cve-2020-14489
Vulnerability from cvelistv5
Published
2020-07-29 12:24
Modified
2024-09-17 01:46
Severity ?
EPSS score ?
Summary
OpenClinic GA
References
▼ | URL | Tags | |
---|---|---|---|
ics-cert@hq.dhs.gov | https://us-cert.cisa.gov/ics/advisories/ICSMA-20-184-01 | Third Party Advisory, US Government Resource |
Impacted products
▼ | Vendor | Product |
---|---|---|
open source | OpenClinic GA |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T12:46:34.569Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://us-cert.cisa.gov/ics/advisories/ICSMA-20-184-01" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "OpenClinic GA", "vendor": "open source", "versions": [ { "status": "affected", "version": "5.09.02" }, { "status": "affected", "version": "5.89.05b" } ] } ], "credits": [ { "lang": "en", "value": "Brian D. Hysell reported these vulnerabilities to CISA." } ], "datePublic": "2020-07-02T00:00:00", "descriptions": [ { "lang": "en", "value": "OpenClinic GA 5.09.02 and 5.89.05b stores passwords using inadequate hashing complexity, which may allow an attacker to recover passwords using known password cracking techniques." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 6.2, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-522", "description": "INSUFFICIENTLY PROTECTED CREDENTIALS CWE-522", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-07-29T12:24:11", "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://us-cert.cisa.gov/ics/advisories/ICSMA-20-184-01" } ], "source": { "advisory": "ICSMA-20-184-01 OpenClinic GA", "discovery": "EXTERNAL" }, "title": "OpenClinic GA", "workarounds": [ { "lang": "en", "value": "OpenClinic GA is aware of these vulnerabilities but has not provided any confirmation of their resolution. Please upgrade to the latest version to ensure you have all current fixes." } ], "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "DATE_PUBLIC": "2020-07-02T00:00:00.000Z", "ID": "CVE-2020-14489", "STATE": "PUBLIC", "TITLE": "OpenClinic GA" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "OpenClinic GA", "version": { "version_data": [ { "version_affected": "=", "version_value": "5.09.02" }, { "version_affected": "=", "version_value": "5.89.05b" } ] } } ] }, "vendor_name": "open source" } ] } }, "credit": [ { "lang": "eng", "value": "Brian D. Hysell reported these vulnerabilities to CISA." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "OpenClinic GA 5.09.02 and 5.89.05b stores passwords using inadequate hashing complexity, which may allow an attacker to recover passwords using known password cracking techniques." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 6.2, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "INSUFFICIENTLY PROTECTED CREDENTIALS CWE-522" } ] } ] }, "references": { "reference_data": [ { "name": "https://us-cert.cisa.gov/ics/advisories/ICSMA-20-184-01", "refsource": "MISC", "url": "https://us-cert.cisa.gov/ics/advisories/ICSMA-20-184-01" } ] }, "source": { "advisory": "ICSMA-20-184-01 OpenClinic GA", "discovery": "EXTERNAL" }, "work_around": [ { "lang": "en", "value": "OpenClinic GA is aware of these vulnerabilities but has not provided any confirmation of their resolution. Please upgrade to the latest version to ensure you have all current fixes." } ] } } }, "cveMetadata": { "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "cveId": "CVE-2020-14489", "datePublished": "2020-07-29T12:24:11.103756Z", "dateReserved": "2020-06-19T00:00:00", "dateUpdated": "2024-09-17T01:46:22.188Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-14489\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2020-07-29T13:15:09.993\",\"lastModified\":\"2020-07-30T16:12:56.283\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"OpenClinic GA 5.09.02 and 5.89.05b stores passwords using inadequate hashing complexity, which may allow an attacker to recover passwords using known password cracking techniques.\"},{\"lang\":\"es\",\"value\":\"OpenClinic GA versiones 5.09.02 y 5.89.05b, almacena contrase\u00f1as con una complejidad de hash inadecuada, lo que puede permitir a un atacante recuperar contrase\u00f1as usando t\u00e9cnicas conocidas de descifrado de contrase\u00f1as\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":6.2,\"baseSeverity\":\"MEDIUM\"},\"exploitabilityScore\":2.5,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":5.0},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-522\"}]},{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-522\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:openclinic_ga_project:openclinic_ga:5.09.02:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A64E5CCD-1F0D-46B2-9AE7-C917928D2788\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:openclinic_ga_project:openclinic_ga:5.89.05b:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BE2E5CDB-B864-45E4-A7EA-D7EE93BC2453\"}]}]}],\"references\":[{\"url\":\"https://us-cert.cisa.gov/ics/advisories/ICSMA-20-184-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.