CVE-2019-9583 (GCVE-0-2019-9583)

Vulnerability from cvelistv5 – Published: 2019-08-14 19:47 – Updated: 2024-08-04 21:54
VLAI?
Summary
eQ-3 Homematic CCU2 and CCU3 obtain session IDs without login. This allows a Denial of Service and is a starting point for other attacks. Affected versions for CCU2: 2.35.16, 2.41.5, 2.41.8, 2.41.9, 2.45.6, 2.45.7, 2.47.10, 2.47.12, 2.47.15. Affected versions for CCU3: 3.41.11, 3.43.16, 3.45.5, 3.45.7, 3.47.10, 3.47.15.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T21:54:44.498Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://github.com/psytester/psytester.github.io/blob/master/_posts/hacking_and_pentests/CVEs/2019-03-27-CVE-2019-9583.md"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://psytester.github.io/CVE-2019-9583/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "eQ-3 Homematic CCU2 and CCU3 obtain session IDs without login. This allows a Denial of Service and is a starting point for other attacks. Affected versions for CCU2: 2.35.16, 2.41.5, 2.41.8, 2.41.9, 2.45.6, 2.45.7, 2.47.10, 2.47.12, 2.47.15. Affected versions for CCU3: 3.41.11, 3.43.16, 3.45.5, 3.45.7, 3.47.10, 3.47.15."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-08-14T19:47:54",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/psytester/psytester.github.io/blob/master/_posts/hacking_and_pentests/CVEs/2019-03-27-CVE-2019-9583.md"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://psytester.github.io/CVE-2019-9583/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2019-9583",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "eQ-3 Homematic CCU2 and CCU3 obtain session IDs without login. This allows a Denial of Service and is a starting point for other attacks. Affected versions for CCU2: 2.35.16, 2.41.5, 2.41.8, 2.41.9, 2.45.6, 2.45.7, 2.47.10, 2.47.12, 2.47.15. Affected versions for CCU3: 3.41.11, 3.43.16, 3.45.5, 3.45.7, 3.47.10, 3.47.15."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://github.com/psytester/psytester.github.io/blob/master/_posts/hacking_and_pentests/CVEs/2019-03-27-CVE-2019-9583.md",
              "refsource": "MISC",
              "url": "https://github.com/psytester/psytester.github.io/blob/master/_posts/hacking_and_pentests/CVEs/2019-03-27-CVE-2019-9583.md"
            },
            {
              "name": "https://psytester.github.io/CVE-2019-9583/",
              "refsource": "MISC",
              "url": "https://psytester.github.io/CVE-2019-9583/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2019-9583",
    "datePublished": "2019-08-14T19:47:54",
    "dateReserved": "2019-03-06T00:00:00",
    "dateUpdated": "2024-08-04T21:54:44.498Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:eq-3:homematic_ccu3_firmware:3.41.11:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F63AD6F8-1BE7-481B-BDDE-45234840B530\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:eq-3:homematic_ccu3_firmware:3.43.16:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"ED2A0030-E46B-42EE-B545-1D04D46F3FB5\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:eq-3:homematic_ccu3_firmware:3.45.5:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E2C1A46E-178C-4893-A172-6D081D9BAA67\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:eq-3:homematic_ccu3_firmware:3.45.7:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"75BE927B-CD17-4293-A440-8DD29C8CD23E\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:eq-3:homematic_ccu3_firmware:3.47.10:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D4E76C1E-A745-4BEA-B3B2-2B613DA4FCC5\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:eq-3:homematic_ccu3_firmware:3.47.15:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"96CA7522-DB7E-4F61-BD85-A8F665AFC697\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:eq-3:homematic_ccu3:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"33113AD0-F378-49B2-BCFC-C57B52FD3A04\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:eq-3:homematic_ccu2_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"AC8E6D04-7E53-4471-A20F-66C974B5B751\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:eq-3:homematic_ccu2_firmware:2.35.16:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2313AB9D-E18F-4603-8CE5-D0C3D9660785\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:eq-3:homematic_ccu2_firmware:2.41.5:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CFE9F1F1-70FB-470C-8455-201797CA50D5\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:eq-3:homematic_ccu2_firmware:2.41.8:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1CE5BE83-688F-4188-844F-328C846D90C2\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:eq-3:homematic_ccu2_firmware:2.41.9:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"592EDF0E-792F-4DEC-9926-E33675C5C7C9\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:eq-3:homematic_ccu2_firmware:2.45.6:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"38DF6345-9A75-4E5C-9BEC-CB6A0767E739\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:eq-3:homematic_ccu2_firmware:2.45.7:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C1FA10A6-D09E-44EC-ABEB-49CFA8780456\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:eq-3:homematic_ccu2_firmware:2.47.10:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E02A84D1-C6F6-4DE0-88A3-85F41A90D9EB\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:eq-3:homematic_ccu2_firmware:2.47.12:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"84030C3C-ED0D-4CB5-863C-F5663AE4AFE1\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:eq-3:homematic_ccu2_firmware:2.47.15:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F03E1DE6-70FF-4EE9-A3E2-44020B64ADDB\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:eq-3:homematic_ccu2:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9C2CF19C-7EDE-4E3C-A736-E6736FF03FDC\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"eQ-3 Homematic CCU2 and CCU3 obtain session IDs without login. This allows a Denial of Service and is a starting point for other attacks. Affected versions for CCU2: 2.35.16, 2.41.5, 2.41.8, 2.41.9, 2.45.6, 2.45.7, 2.47.10, 2.47.12, 2.47.15. Affected versions for CCU3: 3.41.11, 3.43.16, 3.45.5, 3.45.7, 3.47.10, 3.47.15.\"}, {\"lang\": \"es\", \"value\": \"eQ-3 Homematic CCU2 y CCU3 obtienen los IDs de sesi\\u00f3n sin iniciar sesi\\u00f3n. Esto permite una denegaci\\u00f3n de servicio y es un punto de partida para otros ataques. Versiones afectadas para CCU2: 2.35.16, 2.41.5, 2.41.8, 2.41.9, 2.45.6, 2.45.7, 2.47.10, 2.47.12, 2.47.15. Versiones afectadas para CCU3: 3.41.11, 3.43.16, 3.45.5, 3.45.7, 3.47.10, 3.47.15.\"}]",
      "id": "CVE-2019-9583",
      "lastModified": "2024-11-21T04:51:54.180",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H\", \"baseScore\": 8.2, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 4.2}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:N/I:P/A:P\", \"baseScore\": 6.4, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 4.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2019-08-14T20:15:11.790",
      "references": "[{\"url\": \"https://github.com/psytester/psytester.github.io/blob/master/_posts/hacking_and_pentests/CVEs/2019-03-27-CVE-2019-9583.md\", \"source\": \"cve@mitre.org\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://psytester.github.io/CVE-2019-9583/\", \"source\": \"cve@mitre.org\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://github.com/psytester/psytester.github.io/blob/master/_posts/hacking_and_pentests/CVEs/2019-03-27-CVE-2019-9583.md\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://psytester.github.io/CVE-2019-9583/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}]",
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-400\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2019-9583\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2019-08-14T20:15:11.790\",\"lastModified\":\"2024-11-21T04:51:54.180\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"eQ-3 Homematic CCU2 and CCU3 obtain session IDs without login. This allows a Denial of Service and is a starting point for other attacks. Affected versions for CCU2: 2.35.16, 2.41.5, 2.41.8, 2.41.9, 2.45.6, 2.45.7, 2.47.10, 2.47.12, 2.47.15. Affected versions for CCU3: 3.41.11, 3.43.16, 3.45.5, 3.45.7, 3.47.10, 3.47.15.\"},{\"lang\":\"es\",\"value\":\"eQ-3 Homematic CCU2 y CCU3 obtienen los IDs de sesi\u00f3n sin iniciar sesi\u00f3n. Esto permite una denegaci\u00f3n de servicio y es un punto de partida para otros ataques. Versiones afectadas para CCU2: 2.35.16, 2.41.5, 2.41.8, 2.41.9, 2.45.6, 2.45.7, 2.47.10, 2.47.12, 2.47.15. Versiones afectadas para CCU3: 3.41.11, 3.43.16, 3.45.5, 3.45.7, 3.47.10, 3.47.15.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H\",\"baseScore\":8.2,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":4.2}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:P/A:P\",\"baseScore\":6.4,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":4.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-400\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:eq-3:homematic_ccu3_firmware:3.41.11:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F63AD6F8-1BE7-481B-BDDE-45234840B530\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:eq-3:homematic_ccu3_firmware:3.43.16:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"ED2A0030-E46B-42EE-B545-1D04D46F3FB5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:eq-3:homematic_ccu3_firmware:3.45.5:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E2C1A46E-178C-4893-A172-6D081D9BAA67\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:eq-3:homematic_ccu3_firmware:3.45.7:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"75BE927B-CD17-4293-A440-8DD29C8CD23E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:eq-3:homematic_ccu3_firmware:3.47.10:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D4E76C1E-A745-4BEA-B3B2-2B613DA4FCC5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:eq-3:homematic_ccu3_firmware:3.47.15:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"96CA7522-DB7E-4F61-BD85-A8F665AFC697\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:eq-3:homematic_ccu3:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"33113AD0-F378-49B2-BCFC-C57B52FD3A04\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:eq-3:homematic_ccu2_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"AC8E6D04-7E53-4471-A20F-66C974B5B751\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:eq-3:homematic_ccu2_firmware:2.35.16:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2313AB9D-E18F-4603-8CE5-D0C3D9660785\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:eq-3:homematic_ccu2_firmware:2.41.5:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CFE9F1F1-70FB-470C-8455-201797CA50D5\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:eq-3:homematic_ccu2_firmware:2.41.8:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1CE5BE83-688F-4188-844F-328C846D90C2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:eq-3:homematic_ccu2_firmware:2.41.9:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"592EDF0E-792F-4DEC-9926-E33675C5C7C9\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:eq-3:homematic_ccu2_firmware:2.45.6:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"38DF6345-9A75-4E5C-9BEC-CB6A0767E739\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:eq-3:homematic_ccu2_firmware:2.45.7:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C1FA10A6-D09E-44EC-ABEB-49CFA8780456\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:eq-3:homematic_ccu2_firmware:2.47.10:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E02A84D1-C6F6-4DE0-88A3-85F41A90D9EB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:eq-3:homematic_ccu2_firmware:2.47.12:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"84030C3C-ED0D-4CB5-863C-F5663AE4AFE1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:eq-3:homematic_ccu2_firmware:2.47.15:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F03E1DE6-70FF-4EE9-A3E2-44020B64ADDB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:eq-3:homematic_ccu2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9C2CF19C-7EDE-4E3C-A736-E6736FF03FDC\"}]}]}],\"references\":[{\"url\":\"https://github.com/psytester/psytester.github.io/blob/master/_posts/hacking_and_pentests/CVEs/2019-03-27-CVE-2019-9583.md\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://psytester.github.io/CVE-2019-9583/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://github.com/psytester/psytester.github.io/blob/master/_posts/hacking_and_pentests/CVEs/2019-03-27-CVE-2019-9583.md\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://psytester.github.io/CVE-2019-9583/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…