cve-2018-18093
Vulnerability from cvelistv5
Published
2018-12-13 23:00
Modified
2024-08-05 11:01
Severity ?
Summary
Improper file permissions in the installer for Intel VTune Amplifier 2018 Update 3 and before may allow unprivileged user to potentially gain privileged access via local access.
Impacted products
Vendor Product Version
Intel Corporation Intel VTune Amplifier Version: Intel VTune Amplifier 2018 Update 3 and before
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:01:14.845Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00194.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Intel VTune Amplifier",
          "vendor": "Intel Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Intel VTune Amplifier 2018 Update 3 and before"
            }
          ]
        }
      ],
      "datePublic": "2018-12-13T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Improper file permissions in the installer for Intel VTune Amplifier 2018 Update 3 and before may allow unprivileged user to potentially gain privileged access via local access."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Escalation of Privilege",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-12-13T22:57:01",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00194.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@intel.com",
          "ID": "CVE-2018-18093",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Intel VTune Amplifier",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Intel VTune Amplifier 2018 Update 3 and before"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Intel Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Improper file permissions in the installer for Intel VTune Amplifier 2018 Update 3 and before may allow unprivileged user to potentially gain privileged access via local access."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Escalation of Privilege"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00194.html",
              "refsource": "CONFIRM",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00194.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2018-18093",
    "datePublished": "2018-12-13T23:00:00",
    "dateReserved": "2018-10-09T00:00:00",
    "dateUpdated": "2024-08-05T11:01:14.845Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:intel:vtune_amplifier:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"2018\", \"matchCriteriaId\": \"FD2326FA-4DC7-42A2-8109-187692C6457D\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:intel:vtune_amplifier:2018:update1:*:*:*:*:*:*\", \"matchCriteriaId\": \"6538D07B-7091-4BCC-B04A-64000E7BF839\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:intel:vtune_amplifier:2018:update2:*:*:*:*:*:*\", \"matchCriteriaId\": \"FB6FC5C8-FBB7-4337-B06B-A38BE5DC1C94\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:intel:vtune_amplifier:2018:update3:*:*:*:*:*:*\", \"matchCriteriaId\": \"64C77B95-6966-4E49-A24C-1BE3CFD0EBAA\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Improper file permissions in the installer for Intel VTune Amplifier 2018 Update 3 and before may allow unprivileged user to potentially gain privileged access via local access.\"}, {\"lang\": \"es\", \"value\": \"Permisos de archivo incorrectos en el instalador de Intel VTune Amplifier 2018 Update 3 y anteriores podr\\u00eda permitir que usuarios sin privilegios obtenga acceso privilegiado mediante un acceso local.\"}]",
      "id": "CVE-2018-18093",
      "lastModified": "2024-11-21T03:55:28.140",
      "metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:P/I:P/A:P\", \"baseScore\": 4.6, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 3.9, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2018-12-14T00:29:01.237",
      "references": "[{\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00194.html\", \"source\": \"secure@intel.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00194.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "secure@intel.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-732\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2018-18093\",\"sourceIdentifier\":\"secure@intel.com\",\"published\":\"2018-12-14T00:29:01.237\",\"lastModified\":\"2024-11-21T03:55:28.140\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper file permissions in the installer for Intel VTune Amplifier 2018 Update 3 and before may allow unprivileged user to potentially gain privileged access via local access.\"},{\"lang\":\"es\",\"value\":\"Permisos de archivo incorrectos en el instalador de Intel VTune Amplifier 2018 Update 3 y anteriores podr\u00eda permitir que usuarios sin privilegios obtenga acceso privilegiado mediante un acceso local.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":4.6,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.9,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-732\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:intel:vtune_amplifier:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2018\",\"matchCriteriaId\":\"FD2326FA-4DC7-42A2-8109-187692C6457D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:intel:vtune_amplifier:2018:update1:*:*:*:*:*:*\",\"matchCriteriaId\":\"6538D07B-7091-4BCC-B04A-64000E7BF839\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:intel:vtune_amplifier:2018:update2:*:*:*:*:*:*\",\"matchCriteriaId\":\"FB6FC5C8-FBB7-4337-B06B-A38BE5DC1C94\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:intel:vtune_amplifier:2018:update3:*:*:*:*:*:*\",\"matchCriteriaId\":\"64C77B95-6966-4E49-A24C-1BE3CFD0EBAA\"}]}]}],\"references\":[{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00194.html\",\"source\":\"secure@intel.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00194.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.