cve-2018-7942
Vulnerability from cvelistv5
Published
2018-05-24 14:00
Modified
2024-08-05 06:37
Severity ?
Summary
The iBMC (Intelligent Baseboard Management Controller) of some Huawei servers have an authentication bypass vulnerability. An unauthenticated, remote attacker may send some specially crafted messages to the affected products. Due to improper authentication design, successful exploit may cause some information leak.
Impacted products
Vendor Product Version
Huawei Technologies Co., Ltd. 1288H V5; 2288H V5; 2488 V5; CH121 V3; CH121L V3; CH121L V5; CH121 V5; CH140 V3; CH140L V3; CH220 V3; CH222 V3; CH242 V3; CH242 V5; RH1288 V3; RH2288 V3; RH2288H V3; XH310 V3; XH321 V3; XH321 V5; XH620 V3 Version: 1288H V5 V100R005C00
Version: 2288H V5 V100R005C00
Version: 2488 V5 V100R005C00
Version: CH121 V3 V100R001C00
Version: CH121L V3 V100R001C00
Version: CH121L V5 V100R001C00
Version: CH121 V5 V100R001C00
Version: CH140 V3 V100R001C00
Version: CH140L V3 V100R001C00
Version: CH220 V3 V100R001C00
Version: CH222 V3 V100R001C00
Version: CH242 V3 V100R001C00
Version: CH242 V5 V100R001C00
Version: RH1288 V3 V100R003C00
Version: RH2288 V3 V100R003C00
Version: RH2288H V3 V100R003C00
Version: XH310 V3 V100R003C00
Version: XH321 V3 V100R003C00
Version: XH321 V5 V100R005C00
Version: XH620 V3 V100R003C00
Create a notification for this product.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T06:37:59.683Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20180523-01-server-en"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "1288H V5; 2288H V5; 2488 V5; CH121 V3; CH121L V3; CH121L V5; CH121 V5; CH140 V3; CH140L V3; CH220 V3; CH222 V3; CH242 V3; CH242 V5; RH1288 V3; RH2288 V3; RH2288H V3; XH310 V3; XH321 V3; XH321 V5; XH620 V3",
          "vendor": "Huawei Technologies Co., Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "1288H V5 V100R005C00"
            },
            {
              "status": "affected",
              "version": "2288H V5 V100R005C00"
            },
            {
              "status": "affected",
              "version": "2488 V5 V100R005C00"
            },
            {
              "status": "affected",
              "version": "CH121 V3 V100R001C00"
            },
            {
              "status": "affected",
              "version": "CH121L V3 V100R001C00"
            },
            {
              "status": "affected",
              "version": "CH121L V5 V100R001C00"
            },
            {
              "status": "affected",
              "version": "CH121 V5 V100R001C00"
            },
            {
              "status": "affected",
              "version": "CH140 V3 V100R001C00"
            },
            {
              "status": "affected",
              "version": "CH140L V3 V100R001C00"
            },
            {
              "status": "affected",
              "version": "CH220 V3 V100R001C00"
            },
            {
              "status": "affected",
              "version": "CH222 V3 V100R001C00"
            },
            {
              "status": "affected",
              "version": "CH242 V3 V100R001C00"
            },
            {
              "status": "affected",
              "version": "CH242 V5 V100R001C00"
            },
            {
              "status": "affected",
              "version": "RH1288 V3 V100R003C00"
            },
            {
              "status": "affected",
              "version": "RH2288 V3 V100R003C00"
            },
            {
              "status": "affected",
              "version": "RH2288H V3 V100R003C00"
            },
            {
              "status": "affected",
              "version": "XH310 V3 V100R003C00"
            },
            {
              "status": "affected",
              "version": "XH321 V3 V100R003C00"
            },
            {
              "status": "affected",
              "version": "XH321 V5 V100R005C00"
            },
            {
              "status": "affected",
              "version": "XH620 V3 V100R003C00"
            }
          ]
        }
      ],
      "datePublic": "2018-05-23T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The iBMC (Intelligent Baseboard Management Controller) of some Huawei servers have an authentication bypass vulnerability. An unauthenticated, remote attacker may send some specially crafted messages to the affected products. Due to improper authentication design, successful exploit may cause some information leak."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "authentication bypass",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-05-24T13:57:01",
        "orgId": "25ac1063-e409-4190-8079-24548c77ea2e",
        "shortName": "huawei"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20180523-01-server-en"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@huawei.com",
          "ID": "CVE-2018-7942",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "1288H V5; 2288H V5; 2488 V5; CH121 V3; CH121L V3; CH121L V5; CH121 V5; CH140 V3; CH140L V3; CH220 V3; CH222 V3; CH242 V3; CH242 V5; RH1288 V3; RH2288 V3; RH2288H V3; XH310 V3; XH321 V3; XH321 V5; XH620 V3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "1288H V5 V100R005C00"
                          },
                          {
                            "version_value": "2288H V5 V100R005C00"
                          },
                          {
                            "version_value": "2488 V5 V100R005C00"
                          },
                          {
                            "version_value": "CH121 V3 V100R001C00"
                          },
                          {
                            "version_value": "CH121L V3 V100R001C00"
                          },
                          {
                            "version_value": "CH121L V5 V100R001C00"
                          },
                          {
                            "version_value": "CH121 V5 V100R001C00"
                          },
                          {
                            "version_value": "CH140 V3 V100R001C00"
                          },
                          {
                            "version_value": "CH140L V3 V100R001C00"
                          },
                          {
                            "version_value": "CH220 V3 V100R001C00"
                          },
                          {
                            "version_value": "CH222 V3 V100R001C00"
                          },
                          {
                            "version_value": "CH242 V3 V100R001C00"
                          },
                          {
                            "version_value": "CH242 V5 V100R001C00"
                          },
                          {
                            "version_value": "RH1288 V3 V100R003C00"
                          },
                          {
                            "version_value": "RH2288 V3 V100R003C00"
                          },
                          {
                            "version_value": "RH2288H V3 V100R003C00"
                          },
                          {
                            "version_value": "XH310 V3 V100R003C00"
                          },
                          {
                            "version_value": "XH321 V3 V100R003C00"
                          },
                          {
                            "version_value": "XH321 V5 V100R005C00"
                          },
                          {
                            "version_value": "XH620 V3 V100R003C00"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Huawei Technologies Co., Ltd."
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The iBMC (Intelligent Baseboard Management Controller) of some Huawei servers have an authentication bypass vulnerability. An unauthenticated, remote attacker may send some specially crafted messages to the affected products. Due to improper authentication design, successful exploit may cause some information leak."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "authentication bypass"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20180523-01-server-en",
              "refsource": "CONFIRM",
              "url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20180523-01-server-en"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "25ac1063-e409-4190-8079-24548c77ea2e",
    "assignerShortName": "huawei",
    "cveId": "CVE-2018-7942",
    "datePublished": "2018-05-24T14:00:00",
    "dateReserved": "2018-03-09T00:00:00",
    "dateUpdated": "2024-08-05T06:37:59.683Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:huawei:1288h_v5_firmware:100r005c00:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"970A03A9-3BD3-47CB-AE3E-DC6C354BB900\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:huawei:1288h_v5:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A97FE467-E5EB-45B4-B7EA-2E8232307CEE\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:huawei:2288h_v5_firmware:100r005c00:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E6CF6E61-7CF1-4CEF-9282-17102E56B38E\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:huawei:2288h_v5:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0E01F546-8E5E-4A5A-B921-DF985FF1D7ED\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:huawei:2488_v5_firmware:100r005c00:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5D757021-44CA-4B8D-A194-7B0DEE47E5B1\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:huawei:2488_v5:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C8494E22-C84A-4201-96A3-02D8CBAC7C02\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:huawei:ch242_v3_firmware:100r001c00:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E85B51FC-9C85-4B5C-B544-40D1B02F06EC\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:huawei:ch242_v3:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D2637E43-1937-4320-AAF4-3770C332B66E\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:huawei:ch121l_v3_firmware:100r001c00:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7ACA0F25-613F-4D42-B634-6B7D3E57E3F4\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:huawei:ch121l_v3:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"58588D8E-57C2-466C-96DD-B7F679AC7EA7\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:huawei:ch121l_v5_firmware:100r001c00:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"57EFD6C9-5A39-4D9A-824E-6DD1B51C47D8\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:huawei:ch121l_v5:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4F9F3B0F-41E5-4846-B572-5EDB4BAE50F2\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:huawei:ch121_v3_firmware:100r001c00:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5283ACDA-CCB2-47F6-BCB6-5085E93B9F6F\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:huawei:ch121_v3:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2FF9E151-2924-47F8-A20B-E413C548F9AA\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"The iBMC (Intelligent Baseboard Management Controller) of some Huawei servers have an authentication bypass vulnerability. An unauthenticated, remote attacker may send some specially crafted messages to the affected products. Due to improper authentication design, successful exploit may cause some information leak.\"}, {\"lang\": \"es\", \"value\": \"iBMC (Intelligent Baseboard Management Controller) en algunos servidores Huawei tiene una vulnerabilidad de omisi\\u00f3n de autenticaci\\u00f3n. Un atacante remoto no autenticado podr\\u00eda enviar algunos mensajes especialmente manipulados a los productos afectados. Debido al dise\\u00f1o incorrecto de la autenticaci\\u00f3n, su explotaci\\u00f3n con \\u00e9xito podr\\u00eda provocar un filtrado de informaci\\u00f3n.\"}]",
      "id": "CVE-2018-7942",
      "lastModified": "2024-11-21T04:12:59.950",
      "metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:N/A:N\", \"baseScore\": 5.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2018-05-24T14:29:00.610",
      "references": "[{\"url\": \"http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20180523-01-server-en\", \"source\": \"psirt@huawei.com\", \"tags\": [\"Broken Link\"]}, {\"url\": \"https://exchange.xforce.ibmcloud.com/vulnerabilities/143686\", \"source\": \"nvd@nist.gov\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20180523-01-server-en\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Broken Link\"]}]",
      "sourceIdentifier": "psirt@huawei.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-noinfo\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2018-7942\",\"sourceIdentifier\":\"psirt@huawei.com\",\"published\":\"2018-05-24T14:29:00.610\",\"lastModified\":\"2024-11-21T04:12:59.950\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The iBMC (Intelligent Baseboard Management Controller) of some Huawei servers have an authentication bypass vulnerability. An unauthenticated, remote attacker may send some specially crafted messages to the affected products. Due to improper authentication design, successful exploit may cause some information leak.\"},{\"lang\":\"es\",\"value\":\"iBMC (Intelligent Baseboard Management Controller) en algunos servidores Huawei tiene una vulnerabilidad de omisi\u00f3n de autenticaci\u00f3n. Un atacante remoto no autenticado podr\u00eda enviar algunos mensajes especialmente manipulados a los productos afectados. Debido al dise\u00f1o incorrecto de la autenticaci\u00f3n, su explotaci\u00f3n con \u00e9xito podr\u00eda provocar un filtrado de informaci\u00f3n.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:huawei:1288h_v5_firmware:100r005c00:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"970A03A9-3BD3-47CB-AE3E-DC6C354BB900\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:huawei:1288h_v5:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A97FE467-E5EB-45B4-B7EA-2E8232307CEE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:huawei:2288h_v5_firmware:100r005c00:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E6CF6E61-7CF1-4CEF-9282-17102E56B38E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:huawei:2288h_v5:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0E01F546-8E5E-4A5A-B921-DF985FF1D7ED\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:huawei:2488_v5_firmware:100r005c00:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5D757021-44CA-4B8D-A194-7B0DEE47E5B1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:huawei:2488_v5:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C8494E22-C84A-4201-96A3-02D8CBAC7C02\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:huawei:ch242_v3_firmware:100r001c00:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E85B51FC-9C85-4B5C-B544-40D1B02F06EC\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:huawei:ch242_v3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D2637E43-1937-4320-AAF4-3770C332B66E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:huawei:ch121l_v3_firmware:100r001c00:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7ACA0F25-613F-4D42-B634-6B7D3E57E3F4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:huawei:ch121l_v3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"58588D8E-57C2-466C-96DD-B7F679AC7EA7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:huawei:ch121l_v5_firmware:100r001c00:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"57EFD6C9-5A39-4D9A-824E-6DD1B51C47D8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:huawei:ch121l_v5:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4F9F3B0F-41E5-4846-B572-5EDB4BAE50F2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:huawei:ch121_v3_firmware:100r001c00:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5283ACDA-CCB2-47F6-BCB6-5085E93B9F6F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:huawei:ch121_v3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2FF9E151-2924-47F8-A20B-E413C548F9AA\"}]}]}],\"references\":[{\"url\":\"http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20180523-01-server-en\",\"source\":\"psirt@huawei.com\",\"tags\":[\"Broken Link\"]},{\"url\":\"https://exchange.xforce.ibmcloud.com/vulnerabilities/143686\",\"source\":\"nvd@nist.gov\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20180523-01-server-en\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Broken Link\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.