Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2018-16417 (GCVE-0-2018-16417)
Vulnerability from cvelistv5 – Published: 2019-10-30 16:26 – Updated: 2024-08-05 10:24- n/a
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T10:24:32.103Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf"
},
{
"name": "108374",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/108374"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-07"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.anquanke.com/vul/id/1652568"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-10-30T16:28:13",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf"
},
{
"name": "108374",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/108374"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-07"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.anquanke.com/vul/id/1652568"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-16417",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt",
"refsource": "CONFIRM",
"url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf"
},
{
"name": "108374",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/108374"
},
{
"name": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-07",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-07"
},
{
"name": "https://www.anquanke.com/vul/id/1652568",
"refsource": "MISC",
"url": "https://www.anquanke.com/vul/id/1652568"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-16417",
"datePublished": "2019-10-30T16:26:32",
"dateReserved": "2018-09-03T00:00:00",
"dateUpdated": "2024-08-05T10:24:32.103Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"4.0.0.0\", \"versionEndExcluding\": \"4.2.4.12\", \"matchCriteriaId\": \"EC2CC454-39A5-4D56-BB87-DF9B48303FFB\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"6.5.0.0\", \"versionEndExcluding\": \"6.5.4.11\", \"matchCriteriaId\": \"615BA62B-7BA9-43DA-A4A8-E83F81513EC3\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"8.3.0.0\", \"versionEndExcluding\": \"8.3.0.6\", \"matchCriteriaId\": \"B16A6954-EB81-4BB4-B612-D02415AEE765\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*\", \"versionStartIncluding\": \"8.4.0.0\", \"versionEndExcluding\": \"8.4.0.1\", \"matchCriteriaId\": \"715B7F25-4EFA-4BA6-995B-9E84C59116EC\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:w1750d_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"8.4.0.1\", \"matchCriteriaId\": \"AFBFE706-F452-4018-85AE-855B971CE206\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:w1750d:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9DF5733F-79FB-4EBB-AC5B-BA4B75A80AB3\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection.\"}, {\"lang\": \"es\", \"value\": \"Aruba Instant versiones 4.x anteriores a la versi\\u00f3n 6.4.4.8-4.2.4.12, versiones 6.5.x anteriores a la versi\\u00f3n 6.5.4.11, versiones 8.3.x anteriores a 8.3.0.6 y versiones 8.4.x anteriores a la versi\\u00f3n 8.4.0.1, permite una Inyecci\\u00f3n de Comandos.\"}]",
"id": "CVE-2018-16417",
"lastModified": "2024-11-21T03:52:42.423",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:N/A:N\", \"baseScore\": 5.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2019-10-30T17:15:11.877",
"references": "[{\"url\": \"http://www.securityfocus.com/bid/108374\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.anquanke.com/vul/id/1652568\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt\", \"source\": \"cve@mitre.org\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.us-cert.gov/ics/advisories/ICSA-19-134-07\", \"source\": \"cve@mitre.org\", \"tags\": [\"Mitigation\", \"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"http://www.securityfocus.com/bid/108374\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.anquanke.com/vul/id/1652568\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.us-cert.gov/ics/advisories/ICSA-19-134-07\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mitigation\", \"Third Party Advisory\", \"US Government Resource\"]}]",
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-77\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2018-16417\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2019-10-30T17:15:11.877\",\"lastModified\":\"2024-11-21T03:52:42.423\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection.\"},{\"lang\":\"es\",\"value\":\"Aruba Instant versiones 4.x anteriores a la versi\u00f3n 6.4.4.8-4.2.4.12, versiones 6.5.x anteriores a la versi\u00f3n 6.5.4.11, versiones 8.3.x anteriores a 8.3.0.6 y versiones 8.4.x anteriores a la versi\u00f3n 8.4.0.1, permite una Inyecci\u00f3n de Comandos.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"4.0.0.0\",\"versionEndExcluding\":\"4.2.4.12\",\"matchCriteriaId\":\"EC2CC454-39A5-4D56-BB87-DF9B48303FFB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.5.0.0\",\"versionEndExcluding\":\"6.5.4.11\",\"matchCriteriaId\":\"615BA62B-7BA9-43DA-A4A8-E83F81513EC3\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.3.0.0\",\"versionEndExcluding\":\"8.3.0.6\",\"matchCriteriaId\":\"B16A6954-EB81-4BB4-B612-D02415AEE765\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"8.4.0.0\",\"versionEndExcluding\":\"8.4.0.1\",\"matchCriteriaId\":\"715B7F25-4EFA-4BA6-995B-9E84C59116EC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:w1750d_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.4.0.1\",\"matchCriteriaId\":\"AFBFE706-F452-4018-85AE-855B971CE206\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:w1750d:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9DF5733F-79FB-4EBB-AC5B-BA4B75A80AB3\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/108374\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.anquanke.com/vul/id/1652568\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/ICSA-19-134-07\",\"source\":\"cve@mitre.org\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"http://www.securityfocus.com/bid/108374\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.anquanke.com/vul/id/1652568\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/ICSA-19-134-07\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]}]}}"
}
}
CERTFR-2019-AVI-083
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans Aruba Instant. Elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, une atteinte à la confidentialité des données et une injection de code indirecte à distance (XSS).
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Title | Publication Time | Tags | |||
|---|---|---|---|---|---|
|
|||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Aruba Instant 6.5.x versions ant\u00e9rieures \u00e0 6.5.4.11",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Aruba Instant 8.3.x versions ant\u00e9rieures \u00e0 8.3.0.6",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Aruba Instant 4.x versions ant\u00e9rieures \u00e0 4.2.4.12",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Aruba Instant 8.4.x versions ant\u00e9rieures \u00e0 8.4.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2018-7083",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7083"
},
{
"name": "CVE-2018-16417",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-16417"
},
{
"name": "CVE-2018-7064",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7064"
},
{
"name": "CVE-2018-7084",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7084"
},
{
"name": "CVE-2018-7082",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7082"
}
],
"links": [],
"reference": "CERTFR-2019-AVI-083",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2019-02-28T00:00:00.000000"
}
],
"risks": [
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans Aruba Instant.\nElles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code\narbitraire \u00e0 distance, une atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es et\nune injection de code indirecte \u00e0 distance (XSS).\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans Aruba Instant",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Aruba ARUBA-PSA-2019-001 du 27 f\u00e9vrier 2019",
"url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt"
}
]
}
CERTFR-2019-AVI-207
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SIMATIC HMI Comfort Outdoor Panels 7" & 15" versions antérieures à V15.1 Update 1 | ||
| Siemens | N/A | SIMATIC HMI Comfort Panels 4" - 22" versions antérieures à V15.1 Update 1 | ||
| Siemens | N/A | SIMATIC WinCC (TIA Portal) versions antérieures à V15.1 Update 1 | ||
| Siemens | N/A | SISHIP IPMS | ||
| Siemens | N/A | SIMATIC PCS 7 | ||
| Siemens | N/A | LOGO! Soft Comfort | ||
| Siemens | N/A | LOGO!8 BM | ||
| Siemens | N/A | SIMATIC HMI KTP Mobile Panels KTP400F,KTP700, KTP700F, KTP900 et KTP900F versions antérieures à V15.1 Update 1 | ||
| Siemens | N/A | SIMATIC WinCC V7.5 versions antérieures à V7.5 Upd3 | ||
| Siemens | N/A | SIMATIC HMI Classic Devices (TP/MP/OP/MPMobile Panel) | ||
| Siemens | N/A | SINAMICS PERFECT HARMONY GH180 | ||
| Siemens | N/A | SISHIP IMAC | ||
| Siemens | N/A | SISHIP EMCS | ||
| Siemens | N/A | SIMATIC WinCC Runtime Advanced versions antérieures à V15.1 Update 1 | ||
| Siemens | N/A | SCALANCE W1750D versions antérieures à V8.4.0.1 | ||
| Siemens | N/A | SIMATIC WinCC Runtime Professional versions antérieures à V15.1 Update 1 |
| Title | Publication Time | Tags | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" versions ant\u00e9rieures \u00e0 V15.1 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI Comfort Panels 4\" - 22\" versions ant\u00e9rieures \u00e0 V15.1 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC (TIA Portal) versions ant\u00e9rieures \u00e0 V15.1 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SISHIP IPMS",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PCS 7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "LOGO! Soft Comfort",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "LOGO!8 BM",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI KTP Mobile Panels KTP400F,KTP700, KTP700F, KTP900 et KTP900F versions ant\u00e9rieures \u00e0 V15.1 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC V7.5 versions ant\u00e9rieures \u00e0 V7.5 Upd3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI Classic Devices (TP/MP/OP/MPMobile Panel)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS PERFECT HARMONY GH180",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SISHIP IMAC",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SISHIP EMCS",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC Runtime Advanced versions ant\u00e9rieures \u00e0 V15.1 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1750D versions ant\u00e9rieures \u00e0 V8.4.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC Runtime Professional versions ant\u00e9rieures \u00e0 V15.1 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2018-7083",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7083"
},
{
"name": "CVE-2019-10919",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10919"
},
{
"name": "CVE-2019-10920",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10920"
},
{
"name": "CVE-2019-6572",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6572"
},
{
"name": "CVE-2018-16417",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-16417"
},
{
"name": "CVE-2018-3991",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-3991"
},
{
"name": "CVE-2019-10916",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10916"
},
{
"name": "CVE-2018-3990",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-3990"
},
{
"name": "CVE-2018-3989",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-3989"
},
{
"name": "CVE-2019-10922",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10922"
},
{
"name": "CVE-2019-10921",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10921"
},
{
"name": "CVE-2019-10924",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10924"
},
{
"name": "CVE-2019-10918",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10918"
},
{
"name": "CVE-2019-10917",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10917"
},
{
"name": "CVE-2018-7064",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7064"
},
{
"name": "CVE-2019-6578",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6578"
},
{
"name": "CVE-2018-7084",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7084"
},
{
"name": "CVE-2019-6576",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6576"
},
{
"name": "CVE-2019-6577",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6577"
},
{
"name": "CVE-2019-6574",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6574"
},
{
"name": "CVE-2018-7082",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7082"
}
],
"links": [],
"reference": "CERTFR-2019-AVI-207",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2019-05-14T00:00:00.000000"
},
{
"description": "Ajout de SCADA dans le titre.",
"revision_date": "2019-05-15T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-705517 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705517.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-865156 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865156.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-902727 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-902727.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-606525 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-606525.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-549547 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-697412 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-804486 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-102144 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-102144.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-542701 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf"
}
]
}
CERTFR-2019-AVI-083
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans Aruba Instant. Elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, une atteinte à la confidentialité des données et une injection de code indirecte à distance (XSS).
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Title | Publication Time | Tags | |||
|---|---|---|---|---|---|
|
|||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Aruba Instant 6.5.x versions ant\u00e9rieures \u00e0 6.5.4.11",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Aruba Instant 8.3.x versions ant\u00e9rieures \u00e0 8.3.0.6",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Aruba Instant 4.x versions ant\u00e9rieures \u00e0 4.2.4.12",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Aruba Instant 8.4.x versions ant\u00e9rieures \u00e0 8.4.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2018-7083",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7083"
},
{
"name": "CVE-2018-16417",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-16417"
},
{
"name": "CVE-2018-7064",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7064"
},
{
"name": "CVE-2018-7084",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7084"
},
{
"name": "CVE-2018-7082",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7082"
}
],
"links": [],
"reference": "CERTFR-2019-AVI-083",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2019-02-28T00:00:00.000000"
}
],
"risks": [
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans Aruba Instant.\nElles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de code\narbitraire \u00e0 distance, une atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es et\nune injection de code indirecte \u00e0 distance (XSS).\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans Aruba Instant",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Aruba ARUBA-PSA-2019-001 du 27 f\u00e9vrier 2019",
"url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt"
}
]
}
CERTFR-2019-AVI-207
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SIMATIC HMI Comfort Outdoor Panels 7" & 15" versions antérieures à V15.1 Update 1 | ||
| Siemens | N/A | SIMATIC HMI Comfort Panels 4" - 22" versions antérieures à V15.1 Update 1 | ||
| Siemens | N/A | SIMATIC WinCC (TIA Portal) versions antérieures à V15.1 Update 1 | ||
| Siemens | N/A | SISHIP IPMS | ||
| Siemens | N/A | SIMATIC PCS 7 | ||
| Siemens | N/A | LOGO! Soft Comfort | ||
| Siemens | N/A | LOGO!8 BM | ||
| Siemens | N/A | SIMATIC HMI KTP Mobile Panels KTP400F,KTP700, KTP700F, KTP900 et KTP900F versions antérieures à V15.1 Update 1 | ||
| Siemens | N/A | SIMATIC WinCC V7.5 versions antérieures à V7.5 Upd3 | ||
| Siemens | N/A | SIMATIC HMI Classic Devices (TP/MP/OP/MPMobile Panel) | ||
| Siemens | N/A | SINAMICS PERFECT HARMONY GH180 | ||
| Siemens | N/A | SISHIP IMAC | ||
| Siemens | N/A | SISHIP EMCS | ||
| Siemens | N/A | SIMATIC WinCC Runtime Advanced versions antérieures à V15.1 Update 1 | ||
| Siemens | N/A | SCALANCE W1750D versions antérieures à V8.4.0.1 | ||
| Siemens | N/A | SIMATIC WinCC Runtime Professional versions antérieures à V15.1 Update 1 |
| Title | Publication Time | Tags | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" versions ant\u00e9rieures \u00e0 V15.1 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI Comfort Panels 4\" - 22\" versions ant\u00e9rieures \u00e0 V15.1 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC (TIA Portal) versions ant\u00e9rieures \u00e0 V15.1 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SISHIP IPMS",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PCS 7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "LOGO! Soft Comfort",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "LOGO!8 BM",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI KTP Mobile Panels KTP400F,KTP700, KTP700F, KTP900 et KTP900F versions ant\u00e9rieures \u00e0 V15.1 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC V7.5 versions ant\u00e9rieures \u00e0 V7.5 Upd3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC HMI Classic Devices (TP/MP/OP/MPMobile Panel)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS PERFECT HARMONY GH180",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SISHIP IMAC",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SISHIP EMCS",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC Runtime Advanced versions ant\u00e9rieures \u00e0 V15.1 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1750D versions ant\u00e9rieures \u00e0 V8.4.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC Runtime Professional versions ant\u00e9rieures \u00e0 V15.1 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2018-7083",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7083"
},
{
"name": "CVE-2019-10919",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10919"
},
{
"name": "CVE-2019-10920",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10920"
},
{
"name": "CVE-2019-6572",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6572"
},
{
"name": "CVE-2018-16417",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-16417"
},
{
"name": "CVE-2018-3991",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-3991"
},
{
"name": "CVE-2019-10916",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10916"
},
{
"name": "CVE-2018-3990",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-3990"
},
{
"name": "CVE-2018-3989",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-3989"
},
{
"name": "CVE-2019-10922",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10922"
},
{
"name": "CVE-2019-10921",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10921"
},
{
"name": "CVE-2019-10924",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10924"
},
{
"name": "CVE-2019-10918",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10918"
},
{
"name": "CVE-2019-10917",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10917"
},
{
"name": "CVE-2018-7064",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7064"
},
{
"name": "CVE-2019-6578",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6578"
},
{
"name": "CVE-2018-7084",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7084"
},
{
"name": "CVE-2019-6576",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6576"
},
{
"name": "CVE-2019-6577",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6577"
},
{
"name": "CVE-2019-6574",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6574"
},
{
"name": "CVE-2018-7082",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7082"
}
],
"links": [],
"reference": "CERTFR-2019-AVI-207",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2019-05-14T00:00:00.000000"
},
{
"description": "Ajout de SCADA dans le titre.",
"revision_date": "2019-05-15T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-705517 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705517.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-865156 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-865156.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-902727 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-902727.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-606525 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-606525.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-549547 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-697412 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-697412.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-804486 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-804486.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-102144 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-102144.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-542701 du 14 mai 2019",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-542701.pdf"
}
]
}
GHSA-CX84-R7H4-7PFJ
Vulnerability from github – Published: 2022-05-24 17:00 – Updated: 2024-04-04 02:36Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection.
{
"affected": [],
"aliases": [
"CVE-2018-16417"
],
"database_specific": {
"cwe_ids": [
"CWE-77"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2019-10-30T17:15:00Z",
"severity": "HIGH"
},
"details": "Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection.",
"id": "GHSA-cx84-r7h4-7pfj",
"modified": "2024-04-04T02:36:26Z",
"published": "2022-05-24T17:00:06Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2018-16417"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf"
},
{
"type": "WEB",
"url": "https://www.anquanke.com/vul/id/1652568"
},
{
"type": "WEB",
"url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt"
},
{
"type": "WEB",
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-07"
},
{
"type": "WEB",
"url": "http://www.securityfocus.com/bid/108374"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"type": "CVSS_V3"
}
]
}
FKIE_CVE-2018-16417
Vulnerability from fkie_nvd - Published: 2019-10-30 17:15 - Updated: 2024-11-21 03:52| Vendor | Product | Version | |
|---|---|---|---|
| arubanetworks | instant | * | |
| arubanetworks | instant | * | |
| arubanetworks | instant | * | |
| arubanetworks | instant | * | |
| siemens | w1750d_firmware | * | |
| siemens | w1750d | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*",
"matchCriteriaId": "EC2CC454-39A5-4D56-BB87-DF9B48303FFB",
"versionEndExcluding": "4.2.4.12",
"versionStartIncluding": "4.0.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*",
"matchCriteriaId": "615BA62B-7BA9-43DA-A4A8-E83F81513EC3",
"versionEndExcluding": "6.5.4.11",
"versionStartIncluding": "6.5.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B16A6954-EB81-4BB4-B612-D02415AEE765",
"versionEndExcluding": "8.3.0.6",
"versionStartIncluding": "8.3.0.0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*",
"matchCriteriaId": "715B7F25-4EFA-4BA6-995B-9E84C59116EC",
"versionEndExcluding": "8.4.0.1",
"versionStartIncluding": "8.4.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:w1750d_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AFBFE706-F452-4018-85AE-855B971CE206",
"versionEndExcluding": "8.4.0.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:w1750d:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9DF5733F-79FB-4EBB-AC5B-BA4B75A80AB3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection."
},
{
"lang": "es",
"value": "Aruba Instant versiones 4.x anteriores a la versi\u00f3n 6.4.4.8-4.2.4.12, versiones 6.5.x anteriores a la versi\u00f3n 6.5.4.11, versiones 8.3.x anteriores a 8.3.0.6 y versiones 8.4.x anteriores a la versi\u00f3n 8.4.0.1, permite una Inyecci\u00f3n de Comandos."
}
],
"id": "CVE-2018-16417",
"lastModified": "2024-11-21T03:52:42.423",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-10-30T17:15:11.877",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/108374"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://www.anquanke.com/vul/id/1652568"
},
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt"
},
{
"source": "cve@mitre.org",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-07"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/108374"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.anquanke.com/vul/id/1652568"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-07"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
GSD-2018-16417
Vulnerability from gsd - Updated: 2023-12-13 01:22{
"GSD": {
"alias": "CVE-2018-16417",
"description": "Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection.",
"id": "GSD-2018-16417"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2018-16417"
],
"details": "Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection.",
"id": "GSD-2018-16417",
"modified": "2023-12-13T01:22:26.160032Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-16417",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt",
"refsource": "CONFIRM",
"url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf"
},
{
"name": "108374",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/108374"
},
{
"name": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-07",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-07"
},
{
"name": "https://www.anquanke.com/vul/id/1652568",
"refsource": "MISC",
"url": "https://www.anquanke.com/vul/id/1652568"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.2.4.12",
"versionStartIncluding": "4.0.0.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "8.4.0.1",
"versionStartIncluding": "8.4.0.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "8.3.0.6",
"versionStartIncluding": "8.3.0.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.5.4.11",
"versionStartIncluding": "6.5.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:w1750d_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "8.4.0.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:w1750d:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-16417"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.anquanke.com/vul/id/1652568",
"refsource": "MISC",
"tags": [
"Third Party Advisory"
],
"url": "https://www.anquanke.com/vul/id/1652568"
},
{
"name": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-07",
"refsource": "MISC",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.us-cert.gov/ics/advisories/ICSA-19-134-07"
},
{
"name": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt",
"refsource": "CONFIRM",
"tags": [
"Vendor Advisory"
],
"url": "https://www.arubanetworks.com/assets/alert/ARUBA-PSA-2019-001.txt"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf",
"refsource": "CONFIRM",
"tags": [
"Third Party Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf"
},
{
"name": "108374",
"refsource": "BID",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://www.securityfocus.com/bid/108374"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
},
"lastModifiedDate": "2020-08-24T17:37Z",
"publishedDate": "2019-10-30T17:15Z"
}
}
}
CNVD-2019-06344
Vulnerability from cnvd - Published: 2019-03-06目前厂商暂未发布修复措施解决此安全问题,建议使用此软件的用户随时关注厂商主页或参考网址以获取解决办法: https://www.al-enterprise.com/
| Name | ALE Alcatel OmniAccess Wireless Access Point |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2018-16417"
}
},
"description": "ALE Alcatel OmniAccess Wireless Access Point\u662f\u6cd5\u56fdALE\u516c\u53f8\u7684\u4e00\u6b3e\u65e0\u7ebf\u63a5\u5165\u70b9\u8bbe\u5907\u3002\n\nALE Alcatel OmniAccess Wireless Access Point\u4e2d\u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\u3002\u653b\u51fb\u8005\u53ef\u901a\u8fc7\u53d1\u9001\u7279\u5236\u7684URL\u5229\u7528\u8be5\u6f0f\u6d1e\u67e5\u770b\u914d\u7f6e\u547d\u4ee4\u3002",
"discovererName": "unknwon",
"formalWay": "\u76ee\u524d\u5382\u5546\u6682\u672a\u53d1\u5e03\u4fee\u590d\u63aa\u65bd\u89e3\u51b3\u6b64\u5b89\u5168\u95ee\u9898\uff0c\u5efa\u8bae\u4f7f\u7528\u6b64\u8f6f\u4ef6\u7684\u7528\u6237\u968f\u65f6\u5173\u6ce8\u5382\u5546\u4e3b\u9875\u6216\u53c2\u8003\u7f51\u5740\u4ee5\u83b7\u53d6\u89e3\u51b3\u529e\u6cd5\uff1a\r\nhttps://www.al-enterprise.com/",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2019-06344",
"openTime": "2019-03-06",
"products": {
"product": "ALE Alcatel OmniAccess Wireless Access Point"
},
"referenceLink": "https://vigilance.fr/vulnerability/Alcatel-Lucent-Enterprise-OmniAccess-WLAN-Instant-multiple-vulnerabilities-28646",
"serverity": "\u4e2d",
"submitTime": "2019-03-06",
"title": "ALE Alcatel OmniAccess Wireless Access Point\u4fe1\u606f\u6cc4\u9732\u6f0f\u6d1e"
}
VAR-201910-1493
Vulnerability from variot - Updated: 2023-12-18 12:28Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection. Aruba Instant Contains an injection vulnerability.Information may be obtained. ALEAlcatelOmniAccessWirelessAccessPoint is a wireless access point device from ALE France. A security vulnerability exists in ALEAlcatelOmniAccessWirelessAccessPoint. An attacker could exploit the vulnerability to view configuration commands by sending a specially crafted URL. Siemens SCALANCE W1750D is prone to following security vulnerabilities: 1. Multiple information disclosure vulnerabilities 2. Multiple remote command injection vulnerabilities Attackers can exploit these issues to obtain sensitive information, or execute arbitrary commands or arbitrary HTML or script code in the browser of an unsuspecting user within the context of the affected application. This can allow the attacker to steal cookie-based authentication credentials and aid in further attacks. Versions prior to SCALANCE W1750D 8.4.0.1 are vulnerable
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-201910-1493",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "instant",
"scope": "lt",
"trust": 1.0,
"vendor": "arubanetworks",
"version": "8.4.0.1"
},
{
"model": "instant",
"scope": "lt",
"trust": 1.0,
"vendor": "arubanetworks",
"version": "6.5.4.11"
},
{
"model": "instant",
"scope": "gte",
"trust": 1.0,
"vendor": "arubanetworks",
"version": "8.3.0.0"
},
{
"model": "instant",
"scope": "gte",
"trust": 1.0,
"vendor": "arubanetworks",
"version": "8.4.0.0"
},
{
"model": "instant",
"scope": "gte",
"trust": 1.0,
"vendor": "arubanetworks",
"version": "4.0.0.0"
},
{
"model": "instant",
"scope": "lt",
"trust": 1.0,
"vendor": "arubanetworks",
"version": "8.3.0.6"
},
{
"model": "instant",
"scope": "gte",
"trust": 1.0,
"vendor": "arubanetworks",
"version": "6.5.0.0"
},
{
"model": "instant",
"scope": "lt",
"trust": 1.0,
"vendor": "arubanetworks",
"version": "4.2.4.12"
},
{
"model": "w1750d",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "8.4.0.1"
},
{
"model": "instant",
"scope": "lt",
"trust": 0.8,
"vendor": "aruba",
"version": "8.4.x"
},
{
"model": "instant",
"scope": "eq",
"trust": 0.8,
"vendor": "aruba",
"version": "8.4.0.1"
},
{
"model": "instant",
"scope": "eq",
"trust": 0.8,
"vendor": "aruba",
"version": "8.3.0.6"
},
{
"model": "instant",
"scope": "eq",
"trust": 0.8,
"vendor": "aruba",
"version": "6.5.4.11"
},
{
"model": "instant",
"scope": "lt",
"trust": 0.8,
"vendor": "aruba",
"version": "8.3.x"
},
{
"model": "instant",
"scope": "eq",
"trust": 0.8,
"vendor": "aruba",
"version": "6.4.4.8-4.2.4.12"
},
{
"model": "w1750d",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "instant",
"scope": "lt",
"trust": 0.8,
"vendor": "aruba",
"version": "4.x"
},
{
"model": "instant",
"scope": "lt",
"trust": 0.8,
"vendor": "aruba",
"version": "6.5.x"
},
{
"model": "alcatel omniaccess wireless access point",
"scope": null,
"trust": 0.6,
"vendor": "ale",
"version": null
},
{
"model": "scalance w1750d",
"scope": "eq",
"trust": 0.3,
"vendor": "siemens",
"version": "0"
},
{
"model": "scalance w1750d",
"scope": "ne",
"trust": 0.3,
"vendor": "siemens",
"version": "8.4.0.1"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-06344"
},
{
"db": "BID",
"id": "108374"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016143"
},
{
"db": "NVD",
"id": "CVE-2018-16417"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "4.2.4.12",
"versionStartIncluding": "4.0.0.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "8.4.0.1",
"versionStartIncluding": "8.4.0.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "8.3.0.6",
"versionStartIncluding": "8.3.0.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:o:arubanetworks:instant:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "6.5.4.11",
"versionStartIncluding": "6.5.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:w1750d_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "8.4.0.1",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:w1750d:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2018-16417"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Siemens reported these vulnerabilities to NCCIC.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201903-052"
}
],
"trust": 0.6
},
"cve": "CVE-2018-16417",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"integrityImpact": "NONE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 5.0,
"confidentialityImpact": "Partial",
"exploitabilityScore": null,
"id": "CVE-2018-16417",
"impactScore": null,
"integrityImpact": "None",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"exploitabilityScore": 10.0,
"id": "CNVD-2019-06344",
"impactScore": 2.9,
"integrityImpact": "NONE",
"severity": "MEDIUM",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 7.5,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2018-16417",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2018-16417",
"trust": 1.8,
"value": "HIGH"
},
{
"author": "CNVD",
"id": "CNVD-2019-06344",
"trust": 0.6,
"value": "MEDIUM"
},
{
"author": "CNNVD",
"id": "CNNVD-201903-052",
"trust": 0.6,
"value": "HIGH"
},
{
"author": "VULMON",
"id": "CVE-2018-16417",
"trust": 0.1,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-06344"
},
{
"db": "VULMON",
"id": "CVE-2018-16417"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016143"
},
{
"db": "NVD",
"id": "CVE-2018-16417"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-052"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Aruba Instant 4.x prior to 6.4.4.8-4.2.4.12, 6.5.x prior to 6.5.4.11, 8.3.x prior to 8.3.0.6, and 8.4.x prior to 8.4.0.1 allows Command injection. Aruba Instant Contains an injection vulnerability.Information may be obtained. ALEAlcatelOmniAccessWirelessAccessPoint is a wireless access point device from ALE France. A security vulnerability exists in ALEAlcatelOmniAccessWirelessAccessPoint. An attacker could exploit the vulnerability to view configuration commands by sending a specially crafted URL. Siemens SCALANCE W1750D is prone to following security vulnerabilities:\n1. Multiple information disclosure vulnerabilities\n2. Multiple remote command injection vulnerabilities\nAttackers can exploit these issues to obtain sensitive information, or execute arbitrary commands or arbitrary HTML or script code in the browser of an unsuspecting user within the context of the affected application. This can allow the attacker to steal cookie-based authentication credentials and aid in further attacks. \nVersions prior to SCALANCE W1750D 8.4.0.1 are vulnerable",
"sources": [
{
"db": "NVD",
"id": "CVE-2018-16417"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016143"
},
{
"db": "CNVD",
"id": "CNVD-2019-06344"
},
{
"db": "BID",
"id": "108374"
},
{
"db": "VULMON",
"id": "CVE-2018-16417"
}
],
"trust": 2.52
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2018-16417",
"trust": 3.4
},
{
"db": "ICS CERT",
"id": "ICSA-19-134-07",
"trust": 2.8
},
{
"db": "BID",
"id": "108374",
"trust": 2.0
},
{
"db": "SIEMENS",
"id": "SSA-549547",
"trust": 1.7
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016143",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2019-06344",
"trust": 0.6
},
{
"db": "ICS CERT",
"id": "ICSA-19-134-02",
"trust": 0.6
},
{
"db": "AUSCERT",
"id": "ESB-2019.1716.2",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-201903-052",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2018-16417",
"trust": 0.1
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-06344"
},
{
"db": "VULMON",
"id": "CVE-2018-16417"
},
{
"db": "BID",
"id": "108374"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016143"
},
{
"db": "NVD",
"id": "CVE-2018-16417"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-052"
}
]
},
"id": "VAR-201910-1493",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-06344"
}
],
"trust": 1.6
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-06344"
}
]
},
"last_update_date": "2023-12-18T12:28:15.916000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "ARUBA-PSA-2019-001",
"trust": 0.8,
"url": "https://www.arubanetworks.com/assets/alert/aruba-psa-2019-001.txt"
},
{
"title": "SSA-549547",
"trust": 0.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf"
},
{
"title": "Siemens Security Advisories: Siemens Security Advisory",
"trust": 0.1,
"url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=f04f471bbc12c6e00cc683978d7f0589"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2018-16417"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016143"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-77",
"trust": 1.0
},
{
"problemtype": "CWE-74",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-016143"
},
{
"db": "NVD",
"id": "CVE-2018-16417"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 3.0,
"url": "http://www.securityfocus.com/bid/108374"
},
{
"trust": 2.5,
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-134-07"
},
{
"trust": 1.7,
"url": "https://www.anquanke.com/vul/id/1652568"
},
{
"trust": 1.7,
"url": "https://www.arubanetworks.com/assets/alert/aruba-psa-2019-001.txt"
},
{
"trust": 1.7,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-549547.pdf"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2018-16417"
},
{
"trust": 1.2,
"url": "https://vigilance.fr/vulnerability/alcatel-lucent-enterprise-omniaccess-wlan-instant-multiple-vulnerabilities-28646"
},
{
"trust": 1.0,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-19-134-07"
},
{
"trust": 0.9,
"url": "http://www.siemens.com/"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-16417"
},
{
"trust": 0.6,
"url": "https://ics-cert.us-cert.gov/advisories/icsa-19-134-02-0"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/80946"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/77.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2019-06344"
},
{
"db": "VULMON",
"id": "CVE-2018-16417"
},
{
"db": "BID",
"id": "108374"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016143"
},
{
"db": "NVD",
"id": "CVE-2018-16417"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-052"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2019-06344"
},
{
"db": "VULMON",
"id": "CVE-2018-16417"
},
{
"db": "BID",
"id": "108374"
},
{
"db": "JVNDB",
"id": "JVNDB-2018-016143"
},
{
"db": "NVD",
"id": "CVE-2018-16417"
},
{
"db": "CNNVD",
"id": "CNNVD-201903-052"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-03-06T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-06344"
},
{
"date": "2019-10-30T00:00:00",
"db": "VULMON",
"id": "CVE-2018-16417"
},
{
"date": "2019-05-14T00:00:00",
"db": "BID",
"id": "108374"
},
{
"date": "2019-11-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-016143"
},
{
"date": "2019-10-30T17:15:11.877000",
"db": "NVD",
"id": "CVE-2018-16417"
},
{
"date": "2019-03-04T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201903-052"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2019-03-06T00:00:00",
"db": "CNVD",
"id": "CNVD-2019-06344"
},
{
"date": "2020-08-24T00:00:00",
"db": "VULMON",
"id": "CVE-2018-16417"
},
{
"date": "2019-05-14T00:00:00",
"db": "BID",
"id": "108374"
},
{
"date": "2019-11-12T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2018-016143"
},
{
"date": "2020-08-24T17:37:01.140000",
"db": "NVD",
"id": "CVE-2018-16417"
},
{
"date": "2020-08-25T00:00:00",
"db": "CNNVD",
"id": "CNNVD-201903-052"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201903-052"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Aruba Instant Injection vulnerability",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2018-016143"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "command injection",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-201903-052"
}
],
"trust": 0.6
}
}
ICSA-19-134-07
Vulnerability from csaf_cisa - Published: 2019-05-14 00:00 - Updated: 2019-05-14 00:00Notes
{
"document": {
"acknowledgments": [
{
"organization": "Siemens",
"summary": "reporting these vulnerabilities to NCCIC"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities could allow an attacker execute arbitrary commands within the underlying operating system, discover sensitive information, take administrative actions on the device, or expose session cookies for an administrative session.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Chemical, Energy, Food and Agriculture, Healthcare and Public Health, Transportation Systems, and Water and Wastewater Systems",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "NCCIC recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "NCCIC reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.NCCIC also provides a section for control systems security recommended practices on the ICS-CERT web page. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS-CERT website in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to NCCIC for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and \nsolutions, please contact the Siemens ProductCERT:\n\nhttps://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "other",
"text": "No known public exploits specifically target these vulnerabilities.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-19-134-07 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2019/icsa-19-134-07.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-19-134-07 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-19-134-07"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B"
},
{
"category": "external",
"summary": "SSA-496604: SSA-549547: Multiple Vulnerabilites in SCALANCE W1750D - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/SSA-549547.txt"
}
],
"title": "Siemens SCALANCE W1750D",
"tracking": {
"current_release_date": "2019-05-14T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-19-134-07",
"initial_release_date": "2019-05-14T00:00:00.000000Z",
"revision_history": [
{
"date": "2019-05-14T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-19-134-07 Siemens SCALANCE W1750D"
}
],
"status": "final",
"version": "1"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V8.4.0.1",
"product": {
"name": "SCALANCE W1750D: All versions \u003c V8.4.0.1",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "SCALANCE W1750D"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2018-7084",
"cwe": {
"id": "CWE-77",
"name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A command injection vulnerability is present that permits an unauthenticated user with access to the web interface of the affected device to execute arbitrary system commands within the underlying operating system. An attacker could use this ability to copy files, read configuration, write files, delete files, or reboot the device.",
"title": "Summary"
},
{
"category": "summary",
"text": "The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality, integrity and availability of the affected system.",
"title": "Summary"
},
{
"category": "summary",
"text": "At the time of advisory publication no public exploitation of this security vulnerability was known.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "https://support.industry.siemens.com/cs/us/en/view/109766816/",
"url": "https://support.industry.siemens.com/cs/us/en/view/109766816/"
},
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7084"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the web-based management interface to the internal or\nVPN network.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Do not browse other websites and do not click on external links while\nbeing authenticated to the administrative web interface.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Apply appropriate strategies for mitigation.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.4.0.1 - Download: https://support.industry.siemens.com/cs/us/en/view/109766816/ ",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/us/en/view/109766816/"
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2018-7083",
"cwe": {
"id": "CWE-200",
"name": "Exposure of Sensitive Information to an Unauthorized Actor"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability exists in the affected devices that allows an unauthenticated attacker to access core dumps of previously crashed processes through the web interface of the device.",
"title": "Summary"
},
{
"category": "summary",
"text": "The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality of the affected system.",
"title": "Summary"
},
{
"category": "summary",
"text": "At the time of advisory publication no public exploitation of this security vulnerability was known.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "https://support.industry.siemens.com/cs/us/en/view/109766816/",
"url": "https://support.industry.siemens.com/cs/us/en/view/109766816/"
},
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7083"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the web-based management interface to the internal or\nVPN network.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Do not browse other websites and do not click on external links while\nbeing authenticated to the administrative web interface.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Apply appropriate strategies for mitigation.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.4.0.1 - Download: https://support.industry.siemens.com/cs/us/en/view/109766816/ ",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/us/en/view/109766816/"
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2018-16417",
"cwe": {
"id": "CWE-200",
"name": "Exposure of Sensitive Information to an Unauthorized Actor"
},
"notes": [
{
"category": "summary",
"text": "A vulnerability is present which allows an unauthenticated user to retrieve recently cached configuration commands by sending a crafted URL to the web interface of an affected device.",
"title": "Summary"
},
{
"category": "summary",
"text": "The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality of the affected system.",
"title": "Summary"
},
{
"category": "summary",
"text": "At the time of advisory publication no public exploitation of this security vulnerability was known.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "https://support.industry.siemens.com/cs/us/en/view/109766816/",
"url": "https://support.industry.siemens.com/cs/us/en/view/109766816/"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the web-based management interface to the internal or\nVPN network.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Do not browse other websites and do not click on external links while\nbeing authenticated to the administrative web interface.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Apply appropriate strategies for mitigation.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.4.0.1 - Download: https://support.industry.siemens.com/cs/us/en/view/109766816/ ",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/us/en/view/109766816/"
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N/E:P/RL:O/RC:C",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2018-7082",
"cwe": {
"id": "CWE-77",
"name": "Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A command injection vulnerability is present in the affected devices that allows an authenticated administrative user to execute arbitrary commands on the underlying operating system.",
"title": "Summary"
},
{
"category": "summary",
"text": "The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no user interaction. An attacker could use the vulnerability to compromise confidentiality, integrity and availability of the affected system.",
"title": "Summary"
},
{
"category": "summary",
"text": "At the time of advisory publication no public exploitation of this security vulnerability was known.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "https://support.industry.siemens.com/cs/us/en/view/109766816/",
"url": "https://support.industry.siemens.com/cs/us/en/view/109766816/"
},
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7082"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the web-based management interface to the internal or\nVPN network.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Do not browse other websites and do not click on external links while\nbeing authenticated to the administrative web interface.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Apply appropriate strategies for mitigation.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.4.0.1 - Download: https://support.industry.siemens.com/cs/us/en/view/109766816/ ",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/us/en/view/109766816/"
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
},
{
"cve": "CVE-2018-7064",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected devices that allows an attacker to trick an administrator into clicking a link which could then take administrative actions on the device or expose a session cookie for an administrative session.",
"title": "Summary"
},
{
"category": "summary",
"text": "The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise confidentiality, integrity and availability of the affected system.",
"title": "Summary"
},
{
"category": "summary",
"text": "At the time of advisory publication no public exploitation of this security vulnerability was known.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001"
]
},
"references": [
{
"category": "external",
"summary": "https://support.industry.siemens.com/cs/us/en/view/109766816/",
"url": "https://support.industry.siemens.com/cs/us/en/view/109766816/"
},
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2018-7064"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:L/A:L"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Restrict access to the web-based management interface to the internal or\nVPN network.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Do not browse other websites and do not click on external links while\nbeing authenticated to the administrative web interface.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Apply appropriate strategies for mitigation.",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V8.4.0.1 - Download: https://support.industry.siemens.com/cs/us/en/view/109766816/ ",
"product_ids": [
"CSAFPID-0001"
],
"url": "https://support.industry.siemens.com/cs/us/en/view/109766816/"
},
{
"category": "mitigation",
"details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity",
"product_ids": [
"CSAFPID-0001"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:L/A:L/E:P/RL:O/RC:C",
"version": "3.0"
},
"products": [
"CSAFPID-0001"
]
}
]
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.