cve-2019-14927
Vulnerability from cvelistv5
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://www.mogozobo.com/ | Third Party Advisory | |
cve@mitre.org | https://www.mogozobo.com/?p=3593 | Exploit, Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.mogozobo.com/ | Third Party Advisory | |
af854a3a-2127-422b-91ae-364da2661108 | https://www.mogozobo.com/?p=3593 | Exploit, Third Party Advisory |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T00:34:52.311Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.mogozobo.com/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.mogozobo.com/?p=3593" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU\u0027s configuration file (which contains data such as usernames, passwords, and other sensitive RTU data)." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2024-09-10T17:10:01.107018", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "url": "https://www.mogozobo.com/" }, { "url": "https://www.mogozobo.com/?p=3593" } ] } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2019-14927", "datePublished": "2019-10-28T12:08:22", "dateReserved": "2019-08-10T00:00:00", "dateUpdated": "2024-09-10T17:10:01.107018", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2019-14927\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2019-10-28T13:15:10.773\",\"lastModified\":\"2024-11-21T04:27:41.993\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU\u0027s configuration file (which contains data such as usernames, passwords, and other sensitive RTU data).\"},{\"lang\":\"es\",\"value\":\"Se descubri\u00f3 un problema en los dispositivos Mitsubishi Electric ME-RTU versiones hasta la versi\u00f3n 2.02 y los dispositivos INEA ME-RTU versiones hasta la versi\u00f3n 3.0. Una vulnerabilidad de descarga de configuraci\u00f3n remota no autenticada permite a un atacante descargar el archivo de configuraci\u00f3n de smartRTU (que contiene datos como nombres de usuario, contrase\u00f1as y otros datos confidenciales de RTU).\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"},{\"lang\":\"en\",\"value\":\"CWE-425\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mitsubishielectric:smartrtu_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.02\",\"matchCriteriaId\":\"62D6CAA7-11E1-4DF2-A9BD-EC71AE7CD166\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mitsubishielectric:smartrtu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1EF90DA0-55C7-4765-9DEE-80145752961D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:inea:me-rtu_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"3.0\",\"matchCriteriaId\":\"DDC6C049-B15B-4FC2-9DDF-915381E6D114\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:inea:me-rtu:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FD7F8299-4A9C-4B93-A35A-68C6D43855CC\"}]}]}],\"references\":[{\"url\":\"https://www.mogozobo.com/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.mogozobo.com/?p=3593\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://www.mogozobo.com/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.mogozobo.com/?p=3593\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}" } }
ICSA-21-252-03
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Mark Cross (@xerubus)" ], "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to gain remote code execution, obtain credentials, and use credentials found to log into other affected devices.", "title": "Risk evaluation" }, { "category": "other", "text": "Critical Manufacturing", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Japan", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-21-252-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-252-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-252-03 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-252-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ncas/tips/ST04-014" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU", "tracking": { "current_release_date": "2021-09-09T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-252-03", "initial_release_date": "2021-09-09T00:00:00.000000Z", "revision_history": [ { "date": "2021-09-09T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-252-03 Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 3.3", "product": { "name": "smartRTU and INEA ME-RTU: all versions prior to Version 3.3", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "smartRTU and INEA ME-RTU" } ], "category": "vendor", "name": "Mitsubishi Electric" } ] }, "vulnerabilities": [ { "cve": "CVE-2019-14931", "cwe": { "id": "CWE-78", "name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "The affected product allows an attacker to execute arbitrary commands due to the passing of unsafe user supplied data to the system shell.CVE-2019-14931 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-14931" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Mitsubishi Electric Europe B.V. recommends users update to firmware Version 3.3 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.inea.si/en/telemetrija-in-m2m-produkti/mertu-en/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2019-14927", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "It is possible to download the affected product \u0027s configuration file, which contains sensitive data, through the URL.CVE-2019-14927 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-14927" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Mitsubishi Electric Europe B.V. recommends users update to firmware Version 3.3 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.inea.si/en/telemetrija-in-m2m-produkti/mertu-en/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2019-14928", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "The affected product \u0027s web configuration software allows an authenticated user to inject malicious data into the application that can then be executed in a victim \u0027s browser, allowing stored cross-site scripting.CVE-2019-14928 has been assigned to this vulnerability. A CVSS v3 base score of 5.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-14928" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Mitsubishi Electric Europe B.V. recommends users update to firmware Version 3.3 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.inea.si/en/telemetrija-in-m2m-produkti/mertu-en/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2019-14926", "cwe": { "id": "CWE-798", "name": "Use of Hard-coded Credentials" }, "notes": [ { "category": "summary", "text": "Hard-coded SSH keys have been identified in the affected product \u0027s firmware. As the secure keys cannot be regenerated by a user and are not regenerated on firmware updates, all deployed affected products utilize the same SSH keys.CVE-2019-14926 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-14926" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Mitsubishi Electric Europe B.V. recommends users update to firmware Version 3.3 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.inea.si/en/telemetrija-in-m2m-produkti/mertu-en/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2019-14930", "cwe": { "id": "CWE-798", "name": "Use of Hard-coded Credentials" }, "notes": [ { "category": "summary", "text": "The affected products contain undocumented user accounts with hard-coded password credentials. An attacker could exploit this vulnerability by using the accounts to login to affected RTU \u0027s.CVE-2019-14930 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-14930" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Mitsubishi Electric Europe B.V. recommends users update to firmware Version 3.3 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.inea.si/en/telemetrija-in-m2m-produkti/mertu-en/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2019-14929", "cwe": { "id": "CWE-256", "name": "Plaintext Storage of a Password" }, "notes": [ { "category": "summary", "text": "The affected products store password credentials in plain text in a configuration file. An unauthenticated user can obtain the exposed password credentials to gain access to the specific services.CVE-2019-14929 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-14929" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Mitsubishi Electric Europe B.V. recommends users update to firmware Version 3.3 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.inea.si/en/telemetrija-in-m2m-produkti/mertu-en/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2019-14925", "cwe": { "id": "CWE-276", "name": "Incorrect Default Permissions" }, "notes": [ { "category": "summary", "text": "The affected products store and reads configuration settings from a file that has insecure world-readable permissions assigned. This could allow all users on the system to read the configuration file containing usernames and plain text password combinations, as well as other sensitive configuration information of the RTU.CVE-2019-14925 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-14925" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Mitsubishi Electric Europe B.V. recommends users update to firmware Version 3.3 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.inea.si/en/telemetrija-in-m2m-produkti/mertu-en/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
icsa-21-252-03
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Mark Cross (@xerubus)" ], "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to gain remote code execution, obtain credentials, and use credentials found to log into other affected devices.", "title": "Risk evaluation" }, { "category": "other", "text": "Critical Manufacturing", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Japan", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also recommends users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-21-252-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-252-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-252-03 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-252-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ncas/tips/ST04-014" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU", "tracking": { "current_release_date": "2021-09-09T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-252-03", "initial_release_date": "2021-09-09T00:00:00.000000Z", "revision_history": [ { "date": "2021-09-09T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-252-03 Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 3.3", "product": { "name": "smartRTU and INEA ME-RTU: all versions prior to Version 3.3", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "smartRTU and INEA ME-RTU" } ], "category": "vendor", "name": "Mitsubishi Electric" } ] }, "vulnerabilities": [ { "cve": "CVE-2019-14931", "cwe": { "id": "CWE-78", "name": "Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)" }, "notes": [ { "category": "summary", "text": "The affected product allows an attacker to execute arbitrary commands due to the passing of unsafe user supplied data to the system shell.CVE-2019-14931 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-14931" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Mitsubishi Electric Europe B.V. recommends users update to firmware Version 3.3 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.inea.si/en/telemetrija-in-m2m-produkti/mertu-en/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2019-14927", "cwe": { "id": "CWE-284", "name": "Improper Access Control" }, "notes": [ { "category": "summary", "text": "It is possible to download the affected product \u0027s configuration file, which contains sensitive data, through the URL.CVE-2019-14927 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-14927" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Mitsubishi Electric Europe B.V. recommends users update to firmware Version 3.3 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.inea.si/en/telemetrija-in-m2m-produkti/mertu-en/" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2019-14928", "cwe": { "id": "CWE-79", "name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)" }, "notes": [ { "category": "summary", "text": "The affected product \u0027s web configuration software allows an authenticated user to inject malicious data into the application that can then be executed in a victim \u0027s browser, allowing stored cross-site scripting.CVE-2019-14928 has been assigned to this vulnerability. A CVSS v3 base score of 5.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-14928" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Mitsubishi Electric Europe B.V. recommends users update to firmware Version 3.3 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.inea.si/en/telemetrija-in-m2m-produkti/mertu-en/" } ], "scores": [ { "cvss_v3": { "baseScore": 5.4, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2019-14926", "cwe": { "id": "CWE-798", "name": "Use of Hard-coded Credentials" }, "notes": [ { "category": "summary", "text": "Hard-coded SSH keys have been identified in the affected product \u0027s firmware. As the secure keys cannot be regenerated by a user and are not regenerated on firmware updates, all deployed affected products utilize the same SSH keys.CVE-2019-14926 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-14926" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Mitsubishi Electric Europe B.V. recommends users update to firmware Version 3.3 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.inea.si/en/telemetrija-in-m2m-produkti/mertu-en/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2019-14930", "cwe": { "id": "CWE-798", "name": "Use of Hard-coded Credentials" }, "notes": [ { "category": "summary", "text": "The affected products contain undocumented user accounts with hard-coded password credentials. An attacker could exploit this vulnerability by using the accounts to login to affected RTU \u0027s.CVE-2019-14930 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-14930" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Mitsubishi Electric Europe B.V. recommends users update to firmware Version 3.3 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.inea.si/en/telemetrija-in-m2m-produkti/mertu-en/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2019-14929", "cwe": { "id": "CWE-256", "name": "Plaintext Storage of a Password" }, "notes": [ { "category": "summary", "text": "The affected products store password credentials in plain text in a configuration file. An unauthenticated user can obtain the exposed password credentials to gain access to the specific services.CVE-2019-14929 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-14929" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Mitsubishi Electric Europe B.V. recommends users update to firmware Version 3.3 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.inea.si/en/telemetrija-in-m2m-produkti/mertu-en/" } ], "scores": [ { "cvss_v3": { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2019-14925", "cwe": { "id": "CWE-276", "name": "Incorrect Default Permissions" }, "notes": [ { "category": "summary", "text": "The affected products store and reads configuration settings from a file that has insecure world-readable permissions assigned. This could allow all users on the system to read the configuration file containing usernames and plain text password combinations, as well as other sensitive configuration information of the RTU.CVE-2019-14925 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2019-14925" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Mitsubishi Electric Europe B.V. recommends users update to firmware Version 3.3 or later.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.inea.si/en/telemetrija-in-m2m-produkti/mertu-en/" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
var-201910-0805
Vulnerability from variot
An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file (which contains data such as usernames, passwords, and other sensitive RTU data). Inea ME-RTU is an intelligent communication gateway product of Inea Company in Slovenia.
There are security vulnerabilities in Mitsubishi Electric smartRTU 2.02 and earlier versions and INEA ME-RTU 3.0 and earlier versions
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201910-0805", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "me-rtu", "scope": "lte", "trust": 1.0, "vendor": "inea", "version": "3.0" }, { "model": "smartrtu", "scope": "lte", "trust": 1.0, "vendor": "mitsubishielectric", "version": "2.02" }, { "model": "me-rtu", "scope": null, "trust": 0.8, "vendor": "inea d o o", "version": null }, { "model": "smartrtu", "scope": null, "trust": 0.8, "vendor": "\u4e09\u83f1\u96fb\u6a5f", "version": null }, { "model": "electric inea me-rtu", "scope": "lte", "trust": 0.6, "vendor": "mitsubishi", "version": "\u003c=3.0" }, { "model": "electric smartrtu", "scope": "lte", "trust": 0.6, "vendor": "mitsubishi", "version": "\u003c=2.02" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-43689" }, { "db": "JVNDB", "id": "JVNDB-2019-011339" }, { "db": "NVD", "id": "CVE-2019-14927" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:mitsubishielectric:smartrtu_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "2.02", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:mitsubishielectric:smartrtu:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:inea:me-rtu_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "3.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:inea:me-rtu:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2019-14927" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Mark Cross (@xerubus) reported these vulnerabilities to CISA.", "sources": [ { "db": "CNNVD", "id": "CNNVD-201910-1532" } ], "trust": 0.6 }, "cve": "CVE-2019-14927", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "impactScore": 2.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 5.0, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2019-14927", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 10.0, "id": "CNVD-2020-43689", "impactScore": 2.9, "integrityImpact": "NONE", "severity": "MEDIUM", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 3.9, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2019-14927", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2019-14927", "trust": 1.8, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2020-43689", "trust": 0.6, "value": "MEDIUM" }, { "author": "CNNVD", "id": "CNNVD-201910-1532", "trust": 0.6, "value": "HIGH" }, { "author": "VULMON", "id": "CVE-2019-14927", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-43689" }, { "db": "VULMON", "id": "CVE-2019-14927" }, { "db": "JVNDB", "id": "JVNDB-2019-011339" }, { "db": "NVD", "id": "CVE-2019-14927" }, { "db": "CNNVD", "id": "CNNVD-201910-1532" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU\u0027s configuration file (which contains data such as usernames, passwords, and other sensitive RTU data). Inea ME-RTU is an intelligent communication gateway product of Inea Company in Slovenia. \n\r\n\r\nThere are security vulnerabilities in Mitsubishi Electric smartRTU 2.02 and earlier versions and INEA ME-RTU 3.0 and earlier versions", "sources": [ { "db": "NVD", "id": "CVE-2019-14927" }, { "db": "JVNDB", "id": "JVNDB-2019-011339" }, { "db": "CNVD", "id": "CNVD-2020-43689" }, { "db": "VULMON", "id": "CVE-2019-14927" } ], "trust": 2.25 }, "exploit_availability": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "reference": "https://vulmon.com/exploitdetails?qidtp=exploitdb\u0026qid=47234", "trust": 0.1, "type": "exploit" } ], "sources": [ { "db": "VULMON", "id": "CVE-2019-14927" } ] }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2019-14927", "trust": 3.1 }, { "db": "ICS CERT", "id": "ICSA-21-252-03", "trust": 1.4 }, { "db": "JVN", "id": "JVNVU93054759", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2019-011339", "trust": 0.8 }, { "db": "CNVD", "id": "CNVD-2020-43689", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.3043", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-201910-1532", "trust": 0.6 }, { "db": "EXPLOIT-DB", "id": "47234", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2019-14927", "trust": 0.1 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-43689" }, { "db": "VULMON", "id": "CVE-2019-14927" }, { "db": "JVNDB", "id": "JVNDB-2019-011339" }, { "db": "NVD", "id": "CVE-2019-14927" }, { "db": "CNNVD", "id": "CNNVD-201910-1532" } ] }, "id": "VAR-201910-0805", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2020-43689" } ], "trust": 1.4627451 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-43689" } ] }, "last_update_date": "2023-12-18T12:50:01.416000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "ME\u00a0RTU Mitsubishi Electric MITSUBISHI\u00a0ELECTRIC\u00a0AUTOMATION", "trust": 0.8, "url": "http://www.inea.si/en/telemetrija-in-m2m-produkti/mertu-en/" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-011339" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-306", "trust": 1.0 }, { "problemtype": "CWE-425", "trust": 1.0 }, { "problemtype": "information leak (CWE-200) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-011339" }, { "db": "NVD", "id": "CVE-2019-14927" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.5, "url": "https://www.mogozobo.com/?p=3593" }, { "trust": 2.0, "url": "https://nvd.nist.gov/vuln/detail/cve-2019-14927" }, { "trust": 1.7, "url": "https://www.mogozobo.com/" }, { "trust": 1.4, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-252-03" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu93054759/" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.3043" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/306.html" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/425.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" }, { "trust": 0.1, "url": "https://www.exploit-db.com/exploits/47234" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2020-43689" }, { "db": "VULMON", "id": "CVE-2019-14927" }, { "db": "JVNDB", "id": "JVNDB-2019-011339" }, { "db": "NVD", "id": "CVE-2019-14927" }, { "db": "CNNVD", "id": "CNNVD-201910-1532" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "CNVD", "id": "CNVD-2020-43689" }, { "db": "VULMON", "id": "CVE-2019-14927" }, { "db": "JVNDB", "id": "JVNDB-2019-011339" }, { "db": "NVD", "id": "CVE-2019-14927" }, { "db": "CNNVD", "id": "CNNVD-201910-1532" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-08-01T00:00:00", "db": "CNVD", "id": "CNVD-2020-43689" }, { "date": "2019-10-28T00:00:00", "db": "VULMON", "id": "CVE-2019-14927" }, { "date": "2019-11-05T00:00:00", "db": "JVNDB", "id": "JVNDB-2019-011339" }, { "date": "2019-10-28T13:15:10.773000", "db": "NVD", "id": "CVE-2019-14927" }, { "date": "2019-10-28T00:00:00", "db": "CNNVD", "id": "CNNVD-201910-1532" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2020-08-01T00:00:00", "db": "CNVD", "id": "CNVD-2020-43689" }, { "date": "2021-07-21T00:00:00", "db": "VULMON", "id": "CVE-2019-14927" }, { "date": "2021-09-14T05:49:00", "db": "JVNDB", "id": "JVNDB-2019-011339" }, { "date": "2021-07-21T11:39:23.747000", "db": "NVD", "id": "CVE-2019-14927" }, { "date": "2021-09-10T00:00:00", "db": "CNNVD", "id": "CNNVD-201910-1532" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201910-1532" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Mitsubishi\u00a0Electric\u00a0ME-RTU\u00a0 Device and \u00a0INEA\u00a0ME-RTU\u00a0 Information leakage vulnerabilities in devices", "sources": [ { "db": "JVNDB", "id": "JVNDB-2019-011339" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "information disclosure", "sources": [ { "db": "CNNVD", "id": "CNNVD-201910-1532" } ], "trust": 0.6 } }
ghsa-xp5g-v8fx-97mv
Vulnerability from github
An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file (which contains data such as usernames, passwords, and other sensitive RTU data).
{ "affected": [], "aliases": [ "CVE-2019-14927" ], "database_specific": { "cwe_ids": [ "CWE-200", "CWE-306" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2019-10-28T13:15:00Z", "severity": "HIGH" }, "details": "An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU\u0027s configuration file (which contains data such as usernames, passwords, and other sensitive RTU data).", "id": "GHSA-xp5g-v8fx-97mv", "modified": "2024-09-10T18:30:40Z", "published": "2022-05-24T16:59:57Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2019-14927" }, { "type": "WEB", "url": "https://www.mogozobo.com" }, { "type": "WEB", "url": "https://www.mogozobo.com/?p=3593" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "type": "CVSS_V3" } ] }
gsd-2019-14927
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2019-14927", "description": "An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU\u0027s configuration file (which contains data such as usernames, passwords, and other sensitive RTU data).", "id": "GSD-2019-14927" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2019-14927" ], "details": "An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU\u0027s configuration file (which contains data such as usernames, passwords, and other sensitive RTU data).", "id": "GSD-2019-14927", "modified": "2023-12-13T01:23:53.386253Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-14927", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU\u0027s configuration file (which contains data such as usernames, passwords, and other sensitive RTU data)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.mogozobo.com/", "refsource": "MISC", "url": "https://www.mogozobo.com/" }, { "name": "https://www.mogozobo.com/?p=3593", "refsource": "MISC", "url": "https://www.mogozobo.com/?p=3593" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:mitsubishielectric:smartrtu_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "2.02", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:mitsubishielectric:smartrtu:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:inea:me-rtu_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "3.0", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:inea:me-rtu:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2019-14927" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "An issue was discovered on Mitsubishi Electric ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU\u0027s configuration file (which contains data such as usernames, passwords, and other sensitive RTU data)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-306" }, { "lang": "en", "value": "CWE-425" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.mogozobo.com/", "refsource": "MISC", "tags": [ "Third Party Advisory" ], "url": "https://www.mogozobo.com/" }, { "name": "https://www.mogozobo.com/?p=3593", "refsource": "MISC", "tags": [ "Exploit", "Third Party Advisory" ], "url": "https://www.mogozobo.com/?p=3593" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 5.0, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 10.0, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.6 } }, "lastModifiedDate": "2021-07-21T11:39Z", "publishedDate": "2019-10-28T13:15Z" } } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.