cve-2020-10270
Vulnerability from cvelistv5
Published
2020-06-24 04:50
Modified
2024-09-17 02:56
Severity ?
EPSS score ?
Summary
RVD#2557: Hardcoded Credentials on MiRX00 Control Dashboard
References
▼ | URL | Tags | |
---|---|---|---|
cve@aliasrobotics.com | https://github.com/aliasrobotics/RVD/issues/2557 | Exploit, Third Party Advisory |
Impacted products
▼ | Vendor | Product |
---|---|---|
Mobile Industrial Robots A/S | MiR100 |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T10:58:40.241Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://github.com/aliasrobotics/RVD/issues/2557" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "MiR100", "vendor": "Mobile Industrial Robots A/S", "versions": [ { "status": "affected", "version": "v2.8.1.1 and before" } ] } ], "credits": [ { "lang": "en", "value": "Alias Robotics (https://aliasrobotics.com/)" } ], "datePublic": "2020-06-24T00:00:00", "descriptions": [ { "lang": "en", "value": "Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it\u0027s possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface default to well known and widely spread users (omitted) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. This flaw allows cyber attackers to take control of the robot remotely and make use of the default user interfaces MiR has created, lowering the complexity of attacks and making them available to entry-level attackers. More elaborated attacks can also be established by clearing authentication and sending network requests directly. We have confirmed this flaw in MiR100 and MiR200 but according to the vendor, it might also apply to MiR250, MiR500 and MiR1000." } ], "metrics": [ { "cvssV3_0": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-798", "description": "CWE-798", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-06-24T04:50:18", "orgId": "dc524f69-879d-41dc-ab8f-724e78658a1a", "shortName": "Alias" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://github.com/aliasrobotics/RVD/issues/2557" } ], "source": { "defect": [ "RVD#2557" ], "discovery": "EXTERNAL" }, "title": "RVD#2557: Hardcoded Credentials on MiRX00 Control Dashboard", "x_generator": { "engine": "Robot Vulnerability Database (RVD)" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@aliasrobotics.com", "DATE_PUBLIC": "2020-06-24T04:43:52 +00:00", "ID": "CVE-2020-10270", "STATE": "PUBLIC", "TITLE": "RVD#2557: Hardcoded Credentials on MiRX00 Control Dashboard" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "MiR100", "version": { "version_data": [ { "version_value": "v2.8.1.1 and before" } ] } } ] }, "vendor_name": "Mobile Industrial Robots A/S" } ] } }, "credit": [ { "lang": "eng", "value": "Alias Robotics (https://aliasrobotics.com/)" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it\u0027s possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface default to well known and widely spread users (omitted) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. This flaw allows cyber attackers to take control of the robot remotely and make use of the default user interfaces MiR has created, lowering the complexity of attacks and making them available to entry-level attackers. More elaborated attacks can also be established by clearing authentication and sending network requests directly. We have confirmed this flaw in MiR100 and MiR200 but according to the vendor, it might also apply to MiR250, MiR500 and MiR1000." } ] }, "generator": { "engine": "Robot Vulnerability Database (RVD)" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "critical", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-798" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/aliasrobotics/RVD/issues/2557", "refsource": "CONFIRM", "url": "https://github.com/aliasrobotics/RVD/issues/2557" } ] }, "source": { "defect": [ "RVD#2557" ], "discovery": "EXTERNAL" } } } }, "cveMetadata": { "assignerOrgId": "dc524f69-879d-41dc-ab8f-724e78658a1a", "assignerShortName": "Alias", "cveId": "CVE-2020-10270", "datePublished": "2020-06-24T04:50:18.383490Z", "dateReserved": "2020-03-10T00:00:00", "dateUpdated": "2024-09-17T02:56:46.149Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-10270\",\"sourceIdentifier\":\"cve@aliasrobotics.com\",\"published\":\"2020-06-24T05:15:12.753\",\"lastModified\":\"2020-07-06T15:49:11.387\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it\u0027s possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface default to well known and widely spread users (omitted) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. This flaw allows cyber attackers to take control of the robot remotely and make use of the default user interfaces MiR has created, lowering the complexity of attacks and making them available to entry-level attackers. More elaborated attacks can also be established by clearing authentication and sending network requests directly. We have confirmed this flaw in MiR100 and MiR200 but according to the vendor, it might also apply to MiR250, MiR500 and MiR1000.\"},{\"lang\":\"es\",\"value\":\"Fuera de las interfaces cableadas e inal\u00e1mbricas dentro de MiR100, MiR200 y otros veh\u00edculos de MiR fleet, es posible acceder al Panel de Control en una direcci\u00f3n IP embebida. Las credenciales de dicha interfaz inal\u00e1mbrica son predeterminadas para usuarios conocidos y ampliamente difundidos (omitidos) y contrase\u00f1as (omitidas). Esta informaci\u00f3n tambi\u00e9n est\u00e1 disponible en gu\u00edas de usuario y manuales anteriores que el proveedor distribuy\u00f3. Este fallo permite a atacantes cibern\u00e9ticos tomar el control del robot remotamente y hacer uso de las interfaces de usuario predeterminadas que MiR ha creado, reduciendo la complejidad de los ataques y poni\u00e9ndolos a disposici\u00f3n de los atacantes a nivel de entrada. Tambi\u00e9n se pueden establecer ataques m\u00e1s elaborados al borrar la autenticaci\u00f3n y enviar peticiones de red directamente. Hemos confirmado este fallo en MiR100 y MiR200, pero seg\u00fan el proveedor, tambi\u00e9n podr\u00eda aplicarse a MiR250, MiR500 y MiR1000\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV30\":[{\"source\":\"cve@aliasrobotics.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":5.0},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-798\"}]},{\"source\":\"cve@aliasrobotics.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-798\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:aliasrobotics:mir100_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.8.1.1\",\"matchCriteriaId\":\"BBDEDA2D-26AB-4F23-B672-D0C89A7BEFB9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:aliasrobotics:mir100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D0989373-02AB-4E05-BAC2-0522A641D73A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:aliasrobotics:mir200_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.8.1.1\",\"matchCriteriaId\":\"78E261B1-C56F-4428-9D53-5BBCCACEAFCF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:aliasrobotics:mir200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7BF40B1F-0DD2-4B8A-BFBA-A7E641DC3316\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:aliasrobotics:mir250_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.8.1.1\",\"matchCriteriaId\":\"877EEDC4-E86F-420D-81C6-3F632C787003\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:aliasrobotics:mir250:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BD1AE2A0-D83D-441B-856B-7E6FAB065C0D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:aliasrobotics:mir500_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.8.1.1\",\"matchCriteriaId\":\"335CA5FE-5AFD-4D49-9A88-1CD71C9281BE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:aliasrobotics:mir500:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F57611E0-5CB2-40FD-8420-ED13A1C4863F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:aliasrobotics:mir1000_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.8.1.1\",\"matchCriteriaId\":\"6865A559-8CA9-4F51-AC43-35BDF5201B91\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:aliasrobotics:mir1000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"04043B16-E401-4D2C-9812-71923CEA2716\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:mobile-industrial-robotics:er200_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.8.1.1\",\"matchCriteriaId\":\"39BD42AA-95E1-4A02-BB9D-C54AE6BAF9B2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:mobile-industrial-robotics:er200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D8A47E5E-7754-47EA-B02D-8A7F54124ED4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:enabled-robotics:er-lite_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.8.1.1\",\"matchCriteriaId\":\"DF0E5CFB-6C15-4BB1-97D8-DD52F68190DD\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:enabled-robotics:er-lite:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"472A560B-547D-4C9F-BE86-ED602FA32799\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:enabled-robotics:er-flex_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.8.1.1\",\"matchCriteriaId\":\"D5528AFD-75DF-4296-9A29-4BD00AB76273\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:enabled-robotics:er-flex:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"654488E4-161E-40B5-9E0B-BE68F5F38E91\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:enabled-robotics:er-one_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.8.1.1\",\"matchCriteriaId\":\"CD6E62F4-9C15-49AA-BFB7-81443D40B9B9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:enabled-robotics:er-one:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1BB77317-78C0-4800-8E1D-498979B6CB06\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:uvd-robots:uvd_robots_firmware:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"2.8.1.1\",\"matchCriteriaId\":\"A7452D74-36A5-4C87-AA20-8E9A80724EAA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:uvd-robots:uvd_robots:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4FD4ACEB-1184-47AB-86E4-732DA183E8AE\"}]}]}],\"references\":[{\"url\":\"https://github.com/aliasrobotics/RVD/issues/2557\",\"source\":\"cve@aliasrobotics.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.