CVE-2018-21181 (GCVE-0-2018-21181)
Vulnerability from cvelistv5 – Published: 2020-04-28 12:47 – Updated: 2024-08-05 12:26
VLAI?
Summary
Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.28, EX2700 before 1.0.1.32, EX6200v2 before 1.0.1.56, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.52, WN3100RPv2 before 1.0.0.42, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.
Severity ?
6.8 (Medium)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T12:26:39.308Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://kb.netgear.com/000055177/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2618"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.28, EX2700 before 1.0.1.32, EX6200v2 before 1.0.1.56, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.52, WN3100RPv2 before 1.0.0.42, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-04-28T12:47:24",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://kb.netgear.com/000055177/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2618"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2018-21181",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.28, EX2700 before 1.0.1.32, EX6200v2 before 1.0.1.56, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.52, WN3100RPv2 before 1.0.0.42, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"availabilityImpact": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:U/UI:N",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000055177/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2618",
"refsource": "CONFIRM",
"url": "https://kb.netgear.com/000055177/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2618"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2018-21181",
"datePublished": "2020-04-28T12:47:24",
"dateReserved": "2020-04-20T00:00:00",
"dateUpdated": "2024-08-05T12:26:39.308Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.1.28\", \"matchCriteriaId\": \"EB2E25FA-14F1-44ED-99D3-B5ED7D898D59\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"DA2D4987-3726-4A72-8D32-592F59FAC46D\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.1.32\", \"matchCriteriaId\": \"7D8426F7-28E5-4903-8936-B6F8D5733142\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5341B659-DE7D-43F1-954D-82049CBE18AD\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.1.56\", \"matchCriteriaId\": \"08D74CD0-EEE6-4A1D-809C-C0ED7E69489E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:ex6200:v2:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B4F62287-CB55-4FB1-AA39-62018654BA39\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.3.24\", \"matchCriteriaId\": \"C38F66ED-C53D-40F4-9F1E-96254BCD8A0C\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.2.40\", \"matchCriteriaId\": \"A2E62164-2324-4AF2-B300-8005DAD433B6\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"17CF7445-6950-45FE-9D1A-E23F63316329\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.3.6\", \"matchCriteriaId\": \"E460D519-DDF3-4E59-9E41-050DC3723FD7\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.1.20\", \"matchCriteriaId\": \"BC14D1E5-1302-4E4E-9119-E64342B0AE21\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6FB1BE0D-E3CF-4C16-8C11-706B238E9934\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.2.52\", \"matchCriteriaId\": \"6FAAE779-B8EA-42A3-BF22-FF17D779300E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.0.42\", \"matchCriteriaId\": \"B562B414-1A33-4E81-83FF-D8750D977DDC\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4D8680F5-0C06-4CFC-8BA0-CF85D0438419\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.2.92\", \"matchCriteriaId\": \"90A3C8B6-51A9-49BC-8C82-01269519B652\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"257A5E68-8EDC-44F5-A85C-83A91C93CCE5\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.2.94\", \"matchCriteriaId\": \"ACAD8DCD-C187-4F15-9828-F302295199BA\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1413C591-D066-4FA2-BEB1-6C60F8645F28\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.0.50\", \"matchCriteriaId\": \"1425F7B0-0990-43F4-9621-8DAE8508FEED\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4428B145-B86D-4709-BBA9-64BDE7D35A25\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.0.50\", \"matchCriteriaId\": \"81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C31D6808-4103-4543-B7AB-84A79CD12006\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.0.62\", \"matchCriteriaId\": \"27B33A47-E305-43CC-9AC2-C35DE8E51F02\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"317F25FF-B3A2-4C68-888F-D2627C564867\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.28, EX2700 before 1.0.1.32, EX6200v2 before 1.0.1.56, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.52, WN3100RPv2 before 1.0.0.42, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.\"}, {\"lang\": \"es\", \"value\": \"Determinados dispositivos NETGEAR est\\u00e1n afectados por un desbordamiento del b\\u00fafer en la regi\\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.28, EX2700 versiones anteriores a 1.0.1.32, EX6200v2 versiones anteriores a 1.0.1.56, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1.0.3.6, WN2000RPTv3 versiones anteriores a 1.0.1. 20, WN3000RPv3 versiones anteriores a 1.0.2.52, WN3100RPv2 versiones anteriores a 1.0.0.42, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62.\"}]",
"id": "CVE-2018-21181",
"lastModified": "2024-11-21T04:03:06.550",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.2, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.2, \"impactScore\": 5.9}], \"cvssMetricV30\": [{\"source\": \"cve@mitre.org\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 6.8, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"ADJACENT_NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 0.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:S/C:P/I:P/A:P\", \"baseScore\": 6.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.0, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2020-04-28T13:15:12.480",
"references": "[{\"url\": \"https://kb.netgear.com/000055177/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2618\", \"source\": \"cve@mitre.org\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://kb.netgear.com/000055177/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2618\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-787\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2018-21181\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2020-04-28T13:15:12.480\",\"lastModified\":\"2024-11-21T04:03:06.550\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Certain NETGEAR devices are affected by a stack-based buffer overflow by an authenticated user. This affects D7800 before 1.0.1.28, EX2700 before 1.0.1.32, EX6200v2 before 1.0.1.56, R7500v2 before 1.0.3.24, R7800 before 1.0.2.40, R9000 before 1.0.3.6, WN2000RPTv3 before 1.0.1.20, WN3000RPv3 before 1.0.2.52, WN3100RPv2 before 1.0.0.42, WNDR3700v4 before 1.0.2.92, WNDR4300 before 1.0.2.94, WNDR4300v2 before 1.0.0.50, WNDR4500v3 before 1.0.0.50, and WNR2000v5 before 1.0.0.62.\"},{\"lang\":\"es\",\"value\":\"Determinados dispositivos NETGEAR est\u00e1n afectados por un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria por parte de un usuario autenticado. Esto afecta a D7800 versiones anteriores a 1.0.1.28, EX2700 versiones anteriores a 1.0.1.32, EX6200v2 versiones anteriores a 1.0.1.56, R7500v2 versiones anteriores a 1.0.3.24, R7800 versiones anteriores a 1.0.2.40, R9000 versiones anteriores a 1.0.3.6, WN2000RPTv3 versiones anteriores a 1.0.1. 20, WN3000RPv3 versiones anteriores a 1.0.2.52, WN3100RPv2 versiones anteriores a 1.0.0.42, WNDR3700v4 versiones anteriores a 1.0.2.92, WNDR4300 versiones anteriores a 1.0.2.94, WNDR4300v2 versiones anteriores a 1.0.0.50, WNDR4500v3 versiones anteriores a 1.0.0.50, y WNR2000v5 versiones anteriores a 1.0.0.62.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}],\"cvssMetricV30\":[{\"source\":\"cve@mitre.org\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:d7800_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.1.28\",\"matchCriteriaId\":\"EB2E25FA-14F1-44ED-99D3-B5ED7D898D59\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:d7800:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DA2D4987-3726-4A72-8D32-592F59FAC46D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex2700_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.1.32\",\"matchCriteriaId\":\"7D8426F7-28E5-4903-8936-B6F8D5733142\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex2700:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5341B659-DE7D-43F1-954D-82049CBE18AD\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:ex6200_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.1.56\",\"matchCriteriaId\":\"08D74CD0-EEE6-4A1D-809C-C0ED7E69489E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:ex6200:v2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B4F62287-CB55-4FB1-AA39-62018654BA39\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:r7500_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.3.24\",\"matchCriteriaId\":\"C38F66ED-C53D-40F4-9F1E-96254BCD8A0C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:r7500:v2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2E0DFBF4-E393-44AE-AEF9-1B2059EE5AE8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:r7800_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.2.40\",\"matchCriteriaId\":\"A2E62164-2324-4AF2-B300-8005DAD433B6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:r7800:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"17CF7445-6950-45FE-9D1A-E23F63316329\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:r9000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.3.6\",\"matchCriteriaId\":\"E460D519-DDF3-4E59-9E41-050DC3723FD7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:r9000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D74F1BFC-562E-4E7D-BBAB-2F8B593B5A57\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:wn2000rpt_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.1.20\",\"matchCriteriaId\":\"BC14D1E5-1302-4E4E-9119-E64342B0AE21\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:wn2000rpt:v3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6FB1BE0D-E3CF-4C16-8C11-706B238E9934\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:wn3000rp_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.2.52\",\"matchCriteriaId\":\"6FAAE779-B8EA-42A3-BF22-FF17D779300E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:wn3000rp:v3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AB71AC74-2D1B-4F1E-A70F-6590A00AAD9E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:wn3100rp_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.0.42\",\"matchCriteriaId\":\"B562B414-1A33-4E81-83FF-D8750D977DDC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:wn3100rp:v2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4D8680F5-0C06-4CFC-8BA0-CF85D0438419\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:wndr3700_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.2.92\",\"matchCriteriaId\":\"90A3C8B6-51A9-49BC-8C82-01269519B652\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:wndr3700:v4:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"257A5E68-8EDC-44F5-A85C-83A91C93CCE5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.2.94\",\"matchCriteriaId\":\"ACAD8DCD-C187-4F15-9828-F302295199BA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:wndr4300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1413C591-D066-4FA2-BEB1-6C60F8645F28\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:wndr4300_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.0.50\",\"matchCriteriaId\":\"1425F7B0-0990-43F4-9621-8DAE8508FEED\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:wndr4300:v2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4428B145-B86D-4709-BBA9-64BDE7D35A25\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:wndr4500_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.0.50\",\"matchCriteriaId\":\"81A6B7D4-1CBB-4D9E-8EB2-E5E82AFA59FA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:wndr4500:v3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C31D6808-4103-4543-B7AB-84A79CD12006\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:wnr2000_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.0.62\",\"matchCriteriaId\":\"27B33A47-E305-43CC-9AC2-C35DE8E51F02\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:wnr2000:v5:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"317F25FF-B3A2-4C68-888F-D2627C564867\"}]}]}],\"references\":[{\"url\":\"https://kb.netgear.com/000055177/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2618\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://kb.netgear.com/000055177/Security-Advisory-for-Post-Authentication-Stack-Overflow-on-Some-Routers-Gateways-and-Extenders-PSV-2017-2618\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…