CVE-2019-14927 (GCVE-0-2019-14927)
Vulnerability from cvelistv5 – Published: 2019-10-28 12:08 – Updated: 2024-09-10 17:10
VLAI?
Summary
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file (which contains data such as usernames, passwords, and other sensitive RTU data).
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T00:34:52.311Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.mogozobo.com/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.mogozobo.com/?p=3593"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU\u0027s configuration file (which contains data such as usernames, passwords, and other sensitive RTU data)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-10T17:10:01.107018",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.mogozobo.com/"
},
{
"url": "https://www.mogozobo.com/?p=3593"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-14927",
"datePublished": "2019-10-28T12:08:22",
"dateReserved": "2019-08-10T00:00:00",
"dateUpdated": "2024-09-10T17:10:01.107018",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:mitsubishielectric:smartrtu_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"2.02\", \"matchCriteriaId\": \"62D6CAA7-11E1-4DF2-A9BD-EC71AE7CD166\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:mitsubishielectric:smartrtu:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1EF90DA0-55C7-4765-9DEE-80145752961D\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:inea:me-rtu_firmware:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"3.0\", \"matchCriteriaId\": \"DDC6C049-B15B-4FC2-9DDF-915381E6D114\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:inea:me-rtu:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"FD7F8299-4A9C-4B93-A35A-68C6D43855CC\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU\u0027s configuration file (which contains data such as usernames, passwords, and other sensitive RTU data).\"}, {\"lang\": \"es\", \"value\": \"Se descubri\\u00f3 un problema en los dispositivos Mitsubishi Electric ME-RTU versiones hasta la versi\\u00f3n 2.02 y los dispositivos INEA ME-RTU versiones hasta la versi\\u00f3n 3.0. Una vulnerabilidad de descarga de configuraci\\u00f3n remota no autenticada permite a un atacante descargar el archivo de configuraci\\u00f3n de smartRTU (que contiene datos como nombres de usuario, contrase\\u00f1as y otros datos confidenciales de RTU).\"}]",
"id": "CVE-2019-14927",
"lastModified": "2024-11-21T04:27:41.993",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:P/I:N/A:N\", \"baseScore\": 5.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2019-10-28T13:15:10.773",
"references": "[{\"url\": \"https://www.mogozobo.com/\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.mogozobo.com/?p=3593\", \"source\": \"cve@mitre.org\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://www.mogozobo.com/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.mogozobo.com/?p=3593\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}]",
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-306\"}, {\"lang\": \"en\", \"value\": \"CWE-425\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2019-14927\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2019-10-28T13:15:10.773\",\"lastModified\":\"2024-11-21T04:27:41.993\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU\u0027s configuration file (which contains data such as usernames, passwords, and other sensitive RTU data).\"},{\"lang\":\"es\",\"value\":\"Se descubri\u00f3 un problema en los dispositivos Mitsubishi Electric ME-RTU versiones hasta la versi\u00f3n 2.02 y los dispositivos INEA ME-RTU versiones hasta la versi\u00f3n 3.0. Una vulnerabilidad de descarga de configuraci\u00f3n remota no autenticada permite a un atacante descargar el archivo de configuraci\u00f3n de smartRTU (que contiene datos como nombres de usuario, contrase\u00f1as y otros datos confidenciales de RTU).\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"},{\"lang\":\"en\",\"value\":\"CWE-425\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:smartrtu_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.02\",\"matchCriteriaId\":\"62D6CAA7-11E1-4DF2-A9BD-EC71AE7CD166\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:smartrtu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1EF90DA0-55C7-4765-9DEE-80145752961D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:inea:me-rtu_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"3.0\",\"matchCriteriaId\":\"DDC6C049-B15B-4FC2-9DDF-915381E6D114\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:inea:me-rtu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FD7F8299-4A9C-4B93-A35A-68C6D43855CC\"}]}]}],\"references\":[{\"url\":\"https://www.mogozobo.com/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.mogozobo.com/?p=3593\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://www.mogozobo.com/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.mogozobo.com/?p=3593\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…