cve-2020-15386
Vulnerability from cvelistv5
Published
2021-06-09 15:43
Modified
2024-08-04 13:15
Severity ?
EPSS score ?
Summary
Brocade Fabric OS prior to v9.0.1a and 8.2.3a and after v9.0.0 and 8.2.2d may observe high CPU load during security scanning, which could lead to a slower response to CLI commands and other operations.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | n/a | Brocade Fabric OS |
Version: Brocade Fabric OS versions after v9.0.0 and before v9.0.1a, and Brocade Fabric OS versions after v8.2.2d and before v8.2.3a |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T13:15:20.565Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1495" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://security.netapp.com/advisory/ntap-20210819-0002/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Brocade Fabric OS", "vendor": "n/a", "versions": [ { "status": "affected", "version": "Brocade Fabric OS versions after v9.0.0 and before v9.0.1a, and Brocade Fabric OS versions after v8.2.2d and before v8.2.3a" } ] } ], "descriptions": [ { "lang": "en", "value": "Brocade Fabric OS prior to v9.0.1a and 8.2.3a and after v9.0.0 and 8.2.2d may observe high CPU load during security scanning, which could lead to a slower response to CLI commands and other operations." } ], "problemTypes": [ { "descriptions": [ { "description": "Denial of Service", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2021-08-19T09:06:23", "orgId": "87b297d7-335e-4844-9551-11b97995a791", "shortName": "brocade" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1495" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://security.netapp.com/advisory/ntap-20210819-0002/" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "sirt@brocade.com", "ID": "CVE-2020-15386", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Brocade Fabric OS", "version": { "version_data": [ { "version_value": "Brocade Fabric OS versions after v9.0.0 and before v9.0.1a, and Brocade Fabric OS versions after v8.2.2d and before v8.2.3a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Brocade Fabric OS prior to v9.0.1a and 8.2.3a and after v9.0.0 and 8.2.2d may observe high CPU load during security scanning, which could lead to a slower response to CLI commands and other operations." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Denial of Service" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1495", "refsource": "MISC", "url": "https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1495" }, { "name": "https://security.netapp.com/advisory/ntap-20210819-0002/", "refsource": "CONFIRM", "url": "https://security.netapp.com/advisory/ntap-20210819-0002/" } ] } } } }, "cveMetadata": { "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791", "assignerShortName": "brocade", "cveId": "CVE-2020-15386", "datePublished": "2021-06-09T15:43:02", "dateReserved": "2020-06-29T00:00:00", "dateUpdated": "2024-08-04T13:15:20.565Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "fkie_nvd": { "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:broadcom:fabric_operating_system:8.2.3:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8B8758BE-527C-40EA-BFE6-848A1C87723F\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:broadcom:fabric_operating_system:9.0.0a:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"194BFCDA-1FBD-4082-9792-A3F0C72CDA34\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:broadcom:fabric_operating_system:9.0.0b:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"21C4BCF7-4B42-4D32-B9CF-FBC5C882F08B\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:broadcom:fabric_operating_system:9.0.1:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3AAD9957-CACE-472A-86F5-144AEA651948\"}]}]}]", "descriptions": "[{\"lang\": \"en\", \"value\": \"Brocade Fabric OS prior to v9.0.1a and 8.2.3a and after v9.0.0 and 8.2.2d may observe high CPU load during security scanning, which could lead to a slower response to CLI commands and other operations.\"}, {\"lang\": \"es\", \"value\": \"Brocade Fabric OS versiones anteriores a v9.0.1a y 8.2.3a y posteriores a v9.0.0 y 8.2.2d, puede observar una alta carga de la CPU durante un escaneo de seguridad, lo que podr\\u00eda conllevar una respuesta m\\u00e1s lenta a los comandos CLI y otras operaciones\"}]", "id": "CVE-2020-15386", "lastModified": "2024-11-21T05:05:27.713", "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\", \"baseScore\": 5.3, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"LOW\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 1.4}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:N/I:N/A:P\", \"baseScore\": 5.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 10.0, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}", "published": "2021-06-09T16:15:08.270", "references": "[{\"url\": \"https://security.netapp.com/advisory/ntap-20210819-0002/\", \"source\": \"sirt@brocade.com\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1495\", \"source\": \"sirt@brocade.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://security.netapp.com/advisory/ntap-20210819-0002/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1495\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]", "sourceIdentifier": "sirt@brocade.com", "vulnStatus": "Modified", "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-noinfo\"}]}]" }, "nvd": "{\"cve\":{\"id\":\"CVE-2020-15386\",\"sourceIdentifier\":\"sirt@brocade.com\",\"published\":\"2021-06-09T16:15:08.270\",\"lastModified\":\"2024-11-21T05:05:27.713\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Brocade Fabric OS prior to v9.0.1a and 8.2.3a and after v9.0.0 and 8.2.2d may observe high CPU load during security scanning, which could lead to a slower response to CLI commands and other operations.\"},{\"lang\":\"es\",\"value\":\"Brocade Fabric OS versiones anteriores a v9.0.1a y 8.2.3a y posteriores a v9.0.0 y 8.2.2d, puede observar una alta carga de la CPU durante un escaneo de seguridad, lo que podr\u00eda conllevar una respuesta m\u00e1s lenta a los comandos CLI y otras operaciones\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:N/I:N/A:P\",\"baseScore\":5.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:broadcom:fabric_operating_system:8.2.3:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8B8758BE-527C-40EA-BFE6-848A1C87723F\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:broadcom:fabric_operating_system:9.0.0a:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"194BFCDA-1FBD-4082-9792-A3F0C72CDA34\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:broadcom:fabric_operating_system:9.0.0b:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"21C4BCF7-4B42-4D32-B9CF-FBC5C882F08B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:broadcom:fabric_operating_system:9.0.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3AAD9957-CACE-472A-86F5-144AEA651948\"}]}]}],\"references\":[{\"url\":\"https://security.netapp.com/advisory/ntap-20210819-0002/\",\"source\":\"sirt@brocade.com\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1495\",\"source\":\"sirt@brocade.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20210819-0002/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.broadcom.com/support/fibre-channel-networking/security-advisories/brocade-security-advisory-2021-1495\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.