CVE-2018-7116 (GCVE-0-2018-7116)

Vulnerability from cvelistv5 – Published: 2018-12-03 15:00 – Updated: 2024-08-05 06:17
VLAI
Summary
HPE Intelligent Management Center (IMC) prior to IMC PLAT 7.3 (E0605P06) is vulnerable to a remote denial of service via dbman Opcode 10003 'Filename'. This problem is resolved in IMC PLAT 7.3 (E0605P06) or subsequent versions.
CWE
  • remote denial of service
Assigner
hpe
References
Impacted products
Date Public
2018-12-03 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:17:17.600Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "1042182",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1042182"
          },
          {
            "name": "106211",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/106211"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03906en_us"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.hpe.com/hpsc/doc/public/display?docId=hpesbhf03906en_us"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "HPE Intelligent Management Center (IMC)",
          "vendor": "Hewlett Packard Enterprise",
          "versions": [
            {
              "status": "affected",
              "version": "prior to IMC PLAT 7.3 (E0605P06)"
            }
          ]
        }
      ],
      "datePublic": "2018-12-03T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "HPE Intelligent Management Center (IMC) prior to IMC PLAT 7.3 (E0605P06) is vulnerable to a remote denial of service via dbman Opcode 10003 \u0027Filename\u0027. This problem is resolved in IMC PLAT 7.3 (E0605P06) or subsequent versions."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "remote denial of service",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-12-15T10:57:01.000Z",
        "orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
        "shortName": "hpe"
      },
      "references": [
        {
          "name": "1042182",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1042182"
        },
        {
          "name": "106211",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/106211"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03906en_us"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.hpe.com/hpsc/doc/public/display?docId=hpesbhf03906en_us"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security-alert@hpe.com",
          "ID": "CVE-2018-7116",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "HPE Intelligent Management Center (IMC)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "prior to IMC PLAT 7.3 (E0605P06)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Hewlett Packard Enterprise"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "HPE Intelligent Management Center (IMC) prior to IMC PLAT 7.3 (E0605P06) is vulnerable to a remote denial of service via dbman Opcode 10003 \u0027Filename\u0027. This problem is resolved in IMC PLAT 7.3 (E0605P06) or subsequent versions."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "remote denial of service"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "1042182",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1042182"
            },
            {
              "name": "106211",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/106211"
            },
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03906en_us",
              "refsource": "CONFIRM",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03906en_us"
            },
            {
              "name": "https://support.hpe.com/hpsc/doc/public/display?docId=hpesbhf03906en_us",
              "refsource": "MISC",
              "url": "https://support.hpe.com/hpsc/doc/public/display?docId=hpesbhf03906en_us"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
    "assignerShortName": "hpe",
    "cveId": "CVE-2018-7116",
    "datePublished": "2018-12-03T15:00:00.000Z",
    "dateReserved": "2018-02-15T00:00:00.000Z",
    "dateUpdated": "2024-08-05T06:17:17.600Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2018-7116",
      "date": "2026-07-27",
      "epss": "0.10304",
      "percentile": "0.95211"
    },
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:hp:intelligent_management_center:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"7.3\", \"matchCriteriaId\": \"70962382-6FA5-4E21-81D8-09FE48D77A54\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:hp:intelligent_management_center:7.3:-:*:*:*:*:*:*\", \"matchCriteriaId\": \"7AA88901-0BB2-46C5-AAA4-38D41EE656F9\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:hp:intelligent_management_center:7.3:e0503:*:*:*:*:*:*\", \"matchCriteriaId\": \"B8A100F0-6CAE-4705-A2ED-862D0016E3DA\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:hp:intelligent_management_center:7.3:e0504:*:*:*:*:*:*\", \"matchCriteriaId\": \"F5F6C54E-D905-49E3-B848-8401E0B41B5E\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:hp:intelligent_management_center:7.3:e0504p02:*:*:*:*:*:*\", \"matchCriteriaId\": \"16728216-DDCF-4842-9C7F-02FE7E055E70\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:hp:intelligent_management_center:7.3:e0504p04:*:*:*:*:*:*\", \"matchCriteriaId\": \"0FC4C972-D942-40A3-AFDE-A3A2B34416BB\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:hp:intelligent_management_center:7.3:e0506:*:*:*:*:*:*\", \"matchCriteriaId\": \"394C1F2C-5852-4A99-82AD-1B874E8F4164\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:hp:intelligent_management_center:7.3:e0506p03:*:*:*:*:*:*\", \"matchCriteriaId\": \"EB8C4E2F-25CF-4949-A6FE-7FDF6F27B36D\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:hp:intelligent_management_center:7.3:e0506p07:*:*:*:*:*:*\", \"matchCriteriaId\": \"8344F117-C492-4FF9-A982-B7293E62C5F4\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:hp:intelligent_management_center:7.3:e0506p09:*:*:*:*:*:*\", \"matchCriteriaId\": \"C98D14C4-58E4-4D59-84D5-02C87D461583\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:hp:intelligent_management_center:7.3:e0605:*:*:*:*:*:*\", \"matchCriteriaId\": \"187532C0-EF39-4730-9D3C-0C573B2A0318\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:hp:intelligent_management_center:7.3:e0605h02:*:*:*:*:*:*\", \"matchCriteriaId\": \"03CE933B-B0A7-4C1C-A273-84845685210F\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:hp:intelligent_management_center:7.3:e0605h05:*:*:*:*:*:*\", \"matchCriteriaId\": \"1DEA8788-5476-41ED-9546-39D4FCD24EC9\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:hp:intelligent_management_center:7.3:e0605p04:*:*:*:*:*:*\", \"matchCriteriaId\": \"D906EEE0-33F5-4566-93A2-8783AD88582F\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"HPE Intelligent Management Center (IMC) prior to IMC PLAT 7.3 (E0605P06) is vulnerable to a remote denial of service via dbman Opcode 10003 \u0027Filename\u0027. This problem is resolved in IMC PLAT 7.3 (E0605P06) or subsequent versions.\"}, {\"lang\": \"es\", \"value\": \"HPE Intelligent Management Center (IMC) en versiones anteriores a IMC PLAT 7.3 (E0605P06) es vulnerable a una denegaci\\u00f3n de servicio (DoS) remota mediante dbman Opcode 10003 \\\"Filename\\\". El problema se ha resuelto en IMC PLAT 7.3 E0605P06 o en versiones posteriores.\"}]",
      "id": "CVE-2018-7116",
      "lastModified": "2024-11-21T04:11:40.270",
      "metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:N/I:N/A:P\", \"baseScore\": 5.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2018-12-03T15:29:00.743",
      "references": "[{\"url\": \"http://www.securityfocus.com/bid/106211\", \"source\": \"security-alert@hpe.com\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"http://www.securitytracker.com/id/1042182\", \"source\": \"security-alert@hpe.com\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://support.hpe.com/hpsc/doc/public/display?docId=hpesbhf03906en_us\", \"source\": \"security-alert@hpe.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03906en_us\", \"source\": \"security-alert@hpe.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"http://www.securityfocus.com/bid/106211\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"http://www.securitytracker.com/id/1042182\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://support.hpe.com/hpsc/doc/public/display?docId=hpesbhf03906en_us\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03906en_us\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "security-alert@hpe.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-119\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2018-7116\",\"sourceIdentifier\":\"security-alert@hpe.com\",\"published\":\"2018-12-03T15:29:00.743\",\"lastModified\":\"2024-11-21T04:11:40.270\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"HPE Intelligent Management Center (IMC) prior to IMC PLAT 7.3 (E0605P06) is vulnerable to a remote denial of service via dbman Opcode 10003 \u0027Filename\u0027. This problem is resolved in IMC PLAT 7.3 (E0605P06) or subsequent versions.\"},{\"lang\":\"es\",\"value\":\"HPE Intelligent Management Center (IMC) en versiones anteriores a IMC PLAT 7.3 (E0605P06) es vulnerable a una denegaci\u00f3n de servicio (DoS) remota mediante dbman Opcode 10003 \\\"Filename\\\". El problema se ha resuelto en IMC PLAT 7.3 E0605P06 o en versiones posteriores.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-119\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:hp:intelligent_management_center:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"7.3\",\"matchCriteriaId\":\"70962382-6FA5-4E21-81D8-09FE48D77A54\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:hp:intelligent_management_center:7.3:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"7AA88901-0BB2-46C5-AAA4-38D41EE656F9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:hp:intelligent_management_center:7.3:e0503:*:*:*:*:*:*\",\"matchCriteriaId\":\"B8A100F0-6CAE-4705-A2ED-862D0016E3DA\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:hp:intelligent_management_center:7.3:e0504:*:*:*:*:*:*\",\"matchCriteriaId\":\"F5F6C54E-D905-49E3-B848-8401E0B41B5E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:hp:intelligent_management_center:7.3:e0504p02:*:*:*:*:*:*\",\"matchCriteriaId\":\"16728216-DDCF-4842-9C7F-02FE7E055E70\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:hp:intelligent_management_center:7.3:e0504p04:*:*:*:*:*:*\",\"matchCriteriaId\":\"0FC4C972-D942-40A3-AFDE-A3A2B34416BB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:hp:intelligent_management_center:7.3:e0506:*:*:*:*:*:*\",\"matchCriteriaId\":\"394C1F2C-5852-4A99-82AD-1B874E8F4164\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:hp:intelligent_management_center:7.3:e0506p03:*:*:*:*:*:*\",\"matchCriteriaId\":\"EB8C4E2F-25CF-4949-A6FE-7FDF6F27B36D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:hp:intelligent_management_center:7.3:e0506p07:*:*:*:*:*:*\",\"matchCriteriaId\":\"8344F117-C492-4FF9-A982-B7293E62C5F4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:hp:intelligent_management_center:7.3:e0506p09:*:*:*:*:*:*\",\"matchCriteriaId\":\"C98D14C4-58E4-4D59-84D5-02C87D461583\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:hp:intelligent_management_center:7.3:e0605:*:*:*:*:*:*\",\"matchCriteriaId\":\"187532C0-EF39-4730-9D3C-0C573B2A0318\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:hp:intelligent_management_center:7.3:e0605h02:*:*:*:*:*:*\",\"matchCriteriaId\":\"03CE933B-B0A7-4C1C-A273-84845685210F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:hp:intelligent_management_center:7.3:e0605h05:*:*:*:*:*:*\",\"matchCriteriaId\":\"1DEA8788-5476-41ED-9546-39D4FCD24EC9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:hp:intelligent_management_center:7.3:e0605p04:*:*:*:*:*:*\",\"matchCriteriaId\":\"D906EEE0-33F5-4566-93A2-8783AD88582F\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/106211\",\"source\":\"security-alert@hpe.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://www.securitytracker.com/id/1042182\",\"source\":\"security-alert@hpe.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://support.hpe.com/hpsc/doc/public/display?docId=hpesbhf03906en_us\",\"source\":\"security-alert@hpe.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03906en_us\",\"source\":\"security-alert@hpe.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/106211\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"http://www.securitytracker.com/id/1042182\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://support.hpe.com/hpsc/doc/public/display?docId=hpesbhf03906en_us\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbhf03906en_us\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Loading…