A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker with elevated user privileges (manufact) could modify a CRAMFS archive so that after reboot the system loads the modified CRAMFS file and attacker-controlled code is executed with root privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires elevated user privileges (manufact) but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T08:10:14.579Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "106185",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/106185"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8",
          "vendor": "Siemens AG",
          "versions": [
            {
              "status": "affected",
              "version": "SINUMERIK 808D V4.7 : All versions"
            },
            {
              "status": "affected",
              "version": "SINUMERIK 808D V4.8 : All versions"
            },
            {
              "status": "affected",
              "version": "SINUMERIK 828D V4.7 : All versions \u003c V4.7 SP6 HF1"
            },
            {
              "status": "affected",
              "version": "SINUMERIK 840D sl V4.7 : All versions \u003c V4.7 SP6 HF5"
            },
            {
              "status": "affected",
              "version": "SINUMERIK 840D sl V4.8 : All versions \u003c V4.8 SP3"
            }
          ]
        }
      ],
      "datePublic": "2018-12-12T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions \u003c V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions \u003c V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions \u003c V4.8 SP3). A local attacker with elevated user privileges (manufact) could modify a CRAMFS archive so that after reboot the system loads the modified CRAMFS file and attacker-controlled code is executed with root privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires elevated user privileges (manufact) but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-693",
              "description": "CWE-693: Protection Mechanism Failure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-12-14T10:57:02",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "name": "106185",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/106185"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2018-11460",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "SINUMERIK 808D V4.7 : All versions"
                          },
                          {
                            "version_value": "SINUMERIK 808D V4.8 : All versions"
                          },
                          {
                            "version_value": "SINUMERIK 828D V4.7 : All versions \u003c V4.7 SP6 HF1"
                          },
                          {
                            "version_value": "SINUMERIK 840D sl V4.7 : All versions \u003c V4.7 SP6 HF5"
                          },
                          {
                            "version_value": "SINUMERIK 840D sl V4.8 : All versions \u003c V4.8 SP3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens AG"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions \u003c V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions \u003c V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions \u003c V4.8 SP3). A local attacker with elevated user privileges (manufact) could modify a CRAMFS archive so that after reboot the system loads the modified CRAMFS file and attacker-controlled code is executed with root privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires elevated user privileges (manufact) but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-693: Protection Mechanism Failure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "106185",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/106185"
            },
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2018-11460",
    "datePublished": "2018-12-12T16:00:00",
    "dateReserved": "2018-05-25T00:00:00",
    "dateUpdated": "2024-08-05T08:10:14.579Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2018-11460\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2018-12-12T16:29:00.403\",\"lastModified\":\"2019-10-09T23:33:33.183\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions \u003c V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions \u003c V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions \u003c V4.8 SP3). A local attacker with elevated user privileges (manufact) could modify a CRAMFS archive so that after reboot the system loads the modified CRAMFS file and attacker-controlled code is executed with root privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires elevated user privileges (manufact) but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SINUMERIK 808D V4.7 (todas las versiones), SINUMERIK 808D V4.8 (todas las versiones), SINUMERIK 828D V4.7 (todas las versiones anteriores a la V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (todas las versiones anteriores a la V4.7 SP6 HF5) y SINUMERIK 840D sl V4.8 (todas las versiones anteriores a la V4.8 SP3). Un atacante local con privilegios de usuario elevados (manufact) podr\u00eda modificar un archivo CRAMFS para que, tras el reinicio, el sistema cargue el archivo CRAMFS modificado y se ejecute c\u00f3digo controlado por el atacante con privilegios root. Esta vulnerabilidad de seguridad podr\u00eda ser explotada por atacantes con acceso local al sistema afectado. Su explotaci\u00f3n con \u00e9xito requiere privilegios de usuario elevados (manufact), pero no requiere interacci\u00f3n del usuario. Esta vulnerabilidad podr\u00eda permitir que un atacante comprometa la confidencialidad, integridad y disponibilidad del sistema. En el momento de la publicaci\u00f3n del advisory, no se conoce ninguna explotaci\u00f3n p\u00fablica de la vulnerabilidad de seguridad.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:C/I:C/A:C\",\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\",\"baseScore\":7.2},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":3.9,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-693\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinumerik_808d_v4.7_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C3A4ADF0-33D6-49AA-9F17-594FB2405188\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinumerik_808d_v4.7:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C5B5C872-3E63-4696-BCEB-A4D236EC2B09\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinumerik_808d_v4.8_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9A6EFCCC-87AB-4E71-93D7-206EF6E57AE8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinumerik_808d_v4.8:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"728CA45F-CE23-4EB8-810F-5292ACFD3D62\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinumerik_828d_v4.7_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.7\",\"matchCriteriaId\":\"96A87A16-2670-4751-8B62-9C7ACE6BC705\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinumerik_828d_v4.7:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B5F8425A-13F1-404C-9BF2-E9259BFE9BED\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinumerik_840d_sl_v4.7_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.7\",\"matchCriteriaId\":\"061BC154-7411-4982-B9F8-9A1873099EC5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinumerik_840d_sl_v4.7:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"40B6E241-2FA0-45E0-B64D-F7F41746FF78\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:sinumerik_840d_sl_v4.8_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"4.8\",\"matchCriteriaId\":\"C4E14591-E3AA-4177-814E-3FB4C8F15590\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:sinumerik_840d_sl_v4.8:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1F75930F-4085-4A41-BCB6-930ADB8F0C32\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/106185\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.