CVE-2018-11036 (GCVE-0-2018-11036)

Vulnerability from cvelistv5 – Published: 2018-05-31 12:00 – Updated: 2024-08-05 07:54
VLAI
Summary
Ruckus SmartZone (formerly Virtual SmartCell Gateway or vSCG) 3.5.0, 3.5.1, 3.6.0, and 3.6.1 (Essentials and High Scale) on vSZ, SZ-100, SZ-300, and SCG-200 devices allows remote attackers to obtain sensitive information or modify data.
CWE
  • n/a
References
Date Public
2018-05-31 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T07:54:36.536Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.ruckuswireless.com/security/279/view/txt"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-05-31T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Ruckus SmartZone (formerly Virtual SmartCell Gateway or vSCG) 3.5.0, 3.5.1, 3.6.0, and 3.6.1 (Essentials and High Scale) on vSZ, SZ-100, SZ-300, and SCG-200 devices allows remote attackers to obtain sensitive information or modify data."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-05-31T11:57:01.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.ruckuswireless.com/security/279/view/txt"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-11036",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Ruckus SmartZone (formerly Virtual SmartCell Gateway or vSCG) 3.5.0, 3.5.1, 3.6.0, and 3.6.1 (Essentials and High Scale) on vSZ, SZ-100, SZ-300, and SCG-200 devices allows remote attackers to obtain sensitive information or modify data."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.ruckuswireless.com/security/279/view/txt",
              "refsource": "MISC",
              "url": "https://www.ruckuswireless.com/security/279/view/txt"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-11036",
    "datePublished": "2018-05-31T12:00:00.000Z",
    "dateReserved": "2018-05-13T00:00:00.000Z",
    "dateUpdated": "2024-08-05T07:54:36.536Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2018-11036",
      "date": "2026-09-22",
      "epss": "0.01338",
      "percentile": "0.70031"
    },
    "fkie_nvd": {
      "configurations": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:ruckuswireless:vsz_firmware:3.5.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9998987C-0AD2-4CDB-9511-2BC9462490AE",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:ruckuswireless:vsz_firmware:3.5.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "EF9AF4FE-6115-4F24-B171-62A5DB74A6BC",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:ruckuswireless:vsz_firmware:3.6.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "71FD8B5B-EA1B-4ABA-B0A1-CF675F8765F5",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:ruckuswireless:vsz_firmware:3.6.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "38393B8A-E549-4C07-A73E-BEB6DEB08E6A",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:ruckuswireless:vsz:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "A1E9A46B-D8E4-489A-8648-28EDDF000E28",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:ruckuswireless:scg-200_firmware:3.5.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AF021C98-2D73-48E3-AB05-F69C9D3AD569",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:ruckuswireless:scg-200_firmware:3.5.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F95F4D57-D238-47E6-AAF7-8A19B18FC29C",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:ruckuswireless:scg-200_firmware:3.6.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "F7F0BA42-FF78-4F7D-AF63-C731B0C32DD2",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:ruckuswireless:scg-200_firmware:3.6.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "CB65F202-22C7-4E57-8EF3-8BA1DE6A3BA3",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:ruckuswireless:scg-200:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "B1BD8748-6B99-4218-8D76-3A6A5847DB25",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:ruckuswireless:sz-300_firmware:3.5.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "45CEB61E-3E81-4F2D-B23E-8332E95C6C23",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:ruckuswireless:sz-300_firmware:3.5.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "FF91774B-2DE9-4478-AD17-D7C4477CE458",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:ruckuswireless:sz-300_firmware:3.6.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "AA61F6F5-591D-45D2-90B2-4096A60BB978",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:ruckuswireless:sz-300_firmware:3.6.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "9945DADB-81D0-407B-A8C1-FFA9B5A6B228",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:ruckuswireless:sz-300:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4087D2FB-0853-40AE-A03F-803B5972A404",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        },
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:ruckuswireless:sz-100_firmware:3.5.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "ECB56AD5-AE22-4497-852B-EDB12E7B68BC",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:ruckuswireless:sz-100_firmware:3.5.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "6AF9CED5-087A-475B-8A8D-C05F45ADEF57",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:ruckuswireless:sz-100_firmware:3.6.0:*:*:*:*:*:*:*",
                  "matchCriteriaId": "4C5A6C11-3349-448B-99E7-1A5AF17E4872",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:ruckuswireless:sz-100_firmware:3.6.1:*:*:*:*:*:*:*",
                  "matchCriteriaId": "0A116EBD-77CD-4F93-A1BB-56DDF64F2EA4",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            },
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:h:ruckuswireless:sz-100:-:*:*:*:*:*:*:*",
                  "matchCriteriaId": "3B9F3E41-79CA-45B7-B799-B0A64E60BA16",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "AND"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Ruckus SmartZone (formerly Virtual SmartCell Gateway or vSCG) 3.5.0, 3.5.1, 3.6.0, and 3.6.1 (Essentials and High Scale) on vSZ, SZ-100, SZ-300, and SCG-200 devices allows remote attackers to obtain sensitive information or modify data."
        },
        {
          "lang": "es",
          "value": "Ruckus SmartZone (anteriormente Virtual SmartCell Gateway o vSCG) 3.5.0, 3.5.1, 3.6.0 y 3.6.1 (Essentials y High Scale) en dispositivos vSZ, SZ-100, SZ-300 y SCG-200 permite a los atacantes remotos obtener informaci\u00f3n sensible o modificar datos."
        }
      ],
      "id": "CVE-2018-11036",
      "lastModified": "2024-11-21T03:42:32.317",
      "metrics": {
        "cvssMetricV2": [
          {
            "acInsufInfo": true,
            "baseSeverity": "MEDIUM",
            "cvssData": {
              "accessComplexity": "LOW",
              "accessVector": "NETWORK",
              "authentication": "NONE",
              "availabilityImpact": "NONE",
              "baseScore": 6.4,
              "confidentialityImpact": "PARTIAL",
              "integrityImpact": "PARTIAL",
              "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
              "version": "2.0"
            },
            "exploitabilityScore": 10.0,
            "impactScore": 4.9,
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "source": "nvd@nist.gov",
            "type": "Primary",
            "userInteractionRequired": false
          }
        ],
        "cvssMetricV30": [
          {
            "cvssData": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 9.1,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
              "version": "3.0"
            },
            "exploitabilityScore": 3.9,
            "impactScore": 5.2,
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      },
      "published": "2018-05-31T12:29:00.220",
      "references": [
        {
          "source": "cve@mitre.org",
          "tags": [
            "Mailing List",
            "Vendor Advisory"
          ],
          "url": "https://www.ruckuswireless.com/security/279/view/txt"
        },
        {
          "source": "af854a3a-2127-422b-91ae-364da2661108",
          "tags": [
            "Mailing List",
            "Vendor Advisory"
          ],
          "url": "https://www.ruckuswireless.com/security/279/view/txt"
        }
      ],
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": [
        {
          "description": [
            {
              "lang": "en",
              "value": "CWE-200"
            }
          ],
          "source": "nvd@nist.gov",
          "type": "Primary"
        }
      ]
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ruckuswireless:vsz_firmware:3.5.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9998987C-0AD2-4CDB-9511-2BC9462490AE",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ruckuswireless:vsz_firmware:3.5.1:*:*:*:*:*:*:*",
                    "matchCriteriaId": "EF9AF4FE-6115-4F24-B171-62A5DB74A6BC",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ruckuswireless:vsz_firmware:3.6.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "71FD8B5B-EA1B-4ABA-B0A1-CF675F8765F5",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ruckuswireless:vsz_firmware:3.6.1:*:*:*:*:*:*:*",
                    "matchCriteriaId": "38393B8A-E549-4C07-A73E-BEB6DEB08E6A",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ruckuswireless:vsz:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A1E9A46B-D8E4-489A-8648-28EDDF000E28",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ruckuswireless:scg-200_firmware:3.5.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AF021C98-2D73-48E3-AB05-F69C9D3AD569",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ruckuswireless:scg-200_firmware:3.5.1:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F95F4D57-D238-47E6-AAF7-8A19B18FC29C",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ruckuswireless:scg-200_firmware:3.6.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F7F0BA42-FF78-4F7D-AF63-C731B0C32DD2",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ruckuswireless:scg-200_firmware:3.6.1:*:*:*:*:*:*:*",
                    "matchCriteriaId": "CB65F202-22C7-4E57-8EF3-8BA1DE6A3BA3",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ruckuswireless:scg-200:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B1BD8748-6B99-4218-8D76-3A6A5847DB25",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ruckuswireless:sz-300_firmware:3.5.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "45CEB61E-3E81-4F2D-B23E-8332E95C6C23",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ruckuswireless:sz-300_firmware:3.5.1:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FF91774B-2DE9-4478-AD17-D7C4477CE458",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ruckuswireless:sz-300_firmware:3.6.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AA61F6F5-591D-45D2-90B2-4096A60BB978",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ruckuswireless:sz-300_firmware:3.6.1:*:*:*:*:*:*:*",
                    "matchCriteriaId": "9945DADB-81D0-407B-A8C1-FFA9B5A6B228",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ruckuswireless:sz-300:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "4087D2FB-0853-40AE-A03F-803B5972A404",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:ruckuswireless:sz-100_firmware:3.5.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "ECB56AD5-AE22-4497-852B-EDB12E7B68BC",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ruckuswireless:sz-100_firmware:3.5.1:*:*:*:*:*:*:*",
                    "matchCriteriaId": "6AF9CED5-087A-475B-8A8D-C05F45ADEF57",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ruckuswireless:sz-100_firmware:3.6.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "4C5A6C11-3349-448B-99E7-1A5AF17E4872",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:ruckuswireless:sz-100_firmware:3.6.1:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0A116EBD-77CD-4F93-A1BB-56DDF64F2EA4",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:ruckuswireless:sz-100:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "3B9F3E41-79CA-45B7-B799-B0A64E60BA16",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Ruckus SmartZone (formerly Virtual SmartCell Gateway or vSCG) 3.5.0, 3.5.1, 3.6.0, and 3.6.1 (Essentials and High Scale) on vSZ, SZ-100, SZ-300, and SCG-200 devices allows remote attackers to obtain sensitive information or modify data."
          },
          {
            "lang": "es",
            "value": "Ruckus SmartZone (anteriormente Virtual SmartCell Gateway o vSCG) 3.5.0, 3.5.1, 3.6.0 y 3.6.1 (Essentials y High Scale) en dispositivos vSZ, SZ-100, SZ-300 y SCG-200 permite a los atacantes remotos obtener informaci\u00f3n sensible o modificar datos."
          }
        ],
        "id": "CVE-2018-11036",
        "lastModified": "2024-11-21T03:42:32.317",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": true,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "NONE",
                "baseScore": 6.4,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:N",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 4.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV30": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 9.1,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
                "version": "3.0"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.2,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2018-05-31T12:29:00.220",
        "references": [
          {
            "source": "cve@mitre.org",
            "tags": [
              "Mailing List",
              "Vendor Advisory"
            ],
            "url": "https://www.ruckuswireless.com/security/279/view/txt"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Mailing List",
              "Vendor Advisory"
            ],
            "url": "https://www.ruckuswireless.com/security/279/view/txt"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-200"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…