CVE-2018-4848 (GCVE-0-2018-4848)

Vulnerability from cvelistv5 – Published: 2018-06-14 00:00 – Updated: 2024-08-05 05:18
VLAI?
Summary
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.
Severity ?
No CVSS data available.
CWE
  • CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T05:18:26.424Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "104494",
            "tags": [
              "vdb-entry",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/104494"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480829.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.3"
            }
          ]
        },
        {
          "product": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.4.1"
            }
          ]
        },
        {
          "product": "SCALANCE X-200RNA switch family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.7"
            }
          ]
        },
        {
          "product": "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        }
      ],
      "datePublic": "2018-06-12T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.4.1), SCALANCE X-200RNA switch family (All versions \u003c V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.3). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-80",
              "description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-13T00:00:00",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "name": "104494",
          "tags": [
            "vdb-entry"
          ],
          "url": "http://www.securityfocus.com/bid/104494"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-480829.pdf"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2018-4848",
    "datePublished": "2018-06-14T00:00:00",
    "dateReserved": "2018-01-02T00:00:00",
    "dateUpdated": "2024-08-05T05:18:26.424Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_x300_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"42E2C599-41E1-473A-8E05-011C5DE120D1\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_x300:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E3F6299B-D7E3-4750-B016-7DCBC83C2287\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:scalance_x-200_irt_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"5.4.1\", \"matchCriteriaId\": \"0A7C433F-2FA4-4FA0-8167-152659EB8D35\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_x-200_irt:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8503130C-ED23-48E8-8093-83894883EBF2\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:h:siemens:scalance_x-200_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"5.2.3\", \"matchCriteriaId\": \"0DF2914E-33E6-4036-A971-E6D1711B8E77\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:scalance_x-200:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6FEF9F9F-4066-483B-BF95-3BA5625284DF\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.4.1), SCALANCE X-200RNA switch family (All versions \u003c V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.3). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en la familia de conmutadores SCALANCE X-200 (incluidas las variantes SIPLUS NET) (todas las versiones anteriores a la versi\\u00f3n V5.2.3), familia de conmutadores SCALANCE X-200IRT (incluidas las variantes SIPLUS NET) (todas las versiones anteriores a la versi\\u00f3n V5.4.1), Familia de conmutadores SCALANCE X-300 (incluidas las variantes X408 y SIPLUS NET) (Todas las versiones anteriores a la versi\\u00f3n V4.1.3). El servidor web de configuraci\\u00f3n integrado de los interruptores Scalance X afectados podr\\u00eda permitir ataques Cross-Site Scripting (XSS) si los usuarios desprevenidos son enga\\u00f1ados para acceder a un enlace malicioso. Se requiere la interacci\\u00f3n del usuario para una explotaci\\u00f3n exitosa. El usuario debe iniciar sesi\\u00f3n en la interfaz web para que la explotaci\\u00f3n tenga \\u00e9xito. En la etapa de publicaci\\u00f3n de este aviso de seguridad no se conoce explotaci\\u00f3n p\\u00fablica. El proveedor ha confirmado la vulnerabilidad y proporciona mitigaciones para resolverla.\"}]",
      "id": "CVE-2018-4848",
      "lastModified": "2024-11-21T04:07:34.740",
      "metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 6.1, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 2.7}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:N/I:P/A:N\", \"baseScore\": 4.3, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
      "published": "2018-06-14T16:29:00.490",
      "references": "[{\"url\": \"http://www.securityfocus.com/bid/104494\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-480829.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Third Party Advisory\", \"Vendor Advisory\"]}, {\"url\": \"http://www.securityfocus.com/bid/104494\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-480829.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"Vendor Advisory\"]}]",
      "sourceIdentifier": "productcert@siemens.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-80\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2018-4848\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2018-06-14T16:29:00.490\",\"lastModified\":\"2024-11-21T04:07:34.740\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.4.1), SCALANCE X-200RNA switch family (All versions \u003c V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.3). The integrated configuration web server of the affected devices could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en la familia de conmutadores SCALANCE X-200 (incluidas las variantes SIPLUS NET) (todas las versiones anteriores a la versi\u00f3n V5.2.3), familia de conmutadores SCALANCE X-200IRT (incluidas las variantes SIPLUS NET) (todas las versiones anteriores a la versi\u00f3n V5.4.1), Familia de conmutadores SCALANCE X-300 (incluidas las variantes X408 y SIPLUS NET) (Todas las versiones anteriores a la versi\u00f3n V4.1.3). El servidor web de configuraci\u00f3n integrado de los interruptores Scalance X afectados podr\u00eda permitir ataques Cross-Site Scripting (XSS) si los usuarios desprevenidos son enga\u00f1ados para acceder a un enlace malicioso. Se requiere la interacci\u00f3n del usuario para una explotaci\u00f3n exitosa. El usuario debe iniciar sesi\u00f3n en la interfaz web para que la explotaci\u00f3n tenga \u00e9xito. En la etapa de publicaci\u00f3n de este aviso de seguridad no se conoce explotaci\u00f3n p\u00fablica. El proveedor ha confirmado la vulnerabilidad y proporciona mitigaciones para resolverla.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:P/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-80\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x300_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"42E2C599-41E1-473A-8E05-011C5DE120D1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E3F6299B-D7E3-4750-B016-7DCBC83C2287\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:scalance_x-200_irt_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.4.1\",\"matchCriteriaId\":\"0A7C433F-2FA4-4FA0-8167-152659EB8D35\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x-200_irt:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8503130C-ED23-48E8-8093-83894883EBF2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:h:siemens:scalance_x-200_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.2.3\",\"matchCriteriaId\":\"0DF2914E-33E6-4036-A971-E6D1711B8E77\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:scalance_x-200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6FEF9F9F-4066-483B-BF95-3BA5625284DF\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/104494\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-480829.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/104494\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-480829.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…