cve-2019-0105
Vulnerability from cvelistv5
Published
2019-02-18 17:00
Modified
2024-09-16 23:11
Severity ?
Summary
Insufficient file permissions checking in install routine for Intel(R) Data Center Manager SDK before version 5.0.2 may allow authenticated user to potentially enable escalation of privilege via local access.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T17:37:07.543Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-050-01"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00215.html"
          },
          {
            "name": "107069",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/107069"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2019-02-12T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Insufficient file permissions checking in install routine for Intel(R) Data Center Manager SDK before version 5.0.2 may allow authenticated user to potentially enable escalation of privilege via local access."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-02-27T21:57:01",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-050-01"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00215.html"
        },
        {
          "name": "107069",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/107069"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@intel.com",
          "DATE_PUBLIC": "2019-02-12T00:00:00",
          "ID": "CVE-2019-0105",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Insufficient file permissions checking in install routine for Intel(R) Data Center Manager SDK before version 5.0.2 may allow authenticated user to potentially enable escalation of privilege via local access."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-050-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-050-01"
            },
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00215.html",
              "refsource": "CONFIRM",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00215.html"
            },
            {
              "name": "107069",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/107069"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2019-0105",
    "datePublished": "2019-02-18T17:00:00Z",
    "dateReserved": "2018-11-13T00:00:00",
    "dateUpdated": "2024-09-16T23:11:53.609Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:intel:data_center_manager:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"5.0.2\", \"matchCriteriaId\": \"A9CFEB9D-54FC-4F61-851D-37D4CACCC09F\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Insufficient file permissions checking in install routine for Intel(R) Data Center Manager SDK before version 5.0.2 may allow authenticated user to potentially enable escalation of privilege via local access.\"}, {\"lang\": \"es\", \"value\": \"Una comprobaci\\u00f3n de permisos insuficiente en una rutina de instalaci\\u00f3n para Intel \\u00ae Data Center Manager SDK, en versiones anteriores a la 5.0.2, podr\\u00eda permitir a un usuario autenticado habilitar un escalado de privilegios mediante un acceso local.\"}]",
      "id": "CVE-2019-0105",
      "lastModified": "2024-11-21T04:16:14.350",
      "metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:L/AC:L/Au:N/C:P/I:P/A:P\", \"baseScore\": 4.6, \"accessVector\": \"LOCAL\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 3.9, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2019-02-18T17:29:00.533",
      "references": "[{\"url\": \"http://www.securityfocus.com/bid/107069\", \"source\": \"secure@intel.com\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-19-050-01\", \"source\": \"secure@intel.com\", \"tags\": [\"Mitigation\", \"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00215.html\", \"source\": \"secure@intel.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"http://www.securityfocus.com/bid/107069\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://ics-cert.us-cert.gov/advisories/ICSA-19-050-01\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Mitigation\", \"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00215.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "secure@intel.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-863\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2019-0105\",\"sourceIdentifier\":\"secure@intel.com\",\"published\":\"2019-02-18T17:29:00.533\",\"lastModified\":\"2024-11-21T04:16:14.350\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Insufficient file permissions checking in install routine for Intel(R) Data Center Manager SDK before version 5.0.2 may allow authenticated user to potentially enable escalation of privilege via local access.\"},{\"lang\":\"es\",\"value\":\"Una comprobaci\u00f3n de permisos insuficiente en una rutina de instalaci\u00f3n para Intel \u00ae Data Center Manager SDK, en versiones anteriores a la 5.0.2, podr\u00eda permitir a un usuario autenticado habilitar un escalado de privilegios mediante un acceso local.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:L/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":4.6,\"accessVector\":\"LOCAL\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":3.9,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-863\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:intel:data_center_manager:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"5.0.2\",\"matchCriteriaId\":\"A9CFEB9D-54FC-4F61-851D-37D4CACCC09F\"}]}]}],\"references\":[{\"url\":\"http://www.securityfocus.com/bid/107069\",\"source\":\"secure@intel.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-19-050-01\",\"source\":\"secure@intel.com\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00215.html\",\"source\":\"secure@intel.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"http://www.securityfocus.com/bid/107069\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://ics-cert.us-cert.gov/advisories/ICSA-19-050-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/INTEL-SA-00215.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.