CVE-2018-13802 (GCVE-0-2018-13802)
Vulnerability from cvelistv5 – Published: 2018-10-10 17:00 – Updated: 2024-09-16 16:39
VLAI?
Summary
A vulnerability has been identified in ROX II (All versions < V2.12.1). An authenticated attacker with a high-privileged user account access via SSH could circumvent restrictions in place and execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the SSH interface in on port 22/tcp. The attacker must be authenticated to exploit the vulnerability. The vulnerability could allow an attacker to execute arbitrary code on the device.
Severity ?
No CVSS data available.
CWE
- CWE-264 - Permissions, Privileges, and Access Controls
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens AG | ROX II |
Affected:
All versions < V2.12.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T09:14:47.316Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-282-03"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-493830.pdf"
},
{
"name": "105545",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/105545"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "ROX II",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.12.1"
}
]
}
],
"datePublic": "2018-10-09T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in ROX II (All versions \u003c V2.12.1). An authenticated attacker with a high-privileged user account access via SSH could circumvent restrictions in place and execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the SSH interface in on port 22/tcp. The attacker must be authenticated to exploit the vulnerability. The vulnerability could allow an attacker to execute arbitrary code on the device."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-264",
"description": "CWE-264: Permissions, Privileges, and Access Controls",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-10-12T09:57:01",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-282-03"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-493830.pdf"
},
{
"name": "105545",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/105545"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"DATE_PUBLIC": "2018-10-09T00:00:00",
"ID": "CVE-2018-13802",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ROX II",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.12.1"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in ROX II (All versions \u003c V2.12.1). An authenticated attacker with a high-privileged user account access via SSH could circumvent restrictions in place and execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the SSH interface in on port 22/tcp. The attacker must be authenticated to exploit the vulnerability. The vulnerability could allow an attacker to execute arbitrary code on the device."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-264: Permissions, Privileges, and Access Controls"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-282-03",
"refsource": "MISC",
"url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-282-03"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-493830.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-493830.pdf"
},
{
"name": "105545",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/105545"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2018-13802",
"datePublished": "2018-10-10T17:00:00Z",
"dateReserved": "2018-07-10T00:00:00",
"dateUpdated": "2024-09-16T16:39:08.335Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:rox_ii_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"2.12.1\", \"matchCriteriaId\": \"60522046-6A22-4087-96D2-A9F825D85CE0\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:rox_ii:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"DA1FB2BC-5AE4-489F-A292-F7820CCB6838\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in ROX II (All versions \u003c V2.12.1). An authenticated attacker with a high-privileged user account access via SSH could circumvent restrictions in place and execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the SSH interface in on port 22/tcp. The attacker must be authenticated to exploit the vulnerability. The vulnerability could allow an attacker to execute arbitrary code on the device.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en ROX II (todas las versiones anteriores a V2.12.1). Un atacante autenticado con acceso a una cuenta de usuario con altos privilegios podr\\u00eda eludir las restricciones existentes y ejecutar comandos arbitrarios del sistema operativo. Su explotaci\\u00f3n con \\u00e9xito requiere que el atacante tenga acceso de red a la interfaz SSH en el puerto 22/tcp. El atacante debe estar autenticado para explotar la vulnerabilidad. La vulnerabilidad podr\\u00eda permitir que el atacante ejecute c\\u00f3digo arbitrario en el dispositivo.\"}]",
"id": "CVE-2018-13802",
"lastModified": "2024-11-21T03:48:04.793",
"metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.2, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.2, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:S/C:C/I:C/A:C\", \"baseScore\": 9.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 8.0, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2018-10-10T17:29:04.000",
"references": "[{\"url\": \"http://www.securityfocus.com/bid/105545\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-493830.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-18-282-03\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"http://www.securityfocus.com/bid/105545\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-493830.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-18-282-03\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}]",
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-264\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-269\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2018-13802\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2018-10-10T17:29:04.000\",\"lastModified\":\"2024-11-21T03:48:04.793\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in ROX II (All versions \u003c V2.12.1). An authenticated attacker with a high-privileged user account access via SSH could circumvent restrictions in place and execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the SSH interface in on port 22/tcp. The attacker must be authenticated to exploit the vulnerability. The vulnerability could allow an attacker to execute arbitrary code on the device.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en ROX II (todas las versiones anteriores a V2.12.1). Un atacante autenticado con acceso a una cuenta de usuario con altos privilegios podr\u00eda eludir las restricciones existentes y ejecutar comandos arbitrarios del sistema operativo. Su explotaci\u00f3n con \u00e9xito requiere que el atacante tenga acceso de red a la interfaz SSH en el puerto 22/tcp. El atacante debe estar autenticado para explotar la vulnerabilidad. La vulnerabilidad podr\u00eda permitir que el atacante ejecute c\u00f3digo arbitrario en el dispositivo.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:C/I:C/A:C\",\"baseScore\":9.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-264\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-269\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:rox_ii_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.12.1\",\"matchCriteriaId\":\"60522046-6A22-4087-96D2-A9F825D85CE0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:rox_ii:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DA1FB2BC-5AE4-489F-A292-F7820CCB6838\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/105545\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-493830.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-18-282-03\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"http://www.securityfocus.com/bid/105545\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-493830.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-18-282-03\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…