Summary
Running security scans against the SAN switch can cause config and secnotify processes within the firmware before Brocade Fabric OS v9.0.0, v8.2.2d and v8.2.1e to consume all memory leading to denial of service impacts possibly including a switch panic.
References
Impacted products
Vendor | Product | Version | ||
---|---|---|---|---|
n/a | Brocade Fabric OS |
Version: Brocade Fabric OS versions before v9.0.0, v8.2.2d, and v8.2.1e |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T13:15:20.568Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1496" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://security.netapp.com/advisory/ntap-20210819-0002/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Brocade Fabric OS", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Brocade Fabric OS versions before v9.0.0, v8.2.2d, and v8.2.1e" } ] } ], "descriptions": [ { "lang": "en", "value": "Running security scans against the SAN switch can cause config and secnotify processes within the firmware before Brocade Fabric OS v9.0.0, v8.2.2d and v8.2.1e to consume all memory leading to denial of service impacts possibly including a switch panic." } ], "problemTypes": [ { "descriptions": [ { "description": "Denail of Service", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-08-19T09:06:25", "orgId": "87b297d7-335e-4844-9551-11b97995a791", "shortName": "brocade" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1496" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://security.netapp.com/advisory/ntap-20210819-0002/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "sirt@brocade.com", "ID": "CVE-2020-15383", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Brocade Fabric OS", "version": { "version_data": [ { "version_value": "Brocade Fabric OS versions before v9.0.0, v8.2.2d, and v8.2.1e" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Running security scans against the SAN switch can cause config and secnotify processes within the firmware before Brocade Fabric OS v9.0.0, v8.2.2d and v8.2.1e to consume all memory leading to denial of service impacts possibly including a switch panic." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Denail of Service" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1496", "refsource": "MISC", "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1496" }, { "name": "https://security.netapp.com/advisory/ntap-20210819-0002/", "refsource": "CONFIRM", "url": "https://security.netapp.com/advisory/ntap-20210819-0002/" } ] } } } }, "cveMetadata": { "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791", "assignerShortName": "brocade", "cveId": "CVE-2020-15383", "datePublished": "2021-06-09T14:32:31", "dateReserved": "2020-06-29T00:00:00", "dateUpdated": "2024-08-04T13:15:20.568Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "fkie_nvd": { "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"8.2.1\", \"matchCriteriaId\": \"017C502B-C9AA-41EF-BBE1-F34DAD9A21F4\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:broadcom:fabric_operating_system:8.2.1:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0C91FB6C-7BF5-453E-A618-06756D3DD2FB\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:broadcom:fabric_operating_system:8.2.1a:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7CF38E78-8243-4615-A8A1-1396920F5BA1\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:broadcom:fabric_operating_system:8.2.1b:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"84E4F075-D03B-4D98-8C9E-840D80DFFF48\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:broadcom:fabric_operating_system:8.2.1c:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CDDF78F1-A7F3-4656-AD5D-6D84F83B34F0\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:broadcom:fabric_operating_system:8.2.1d:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"DAA3D3F6-C768-4096-A2CA-8CC406A92D6B\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:broadcom:fabric_operating_system:8.2.2a1:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"441E912B-4DD8-4A04-8072-04CE30D5A436\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:broadcom:fabric_operating_system:8.2.2b:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"B3B33CEA-BE17-411D-86FF-388B21E8F018\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:broadcom:fabric_operating_system:8.2.2c:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D4CB0EA0-D553-4D17-867A-0DBD5D1F6764\"}]}]}]", "descriptions": "[{\"lang\": \"en\", \"value\": \"Running security scans against the SAN switch can cause config and secnotify processes within the firmware before Brocade Fabric OS v9.0.0, v8.2.2d and v8.2.1e to consume all memory leading to denial of service impacts possibly including a switch panic.\"}, {\"lang\": \"es\", \"value\": \"Una ejecuci\\u00f3n de escaneos de seguridad contra el SAN switch puede causar a los procesos de configuraci\\u00f3n y notificaci\\u00f3n secundaria dentro de las versiones de firmware anteriores a Brocade Fabric OS v9.0.0, v8.2.2d y v8.2.1e, consumir toda la memoria, conllevando a impactos de denegaci\\u00f3n de servicio que posiblemente incluyen un switch panic\"}]", "id": "CVE-2020-15383", "lastModified": "2024-11-21T05:05:27.397", "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:N/I:N/A:P\", \"baseScore\": 5.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}", "published": "2021-06-09T15:15:08.107", "references": "[{\"url\": \"https://security.netapp.com/advisory/ntap-20210819-0002/\", \"source\": \"sirt@brocade.com\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1496\", \"source\": \"sirt@brocade.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://security.netapp.com/advisory/ntap-20210819-0002/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1496\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]", "sourceIdentifier": "sirt@brocade.com", "vulnStatus": "Modified", "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-noinfo\"}]}]" }, "nvd": "{\"cve\":{\"id\":\"CVE-2020-15383\",\"sourceIdentifier\":\"sirt@brocade.com\",\"published\":\"2021-06-09T15:15:08.107\",\"lastModified\":\"2024-11-21T05:05:27.397\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Running security scans against the SAN switch can cause config and secnotify processes within the firmware before Brocade Fabric OS v9.0.0, v8.2.2d and v8.2.1e to consume all memory leading to denial of service impacts possibly including a switch panic.\"},{\"lang\":\"es\",\"value\":\"Una ejecuci\u00f3n de escaneos de seguridad contra el SAN switch puede causar a los procesos de configuraci\u00f3n y notificaci\u00f3n secundaria dentro de las versiones de firmware anteriores a Brocade Fabric OS v9.0.0, v8.2.2d y v8.2.1e, consumir toda la memoria, conllevando a impactos de denegaci\u00f3n de servicio que posiblemente incluyen un switch panic\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2.1\",\"matchCriteriaId\":\"017C502B-C9AA-41EF-BBE1-F34DAD9A21F4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:broadcom:fabric_operating_system:8.2.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0C91FB6C-7BF5-453E-A618-06756D3DD2FB\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:broadcom:fabric_operating_system:8.2.1a:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7CF38E78-8243-4615-A8A1-1396920F5BA1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:broadcom:fabric_operating_system:8.2.1b:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"84E4F075-D03B-4D98-8C9E-840D80DFFF48\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:broadcom:fabric_operating_system:8.2.1c:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CDDF78F1-A7F3-4656-AD5D-6D84F83B34F0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:broadcom:fabric_operating_system:8.2.1d:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DAA3D3F6-C768-4096-A2CA-8CC406A92D6B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:broadcom:fabric_operating_system:8.2.2a1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"441E912B-4DD8-4A04-8072-04CE30D5A436\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:broadcom:fabric_operating_system:8.2.2b:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B3B33CEA-BE17-411D-86FF-388B21E8F018\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:broadcom:fabric_operating_system:8.2.2c:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D4CB0EA0-D553-4D17-867A-0DBD5D1F6764\"}]}]}],\"references\":[{\"url\":\"https://security.netapp.com/advisory/ntap-20210819-0002/\",\"source\":\"sirt@brocade.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1496\",\"source\":\"sirt@brocade.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20210819-0002/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1496\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.