CVE-2018-16061 (GCVE-0-2018-16061)
Vulnerability from cvelistv5
Published
2021-10-15 19:04
Modified
2024-09-11 14:15
Severity ?
Summary
Mitsubishi Electric Europe B.V. SmartRTU devices allow XSS via the username parameter or PATH_INFO to login.php.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-05T10:10:05.735Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_refsource_MISC",
                     "x_transferred",
                  ],
                  url: "https://drive.google.com/open?id=1DEZQqfpIgcflY2cF6O0y7vtlWYe8Wjjv",
               },
               {
                  tags: [
                     "x_refsource_MISC",
                     "x_transferred",
                  ],
                  url: "http://packetstormsecurity.com/files/164537/Mitsubishi-Electric-INEA-SmartRTU-Cross-Site-Scripting.html",
               },
            ],
            title: "CVE Program Container",
         },
         {
            metrics: [
               {
                  other: {
                     content: {
                        id: "CVE-2018-16061",
                        options: [
                           {
                              Exploitation: "poc",
                           },
                           {
                              Automatable: "no",
                           },
                           {
                              "Technical Impact": "partial",
                           },
                        ],
                        role: "CISA Coordinator",
                        timestamp: "2024-09-11T14:11:51.263415Z",
                        version: "2.0.3",
                     },
                     type: "ssvc",
                  },
               },
            ],
            providerMetadata: {
               dateUpdated: "2024-09-11T14:15:21.830Z",
               orgId: "134c704f-9b21-4f2e-91b3-4a467353bcc0",
               shortName: "CISA-ADP",
            },
            title: "CISA ADP Vulnrichment",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "Mitsubishi Electric Europe B.V. SmartRTU devices allow XSS via the username parameter or PATH_INFO to login.php.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-09-10T17:01:21.915064",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://drive.google.com/open?id=1DEZQqfpIgcflY2cF6O0y7vtlWYe8Wjjv",
            },
            {
               url: "http://packetstormsecurity.com/files/164537/Mitsubishi-Electric-INEA-SmartRTU-Cross-Site-Scripting.html",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2018-16061",
      datePublished: "2021-10-15T19:04:31",
      dateReserved: "2018-08-28T00:00:00",
      dateUpdated: "2024-09-11T14:15:21.830Z",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
   "vulnerability-lookup:meta": {
      fkie_nvd: {
         configurations: "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:mitsubishielectric:smartrtu_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FC7E0EA8-7CB5-4F64-93D0-849B21863342\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:mitsubishielectric:smartrtu:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1EF90DA0-55C7-4765-9DEE-80145752961D\"}]}]}]",
         descriptions: "[{\"lang\": \"en\", \"value\": \"Mitsubishi Electric Europe B.V. SmartRTU devices allow XSS via the username parameter or PATH_INFO to login.php.\"}, {\"lang\": \"es\", \"value\": \"Los dispositivos Mitsubishi Electric SmartRTU permiten un ataque de tipo XSS por medio del par\\u00e1metro username o PATH_INFO a el archivo login.php\"}]",
         id: "CVE-2018-16061",
         lastModified: "2024-11-21T03:52:01.507",
         metrics: "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 6.1, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 2.7}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:N/I:P/A:N\", \"baseScore\": 4.3, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
         published: "2021-10-15T20:15:07.720",
         references: "[{\"url\": \"http://packetstormsecurity.com/files/164537/Mitsubishi-Electric-INEA-SmartRTU-Cross-Site-Scripting.html\", \"source\": \"cve@mitre.org\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://drive.google.com/open?id=1DEZQqfpIgcflY2cF6O0y7vtlWYe8Wjjv\", \"source\": \"cve@mitre.org\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"http://packetstormsecurity.com/files/164537/Mitsubishi-Electric-INEA-SmartRTU-Cross-Site-Scripting.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://drive.google.com/open?id=1DEZQqfpIgcflY2cF6O0y7vtlWYe8Wjjv\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}]",
         sourceIdentifier: "cve@mitre.org",
         vulnStatus: "Modified",
         weaknesses: "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]",
      },
      nvd: "{\"cve\":{\"id\":\"CVE-2018-16061\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2021-10-15T20:15:07.720\",\"lastModified\":\"2024-11-21T03:52:01.507\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Mitsubishi Electric Europe B.V. SmartRTU devices allow XSS via the username parameter or PATH_INFO to login.php.\"},{\"lang\":\"es\",\"value\":\"Los dispositivos Mitsubishi Electric SmartRTU permiten un ataque de tipo XSS por medio del parámetro username o PATH_INFO a el archivo login.php\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:P/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:smartrtu_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FC7E0EA8-7CB5-4F64-93D0-849B21863342\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:smartrtu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1EF90DA0-55C7-4765-9DEE-80145752961D\"}]}]}],\"references\":[{\"url\":\"http://packetstormsecurity.com/files/164537/Mitsubishi-Electric-INEA-SmartRTU-Cross-Site-Scripting.html\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://drive.google.com/open?id=1DEZQqfpIgcflY2cF6O0y7vtlWYe8Wjjv\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"http://packetstormsecurity.com/files/164537/Mitsubishi-Electric-INEA-SmartRTU-Cross-Site-Scripting.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://drive.google.com/open?id=1DEZQqfpIgcflY2cF6O0y7vtlWYe8Wjjv\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}",
      vulnrichment: {
         containers: "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://drive.google.com/open?id=1DEZQqfpIgcflY2cF6O0y7vtlWYe8Wjjv\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}, {\"url\": \"http://packetstormsecurity.com/files/164537/Mitsubishi-Electric-INEA-SmartRTU-Cross-Site-Scripting.html\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-05T10:10:05.735Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2018-16061\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-09-11T14:11:51.263415Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-09-11T14:15:16.906Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"references\": [{\"url\": \"https://drive.google.com/open?id=1DEZQqfpIgcflY2cF6O0y7vtlWYe8Wjjv\"}, {\"url\": \"http://packetstormsecurity.com/files/164537/Mitsubishi-Electric-INEA-SmartRTU-Cross-Site-Scripting.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"Mitsubishi Electric Europe B.V. SmartRTU devices allow XSS via the username parameter or PATH_INFO to login.php.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"n/a\"}]}], \"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2024-09-10T17:01:21.915064\"}}}",
         cveMetadata: "{\"cveId\": \"CVE-2018-16061\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-09-11T14:15:21.830Z\", \"dateReserved\": \"2018-08-28T00:00:00\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"datePublished\": \"2021-10-15T19:04:31\", \"assignerShortName\": \"mitre\"}",
         dataType: "CVE_RECORD",
         dataVersion: "5.1",
      },
   },
}


Log in or create an account to share your comment.

Security Advisory comment format.

This schema specifies the format of a comment related to a security advisory.

UUIDv4 of the comment
UUIDv4 of the Vulnerability-Lookup instance
When the comment was created originally
When the comment was last updated
Title of the comment
Description of the comment
The identifier of the vulnerability (CVE ID, GHSA-ID, PYSEC ID, etc.).



Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.