CVE-2018-12150 (GCVE-0-2018-12150)

Vulnerability from cvelistv5 – Published: 2018-09-12 19:00 – Updated: 2024-09-17 02:47
VLAI?
Summary
Escalation of privilege in Installer for Intel Extreme Tuning Utility before 6.4.1.21 may allow an authenticated user to potentially execute code or disclose information as administrator via local access.
Severity ?
No CVSS data available.
CWE
  • Escalation of Privilege
Assigner
References
Impacted products
Vendor Product Version
Intel Corporation Intel(R) Extreme Tuning Utility Affected: Versions before 6.4.1.2.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T08:30:57.472Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00162.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Intel(R) Extreme Tuning Utility",
          "vendor": "Intel Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Versions before 6.4.1.2."
            }
          ]
        }
      ],
      "datePublic": "2018-09-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Escalation of privilege in Installer for Intel Extreme Tuning Utility before 6.4.1.21 may allow an authenticated user to potentially execute code or disclose information as administrator via local access."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Escalation of Privilege",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-09-12T18:57:01",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00162.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@intel.com",
          "DATE_PUBLIC": "2018-09-11T00:00:00",
          "ID": "CVE-2018-12150",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Intel(R) Extreme Tuning Utility",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Versions before 6.4.1.2."
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Intel Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Escalation of privilege in Installer for Intel Extreme Tuning Utility before 6.4.1.21 may allow an authenticated user to potentially execute code or disclose information as administrator via local access."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Escalation of Privilege"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00162.html",
              "refsource": "CONFIRM",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00162.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2018-12150",
    "datePublished": "2018-09-12T19:00:00Z",
    "dateReserved": "2018-06-11T00:00:00",
    "dateUpdated": "2024-09-17T02:47:05.665Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:intel:extreme_tuning_utility:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"6.4.1.21\", \"matchCriteriaId\": \"52F7B1BD-018A-443E-8A6C-07BA917E6910\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Escalation of privilege in Installer for Intel Extreme Tuning Utility before 6.4.1.21 may allow an authenticated user to potentially execute code or disclose information as administrator via local access.\"}, {\"lang\": \"es\", \"value\": \"Escalado de privilegios en el instalador de Intel Extreme Tuning Utility en versiones anteriores a la 6.4.1.21 podr\\u00eda permitir que un usuario autenticado ejecute c\\u00f3digo o revele informaci\\u00f3n como administrador mediante acceso local.\"}]",
      "id": "CVE-2018-12150",
      "lastModified": "2024-11-21T03:44:39.697",
      "metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 6.7, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 0.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:P/I:P/A:P\", \"baseScore\": 4.6, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 3.9, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2018-09-12T19:29:01.010",
      "references": "[{\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00162.html\", \"source\": \"secure@intel.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00162.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
      "sourceIdentifier": "secure@intel.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-119\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2018-12150\",\"sourceIdentifier\":\"secure@intel.com\",\"published\":\"2018-09-12T19:29:01.010\",\"lastModified\":\"2024-11-21T03:44:39.697\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Escalation of privilege in Installer for Intel Extreme Tuning Utility before 6.4.1.21 may allow an authenticated user to potentially execute code or disclose information as administrator via local access.\"},{\"lang\":\"es\",\"value\":\"Escalado de privilegios en el instalador de Intel Extreme Tuning Utility en versiones anteriores a la 6.4.1.21 podr\u00eda permitir que un usuario autenticado ejecute c\u00f3digo o revele informaci\u00f3n como administrador mediante acceso local.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.7,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":4.6,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.9,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:intel:extreme_tuning_utility:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"6.4.1.21\",\"matchCriteriaId\":\"52F7B1BD-018A-443E-8A6C-07BA917E6910\"}]}]}],\"references\":[{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00162.html\",\"source\":\"secure@intel.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00162.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…