CVE-2018-18602 (GCVE-0-2018-18602)

Vulnerability from cvelistv5 – Published: 2018-12-31 16:00 – Updated: 2025-05-06 16:12
VLAI?
Summary
The Cloud API on Guardzilla smart cameras allows user enumeration, with resultant arbitrary camera access and monitoring.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:15:59.845Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://labs.bitdefender.com/2018/12/iot-report-major-flaws-in-guardzilla-cameras-allow-remote-hijack-of-the-security-device/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2018-18602",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-05-06T16:08:23.829839Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-330",
                "description": "CWE-330 Use of Insufficiently Random Values",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-05-06T16:12:40.867Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2018-12-28T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "The Cloud API on Guardzilla smart cameras allows user enumeration, with resultant arbitrary camera access and monitoring."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-12-31T15:57:01.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://labs.bitdefender.com/2018/12/iot-report-major-flaws-in-guardzilla-cameras-allow-remote-hijack-of-the-security-device/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2018-18602",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Cloud API on Guardzilla smart cameras allows user enumeration, with resultant arbitrary camera access and monitoring."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://labs.bitdefender.com/2018/12/iot-report-major-flaws-in-guardzilla-cameras-allow-remote-hijack-of-the-security-device/",
              "refsource": "MISC",
              "url": "https://labs.bitdefender.com/2018/12/iot-report-major-flaws-in-guardzilla-cameras-allow-remote-hijack-of-the-security-device/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2018-18602",
    "datePublished": "2018-12-31T16:00:00.000Z",
    "dateReserved": "2018-10-23T00:00:00.000Z",
    "dateUpdated": "2025-05-06T16:12:40.867Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:guardzilla:360_outdoor_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7B0BD241-ACDB-45AE-99CB-99CAD73654C0\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:guardzilla:360_outdoor:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7294712E-3942-4AED-9C2B-FB9BC6587D87\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:guardzilla:180_outdoor_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"BA3C1F5F-8F4D-4A60-BDDD-C6ED5A6BB00D\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:guardzilla:180_outdoor:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"254CD729-E789-4AC1-A116-561584D4A492\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:guardzilla:360_indoor_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"ABA95D4D-4C26-4EBE-8002-1CFB56A1B052\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:guardzilla:360_indoor:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4F2C8B45-5D55-4809-AB60-A93B0812DED2\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:guardzilla:180_indoor_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2A9D67F8-C27F-47DB-8039-868E07192FFA\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:guardzilla:180_indoor:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"00337D5B-4651-4E54-85BD-46A93F7C124C\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:guardzilla:outdoor_hd_camera_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"83115E4E-E48E-4F79-9163-1E29DC72BD53\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:guardzilla:outdoor_hd_camera:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"091FD9B2-36CB-4F06-AD69-087BB8AE10FB\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:guardzilla:indoor_hd_camera_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7BA43B82-77C5-4119-BE97-1555FB963679\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:guardzilla:indoor_hd_camera:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"59FD061E-42EC-40A2-A775-425262F6634D\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"The Cloud API on Guardzilla smart cameras allows user enumeration, with resultant arbitrary camera access and monitoring.\"}, {\"lang\": \"es\", \"value\": \"La API Cloud en las c\\u00e1maras inteligentes de Guardzilla permiten la enumeraci\\u00f3n de usuarios que, en consecuencia, proporciona acceso a c\\u00e1maras y monitorizaci\\u00f3n de manera arbitraria.\"}]",
      "id": "CVE-2018-18602",
      "lastModified": "2024-11-21T03:56:13.793",
      "metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:N/A:N\", \"baseScore\": 5.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2018-12-31T16:29:00.360",
      "references": "[{\"url\": \"https://labs.bitdefender.com/2018/12/iot-report-major-flaws-in-guardzilla-cameras-allow-remote-hijack-of-the-security-device/\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://labs.bitdefender.com/2018/12/iot-report-major-flaws-in-guardzilla-cameras-allow-remote-hijack-of-the-security-device/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}]",
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-330\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2018-18602\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2018-12-31T16:29:00.360\",\"lastModified\":\"2025-05-06T17:15:48.733\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The Cloud API on Guardzilla smart cameras allows user enumeration, with resultant arbitrary camera access and monitoring.\"},{\"lang\":\"es\",\"value\":\"La API Cloud en las c\u00e1maras inteligentes de Guardzilla permiten la enumeraci\u00f3n de usuarios que, en consecuencia, proporciona acceso a c\u00e1maras y monitorizaci\u00f3n de manera arbitraria.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-330\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-330\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:guardzilla:360_outdoor_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7B0BD241-ACDB-45AE-99CB-99CAD73654C0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:guardzilla:360_outdoor:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7294712E-3942-4AED-9C2B-FB9BC6587D87\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:guardzilla:180_outdoor_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BA3C1F5F-8F4D-4A60-BDDD-C6ED5A6BB00D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:guardzilla:180_outdoor:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"254CD729-E789-4AC1-A116-561584D4A492\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:guardzilla:360_indoor_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"ABA95D4D-4C26-4EBE-8002-1CFB56A1B052\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:guardzilla:360_indoor:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4F2C8B45-5D55-4809-AB60-A93B0812DED2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:guardzilla:180_indoor_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2A9D67F8-C27F-47DB-8039-868E07192FFA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:guardzilla:180_indoor:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"00337D5B-4651-4E54-85BD-46A93F7C124C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:guardzilla:outdoor_hd_camera_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"83115E4E-E48E-4F79-9163-1E29DC72BD53\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:guardzilla:outdoor_hd_camera:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"091FD9B2-36CB-4F06-AD69-087BB8AE10FB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:guardzilla:indoor_hd_camera_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7BA43B82-77C5-4119-BE97-1555FB963679\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:guardzilla:indoor_hd_camera:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"59FD061E-42EC-40A2-A775-425262F6634D\"}]}]}],\"references\":[{\"url\":\"https://labs.bitdefender.com/2018/12/iot-report-major-flaws-in-guardzilla-cameras-allow-remote-hijack-of-the-security-device/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://labs.bitdefender.com/2018/12/iot-report-major-flaws-in-guardzilla-cameras-allow-remote-hijack-of-the-security-device/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://labs.bitdefender.com/2018/12/iot-report-major-flaws-in-guardzilla-cameras-allow-remote-hijack-of-the-security-device/\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-05T11:15:59.845Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 9.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2018-18602\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-05-06T16:08:23.829839Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-330\", \"description\": \"CWE-330 Use of Insufficiently Random Values\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-05-06T16:08:35.260Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"datePublic\": \"2018-12-28T00:00:00.000Z\", \"references\": [{\"url\": \"https://labs.bitdefender.com/2018/12/iot-report-major-flaws-in-guardzilla-cameras-allow-remote-hijack-of-the-security-device/\", \"tags\": [\"x_refsource_MISC\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"The Cloud API on Guardzilla smart cameras allows user enumeration, with resultant arbitrary camera access and monitoring.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"n/a\"}]}], \"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2018-12-31T15:57:01.000Z\"}, \"x_legacyV4Record\": {\"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"n/a\"}]}, \"product_name\": \"n/a\"}]}, \"vendor_name\": \"n/a\"}]}}, \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://labs.bitdefender.com/2018/12/iot-report-major-flaws-in-guardzilla-cameras-allow-remote-hijack-of-the-security-device/\", \"name\": \"https://labs.bitdefender.com/2018/12/iot-report-major-flaws-in-guardzilla-cameras-allow-remote-hijack-of-the-security-device/\", \"refsource\": \"MISC\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"The Cloud API on Guardzilla smart cameras allows user enumeration, with resultant arbitrary camera access and monitoring.\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"n/a\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2018-18602\", \"STATE\": \"PUBLIC\", \"ASSIGNER\": \"cve@mitre.org\"}}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2018-18602\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-05-06T16:12:40.867Z\", \"dateReserved\": \"2018-10-23T00:00:00.000Z\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"datePublished\": \"2018-12-31T16:00:00.000Z\", \"assignerShortName\": \"mitre\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…