CVE-2019-14925 (GCVE-0-2019-14925)
Vulnerability from cvelistv5
Published
2019-10-28 12:12
Modified
2024-09-10 17:06
Severity ?
EPSS score ?
0.28% (0.50971)
Summary
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as usernames, passwords, and other sensitive RTU data due to insecure permission assignment.
Impacted products
Vendor Product Version
n/a n/a Version: n/a
Show details on NVD website


{
   containers: {
      adp: [
         {
            providerMetadata: {
               dateUpdated: "2024-08-05T00:34:52.973Z",
               orgId: "af854a3a-2127-422b-91ae-364da2661108",
               shortName: "CVE",
            },
            references: [
               {
                  tags: [
                     "x_refsource_MISC",
                     "x_transferred",
                  ],
                  url: "https://www.mogozobo.com/",
               },
               {
                  tags: [
                     "x_refsource_MISC",
                     "x_transferred",
                  ],
                  url: "https://www.mogozobo.com/?p=3593",
               },
            ],
            title: "CVE Program Container",
         },
      ],
      cna: {
         affected: [
            {
               product: "n/a",
               vendor: "n/a",
               versions: [
                  {
                     status: "affected",
                     version: "n/a",
                  },
               ],
            },
         ],
         descriptions: [
            {
               lang: "en",
               value: "An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as usernames, passwords, and other sensitive RTU data due to insecure permission assignment.",
            },
         ],
         problemTypes: [
            {
               descriptions: [
                  {
                     description: "n/a",
                     lang: "en",
                     type: "text",
                  },
               ],
            },
         ],
         providerMetadata: {
            dateUpdated: "2024-09-10T17:06:17.053677",
            orgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            shortName: "mitre",
         },
         references: [
            {
               url: "https://www.mogozobo.com/",
            },
            {
               url: "https://www.mogozobo.com/?p=3593",
            },
         ],
      },
   },
   cveMetadata: {
      assignerOrgId: "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
      assignerShortName: "mitre",
      cveId: "CVE-2019-14925",
      datePublished: "2019-10-28T12:12:34",
      dateReserved: "2019-08-10T00:00:00",
      dateUpdated: "2024-09-10T17:06:17.053677",
      state: "PUBLISHED",
   },
   dataType: "CVE_RECORD",
   dataVersion: "5.1",
   "vulnerability-lookup:meta": {
      fkie_nvd: {
         configurations: "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:mitsubishielectric:smartrtu_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"2.02\", \"matchCriteriaId\": \"62D6CAA7-11E1-4DF2-A9BD-EC71AE7CD166\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:mitsubishielectric:smartrtu:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1EF90DA0-55C7-4765-9DEE-80145752961D\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:inea:me-rtu_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"3.0\", \"matchCriteriaId\": \"DDC6C049-B15B-4FC2-9DDF-915381E6D114\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:inea:me-rtu:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FD7F8299-4A9C-4B93-A35A-68C6D43855CC\"}]}]}]",
         descriptions: "[{\"lang\": \"en\", \"value\": \"An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as usernames, passwords, and other sensitive RTU data due to insecure permission assignment.\"}, {\"lang\": \"es\", \"value\": \"Se descubri\\u00f3 un problema en los dispositivos Mitsubishi Electric ME-RTU versiones hasta la versi\\u00f3n 2.02 y los dispositivos INEA ME-RTU versiones hasta la versi\\u00f3n 3.0. Un archivo de configuraci\\u00f3n /usr/smartrtu/init/settings.xml de tipo world-readable en el sistema de archivos le permite al atacante leer ajustes de configuraci\\u00f3n confidencial tales como nombres de usuario, contrase\\u00f1as y otros datos confidenciales de la RTU debido a una asignaci\\u00f3n de permisos no seguros.\"}]",
         id: "CVE-2019-14925",
         lastModified: "2024-11-21T04:27:41.697",
         metrics: "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 6.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:S/C:P/I:N/A:N\", \"baseScore\": 4.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
         published: "2019-10-28T13:15:10.600",
         references: "[{\"url\": \"https://www.mogozobo.com/\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.mogozobo.com/?p=3593\", \"source\": \"cve@mitre.org\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://www.mogozobo.com/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.mogozobo.com/?p=3593\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}]",
         sourceIdentifier: "cve@mitre.org",
         vulnStatus: "Modified",
         weaknesses: "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-276\"}]}]",
      },
      nvd: "{\"cve\":{\"id\":\"CVE-2019-14925\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2019-10-28T13:15:10.600\",\"lastModified\":\"2024-11-21T04:27:41.697\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as usernames, passwords, and other sensitive RTU data due to insecure permission assignment.\"},{\"lang\":\"es\",\"value\":\"Se descubrió un problema en los dispositivos Mitsubishi Electric ME-RTU versiones hasta la versión 2.02 y los dispositivos INEA ME-RTU versiones hasta la versión 3.0. Un archivo de configuración /usr/smartrtu/init/settings.xml de tipo world-readable en el sistema de archivos le permite al atacante leer ajustes de configuración confidencial tales como nombres de usuario, contraseñas y otros datos confidenciales de la RTU debido a una asignación de permisos no seguros.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:N/A:N\",\"baseScore\":4.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-276\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:smartrtu_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.02\",\"matchCriteriaId\":\"62D6CAA7-11E1-4DF2-A9BD-EC71AE7CD166\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:smartrtu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1EF90DA0-55C7-4765-9DEE-80145752961D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:inea:me-rtu_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"3.0\",\"matchCriteriaId\":\"DDC6C049-B15B-4FC2-9DDF-915381E6D114\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:inea:me-rtu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FD7F8299-4A9C-4B93-A35A-68C6D43855CC\"}]}]}],\"references\":[{\"url\":\"https://www.mogozobo.com/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.mogozobo.com/?p=3593\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://www.mogozobo.com/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.mogozobo.com/?p=3593\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}",
   },
}


Log in or create an account to share your comment.

Security Advisory comment format.

This schema specifies the format of a comment related to a security advisory.

UUIDv4 of the comment
UUIDv4 of the Vulnerability-Lookup instance
When the comment was created originally
When the comment was last updated
Title of the comment
Description of the comment
The identifier of the vulnerability (CVE ID, GHSA-ID, PYSEC ID, etc.).



Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.