CVE-2019-16514 (GCVE-0-2019-16514)
Vulnerability from cvelistv5 – Published: 2020-01-23 17:21 – Updated: 2024-08-05 01:17
VLAI?
Summary
An issue was discovered in ConnectWise Control (formerly known as ScreenConnect) 19.3.25270.7185. The server allows remote code execution. Administrative users could upload an unsigned extension ZIP file containing executable code that is subsequently executed by the server.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T01:17:40.108Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://know.bishopfox.com/advisories"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://know.bishopfox.com/advisories/connectwise-control"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://blog.huntresslabs.com/validating-the-bishop-fox-findings-in-connectwise-control-9155eec36a34"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.crn.com/news/managed-services/connectwise-control-msp-security-vulnerabilities-are-severe-bishop-fox"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.crn.com/slide-shows/managed-services/connectwise-control-attack-chain-exploit-20-questions-for-security-researcher-bishop-fox"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in ConnectWise Control (formerly known as ScreenConnect) 19.3.25270.7185. The server allows remote code execution. Administrative users could upload an unsigned extension ZIP file containing executable code that is subsequently executed by the server."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-23T17:21:38",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://know.bishopfox.com/advisories"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://know.bishopfox.com/advisories/connectwise-control"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://blog.huntresslabs.com/validating-the-bishop-fox-findings-in-connectwise-control-9155eec36a34"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.crn.com/news/managed-services/connectwise-control-msp-security-vulnerabilities-are-severe-bishop-fox"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.crn.com/slide-shows/managed-services/connectwise-control-attack-chain-exploit-20-questions-for-security-researcher-bishop-fox"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-16514",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in ConnectWise Control (formerly known as ScreenConnect) 19.3.25270.7185. The server allows remote code execution. Administrative users could upload an unsigned extension ZIP file containing executable code that is subsequently executed by the server."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://know.bishopfox.com/advisories",
"refsource": "MISC",
"url": "https://know.bishopfox.com/advisories"
},
{
"name": "https://know.bishopfox.com/advisories/connectwise-control",
"refsource": "MISC",
"url": "https://know.bishopfox.com/advisories/connectwise-control"
},
{
"name": "https://blog.huntresslabs.com/validating-the-bishop-fox-findings-in-connectwise-control-9155eec36a34",
"refsource": "MISC",
"url": "https://blog.huntresslabs.com/validating-the-bishop-fox-findings-in-connectwise-control-9155eec36a34"
},
{
"name": "https://www.crn.com/news/managed-services/connectwise-control-msp-security-vulnerabilities-are-severe-bishop-fox",
"refsource": "MISC",
"url": "https://www.crn.com/news/managed-services/connectwise-control-msp-security-vulnerabilities-are-severe-bishop-fox"
},
{
"name": "https://www.crn.com/slide-shows/managed-services/connectwise-control-attack-chain-exploit-20-questions-for-security-researcher-bishop-fox",
"refsource": "MISC",
"url": "https://www.crn.com/slide-shows/managed-services/connectwise-control-attack-chain-exploit-20-questions-for-security-researcher-bishop-fox"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-16514",
"datePublished": "2020-01-23T17:21:38",
"dateReserved": "2019-09-19T00:00:00",
"dateUpdated": "2024-08-05T01:17:40.108Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:connectwise:control:19.3.25270.7185:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9261503D-CC12-4EED-9993-015DEE22FB89\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"An issue was discovered in ConnectWise Control (formerly known as ScreenConnect) 19.3.25270.7185. The server allows remote code execution. Administrative users could upload an unsigned extension ZIP file containing executable code that is subsequently executed by the server.\"}, {\"lang\": \"es\", \"value\": \"Se detect\\u00f3 un problema en ConnectWise Control (anteriormente se conoce como ScreenConnect) versi\\u00f3n 19.3.25270.7185. El servidor permite una ejecuci\\u00f3n de c\\u00f3digo remota. Los usuarios administrativos podr\\u00edan cargar un archivo de extensi\\u00f3n ZIP sin firma que contiene c\\u00f3digo ejecutable que posteriormente es ejecutado por parte del servidor.\"}]",
"id": "CVE-2019-16514",
"lastModified": "2024-11-21T04:30:44.333",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.2, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.2, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:S/C:P/I:P/A:P\", \"baseScore\": 6.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.0, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2020-01-23T18:15:13.523",
"references": "[{\"url\": \"https://blog.huntresslabs.com/validating-the-bishop-fox-findings-in-connectwise-control-9155eec36a34\", \"source\": \"cve@mitre.org\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://know.bishopfox.com/advisories\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://know.bishopfox.com/advisories/connectwise-control\", \"source\": \"cve@mitre.org\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://www.crn.com/news/managed-services/connectwise-control-msp-security-vulnerabilities-are-severe-bishop-fox\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.crn.com/slide-shows/managed-services/connectwise-control-attack-chain-exploit-20-questions-for-security-researcher-bishop-fox\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://blog.huntresslabs.com/validating-the-bishop-fox-findings-in-connectwise-control-9155eec36a34\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://know.bishopfox.com/advisories\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://know.bishopfox.com/advisories/connectwise-control\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://www.crn.com/news/managed-services/connectwise-control-msp-security-vulnerabilities-are-severe-bishop-fox\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.crn.com/slide-shows/managed-services/connectwise-control-attack-chain-exploit-20-questions-for-security-researcher-bishop-fox\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}]",
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-434\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2019-16514\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2020-01-23T18:15:13.523\",\"lastModified\":\"2024-11-21T04:30:44.333\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"An issue was discovered in ConnectWise Control (formerly known as ScreenConnect) 19.3.25270.7185. The server allows remote code execution. Administrative users could upload an unsigned extension ZIP file containing executable code that is subsequently executed by the server.\"},{\"lang\":\"es\",\"value\":\"Se detect\u00f3 un problema en ConnectWise Control (anteriormente se conoce como ScreenConnect) versi\u00f3n 19.3.25270.7185. El servidor permite una ejecuci\u00f3n de c\u00f3digo remota. Los usuarios administrativos podr\u00edan cargar un archivo de extensi\u00f3n ZIP sin firma que contiene c\u00f3digo ejecutable que posteriormente es ejecutado por parte del servidor.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.2,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-434\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:connectwise:control:19.3.25270.7185:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9261503D-CC12-4EED-9993-015DEE22FB89\"}]}]}],\"references\":[{\"url\":\"https://blog.huntresslabs.com/validating-the-bishop-fox-findings-in-connectwise-control-9155eec36a34\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://know.bishopfox.com/advisories\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://know.bishopfox.com/advisories/connectwise-control\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://www.crn.com/news/managed-services/connectwise-control-msp-security-vulnerabilities-are-severe-bishop-fox\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.crn.com/slide-shows/managed-services/connectwise-control-attack-chain-exploit-20-questions-for-security-researcher-bishop-fox\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://blog.huntresslabs.com/validating-the-bishop-fox-findings-in-connectwise-control-9155eec36a34\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://know.bishopfox.com/advisories\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://know.bishopfox.com/advisories/connectwise-control\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://www.crn.com/news/managed-services/connectwise-control-msp-security-vulnerabilities-are-severe-bishop-fox\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.crn.com/slide-shows/managed-services/connectwise-control-attack-chain-exploit-20-questions-for-security-researcher-bishop-fox\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…