneider Electric Modicon TM221CE16R 1.3.3.3 devices allow remote attackers to discover the application-protection password via a \\\\x00\\\\x01\\\\x00\\\\x00\\\\x00\\\\x05\\\\x01\\\\x5a\\\\x00\\\\x03\\\\x00 request to the Modbus port (502/tcp). Subsequently the application may be arbitrarily downloaded, modified, and uploaded.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"n/a\"}]}], \"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2017-04-14T04:57:01.000Z\"}, \"x_legacyV4Record\": {\"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"n/a\"}]}, \"product_name\": \"n/a\"}]}, \"vendor_name\": \"n/a\"}]}}, \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-02\", \"name\": \"http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-097-02\", \"refsource\": \"CONFIRM\"}, {\"url\": \"https://os-s.net/advisories/OSS-2017-01.pdf\", \"name\": \"https://os-s.net/advisories/OSS-2017-01.pdf\", \"refsource\": \"MISC\"}, {\"url\": \"http://www.securityfocus.com/bid/97523\", \"name\": \"97523\", \"refsource\": \"BID\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"Schneider Electric Modicon TM221CE16R 1.3.3.3 devices allow remote attackers to discover the application-protection password via a \\\\x00\\\\x01\\\\x00\\\\x00\\\\x00\\\\x05\\\\x01\\\\x5a\\\\x00\\\\x03\\\\x00 request to the Modbus port (502/tcp). Subsequently the application may be arbitrarily downloaded, modified, and uploaded.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"n/a\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2017-7575\", \"STATE\": \"PUBLIC\", \"ASSIGNER\": \"cve@mitre.org\"}}}}",
"cveMetadata": "{\"cveId\": \"CVE-2017-7575\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-05-29T13:40:37.087Z\", \"dateReserved\": \"2017-04-06T00:00:00.000Z\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"datePublished\": \"2017-04-06T21:00:00.000Z\", \"assignerShortName\": \"mitre\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…