CVE-2018-4839 (GCVE-0-2018-4839)

Vulnerability from cvelistv5 – Published: 2018-03-08 17:00 – Updated: 2024-08-05 05:18
VLAI?
Summary
A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions), Other SIPROTEC 4 relays (All versions), Other SIPROTEC Compact relays (All versions), SIPROTEC 4 7SD80 (All versions < V4.70), SIPROTEC 4 7SJ61 (All versions < V4.96), SIPROTEC 4 7SJ62 (All versions < V4.96), SIPROTEC 4 7SJ64 (All versions < V4.96), SIPROTEC 4 7SJ66 (All versions < V4.30), SIPROTEC Compact 7SJ80 (All versions < V4.77), SIPROTEC Compact 7SK80 (All versions < V4.77). An attacker with local access to the engineering system or in a privileged network position and able to obtain certain network traffic could possibly reconstruct access authorization passwords.
Severity ?
No CVSS data available.
CWE
  • CWE-326 - Inadequate Encryption Strength
Assigner
References
Impacted products
Vendor Product Version
Siemens DIGSI 4 Affected: All versions < V4.92
Create a notification for this product.
    Siemens EN100 Ethernet module DNP3 variant Affected: All versions < V1.05.00
Create a notification for this product.
    Siemens EN100 Ethernet module IEC 104 variant Affected: All versions
Create a notification for this product.
    Siemens EN100 Ethernet module IEC 61850 variant Affected: All versions < V4.30
Create a notification for this product.
    Siemens EN100 Ethernet module Modbus TCP variant Affected: All versions
Create a notification for this product.
    Siemens EN100 Ethernet module PROFINET IO variant Affected: All versions
Create a notification for this product.
    Siemens Other SIPROTEC 4 relays Affected: All versions
Create a notification for this product.
    Siemens Other SIPROTEC Compact relays Affected: All versions
Create a notification for this product.
    Siemens SIPROTEC 4 7SD80 Affected: All versions < V4.70
Create a notification for this product.
    Siemens SIPROTEC 4 7SJ61 Affected: All versions < V4.96
Create a notification for this product.
    Siemens SIPROTEC 4 7SJ62 Affected: All versions < V4.96
Create a notification for this product.
    Siemens SIPROTEC 4 7SJ64 Affected: All versions < V4.96
Create a notification for this product.
    Siemens SIPROTEC 4 7SJ66 Affected: All versions < V4.30
Create a notification for this product.
    Siemens SIPROTEC Compact 7SJ80 Affected: All versions < V4.77
Create a notification for this product.
    Siemens SIPROTEC Compact 7SK80 Affected: All versions < V4.77
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T05:18:26.659Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DIGSI 4",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.92"
            }
          ]
        },
        {
          "product": "EN100 Ethernet module DNP3 variant",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.05.00"
            }
          ]
        },
        {
          "product": "EN100 Ethernet module IEC 104 variant",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "EN100 Ethernet module IEC 61850 variant",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.30"
            }
          ]
        },
        {
          "product": "EN100 Ethernet module Modbus TCP variant",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "EN100 Ethernet module PROFINET IO variant",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Other SIPROTEC 4 relays",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "Other SIPROTEC Compact relays",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "product": "SIPROTEC 4 7SD80",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.70"
            }
          ]
        },
        {
          "product": "SIPROTEC 4 7SJ61",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.96"
            }
          ]
        },
        {
          "product": "SIPROTEC 4 7SJ62",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.96"
            }
          ]
        },
        {
          "product": "SIPROTEC 4 7SJ64",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.96"
            }
          ]
        },
        {
          "product": "SIPROTEC 4 7SJ66",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.30"
            }
          ]
        },
        {
          "product": "SIPROTEC Compact 7SJ80",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.77"
            }
          ]
        },
        {
          "product": "SIPROTEC Compact 7SK80",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.77"
            }
          ]
        }
      ],
      "datePublic": "2018-03-08T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in DIGSI 4 (All versions \u003c V4.92), EN100 Ethernet module DNP3 variant (All versions \u003c V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions \u003c V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions), Other SIPROTEC 4 relays (All versions), Other SIPROTEC Compact relays (All versions), SIPROTEC 4 7SD80 (All versions \u003c V4.70), SIPROTEC 4 7SJ61 (All versions \u003c V4.96), SIPROTEC 4 7SJ62 (All versions \u003c V4.96), SIPROTEC 4 7SJ64 (All versions \u003c V4.96), SIPROTEC 4 7SJ66 (All versions \u003c V4.30), SIPROTEC Compact 7SJ80 (All versions \u003c V4.77), SIPROTEC Compact 7SK80 (All versions \u003c V4.77). An attacker with local access to the engineering system or in a privileged network position and able to obtain certain network traffic could possibly reconstruct access authorization passwords."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-326",
              "description": "CWE-326: Inadequate Encryption Strength",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-13T11:02:46",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2018-4839",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "DIGSI 4",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.92"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "EN100 Ethernet module DNP3 variant",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V1.05.00"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "EN100 Ethernet module IEC 104 variant",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "EN100 Ethernet module IEC 61850 variant",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.30"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "EN100 Ethernet module Modbus TCP variant",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "EN100 Ethernet module PROFINET IO variant",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Other SIPROTEC 4 relays",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Other SIPROTEC Compact relays",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPROTEC 4 7SD80",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.70"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPROTEC 4 7SJ61",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.96"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPROTEC 4 7SJ62",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.96"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPROTEC 4 7SJ64",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.96"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPROTEC 4 7SJ66",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.30"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPROTEC Compact 7SJ80",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.77"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPROTEC Compact 7SK80",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.77"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in DIGSI 4 (All versions \u003c V4.92), EN100 Ethernet module DNP3 variant (All versions \u003c V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions \u003c V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions), Other SIPROTEC 4 relays (All versions), Other SIPROTEC Compact relays (All versions), SIPROTEC 4 7SD80 (All versions \u003c V4.70), SIPROTEC 4 7SJ61 (All versions \u003c V4.96), SIPROTEC 4 7SJ62 (All versions \u003c V4.96), SIPROTEC 4 7SJ64 (All versions \u003c V4.96), SIPROTEC 4 7SJ66 (All versions \u003c V4.30), SIPROTEC Compact 7SJ80 (All versions \u003c V4.77), SIPROTEC Compact 7SK80 (All versions \u003c V4.77). An attacker with local access to the engineering system or in a privileged network position and able to obtain certain network traffic could possibly reconstruct access authorization passwords."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-326: Inadequate Encryption Strength"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdf",
              "refsource": "CONFIRM",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2018-4839",
    "datePublished": "2018-03-08T17:00:00",
    "dateReserved": "2018-01-02T00:00:00",
    "dateUpdated": "2024-08-05T05:18:26.659Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:siprotec_compact_7sj80_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.77\", \"matchCriteriaId\": \"CA01070B-B71D-4432-A39F-91F9AF699985\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:siprotec_compact_7sj80:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"474DE009-D90F-47D1-912B-765EF1C84AF5\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:siprotec_compact_7sk80_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.77\", \"matchCriteriaId\": \"B9053816-0F6F-4647-AAD4-E665711823EB\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:siprotec_compact_7sk80:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"EE4B76D9-5208-4766-8E3F-D8911BDC3A78\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:siprotec_4_7sj66_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.30\", \"matchCriteriaId\": \"D44664B0-13FF-449F-A329-2F267C0A29C0\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:siprotec_4_7sj66:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"53D3E04F-7181-488A-AAEF-E846C3DC9BCB\"}]}]}, {\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:digsi_4:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.92\", \"matchCriteriaId\": \"69174713-D30C-41BE-8192-E3A766E68E9F\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:en100_ethernet_module_iec_104_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"300FAA93-3BBB-4848-AFA5-97DE57053E5E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:en100_ethernet_module_iec_104:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"75FDB347-4ED5-4A36-A9CA-B2A461A92572\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:en100_ethernet_module_dnp3_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"15E8060A-2897-4E2E-9441-5687D923C642\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:en100_ethernet_module_dnp3:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6E733162-1D6E-4CF7-9CB2-007C8CA8B6B4\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:en100_ethernet_module_modbus_tcp_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"71DCD4E3-9BA4-44CE-BFCC-6659258FCE31\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:en100_ethernet_module_modbus_tcp:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"48118739-31B9-4600-8856-D7E9870479E7\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:en100_ethernet_module_profinet_io_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0C2FA062-EBFE-457F-988E-60A9317212A4\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:en100_ethernet_module_profinet_io:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"11199473-60BF-42AB-B6F0-BEF9663C67B7\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:en100_ethernet_module_iec_61850_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"4.30\", \"matchCriteriaId\": \"42ABCFB1-0D86-47DB-8257-370B70E1C969\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:en100_ethernet_module_iec_61850:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3C5EC8F7-6CD2-461B-9D06-2D9F4D083A98\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in DIGSI 4 (All versions \u003c V4.92), EN100 Ethernet module DNP3 variant (All versions \u003c V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions \u003c V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions), Other SIPROTEC 4 relays (All versions), Other SIPROTEC Compact relays (All versions), SIPROTEC 4 7SD80 (All versions \u003c V4.70), SIPROTEC 4 7SJ61 (All versions \u003c V4.96), SIPROTEC 4 7SJ62 (All versions \u003c V4.96), SIPROTEC 4 7SJ64 (All versions \u003c V4.96), SIPROTEC 4 7SJ66 (All versions \u003c V4.30), SIPROTEC Compact 7SJ80 (All versions \u003c V4.77), SIPROTEC Compact 7SK80 (All versions \u003c V4.77). An attacker with local access to the engineering system or in a privileged network position and able to obtain certain network traffic could possibly reconstruct access authorization passwords.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en Siemens DIGSI 4 (Todas las versiones anteriores a V4.92), EN100 Ethernet module DNP3 variant (Todas las versiones anteriores a V1.05.00), EN100 Ethernet module IEC 104 variant (Todas las versiones), EN100 Ethernet module IEC 61850 variant (Todas las versiones anteriores a V4.30), EN100 Ethernet module Modbus TCP variant (Todas las versiones), EN100 Ethernet module PROFINET IO variant (Todas las versiones), Other SIPROTEC 4 relays (Todas las versiones), Other SIPROTEC Compact relays (Todas las versiones), SIPROTEC 4 7SD80 (Todas las versiones anteriores a V4.70), SIPROTEC 4 7SJ61 (Todas las versiones anteriores a V4.96), SIPROTEC 4 7SJ62 (Todas las versiones anteriores a V4.96), SIPROTEC 4 7SJ64 (Todas las versiones anteriores a V4.96), SIPROTEC 4 7SJ66 (Todas las versiones anteriores a V4.30), SIPROTEC Compact 7SJ80 (Todas las versiones anteriores a V4.77), SIPROTEC Compact 7SK80 (Todas las versiones anteriores a V4.77). Un atacante con acceso local al sistema de ingenier\\u00eda o en una posici\\u00f3n de red privilegiada y capaz de obtener cierto tr\\u00e1fico de red podr\\u00eda reconstruir contrase\\u00f1as de autorizaci\\u00f3n de acceso\"}]",
      "id": "CVE-2018-4839",
      "lastModified": "2024-11-21T04:07:33.527",
      "metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 5.3, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 1.6, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:S/C:P/I:N/A:N\", \"baseScore\": 3.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"LOW\", \"exploitabilityScore\": 6.8, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2018-03-08T17:29:00.257",
      "references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-18-067-01\", \"source\": \"nvd@nist.gov\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"productcert@siemens.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-326\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-noinfo\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2018-4839\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2018-03-08T17:29:00.257\",\"lastModified\":\"2024-11-21T04:07:33.527\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in DIGSI 4 (All versions \u003c V4.92), EN100 Ethernet module DNP3 variant (All versions \u003c V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions \u003c V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions), Other SIPROTEC 4 relays (All versions), Other SIPROTEC Compact relays (All versions), SIPROTEC 4 7SD80 (All versions \u003c V4.70), SIPROTEC 4 7SJ61 (All versions \u003c V4.96), SIPROTEC 4 7SJ62 (All versions \u003c V4.96), SIPROTEC 4 7SJ64 (All versions \u003c V4.96), SIPROTEC 4 7SJ66 (All versions \u003c V4.30), SIPROTEC Compact 7SJ80 (All versions \u003c V4.77), SIPROTEC Compact 7SK80 (All versions \u003c V4.77). An attacker with local access to the engineering system or in a privileged network position and able to obtain certain network traffic could possibly reconstruct access authorization passwords.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Siemens DIGSI 4 (Todas las versiones anteriores a V4.92), EN100 Ethernet module DNP3 variant (Todas las versiones anteriores a V1.05.00), EN100 Ethernet module IEC 104 variant (Todas las versiones), EN100 Ethernet module IEC 61850 variant (Todas las versiones anteriores a V4.30), EN100 Ethernet module Modbus TCP variant (Todas las versiones), EN100 Ethernet module PROFINET IO variant (Todas las versiones), Other SIPROTEC 4 relays (Todas las versiones), Other SIPROTEC Compact relays (Todas las versiones), SIPROTEC 4 7SD80 (Todas las versiones anteriores a V4.70), SIPROTEC 4 7SJ61 (Todas las versiones anteriores a V4.96), SIPROTEC 4 7SJ62 (Todas las versiones anteriores a V4.96), SIPROTEC 4 7SJ64 (Todas las versiones anteriores a V4.96), SIPROTEC 4 7SJ66 (Todas las versiones anteriores a V4.30), SIPROTEC Compact 7SJ80 (Todas las versiones anteriores a V4.77), SIPROTEC Compact 7SK80 (Todas las versiones anteriores a V4.77). Un atacante con acceso local al sistema de ingenier\u00eda o en una posici\u00f3n de red privilegiada y capaz de obtener cierto tr\u00e1fico de red podr\u00eda reconstruir contrase\u00f1as de autorizaci\u00f3n de acceso\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.6,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:S/C:P/I:N/A:N\",\"baseScore\":3.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":6.8,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-326\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:siprotec_compact_7sj80_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.77\",\"matchCriteriaId\":\"CA01070B-B71D-4432-A39F-91F9AF699985\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:siprotec_compact_7sj80:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"474DE009-D90F-47D1-912B-765EF1C84AF5\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:siprotec_compact_7sk80_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.77\",\"matchCriteriaId\":\"B9053816-0F6F-4647-AAD4-E665711823EB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:siprotec_compact_7sk80:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EE4B76D9-5208-4766-8E3F-D8911BDC3A78\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:siprotec_4_7sj66_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.30\",\"matchCriteriaId\":\"D44664B0-13FF-449F-A329-2F267C0A29C0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:siprotec_4_7sj66:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"53D3E04F-7181-488A-AAEF-E846C3DC9BCB\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:digsi_4:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.92\",\"matchCriteriaId\":\"69174713-D30C-41BE-8192-E3A766E68E9F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:en100_ethernet_module_iec_104_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"300FAA93-3BBB-4848-AFA5-97DE57053E5E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:en100_ethernet_module_iec_104:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"75FDB347-4ED5-4A36-A9CA-B2A461A92572\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:en100_ethernet_module_dnp3_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"15E8060A-2897-4E2E-9441-5687D923C642\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:en100_ethernet_module_dnp3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6E733162-1D6E-4CF7-9CB2-007C8CA8B6B4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:en100_ethernet_module_modbus_tcp_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"71DCD4E3-9BA4-44CE-BFCC-6659258FCE31\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:en100_ethernet_module_modbus_tcp:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"48118739-31B9-4600-8856-D7E9870479E7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:en100_ethernet_module_profinet_io_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0C2FA062-EBFE-457F-988E-60A9317212A4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:en100_ethernet_module_profinet_io:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"11199473-60BF-42AB-B6F0-BEF9663C67B7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:en100_ethernet_module_iec_61850_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"4.30\",\"matchCriteriaId\":\"42ABCFB1-0D86-47DB-8257-370B70E1C969\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:en100_ethernet_module_iec_61850:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3C5EC8F7-6CD2-461B-9D06-2D9F4D083A98\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-18-067-01\",\"source\":\"nvd@nist.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…