CVE-2019-10972 (GCVE-0-2019-10972)

Vulnerability from cvelistv5 – Published: 2019-07-25 23:31 – Updated: 2024-08-04 22:40
VLAI?
Summary
Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability can be triggered when an attacker provides the target with a rogue project file (.frc2). Once a user opens the rogue project, CPU exhaustion occurs, which causes the software to quit responding until the application is restarted.
Severity ?
No CVSS data available.
CWE
  • CWE-400 - UNCONTROLLED RESOURCE CONSUMPTION CWE-400
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.483Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-19-204-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Mitsubishi Electric FR Configurator2",
          "vendor": "Mitsubishi Electric",
          "versions": [
            {
              "status": "affected",
              "version": "Version 1.16S and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability can be triggered when an attacker provides the target with a rogue project file (.frc2). Once a user opens the rogue project, CPU exhaustion occurs, which causes the software to quit responding until the application is restarted."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "UNCONTROLLED RESOURCE CONSUMPTION CWE-400",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-07-25T23:31:47",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-19-204-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2019-10972",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Mitsubishi Electric FR Configurator2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Version 1.16S and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Mitsubishi Electric"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability can be triggered when an attacker provides the target with a rogue project file (.frc2). Once a user opens the rogue project, CPU exhaustion occurs, which causes the software to quit responding until the application is restarted."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "UNCONTROLLED RESOURCE CONSUMPTION CWE-400"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-19-204-01",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-19-204-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-10972",
    "datePublished": "2019-07-25T23:31:47",
    "dateReserved": "2019-04-08T00:00:00",
    "dateUpdated": "2024-08-04T22:40:15.483Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:mitsubishielectric:electric_fr_configurator2:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"1.16s\", \"matchCriteriaId\": \"7B582A19-3A57-41C4-AC41-1D6154106044\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability can be triggered when an attacker provides the target with a rogue project file (.frc2). Once a user opens the rogue project, CPU exhaustion occurs, which causes the software to quit responding until the application is restarted.\"}, {\"lang\": \"es\", \"value\": \"FR Configurator2 de Mitsubishi Electric, versi\\u00f3n 1.16S y anteriores. Esta vulnerabilidad puede ser activada cuando un atacante proporciona a la victima un archivo de proyecto no autorizado (.frc2). Una vez que un usuario abre el proyecto no autorizado, ocurre un agotamiento de la CPU, lo que causa que el software deje de responder hasta que se reinicie la aplicaci\\u00f3n.\"}]",
      "id": "CVE-2019-10972",
      "lastModified": "2024-11-21T04:20:16.380",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\", \"baseScore\": 5.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:N/I:N/A:C\", \"baseScore\": 7.1, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 8.6, \"impactScore\": 6.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
      "published": "2019-07-26T00:15:11.277",
      "references": "[{\"url\": \"https://www.us-cert.gov/ics/advisories/icsa-19-204-01\", \"source\": \"ics-cert@hq.dhs.gov\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}, {\"url\": \"https://www.us-cert.gov/ics/advisories/icsa-19-204-01\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"US Government Resource\"]}]",
      "sourceIdentifier": "ics-cert@hq.dhs.gov",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"ics-cert@hq.dhs.gov\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-400\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-770\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2019-10972\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2019-07-26T00:15:11.277\",\"lastModified\":\"2024-11-21T04:20:16.380\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability can be triggered when an attacker provides the target with a rogue project file (.frc2). Once a user opens the rogue project, CPU exhaustion occurs, which causes the software to quit responding until the application is restarted.\"},{\"lang\":\"es\",\"value\":\"FR Configurator2 de Mitsubishi Electric, versi\u00f3n 1.16S y anteriores. Esta vulnerabilidad puede ser activada cuando un atacante proporciona a la victima un archivo de proyecto no autorizado (.frc2). Una vez que un usuario abre el proyecto no autorizado, ocurre un agotamiento de la CPU, lo que causa que el software deje de responder hasta que se reinicie la aplicaci\u00f3n.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:N/A:C\",\"baseScore\":7.1,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.6,\"impactScore\":6.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-770\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:mitsubishielectric:electric_fr_configurator2:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"1.16s\",\"matchCriteriaId\":\"7B582A19-3A57-41C4-AC41-1D6154106044\"}]}]}],\"references\":[{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-19-204-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.us-cert.gov/ics/advisories/icsa-19-204-01\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…