cve-2019-19276
Vulnerability from cvelistv5
Published
2021-05-12 13:18
Modified
2024-08-05 02:09
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service.
References
▼ | URL | Tags | |
---|---|---|---|
productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf | Patch, Vendor Advisory |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-05T02:09:39.475Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants)", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] }, { "product": "SIMATIC HMI KTP Mobile Panels", "vendor": "Siemens", "versions": [ { "status": "affected", "version": "All versions \u003c V16 Update 4" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service." } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787: Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-05-12T13:18:21", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2019-19276", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants)", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } }, { "product_name": "SIMATIC HMI KTP Mobile Panels", "version": { "version_data": [ { "version_value": "All versions \u003c V16 Update 4" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-787: Out-of-bounds Write" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2019-19276", "datePublished": "2021-05-12T13:18:21", "dateReserved": "2019-11-26T00:00:00", "dateUpdated": "2024-08-05T02:09:39.475Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2019-19276\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-05-12T14:15:10.543\",\"lastModified\":\"2021-06-02T18:18:33.440\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC HMI Comfort Panels 1st Generation (incl. SIPLUS variants) (All versions \u003c V16 Update 4), SIMATIC HMI KTP Mobile Panels (All versions \u003c V16 Update 4). Specially crafted packets sent to port 161/udp can cause the SNMP service of affected devices to crash. A manual restart of the device is required to resume operation of the service.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SIMATIC HMI Comfort Panels 1st Generation (incluyendo variantes SIPLUS) (Todas las versiones anteriores a V16 Update 4), SIMATIC HMI KTP Mobile Panels (Todas las versiones anteriores a V16 Update 4). Los paquetes especialmente dise\u00f1ados enviados al puerto 161/udp pueden hacer que el servicio SNMP de los dispositivos afectados se bloquee. Se requiere un reinicio manual del dispositivo para reanudar el funcionamiento del servicio\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":5.0},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"C1470479-8A5B-4A72-8B3C-A8311F787F81\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16:update_2:*:*:*:*:*:*\",\"matchCriteriaId\":\"85144667-DFAD-459A-84BE-E842CBC941ED\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_ktp_mobile_panels_firmware:16:update_3:*:*:*:*:*:*\",\"matchCriteriaId\":\"8A7EA7D4-1505-48CE-BCAC-15D65F199529\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_ktp_mobile_panels:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B1CEB200-E38F-4629-9279-5AF065396678\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"3CFD6C34-08A0-4653-A5DD-8CD4F43EF246\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16:update_2:*:*:*:*:*:*\",\"matchCriteriaId\":\"6FECA798-00DC-4182-AEA4-E06F9C697755\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_hmi_comfort_panels_firmware:16:update_3:*:*:*:*:*:*\",\"matchCriteriaId\":\"77C80EA7-5B3F-42FE-9BF0-8B01674BA168\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_hmi_comfort_panels:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3BCFE761-35C9-43EF-85BC-E8083B9F75CB\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-594364.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.