CVE-2019-11893 (GCVE-0-2019-11893)
Vulnerability from cvelistv5 – Published: 2019-05-29 19:58 – Updated: 2024-09-16 22:46
VLAI?
Summary
A potential incorrect privilege assignment vulnerability exists in the app permission update API of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app with restricted permissions, which required user interaction.
Severity ?
5.5 (Medium)
CWE
- CWE-266 - Incorrect Privilege Assignment
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Bosch | Smart Home Controller |
Affected:
unspecified , < 9.8.905
(custom)
|
Credits
Philip Kazmeier
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:10:29.449Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Smart Home Controller",
"vendor": "Bosch",
"versions": [
{
"lessThan": "9.8.905",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Philip Kazmeier"
}
],
"datePublic": "2019-05-29T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A potential incorrect privilege assignment vulnerability exists in the app permission update API of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app with restricted permissions, which required user interaction."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-266",
"description": "CWE-266 Incorrect Privilege Assignment",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-05-29T19:58:04",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Incorrect privilege assignment in the app permission update API of the Bosch Smart Home Controller (SHC)",
"x_generator": {
"engine": "Vulnogram 0.0.6"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@bosch.com",
"DATE_PUBLIC": "2019-05-29T12:00:00.000Z",
"ID": "CVE-2019-11893",
"STATE": "PUBLIC",
"TITLE": "Incorrect privilege assignment in the app permission update API of the Bosch Smart Home Controller (SHC)"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Smart Home Controller",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.8.905"
}
]
}
}
]
},
"vendor_name": "Bosch"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Philip Kazmeier"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A potential incorrect privilege assignment vulnerability exists in the app permission update API of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app with restricted permissions, which required user interaction."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.6"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-266 Incorrect Privilege Assignment"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html",
"refsource": "CONFIRM",
"url": "https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html"
}
]
},
"source": {
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2019-11893",
"datePublished": "2019-05-29T19:58:04.150033Z",
"dateReserved": "2019-05-13T00:00:00",
"dateUpdated": "2024-09-16T22:46:47.017Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:bosch:smart_home_controller_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"9.8.905\", \"matchCriteriaId\": \"208D1A1D-4982-457F-A29B-0BE857355DC5\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:bosch:smart_home_controller:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"83665608-FC8C-4C92-9DAD-A025433DDD33\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A potential incorrect privilege assignment vulnerability exists in the app permission update API of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app with restricted permissions, which required user interaction.\"}, {\"lang\": \"es\", \"value\": \"Existe una vulnerabilidad potencial de asignaci\\u00f3n de privilegios inapropiada en la API de actualizaci\\u00f3n de permisos de aplicaci\\u00f3n del Smart Home Controller (SHC) de Bosch anteriores de la 9.8.905, que puede conllevar a una aplicaci\\u00f3n restringida obtenga los permisos por defecto de la aplicaci\\u00f3n. Para aprovechar la vulnerabilidad, el adversario necesita haber emparejado con \\u00e9xito una aplicaci\\u00f3n con permisos restringidos, que requiere la interacci\\u00f3n del usuario.\"}]",
"id": "CVE-2019-11893",
"lastModified": "2024-11-21T04:21:58.410",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.0, \"baseSeverity\": \"HIGH\", \"attackVector\": \"ADJACENT_NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.1, \"impactScore\": 5.9}], \"cvssMetricV30\": [{\"source\": \"psirt@bosch.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\", \"baseScore\": 5.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"ADJACENT_NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"LOW\"}, \"exploitabilityScore\": 2.1, \"impactScore\": 3.4}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:A/AC:M/Au:S/C:P/I:P/A:P\", \"baseScore\": 4.9, \"accessVector\": \"ADJACENT_NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 4.4, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2019-05-29T20:29:00.297",
"references": "[{\"url\": \"https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html\", \"source\": \"psirt@bosch.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "psirt@bosch.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"psirt@bosch.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-266\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-269\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2019-11893\",\"sourceIdentifier\":\"psirt@bosch.com\",\"published\":\"2019-05-29T20:29:00.297\",\"lastModified\":\"2024-11-21T04:21:58.410\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A potential incorrect privilege assignment vulnerability exists in the app permission update API of the Bosch Smart Home Controller (SHC) before 9.8.905 that may result in a restricted app obtaining default app permissions. In order to exploit the vulnerability, the adversary needs to have successfully paired an app with restricted permissions, which required user interaction.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad potencial de asignaci\u00f3n de privilegios inapropiada en la API de actualizaci\u00f3n de permisos de aplicaci\u00f3n del Smart Home Controller (SHC) de Bosch anteriores de la 9.8.905, que puede conllevar a una aplicaci\u00f3n restringida obtenga los permisos por defecto de la aplicaci\u00f3n. Para aprovechar la vulnerabilidad, el adversario necesita haber emparejado con \u00e9xito una aplicaci\u00f3n con permisos restringidos, que requiere la interacci\u00f3n del usuario.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.0,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.1,\"impactScore\":5.9}],\"cvssMetricV30\":[{\"source\":\"psirt@bosch.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.1,\"impactScore\":3.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:A/AC:M/Au:S/C:P/I:P/A:P\",\"baseScore\":4.9,\"accessVector\":\"ADJACENT_NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":4.4,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"psirt@bosch.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-266\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-269\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:bosch:smart_home_controller_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"9.8.905\",\"matchCriteriaId\":\"208D1A1D-4982-457F-A29B-0BE857355DC5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:bosch:smart_home_controller:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"83665608-FC8C-4C92-9DAD-A025433DDD33\"}]}]}],\"references\":[{\"url\":\"https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html\",\"source\":\"psirt@bosch.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://psirt.bosch.com/Advisory/BOSCH-SA-662084.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…