Action not permitted
Modal body text goes here.
cve-2020-1968
Vulnerability from cvelistv5
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T06:54:00.367Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.openssl.org/news/secadv/20200909.txt" }, { "name": "USN-4504-1", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://usn.ubuntu.com/4504-1/" }, { "name": "[debian-lts-announce] 20200925 [SECURITY] [DLA 2378-1] openssl1.0 security update", "tags": [ "mailing-list", "x_transferred" ], "url": "https://lists.debian.org/debian-lts-announce/2020/09/msg00016.html" }, { "tags": [ "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpujan2021.html" }, { "tags": [ "x_transferred" ], "url": "https://security.netapp.com/advisory/ntap-20200911-0004/" }, { "tags": [ "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpuApr2021.html" }, { "tags": [ "x_transferred" ], "url": "https://www.oracle.com//security-alerts/cpujul2021.html" }, { "tags": [ "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpuoct2021.html" }, { "tags": [ "x_transferred" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" }, { "name": "GLSA-202210-02", "tags": [ "vendor-advisory", "x_transferred" ], "url": "https://security.gentoo.org/glsa/202210-02" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "OpenSSL", "vendor": "OpenSSL", "versions": [ { "status": "affected", "version": "Fixed in OpenSSL 1.0.2w (Affected 1.0.2-1.0.2v)" } ] } ], "credits": [ { "lang": "en", "value": "Robert Merget, Marcus Brinkmann, Nimrod Aviram, and Juraj Somorovsky" } ], "datePublic": "2020-09-09T00:00:00", "descriptions": [ { "lang": "en", "value": "The Raccoon attack exploits a flaw in the TLS specification which can lead to an attacker being able to compute the pre-master secret in connections which have used a Diffie-Hellman (DH) based ciphersuite. In such a case this would result in the attacker being able to eavesdrop on all encrypted communications sent over that TLS connection. The attack can only be exploited if an implementation re-uses a DH secret across multiple TLS connections. Note that this issue only impacts DH ciphersuites and not ECDH ciphersuites. This issue affects OpenSSL 1.0.2 which is out of support and no longer receiving public updates. OpenSSL 1.1.1 is not vulnerable to this issue. Fixed in OpenSSL 1.0.2w (Affected 1.0.2-1.0.2v)." } ], "metrics": [ { "other": { "content": { "lang": "eng", "url": "https://www.openssl.org/policies/secpolicy.html#Low", "value": "Low" }, "type": "unknown" } } ], "problemTypes": [ { "descriptions": [ { "description": "Protocol flaw", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-10-16T00:00:00", "orgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5", "shortName": "openssl" }, "references": [ { "url": "https://www.openssl.org/news/secadv/20200909.txt" }, { "name": "USN-4504-1", "tags": [ "vendor-advisory" ], "url": "https://usn.ubuntu.com/4504-1/" }, { "name": "[debian-lts-announce] 20200925 [SECURITY] [DLA 2378-1] openssl1.0 security update", "tags": [ "mailing-list" ], "url": "https://lists.debian.org/debian-lts-announce/2020/09/msg00016.html" }, { "url": "https://www.oracle.com/security-alerts/cpujan2021.html" }, { "url": "https://security.netapp.com/advisory/ntap-20200911-0004/" }, { "url": "https://www.oracle.com/security-alerts/cpuApr2021.html" }, { "url": "https://www.oracle.com//security-alerts/cpujul2021.html" }, { "url": "https://www.oracle.com/security-alerts/cpuoct2021.html" }, { "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" }, { "name": "GLSA-202210-02", "tags": [ "vendor-advisory" ], "url": "https://security.gentoo.org/glsa/202210-02" } ], "title": "Raccoon attack" } }, "cveMetadata": { "assignerOrgId": "3a12439a-ef3a-4c79-92e6-6081a721f1e5", "assignerShortName": "openssl", "cveId": "CVE-2020-1968", "datePublished": "2020-09-09T13:50:12.423004Z", "dateReserved": "2019-12-03T00:00:00", "dateUpdated": "2024-09-16T19:50:54.434Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2020-1968\",\"sourceIdentifier\":\"openssl-security@openssl.org\",\"published\":\"2020-09-09T14:15:12.507\",\"lastModified\":\"2022-11-21T19:48:16.117\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"The Raccoon attack exploits a flaw in the TLS specification which can lead to an attacker being able to compute the pre-master secret in connections which have used a Diffie-Hellman (DH) based ciphersuite. In such a case this would result in the attacker being able to eavesdrop on all encrypted communications sent over that TLS connection. The attack can only be exploited if an implementation re-uses a DH secret across multiple TLS connections. Note that this issue only impacts DH ciphersuites and not ECDH ciphersuites. This issue affects OpenSSL 1.0.2 which is out of support and no longer receiving public updates. OpenSSL 1.1.1 is not vulnerable to this issue. Fixed in OpenSSL 1.0.2w (Affected 1.0.2-1.0.2v).\"},{\"lang\":\"es\",\"value\":\"El ataque Raccoon explota un fallo en la especificaci\u00f3n TLS que puede conllevar a que un atacante sea capaz de calcular el secreto pre-master en conexiones que han usado un conjunto de cifrado basado en Diffie-Hellman (DH).\u0026#xa0;En tal caso, esto har\u00eda que el atacante pudiera espiar todas las comunicaciones cifradas enviadas por medio de esa conexi\u00f3n TLS.\u0026#xa0;El ataque solo puede ser explotado si una implementaci\u00f3n reutiliza un secreto de DH en varias conexiones TLS.\u0026#xa0;Tome en cuenta que este problema solo afecta a los conjuntos de cifrado DH y no a los conjuntos de cifrado ECDH.\u0026#xa0;Este problema afecta a OpenSSL versi\u00f3n 1.0.2, que no es compatible y ya no recibe actualizaciones p\u00fablicas.\u0026#xa0;OpenSSL versi\u00f3n 1.1.1 no es vulnerable a este problema.\u0026#xa0;Corregido en OpenSSL versi\u00f3n 1.0.2w (Afectadas versiones 1.0.2-1.0.2v).\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":3.7,\"baseSeverity\":\"LOW\"},\"exploitabilityScore\":2.2,\"impactScore\":1.4}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:N/A:N\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":4.3},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-203\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"1.0.2\",\"versionEndIncluding\":\"1.0.2v\",\"matchCriteriaId\":\"A05055C5-49F7-4B9F-B2DC-D192296C41F0\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:canonical:ubuntu_linux:16.04:*:*:*:lts:*:*:*\",\"matchCriteriaId\":\"F7016A2A-8365-4F1A-89A2-7A19F2BCAE5B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:canonical:ubuntu_linux:18.04:*:*:*:lts:*:*:*\",\"matchCriteriaId\":\"23A7C53F-B80F-4E6A-AFA9-58EEA84BE11D\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DEECE5FC-CACF-4496-A3E7-164736409252\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:jd_edwards_world_security:a9.4:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0B1CAD50-749F-4ADB-A046-BF3585677A58\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.56:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D0A735B4-4F3C-416B-8C08-9CB21BAD2889\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.57:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7E1E416B-920B-49A0-9523-382898C2979D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.58:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D9DB4A14-2EF5-4B54-95D2-75E6CF9AA0A9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:oracle:ethernet_switch_es2-64:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D4AB93AB-A30F-40AE-8246-10036FF077FE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:oracle:ethernet_switch_es2-64_firmware:2.0.0.14:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8B0403A9-E552-48CA-9CD5-31B48684FF70\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:oracle:ethernet_switch_es2-72:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0D4E5146-C8E3-40D2-93D9-F9E85768A5B4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:oracle:ethernet_switch_es2-72_firmware:2.0.0.14:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4F58DF8F-5478-4E00-BF9D-14BA3B79DA99\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fujitsu:m10-1:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"983D27DE-BC89-454E-AE47-95A26A3651E2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fujitsu:m10-1_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"xcp2400\",\"matchCriteriaId\":\"9C3CF24D-2DE4-4E3B-B36E-D952D0E65E0B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fujitsu:m10-4:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5825AEE1-B668-40BD-86A9-2799430C742C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fujitsu:m10-4_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"xcp2400\",\"matchCriteriaId\":\"9F742415-8605-4B83-9410-BDA07BABF740\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fujitsu:m10-4s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3DA2D526-BDCF-4A65-914A-B3BA3A0CD613\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fujitsu:m10-4s_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"xcp2400\",\"matchCriteriaId\":\"4E9ED009-8D47-430C-9F59-EE09ECF2299E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fujitsu:m12-1:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EE0CF40B-E5BD-4558-9321-184D58EF621D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fujitsu:m12-1_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"xcp2400\",\"matchCriteriaId\":\"9AB0DC35-F821-49BA-A5F1-45DD086915B0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fujitsu:m12-2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"xcp2400\",\"matchCriteriaId\":\"6DF75FC1-C88D-45DA-BBD0-7EB0B9EED343\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fujitsu:m12-2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0F3C9C09-7B2B-4DB6-8BE0-35302ED35776\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fujitsu:m12-2s_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"xcp2400\",\"matchCriteriaId\":\"9762A1D1-ED90-4E9C-B672-2499ABA48C46\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fujitsu:m12-2s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"95503CE5-1D06-4092-A60D-D310AADCAFB1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fujitsu:m10-1_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"xcp3100\",\"matchCriteriaId\":\"4D2AB72D-52FB-4D23-95FD-D10958F8B936\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fujitsu:m10-1:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"983D27DE-BC89-454E-AE47-95A26A3651E2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fujitsu:m10-4_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"xcp3100\",\"matchCriteriaId\":\"B1198FC6-A33A-4F4D-9643-51DEE8D46E17\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fujitsu:m10-4:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5825AEE1-B668-40BD-86A9-2799430C742C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fujitsu:m10-4s_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"xcp3100\",\"matchCriteriaId\":\"12F2A182-B9A0-4011-9791-435C5709E313\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fujitsu:m10-4s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3DA2D526-BDCF-4A65-914A-B3BA3A0CD613\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fujitsu:m12-1_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"xcp3100\",\"matchCriteriaId\":\"B037D0E6-B857-4539-ADDC-FE2ADC2B0C2F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fujitsu:m12-1:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EE0CF40B-E5BD-4558-9321-184D58EF621D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fujitsu:m12-2_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"xcp3100\",\"matchCriteriaId\":\"968A6DC3-9E0B-4FBD-8AAB-2ECD8CE47D23\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fujitsu:m12-2:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0F3C9C09-7B2B-4DB6-8BE0-35302ED35776\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:fujitsu:m12-2s_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"xcp3100\",\"matchCriteriaId\":\"C219921D-966D-4EAC-A129-9D4BFE6FCD36\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:fujitsu:m12-2s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"95503CE5-1D06-4092-A60D-D310AADCAFB1\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:oracle:ethernet_switch_es1-24_firmware:1.3.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EDA6CD79-6D03-44C6-BA41-F190E5037EF3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:oracle:ethernet_switch_es1-24:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"62136C7B-992F-4889-9394-B233533636E3\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:oracle:ethernet_switch_tor-72_firmware:1.2.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FCDF5167-832D-4483-AD01-6534111196FB\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:oracle:ethernet_switch_tor-72:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"03657F1F-618B-479D-AD29-BB58AF1A3819\"}]}]}],\"references\":[{\"url\":\"https://lists.debian.org/debian-lts-announce/2020/09/msg00016.html\",\"source\":\"openssl-security@openssl.org\",\"tags\":[\"Mailing List\",\"Third Party Advisory\"]},{\"url\":\"https://security.gentoo.org/glsa/202210-02\",\"source\":\"openssl-security@openssl.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://security.netapp.com/advisory/ntap-20200911-0004/\",\"source\":\"openssl-security@openssl.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://usn.ubuntu.com/4504-1/\",\"source\":\"openssl-security@openssl.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.openssl.org/news/secadv/20200909.txt\",\"source\":\"openssl-security@openssl.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.oracle.com//security-alerts/cpujul2021.html\",\"source\":\"openssl-security@openssl.org\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://www.oracle.com/security-alerts/cpuApr2021.html\",\"source\":\"openssl-security@openssl.org\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://www.oracle.com/security-alerts/cpuapr2022.html\",\"source\":\"openssl-security@openssl.org\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://www.oracle.com/security-alerts/cpujan2021.html\",\"source\":\"openssl-security@openssl.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.oracle.com/security-alerts/cpuoct2021.html\",\"source\":\"openssl-security@openssl.org\",\"tags\":[\"Patch\",\"Third Party Advisory\"]}]}}" } }
icsa-21-336-08
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Hitachi Energy", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to eavesdrop on traffic, retrieve information from memory, or cause a denial-of-service condition.", "title": "Risk evaluation" }, { "category": "other", "text": "Energy", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Switzerland", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-21-336-08 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-336-08.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-336-08 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-336-08" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Hitachi Energy RTU500 series", "tracking": { "current_release_date": "2021-12-02T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-336-08", "initial_release_date": "2021-12-02T00:00:00.000000Z", "revision_history": [ { "date": "2021-12-02T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-336-08 Hitachi Energy RTU500 series" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version", "name": "12.2.*", "product": { "name": "RTU500 series CMU Firmware: Version 12.2.*", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "RTU500 series CMU Firmware" }, { "branches": [ { "category": "product_version", "name": "13.1.*", "product": { "name": "RTU500 series CMU Firmware: Version 13.1.*", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "RTU500 series CMU Firmware" }, { "branches": [ { "category": "product_version", "name": "13.0.*", "product": { "name": "RTU500 series CMU Firmware: Version 13.0.*", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "RTU500 series CMU Firmware" }, { "branches": [ { "category": "product_version", "name": "12.0.*", "product": { "name": "RTU500 series CMU Firmware: Version 12.0.*", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "RTU500 series CMU Firmware" }, { "branches": [ { "category": "product_version", "name": "12.6.*", "product": { "name": "RTU500 series CMU Firmware: Version 12.6.*", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "RTU500 series CMU Firmware" }, { "branches": [ { "category": "product_version", "name": "12.4.*", "product": { "name": "RTU500 series CMU Firmware: Version 12.4.*", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "RTU500 series CMU Firmware" }, { "branches": [ { "category": "product_version", "name": "11.*", "product": { "name": "RTU500 series CMU Firmware: Version 11.*", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "RTU500 series CMU Firmware" }, { "branches": [ { "category": "product_version", "name": "12.7.*", "product": { "name": "RTU500 series CMU Firmware: Version 12.7.*", "product_id": "CSAFPID-0008" } } ], "category": "product_name", "name": "RTU500 series CMU Firmware" }, { "branches": [ { "category": "product_version", "name": "13.2.1", "product": { "name": "RTU500 series CMU Firmware: Version 13.2.1", "product_id": "CSAFPID-0009" } } ], "category": "product_name", "name": "RTU500 series CMU Firmware" } ], "category": "vendor", "name": "Hitachi Energy" } ] }, "vulnerabilities": [ { "cve": "CVE-2020-1968", "cwe": { "id": "CWE-203", "name": "Observable Discrepancy" }, "notes": [ { "category": "summary", "text": "The Raccoon attack exploits a flaw in the TLS specification, which can lead to an attacker computing pre-master secret in connections that have used a Diffie-Hellman- based cipher suite. An attacker can then eavesdrop on all encrypted communications sent over the exploited TLS connection.CVE-2020-1968 has been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-1968" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 11.*: This product version is end-of-life (EOL). Upgrade to a non-affected support version. See below for the current mitigation strategy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 12.0.1 - 12.0.13: Update to RTU500 series CMU Firmware Version 12.0.14 (to be released by end-of-February 2022). See below for the current mitigation strategy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 12.2.1 - 12.2.10: Update to RTU500 series CMU Firmware as of Version 12.2.11", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 12.4.1 - 12.4.10: Update to RTU500 CMU Firmware as of Version 12.4.11 (to be released by end-of-January 2022). See below for the current mitigation strategy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 12.6.1 - 12.6.6: Update to RTU500 series CMU firmware as of Version 12.6.7. See below for the current mitigation strategy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 12.7.1: Update to RTU500 series CMU Firmware as of Version 12.7.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 13.0.1 - 13.0.2: Upgrade to the latest RTU500 series CMU Firmware as of Version 13.2.3. See below for the current mitigation strategy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 13.1.1 - 13.1.2: Upgrade to the latest RTU500 series CMU Firmware as of Version 13.2.3. See below for the current mitigation strategy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 13.2.1: Upgrade to the latest RTU500 series CMU Firmware as of Version 13.2.3. See below for the current mitigation strategy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "mitigation", "details": "Physically protect process control systems from direct access by unauthorized personnel.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "mitigation", "details": "Do not directly connect to the Internet.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "mitigation", "details": "Separate from other networks by means of a firewall system that has a minimal number of ports exposed.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "mitigation", "details": "Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "mitigation", "details": "Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "mitigation", "details": "Please see Hitachi Energy advisory 8DBD000064 for additional mitigation and update information.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000064\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 3.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] } ] }, { "cve": "CVE-2020-24977", "cwe": { "id": "CWE-126", "name": "Buffer Over-read" }, "notes": [ { "category": "summary", "text": "There is a global buffer over-read vulnerability in xmlEncodeEntitiesInternal in the affected libxml2/entities.c.CVE-2020-24977 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-24977" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L" } ], "remediations": [ { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 11.*: This product version is end-of-life (EOL). Upgrade to a non-affected support version. See below for the current mitigation strategy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 12.0.1 - 12.0.13: Update to RTU500 series CMU Firmware Version 12.0.14 (to be released by end-of-February 2022). See below for the current mitigation strategy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 12.2.1 - 12.2.10: Update to RTU500 series CMU Firmware as of Version 12.2.11", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 12.4.1 - 12.4.10: Update to RTU500 CMU Firmware as of Version 12.4.11 (to be released by end-of-January 2022). See below for the current mitigation strategy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 12.6.1 - 12.6.6: Update to RTU500 series CMU firmware as of Version 12.6.7. See below for the current mitigation strategy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 12.7.1: Update to RTU500 series CMU Firmware as of Version 12.7.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 13.0.1 - 13.0.2: Upgrade to the latest RTU500 series CMU Firmware as of Version 13.2.3. See below for the current mitigation strategy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 13.1.1 - 13.1.2: Upgrade to the latest RTU500 series CMU Firmware as of Version 13.2.3. See below for the current mitigation strategy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 13.2.1: Upgrade to the latest RTU500 series CMU Firmware as of Version 13.2.3. See below for the current mitigation strategy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "mitigation", "details": "Physically protect process control systems from direct access by unauthorized personnel.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "mitigation", "details": "Do not directly connect to the Internet.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "mitigation", "details": "Separate from other networks by means of a firewall system that has a minimal number of ports exposed.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "mitigation", "details": "Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "mitigation", "details": "Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "mitigation", "details": "Please see Hitachi Energy advisory 8DBD000064 for additional mitigation and update information.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000064\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] } ] }, { "cve": "CVE-2021-3517", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "A vulnerability exists in the xml entity encoding functionality of the affected libxml2. An attacker can use a specially crafted file to trigger an out-of-bounds read.CVE-2021-3517 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-3517" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 11.*: This product version is end-of-life (EOL). Upgrade to a non-affected support version. See below for the current mitigation strategy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 12.0.1 - 12.0.13: Update to RTU500 series CMU Firmware Version 12.0.14 (to be released by end-of-February 2022). See below for the current mitigation strategy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 12.2.1 - 12.2.10: Update to RTU500 series CMU Firmware as of Version 12.2.11", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 12.4.1 - 12.4.10: Update to RTU500 CMU Firmware as of Version 12.4.11 (to be released by end-of-January 2022). See below for the current mitigation strategy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 12.6.1 - 12.6.6: Update to RTU500 series CMU firmware as of Version 12.6.7. See below for the current mitigation strategy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 12.7.1: Update to RTU500 series CMU Firmware as of Version 12.7.2", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 13.0.1 - 13.0.2: Upgrade to the latest RTU500 series CMU Firmware as of Version 13.2.3. See below for the current mitigation strategy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 13.1.1 - 13.1.2: Upgrade to the latest RTU500 series CMU Firmware as of Version 13.2.3. See below for the current mitigation strategy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "vendor_fix", "details": "RTU500 series CMU Firmware Version 13.2.1: Upgrade to the latest RTU500 series CMU Firmware as of Version 13.2.3. See below for the current mitigation strategy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "mitigation", "details": "Physically protect process control systems from direct access by unauthorized personnel.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "mitigation", "details": "Do not directly connect to the Internet.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "mitigation", "details": "Separate from other networks by means of a firewall system that has a minimal number of ports exposed.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "mitigation", "details": "Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "mitigation", "details": "Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] }, { "category": "mitigation", "details": "Please see Hitachi Energy advisory 8DBD000064 for additional mitigation and update information.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000064\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 8.6, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007", "CSAFPID-0008", "CSAFPID-0009" ] } ] } ] }
icsa-22-111-03
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Hitachi Energy", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to eavesdrop on traffic between network source and destination, gain unauthorized access to information, or cause a denial-of-service condition.", "title": "Risk evaluation" }, { "category": "other", "text": "Energy", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Switzerland", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-22-111-03 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-111-03.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-111-03 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-111-03" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Hitachi Energy MicroSCADA Pro/X SYS600", "tracking": { "current_release_date": "2022-04-21T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-111-03", "initial_release_date": "2022-04-21T00:00:00.000000Z", "revision_history": [ { "date": "2022-04-21T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-22-111-03 Hitachi Energy MicroSCADA ProX SYS600" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c= 10.1.1", "product": { "name": " SYS600: Versions 10.1.1 and prior", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": " SYS600" }, { "branches": [ { "category": "product_version_range", "name": "\u003c=9.4 FP1 | \u003e= 10.2.1", "product": { "name": " SYS600: Versions 10.1.1 and prior", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": " SYS600" }, { "branches": [ { "category": "product_version_range", "name": "\u003e= 10.0.0 | \u003c= 10.2.1", "product": { "name": " SYS600: Versions 10.1.1 and prior", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": " SYS600" } ], "category": "vendor", "name": "Hitachi Energy" } ] }, "vulnerabilities": [ { "cve": "CVE-2020-1968", "cwe": { "id": "CWE-203", "name": "Observable Discrepancy" }, "notes": [ { "category": "summary", "text": "The Raccoon attack exploits a flaw in the TLS specification that can lead to an attacker being able to compute the pre-master secret in connections which have used a Diffie-Hellman (DH) based ciphersuite. This would result in the attacker being able to eavesdrop on all encrypted communications sent over that TLS connection. The attack can only be exploited if an implementation re-uses a DH secret across multiple TLS connections. Note this vulnerability only impacts DH ciphersuites and not ECDH ciphersuites. This vulnerability affects OpenSSL 1.0.2, which is out of support and no longer receiving public updates. OpenSSL 1.1.1 is not vulnerable to this issue. Fixed in OpenSSL 1.0.2w (Affected 1.0.2-1.0.2v).CVE-2020-1968 has been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-1968" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Hitachi Energy recommends users update to Versions 10.3 or later. For obtaining the update users should contact the Hitachi Energy technical support team. If users don\u0027t know who to contact, they should reach the closest Hitachi Energy sales office.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Hitachi Energy recommends security practices and firewall configurations to help protect process control networks from attacks that originate from outside the network. Such practices include physically protecting process control systems from direct access by unauthorized personnel, having no direct connections to the Internet, separating from other networks by means of a firewall system that has a minimal number of ports exposed, and others that must be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "For more information see Hitachi Energy advisory 8DBD000075", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000075\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 3.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2020-8265", "cwe": { "id": "CWE-444", "name": "Inconsistent Interpretation of HTTP Requests (\u0027HTTP Request/Response Smuggling\u0027)" }, "notes": [ { "category": "summary", "text": "Node.js versions prior to 10.23.1, 12.20.1, 14.15.4, 15.5.1 allow two copies of a header field in an HTTP request (for example, two transfer-encoding header fields). In this case, Node.js identifies the first header field and ignores the second. This can lead to HTTP request smuggling.CVE-2020-8265 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8265" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Hitachi Energy recommends users update to Versions 10.3 or later. For obtaining the update users should contact the Hitachi Energy technical support team. If users don\u0027t know who to contact, they should reach the closest Hitachi Energy sales office.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Hitachi Energy recommends security practices and firewall configurations to help protect process control networks from attacks that originate from outside the network. Such practices include physically protecting process control systems from direct access by unauthorized personnel, having no direct connections to the Internet, separating from other networks by means of a firewall system that has a minimal number of ports exposed, and others that must be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "For more information see Hitachi Energy advisory 8DBD000075", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000075\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 8.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2020-8287", "cwe": { "id": "CWE-444", "name": "Inconsistent Interpretation of HTTP Requests (\u0027HTTP Request/Response Smuggling\u0027)" }, "notes": [ { "category": "summary", "text": "Node.js versions prior to 10.23.1, 12.20.1, 14.15.4, 15.5.1 allow two copies of a header field in an HTTP request (for example, two transfer-encoding header fields). In this case, Node.js identifies the first header field and ignores the second. This can lead to HTTP request smuggling.CVE-2020-8287 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8287" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Hitachi Energy recommends users update to Versions 10.3 or later. For obtaining the update users should contact the Hitachi Energy technical support team. If users don\u0027t know who to contact, they should reach the closest Hitachi Energy sales office.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Hitachi Energy recommends security practices and firewall configurations to help protect process control networks from attacks that originate from outside the network. Such practices include physically protecting process control systems from direct access by unauthorized personnel, having no direct connections to the Internet, separating from other networks by means of a firewall system that has a minimal number of ports exposed, and others that must be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "For more information see Hitachi Energy advisory 8DBD000075", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000075\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2020-8201", "cwe": { "id": "CWE-444", "name": "Inconsistent Interpretation of HTTP Requests (\u0027HTTP Request/Response Smuggling\u0027)" }, "notes": [ { "category": "summary", "text": "Node.js \u003c 12.18.4 and \u003c 14.11 can be exploited to perform HTTP desync attacks and deliver malicious payloads to unsuspecting users. The payloads can be crafted by an attacker to hijack user sessions, poison cookies, perform clickjacking, and a multitude of other attacks depending on the architecture of the underlying system. The attack is possible due to a bug in processing of carrier-return symbols in the HTTP header names.CVE-2020-8201 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8201" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Hitachi Energy recommends users update to Versions 10.3 or later. For obtaining the update users should contact the Hitachi Energy technical support team. If users don\u0027t know who to contact, they should reach the closest Hitachi Energy sales office.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Hitachi Energy recommends security practices and firewall configurations to help protect process control networks from attacks that originate from outside the network. Such practices include physically protecting process control systems from direct access by unauthorized personnel, having no direct connections to the Internet, separating from other networks by means of a firewall system that has a minimal number of ports exposed, and others that must be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "For more information see Hitachi Energy advisory 8DBD000075", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000075\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 7.4, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2020-8252", "cwe": { "id": "CWE-120", "name": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" }, "notes": [ { "category": "summary", "text": "The implementation of realpath in libuv \u003c 10.22.1, \u003c 12.18.4, and \u003c 14.9.0 used within Node.js incorrectly determined the buffer size, which can result in a buffer overflow if the resolved path is longer than 256 bytes.CVE-2020-8252 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8252" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Hitachi Energy recommends users update to Versions 10.3 or later. For obtaining the update users should contact the Hitachi Energy technical support team. If users don\u0027t know who to contact, they should reach the closest Hitachi Energy sales office.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Hitachi Energy recommends security practices and firewall configurations to help protect process control networks from attacks that originate from outside the network. Such practices include physically protecting process control systems from direct access by unauthorized personnel, having no direct connections to the Internet, separating from other networks by means of a firewall system that has a minimal number of ports exposed, and others that must be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "For more information see Hitachi Energy advisory 8DBD000075", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000075\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2020-8172", "cwe": { "id": "CWE-295", "name": "Improper Certificate Validation" }, "notes": [ { "category": "summary", "text": "TLS session reuse can lead to host certificate verification bypass in node version \u003c 12.18.0 and \u003c 14.4.0.CVE-2020-8172 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8172" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Hitachi Energy recommends users update to Versions 10.3 or later. For obtaining the update users should contact the Hitachi Energy technical support team. If users don\u0027t know who to contact, they should reach the closest Hitachi Energy sales office.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Hitachi Energy recommends security practices and firewall configurations to help protect process control networks from attacks that originate from outside the network. Such practices include physically protecting process control systems from direct access by unauthorized personnel, having no direct connections to the Internet, separating from other networks by means of a firewall system that has a minimal number of ports exposed, and others that must be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "For more information see Hitachi Energy advisory 8DBD000075", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000075\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 7.4, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2020-8174", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "napi_get_value_string_*() allows various kinds of memory corruption in node \u003c 10.21.0, 12.18.0, and \u003c 14.4.0.CVE-2020-8174 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8174" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Hitachi Energy recommends users update to Versions 10.3 or later. For obtaining the update users should contact the Hitachi Energy technical support team. If users don\u0027t know who to contact, they should reach the closest Hitachi Energy sales office.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Hitachi Energy recommends security practices and firewall configurations to help protect process control networks from attacks that originate from outside the network. Such practices include physically protecting process control systems from direct access by unauthorized personnel, having no direct connections to the Internet, separating from other networks by means of a firewall system that has a minimal number of ports exposed, and others that must be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "For more information see Hitachi Energy advisory 8DBD000075", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000075\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 8.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2021-32027", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "A vulnerability was found in postgresql in versions prior to 13.3, 12.7, 11.12, 10.17, and 9.6.22. While modifying certain SQL array values, missing bounds checks let authenticated database users write arbitrary bytes to a wide area of server memory. The highest threat from this vulnerability is to data confidentiality and integrity as well as system availability.CVE-2021-32027 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32027" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "mitigation", "details": "Hitachi Energy recommends users update to Versions 10.3 or later. For obtaining the update users should contact the Hitachi Energy technical support team. If users don\u0027t know who to contact, they should reach the closest Hitachi Energy sales office.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Hitachi Energy recommends security practices and firewall configurations to help protect process control networks from attacks that originate from outside the network. Such practices include physically protecting process control systems from direct access by unauthorized personnel, having no direct connections to the Internet, separating from other networks by means of a firewall system that has a minimal number of ports exposed, and others that must be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "For more information see Hitachi Energy advisory 8DBD000075", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000075\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 8.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] }, { "cve": "CVE-2021-32028", "cwe": { "id": "CWE-200", "name": "Exposure of Sensitive Information to an Unauthorized Actor" }, "notes": [ { "category": "summary", "text": "A flaw was found in postgresql. Using an INSERT ... ON CONFLICT ... DO UPDATE command on a purpose-crafted table, an authenticated database user could read arbitrary bytes of server memory. The highest threat from this vulnerability is to data confidentiality.CVE-2021-32028 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32028" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "Hitachi Energy recommends users update to Versions 10.3 or later. For obtaining the update users should contact the Hitachi Energy technical support team. If users don\u0027t know who to contact, they should reach the closest Hitachi Energy sales office.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Hitachi Energy recommends security practices and firewall configurations to help protect process control networks from attacks that originate from outside the network. Such practices include physically protecting process control systems from direct access by unauthorized personnel, having no direct connections to the Internet, separating from other networks by means of a firewall system that has a minimal number of ports exposed, and others that must be evaluated case by case. Process control systems should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "For more information see Hitachi Energy advisory 8DBD000075", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000075\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 6.5, "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] } ] }
icsa-22-242-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Hitachi Energy", "summary": "reporting to CISA that FACTS Control Platform was affected by these previously discovered vulnerabilities in open-source software components" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities may allow an attacker to eavesdrop on the traffic between network source and destination, gain unauthorized access to information or cause a denial-of service.", "title": "Risk evaluation" }, { "category": "other", "text": "Energy", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Switzerland", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/icsSeveral recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov/icsin the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are exploitable remotely. These vulnerabilities have a low attack complexity.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-22-242-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-242-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-242-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-242-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-242-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Hitachi Energy FACTS Control Platform (FCP) Product", "tracking": { "current_release_date": "2022-08-30T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-242-01", "initial_release_date": "2022-08-30T00:00:00.000000Z", "revision_history": [ { "date": "2022-08-30T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003e= 3.0.0 | \u003c= 3.12.0", "product": { "name": "FCP: 3.0.0 - 3.12.0", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "FCP" }, { "branches": [ { "category": "product_version_range", "name": "\u003e= 1.1.0 | \u003c= 1.3.0", "product": { "name": "FCP: 1.1.0 - 1.3.0", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "FCP" }, { "branches": [ { "category": "product_version_range", "name": "\u003e= 2.1.0 | \u003c= 2.3.0", "product": { "name": "FCP: 2.1.0 - 2.3.0", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "FCP" } ], "category": "vendor", "name": "Hitachi Energy" } ] }, "vulnerabilities": [ { "cve": "CVE-2020-1968", "cwe": { "id": "CWE-1357", "name": "Reliance on Insufficiently Trustworthy Component" }, "notes": [ { "category": "summary", "text": "Hitachi Energy is aware of public reports of multiple vulnerabilities in open-source software components (OpenSSL and Node.JS) used in the FACTS Control Platform (FCP) product. Versions are available to remediate the identified vulnerabilities.CVE-2020-1968, CVE-2020-8172, CVE-2020-8174, CVE-2020-8201, CVE-2020-8252, CVE-2020-8265, and CVE-2020-8287 have been assigned to these vulnerabilities in open-source components used by FCP. A CVSS v3 base score of 8.1 has been calculated for the worst case; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-1968" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8172" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8174" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8201" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8252" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8265" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8287" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "For FCP 1.1.0 - 1.3.0, FCP 2.1.0 - 2.3.0, FCP 3.0.0 - 3.12.0: Users should apply mitigations listed in this advisory and in the mitigation section of Hitachi Energy advisory 8DBD000104.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000104" }, { "category": "vendor_fix", "details": "A remediated version FCP 3.14.0 and 4.0.0 is planned. For update or upgrades, users should contact Hitachi Energy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://www.hitachienergy.com/contact-us/" }, { "category": "mitigation", "details": "Physically protect process control systems from unauthorized direct access.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Separate process control systems from other networks using firewall system that has a minimal number of ports open.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Process control systems should not be used for internet surfing, instant messaging, or receiving emails.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "Portable computers and removable storage media should be carefully scanned for viruses connecting to a control system", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] }, { "category": "mitigation", "details": "For more information, see Hitachi Energy advisory 8DBD000104.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000104" } ], "scores": [ { "cvss_v3": { "baseScore": 8.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003" ] } ] } ] }
icsa-22-242-02
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Hitachi Energy", "summary": "reporting to CISA that GWS was affected by these previously discovered vulnerabilities in open-source software components" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of this vulnerability could allow unauthorized users to eavesdrop on the traffic between network source and destination, gain unauthorized access to information, or cause a denial-of service condition.", "title": "Risk evaluation" }, { "category": "other", "text": "Energy", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Switzerland", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/icsSeveral recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov/icsin the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are exploitable remotely. These vulnerabilities have a low attack complexity.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-22-242-02 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-242-02.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-242-02 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-242-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-242-02" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Hitachi Energy Gateway Station (GWS) Product", "tracking": { "current_release_date": "2022-08-30T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-242-02", "initial_release_date": "2022-08-30T00:00:00.000000Z", "revision_history": [ { "date": "2022-08-30T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version", "name": "3.1.0.0", "product": { "name": "GWS: 3.1.0.0", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "GWS" }, { "branches": [ { "category": "product_version_range", "name": "\u003c= 2.0.0.0", "product": { "name": "GWS: 2.0.0.0 and earlier", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "GWS" }, { "branches": [ { "category": "product_version", "name": "2.2.0.0", "product": { "name": "GWS: 2.2.0.0", "product_id": "CSAFPID-0003" } } ], "category": "product_name", "name": "GWS" }, { "branches": [ { "category": "product_version", "name": "2.3.0.0", "product": { "name": "GWS: 2.3.0.0", "product_id": "CSAFPID-0004" } } ], "category": "product_name", "name": "GWS" }, { "branches": [ { "category": "product_version", "name": "2.1.0.0", "product": { "name": "GWS: 2.1.0.0", "product_id": "CSAFPID-0005" } } ], "category": "product_name", "name": "GWS" }, { "branches": [ { "category": "product_version", "name": "3.0.0.0", "product": { "name": "GWS: 3.0.0.0", "product_id": "CSAFPID-0006" } } ], "category": "product_name", "name": "GWS" }, { "branches": [ { "category": "product_version", "name": "2.4.0.0", "product": { "name": "GWS: 2.4.0.0", "product_id": "CSAFPID-0007" } } ], "category": "product_name", "name": "GWS" } ], "category": "vendor", "name": "Hitachi Energy" } ] }, "vulnerabilities": [ { "cve": "CVE-2020-1968", "cwe": { "id": "CWE-1357", "name": "Reliance on Insufficiently Trustworthy Component" }, "notes": [ { "category": "summary", "text": "Hitachi Energy is aware of publicly disclosed reports of multiple vulnerabilities in open-source software components (OpenSSL and Node.JS) used in the Gateway Station (GWS) product. Versions are available to remediate the identified vulnerabilities.CVE-2020-1968, CVE-2020-8172, CVE-2020-8174, CVE-2020-8201, CVE-2020-8252, CVE-2020-8265, and CVE-2020-8287 have been assigned to these vulnerabilities in open source components used by GWS. A CVSS v3 base score of 8.1 has been calculated for the worst case; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H).\n", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-1968" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8172" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8174" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8201" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8252" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8265" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-8287" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "GWS 2.0.0.0 and earlier, GWS 2.1.0.0, GWS 2.2.0.0, GWS 2.3.0.0, GWS 2.4.0.0,GWS 3.0.0.0, GWS 3.1.0.0: Apply the mitigation factors as described in this advisory and in the mitigation section of Hitachi Energy advisory 8DBD000101.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000101" }, { "category": "vendor_fix", "details": "A remediated version of GWS 3.2.0.0 is planned. For updates or upgrades, contact Hitachi Energy.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007" ], "url": "https://www.hitachienergy.com/contact-us/" }, { "category": "mitigation", "details": "Physically protect process control systems from unauthorized direct access.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007" ] }, { "category": "mitigation", "details": "Separate process control systems from other networks using a firewall system with only the necessary ports open.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007" ] }, { "category": "mitigation", "details": "Process control systems should not be used for internet surfing, instant messaging, or receiving emails.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007" ] }, { "category": "mitigation", "details": "Portable computers and removable storage media should be carefully scanned for viruses before connecting to a control system.", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007" ] }, { "category": "mitigation", "details": "For more information, see Hitachi security advisory 8DBD000101", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000101" } ], "scores": [ { "cvss_v3": { "baseScore": 8.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001", "CSAFPID-0002", "CSAFPID-0003", "CSAFPID-0004", "CSAFPID-0005", "CSAFPID-0006", "CSAFPID-0007" ] } ] } ] }
icsa-22-116-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Hitachi Energy", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities could allow an attacker to eavesdrop on traffic or to cause a denial-of-service condition.", "title": "Risk evaluation" }, { "category": "other", "text": "Energy", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Switzerland", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "ICS Advisory ICSA-22-116-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-116-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-116-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-116-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Hitachi Energy System Data Manager", "tracking": { "current_release_date": "2022-04-26T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-116-01", "initial_release_date": "2022-04-26T00:00:00.000000Z", "revision_history": [ { "date": "2022-04-26T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-22-116-01 Hitachi Energy System Data Manager" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c1.2 FP2 HF10 (Build Nr. 1.2.14002.506) ", "product": { "name": "All System Data Manager - SDM600: versions prior to version 1.2 FP2 HF10 (Build Nr. 1.2.14002.506)", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "All System Data Manager - SDM600" } ], "category": "vendor", "name": "Hitachi Energy" } ] }, "vulnerabilities": [ { "cve": "CVE-2020-1968", "cwe": { "id": "CWE-203", "name": "Observable Discrepancy" }, "notes": [ { "category": "summary", "text": "In affected OpenSSL versions, the Raccoon attack exploits a flaw in the TLS specification that can lead to an attacker computing the pre-master secret in connections that have used a Diffie-Hellman-based ciphersuite. This allows the attacker to eavesdrop on all encrypted communications sent over that TLS connection.CVE-2020-1968 has been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-1968" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N" } ], "remediations": [ { "category": "mitigation", "details": "The vulnerabilities are remediated as of the following product Version SDM600 Version 1.2 FP2 HF10 (Build Nr. 1.2.14002.506). Hitachi Energy recommends users apply the update at the earliest convenience from the SDM600 product website.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.hitachiabb-powergrids.com/ch/en/offering/product-and-system/scada/microscada-x/sdm600" }, { "category": "mitigation", "details": "Implement and continuously revise least privileges principles to minimize permissions and accesses to SDM600 related resources.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Follow security practices as defined in SDM600 security deployment guideline and firewall configurations to help protect process control networks from attacks that originate from outside the network. Such practices include that process control systems are: Physically protected from direct access by unauthorized personnel. Not directly connected to the Internet. Separated from other networks by means of a firewall system that has a minimal number of ports exposed. Not used for Internet surfing instant messaging or receiving e-mails.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Carefully scan portable computers and removable storage media for viruses before connecting to a control system.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For additional information, see the Hitachi Energy security advisory.", "product_ids": [ "CSAFPID-0001" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000074\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 3.7, "baseSeverity": "LOW", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2020-12243", "cwe": { "id": "CWE-674", "name": "Uncontrolled Recursion" }, "notes": [ { "category": "summary", "text": "In affected versions of OpenLDAP, LDAP search filters with nested boolean expressions can result in a denial-of-service condition.CVE-2020-12243 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-12243" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "The vulnerabilities are remediated as of the following product Version SDM600 Version 1.2 FP2 HF10 (Build Nr. 1.2.14002.506). Hitachi Energy recommends users apply the update at the earliest convenience from the SDM600 product website.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.hitachiabb-powergrids.com/ch/en/offering/product-and-system/scada/microscada-x/sdm600" }, { "category": "mitigation", "details": "Implement and continuously revise least privileges principles to minimize permissions and accesses to SDM600 related resources.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Follow security practices as defined in SDM600 security deployment guideline and firewall configurations to help protect process control networks from attacks that originate from outside the network. Such practices include that process control systems are: Physically protected from direct access by unauthorized personnel. Not directly connected to the Internet. Separated from other networks by means of a firewall system that has a minimal number of ports exposed. Not used for Internet surfing instant messaging or receiving e-mails.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Carefully scan portable computers and removable storage media for viruses before connecting to a control system.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For additional information, see the Hitachi Energy security advisory.", "product_ids": [ "CSAFPID-0001" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000074\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2020-25709", "cwe": { "id": "CWE-617", "name": "Reachable Assertion" }, "notes": [ { "category": "summary", "text": "A flaw in affected versions of the OpenLDAP slapd server may cause an assertion failure when processing a malicious packet. This may lead to a denial-of-service condition.CVE-2020-25709 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-25709" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "The vulnerabilities are remediated as of the following product Version SDM600 Version 1.2 FP2 HF10 (Build Nr. 1.2.14002.506). Hitachi Energy recommends users apply the update at the earliest convenience from the SDM600 product website.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.hitachiabb-powergrids.com/ch/en/offering/product-and-system/scada/microscada-x/sdm600" }, { "category": "mitigation", "details": "Implement and continuously revise least privileges principles to minimize permissions and accesses to SDM600 related resources.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Follow security practices as defined in SDM600 security deployment guideline and firewall configurations to help protect process control networks from attacks that originate from outside the network. Such practices include that process control systems are: Physically protected from direct access by unauthorized personnel. Not directly connected to the Internet. Separated from other networks by means of a firewall system that has a minimal number of ports exposed. Not used for Internet surfing instant messaging or receiving e-mails.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Carefully scan portable computers and removable storage media for viruses before connecting to a control system.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For additional information, see the Hitachi Energy security advisory.", "product_ids": [ "CSAFPID-0001" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000074\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2020-25710", "cwe": { "id": "CWE-617", "name": "Reachable Assertion" }, "notes": [ { "category": "summary", "text": "A flaw in affected versions of OpenLDAP allows an attacker who sends a malicious packet processed by OpenLDAP to force a failed assertion in csnNormalize23() function. This may lead to a denial-of-service condition.CVE-2020-25710 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-25710" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "The vulnerabilities are remediated as of the following product Version SDM600 Version 1.2 FP2 HF10 (Build Nr. 1.2.14002.506). Hitachi Energy recommends users apply the update at the earliest convenience from the SDM600 product website.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.hitachiabb-powergrids.com/ch/en/offering/product-and-system/scada/microscada-x/sdm600" }, { "category": "mitigation", "details": "Implement and continuously revise least privileges principles to minimize permissions and accesses to SDM600 related resources.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Follow security practices as defined in SDM600 security deployment guideline and firewall configurations to help protect process control networks from attacks that originate from outside the network. Such practices include that process control systems are: Physically protected from direct access by unauthorized personnel. Not directly connected to the Internet. Separated from other networks by means of a firewall system that has a minimal number of ports exposed. Not used for Internet surfing instant messaging or receiving e-mails.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Carefully scan portable computers and removable storage media for viruses before connecting to a control system.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For additional information, see the Hitachi Energy security advisory.", "product_ids": [ "CSAFPID-0001" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000074\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2020-36229", "cwe": { "id": "CWE-843", "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)" }, "notes": [ { "category": "summary", "text": "A flaw was discovered in ldap_X509dn2bv in affected OpenLDAP versions leading to a slapd crash in the X.509 DN parsing in ad_keystring, resulting in a denial-of-service condition.CVE-2020-36229 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-36229" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "The vulnerabilities are remediated as of the following product Version SDM600 Version 1.2 FP2 HF10 (Build Nr. 1.2.14002.506). Hitachi Energy recommends users apply the update at the earliest convenience from the SDM600 product website.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.hitachiabb-powergrids.com/ch/en/offering/product-and-system/scada/microscada-x/sdm600" }, { "category": "mitigation", "details": "Implement and continuously revise least privileges principles to minimize permissions and accesses to SDM600 related resources.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Follow security practices as defined in SDM600 security deployment guideline and firewall configurations to help protect process control networks from attacks that originate from outside the network. Such practices include that process control systems are: Physically protected from direct access by unauthorized personnel. Not directly connected to the Internet. Separated from other networks by means of a firewall system that has a minimal number of ports exposed. Not used for Internet surfing instant messaging or receiving e-mails.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Carefully scan portable computers and removable storage media for viruses before connecting to a control system.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For additional information, see the Hitachi Energy security advisory.", "product_ids": [ "CSAFPID-0001" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000074\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2020-36230", "cwe": { "id": "CWE-617", "name": "Reachable Assertion" }, "notes": [ { "category": "summary", "text": "A flaw was discovered in affected OpenLDAP versions leading in an assertion failure in slapd in the X.509 DN parsing in decode.c ber_next_element, resulting in a denial-of-service condition.CVE-2020-36230 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-36230" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "The vulnerabilities are remediated as of the following product Version SDM600 Version 1.2 FP2 HF10 (Build Nr. 1.2.14002.506). Hitachi Energy recommends users apply the update at the earliest convenience from the SDM600 product website.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.hitachiabb-powergrids.com/ch/en/offering/product-and-system/scada/microscada-x/sdm600" }, { "category": "mitigation", "details": "Implement and continuously revise least privileges principles to minimize permissions and accesses to SDM600 related resources.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Follow security practices as defined in SDM600 security deployment guideline and firewall configurations to help protect process control networks from attacks that originate from outside the network. Such practices include that process control systems are: Physically protected from direct access by unauthorized personnel. Not directly connected to the Internet. Separated from other networks by means of a firewall system that has a minimal number of ports exposed. Not used for Internet surfing instant messaging or receiving e-mails.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Carefully scan portable computers and removable storage media for viruses before connecting to a control system.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For additional information, see the Hitachi Energy security advisory.", "product_ids": [ "CSAFPID-0001" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000074\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] }, { "cve": "CVE-2021-23840", "cwe": { "id": "CWE-190", "name": "Integer Overflow or Wraparound" }, "notes": [ { "category": "summary", "text": "A flaw in affected versions of OpenSSL may cause calls to EVP_CipherUpdate, EVP_EncryptUpdate and EVP_DecryptUpdate to overflow the output length argument in some cases where the input length is close to the maximum permissible length for an integer on the platform. This could lead to applications behaving incorrectly.CVE-2021-23840 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H).", "title": "Vulnerability Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-23840" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H" } ], "remediations": [ { "category": "mitigation", "details": "The vulnerabilities are remediated as of the following product Version SDM600 Version 1.2 FP2 HF10 (Build Nr. 1.2.14002.506). Hitachi Energy recommends users apply the update at the earliest convenience from the SDM600 product website.", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.hitachiabb-powergrids.com/ch/en/offering/product-and-system/scada/microscada-x/sdm600" }, { "category": "mitigation", "details": "Implement and continuously revise least privileges principles to minimize permissions and accesses to SDM600 related resources.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Follow security practices as defined in SDM600 security deployment guideline and firewall configurations to help protect process control networks from attacks that originate from outside the network. Such practices include that process control systems are: Physically protected from direct access by unauthorized personnel. Not directly connected to the Internet. Separated from other networks by means of a firewall system that has a minimal number of ports exposed. Not used for Internet surfing instant messaging or receiving e-mails.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "Carefully scan portable computers and removable storage media for viruses before connecting to a control system.", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "For additional information, see the Hitachi Energy security advisory.", "product_ids": [ "CSAFPID-0001" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000074\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "scores": [ { "cvss_v3": { "baseScore": 7.5, "baseSeverity": "HIGH", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, "products": [ "CSAFPID-0001" ] } ] } ] }
gsd-2020-1968
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2020-1968", "description": "The Raccoon attack exploits a flaw in the TLS specification which can lead to an attacker being able to compute the pre-master secret in connections which have used a Diffie-Hellman (DH) based ciphersuite. In such a case this would result in the attacker being able to eavesdrop on all encrypted communications sent over that TLS connection. The attack can only be exploited if an implementation re-uses a DH secret across multiple TLS connections. Note that this issue only impacts DH ciphersuites and not ECDH ciphersuites. This issue affects OpenSSL 1.0.2 which is out of support and no longer receiving public updates. OpenSSL 1.1.1 is not vulnerable to this issue. Fixed in OpenSSL 1.0.2w (Affected 1.0.2-1.0.2v).", "id": "GSD-2020-1968", "references": [ "https://www.suse.com/security/cve/CVE-2020-1968.html", "https://ubuntu.com/security/CVE-2020-1968", "https://advisories.mageia.org/CVE-2020-1968.html", "https://security.archlinux.org/CVE-2020-1968" ] }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2020-1968" ], "details": "The Raccoon attack exploits a flaw in the TLS specification which can lead to an attacker being able to compute the pre-master secret in connections which have used a Diffie-Hellman (DH) based ciphersuite. In such a case this would result in the attacker being able to eavesdrop on all encrypted communications sent over that TLS connection. The attack can only be exploited if an implementation re-uses a DH secret across multiple TLS connections. Note that this issue only impacts DH ciphersuites and not ECDH ciphersuites. This issue affects OpenSSL 1.0.2 which is out of support and no longer receiving public updates. OpenSSL 1.1.1 is not vulnerable to this issue. Fixed in OpenSSL 1.0.2w (Affected 1.0.2-1.0.2v).", "id": "GSD-2020-1968", "modified": "2023-12-13T01:21:58.750088Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "openssl-security@openssl.org", "DATE_PUBLIC": "2020-09-09", "ID": "CVE-2020-1968", "STATE": "PUBLIC", "TITLE": "Raccoon attack" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "OpenSSL", "version": { "version_data": [ { "version_value": "Fixed in OpenSSL 1.0.2w (Affected 1.0.2-1.0.2v)" } ] } } ] }, "vendor_name": "OpenSSL" } ] } }, "credit": [ { "lang": "eng", "value": "Robert Merget, Marcus Brinkmann, Nimrod Aviram, and Juraj Somorovsky" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "The Raccoon attack exploits a flaw in the TLS specification which can lead to an attacker being able to compute the pre-master secret in connections which have used a Diffie-Hellman (DH) based ciphersuite. In such a case this would result in the attacker being able to eavesdrop on all encrypted communications sent over that TLS connection. The attack can only be exploited if an implementation re-uses a DH secret across multiple TLS connections. Note that this issue only impacts DH ciphersuites and not ECDH ciphersuites. This issue affects OpenSSL 1.0.2 which is out of support and no longer receiving public updates. OpenSSL 1.1.1 is not vulnerable to this issue. Fixed in OpenSSL 1.0.2w (Affected 1.0.2-1.0.2v)." } ] }, "impact": [ { "lang": "eng", "url": "https://www.openssl.org/policies/secpolicy.html#Low", "value": "Low" } ], "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "Protocol flaw" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.openssl.org/news/secadv/20200909.txt", "refsource": "CONFIRM", "url": "https://www.openssl.org/news/secadv/20200909.txt" }, { "name": "USN-4504-1", "refsource": "UBUNTU", "url": "https://usn.ubuntu.com/4504-1/" }, { "name": "[debian-lts-announce] 20200925 [SECURITY] [DLA 2378-1] openssl1.0 security update", "refsource": "MLIST", "url": "https://lists.debian.org/debian-lts-announce/2020/09/msg00016.html" }, { "name": "https://www.oracle.com/security-alerts/cpujan2021.html", "refsource": "MISC", "url": "https://www.oracle.com/security-alerts/cpujan2021.html" }, { "name": "https://security.netapp.com/advisory/ntap-20200911-0004/", "refsource": "CONFIRM", "url": "https://security.netapp.com/advisory/ntap-20200911-0004/" }, { "name": "https://www.oracle.com/security-alerts/cpuApr2021.html", "refsource": "MISC", "url": "https://www.oracle.com/security-alerts/cpuApr2021.html" }, { "name": "https://www.oracle.com//security-alerts/cpujul2021.html", "refsource": "MISC", "url": "https://www.oracle.com//security-alerts/cpujul2021.html" }, { "name": "https://www.oracle.com/security-alerts/cpuoct2021.html", "refsource": "MISC", "url": "https://www.oracle.com/security-alerts/cpuoct2021.html" }, { "name": "https://www.oracle.com/security-alerts/cpuapr2022.html", "refsource": "MISC", "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" }, { "name": "GLSA-202210-02", "refsource": "GENTOO", "url": "https://security.gentoo.org/glsa/202210-02" } ] } }, "gitlab.com": { "advisories": [ { "affected_range": "\u003e=1.0.2 \u003c=1.0.2v", "affected_versions": "All versions starting from 1.0.2 up to 1.0.2v", "cvss_v2": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "cvss_v3": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N", "cwe_ids": [ "CWE-1035", "CWE-203", "CWE-937" ], "date": "2021-12-10", "description": "The Raccoon attack exploits a flaw in the TLS specification which can lead to an attacker being able to compute the pre-master secret in connections which have used a Diffie-Hellman (DH) based ciphersuite.", "fixed_versions": [ "1.1.0k" ], "identifier": "CVE-2020-1968", "identifiers": [ "CVE-2020-1968" ], "not_impacted": "All versions before 1.0.2, all versions after 1.0.2v", "package_slug": "conan/openssl", "pubdate": "2020-09-09", "solution": "Upgrade to version 1.1.0k or above.", "title": "Inadequate Encryption Strength", "urls": [ "https://nvd.nist.gov/vuln/detail/CVE-2020-1968", "https://www.openssl.org/news/secadv/20200909.txt" ], "uuid": "13959894-f2e3-4813-9124-872318d54849" } ] }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:openssl:openssl:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "1.0.2v", "versionStartIncluding": "1.0.2", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:canonical:ubuntu_linux:16.04:*:*:*:lts:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:canonical:ubuntu_linux:18.04:*:*:*:lts:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:debian:debian_linux:9.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.56:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.57:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:oracle:jd_edwards_world_security:a9.4:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:oracle:peoplesoft_enterprise_peopletools:8.58:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:oracle:ethernet_switch_es2-64_firmware:2.0.0.14:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:oracle:ethernet_switch_es2-64:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:oracle:ethernet_switch_es2-72_firmware:2.0.0.14:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:oracle:ethernet_switch_es2-72:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:fujitsu:m10-1_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "xcp2400", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:fujitsu:m10-1:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:fujitsu:m10-4_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "xcp2400", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:fujitsu:m10-4:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:fujitsu:m10-4s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "xcp2400", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:fujitsu:m10-4s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:fujitsu:m12-1_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "xcp2400", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:fujitsu:m12-1:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:fujitsu:m12-2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "xcp2400", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:fujitsu:m12-2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:fujitsu:m12-2s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "xcp2400", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:fujitsu:m12-2s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:fujitsu:m10-1_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "xcp3100", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:fujitsu:m10-1:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:fujitsu:m10-4_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "xcp3100", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:fujitsu:m10-4:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:fujitsu:m10-4s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "xcp3100", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:fujitsu:m10-4s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:fujitsu:m12-1_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "xcp3100", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:fujitsu:m12-1:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:fujitsu:m12-2_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "xcp3100", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:fujitsu:m12-2:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:fujitsu:m12-2s_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "xcp3100", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:fujitsu:m12-2s:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:oracle:ethernet_switch_es1-24_firmware:1.3.1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:oracle:ethernet_switch_es1-24:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:oracle:ethernet_switch_tor-72_firmware:1.2.2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:oracle:ethernet_switch_tor-72:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "openssl-security@openssl.org", "ID": "CVE-2020-1968" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "The Raccoon attack exploits a flaw in the TLS specification which can lead to an attacker being able to compute the pre-master secret in connections which have used a Diffie-Hellman (DH) based ciphersuite. In such a case this would result in the attacker being able to eavesdrop on all encrypted communications sent over that TLS connection. The attack can only be exploited if an implementation re-uses a DH secret across multiple TLS connections. Note that this issue only impacts DH ciphersuites and not ECDH ciphersuites. This issue affects OpenSSL 1.0.2 which is out of support and no longer receiving public updates. OpenSSL 1.1.1 is not vulnerable to this issue. Fixed in OpenSSL 1.0.2w (Affected 1.0.2-1.0.2v)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-203" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.openssl.org/news/secadv/20200909.txt", "refsource": "CONFIRM", "tags": [ "Vendor Advisory" ], "url": "https://www.openssl.org/news/secadv/20200909.txt" }, { "name": "https://security.netapp.com/advisory/ntap-20200911-0004/", "refsource": "CONFIRM", "tags": [ "Third Party Advisory" ], "url": "https://security.netapp.com/advisory/ntap-20200911-0004/" }, { "name": "USN-4504-1", "refsource": "UBUNTU", "tags": [ "Third Party Advisory" ], "url": "https://usn.ubuntu.com/4504-1/" }, { "name": "[debian-lts-announce] 20200925 [SECURITY] [DLA 2378-1] openssl1.0 security update", "refsource": "MLIST", "tags": [ "Mailing List", "Third Party Advisory" ], "url": "https://lists.debian.org/debian-lts-announce/2020/09/msg00016.html" }, { "name": "https://www.oracle.com/security-alerts/cpujan2021.html", "refsource": "MISC", "tags": [ "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpujan2021.html" }, { "name": "https://www.oracle.com/security-alerts/cpuApr2021.html", "refsource": "MISC", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpuApr2021.html" }, { "name": "N/A", "refsource": "N/A", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://www.oracle.com//security-alerts/cpujul2021.html" }, { "name": "https://www.oracle.com/security-alerts/cpuoct2021.html", "refsource": "MISC", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpuoct2021.html" }, { "name": "https://www.oracle.com/security-alerts/cpuapr2022.html", "refsource": "MISC", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" }, { "name": "GLSA-202210-02", "refsource": "GENTOO", "tags": [ "Third Party Advisory" ], "url": "https://security.gentoo.org/glsa/202210-02" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "NONE", "baseScore": 4.3, "confidentialityImpact": "PARTIAL", "integrityImpact": "NONE", "vectorString": "AV:N/AC:M/Au:N/C:P/I:N/A:N", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 2.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": false }, "baseMetricV3": { "cvssV3": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 3.7, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 1.4 } }, "lastModifiedDate": "2022-11-21T19:48Z", "publishedDate": "2020-09-09T14:15Z" } } }
wid-sec-w-2022-1723
Vulnerability from csaf_certbund
Notes
{ "document": { "aggregate_severity": { "text": "hoch" }, "category": "csaf_base", "csaf_version": "2.0", "distribution": { "tlp": { "label": "WHITE", "url": "https://www.first.org/tlp/" } }, "lang": "de-DE", "notes": [ { "category": "legal_disclaimer", "text": "Das BSI ist als Anbieter f\u00fcr die eigenen, zur Nutzung bereitgestellten Inhalte nach den allgemeinen Gesetzen verantwortlich. Nutzerinnen und Nutzer sind jedoch daf\u00fcr verantwortlich, die Verwendung und/oder die Umsetzung der mit den Inhalten bereitgestellten Informationen sorgf\u00e4ltig im Einzelfall zu pr\u00fcfen." }, { "category": "description", "text": "Transport Layer Security (TLS) ist ein hybrides Verschl\u00fcsselungsprotokoll zur Daten\u00fcbertragung im Internet.", "title": "Produktbeschreibung" }, { "category": "summary", "text": "Ein entfernter, anonymer Angreifer kann mehrere Schwachstellen in TLS 1.2 ausnutzen, um Sicherheitsvorkehrungen zu umgehen.", "title": "Angriff" }, { "category": "general", "text": "- Android\n- F5 Networks\n- iPhoneOS\n- Linux\n- MacOS X\n- Sonstiges\n- UNIX\n- Windows", "title": "Betroffene Betriebssysteme" } ], "publisher": { "category": "other", "contact_details": "csaf-provider@cert-bund.de", "name": "Bundesamt f\u00fcr Sicherheit in der Informationstechnik", "namespace": "https://www.bsi.bund.de" }, "references": [ { "category": "self", "summary": "WID-SEC-W-2022-1723 - CSAF Version", "url": "https://wid.cert-bund.de/.well-known/csaf/white/2020/wid-sec-w-2022-1723.json" }, { "category": "self", "summary": "WID-SEC-2022-1723 - Portal Version", "url": "https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2022-1723" }, { "category": "external", "summary": "Meldung von raccoon-attack.com/ vom 2020-09-09", "url": "https://raccoon-attack.com/" }, { "category": "external", "summary": "F5 Security Advisory K91158923 vom 2020-09-09", "url": "https://support.f5.com/csp/article/K91158923" }, { "category": "external", "summary": "OpenSSL Security Advisory vom 2020-09-09", "url": "https://www.openssl.org/news/secadv/20200909.txt" }, { "category": "external", "summary": "NetApp Security Advisory NTAP-20200911-0004 vom 2020-09-11", "url": "https://security.netapp.com/advisory/ntap-20200911-0004/" }, { "category": "external", "summary": "SUSE Security Update SUSE-SU-2020:2634-1 vom 2020-09-15", "url": "http://lists.suse.com/pipermail/sle-security-updates/2020-September/007427.html" }, { "category": "external", "summary": "SUSE Security Update SUSE-SU-2020:14491-1 vom 2020-09-15", "url": "http://lists.suse.com/pipermail/sle-security-updates/2020-September/007429.html" }, { "category": "external", "summary": "Ubuntu Security Notice USN-4504-1 vom 2020-09-16", "url": "https://usn.ubuntu.com/4504-1/" }, { "category": "external", "summary": "Debian Security Advisory DLA-2378 vom 2020-09-26", "url": "https://lists.debian.org/debian-lts-announce/2020/debian-lts-announce-202009/msg00016.html" }, { "category": "external", "summary": "SUSE Security Update SUSE-SU-2020:14511-1 vom 2020-10-05", "url": "http://lists.suse.com/pipermail/sle-security-updates/2020-October/007521.html" }, { "category": "external", "summary": "XEROX Security Advisory XRX21-008 vom 2021-05-19", "url": "https://securitydocs.business.xerox.com/wp-content/uploads/2021/05/cert_XRX21-008_FFPSv7-S10_DvdUsb-Bulletin_May2021.pdf" }, { "category": "external", "summary": "XEROX Security Advisory XRX21-009 vom 2021-05-19", "url": "https://securitydocs.business.xerox.com/wp-content/uploads/2021/05/cert_XRX21-009_FFPSv9-S10_DvdUsb-Bulletin_May2021.pdf" }, { "category": "external", "summary": "F5 Security Advisory K92451315 vom 2020-12-11", "url": "https://support.f5.com/csp/article/K92451315" }, { "category": "external", "summary": "Palo Alto Networks Security Advisory PAN-154936 vom 2021-10-13", "url": "https://security.paloaltonetworks.com/CVE-2020-1968" }, { "category": "external", "summary": "Hitachi Cybersecurity Advisory", "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000064\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" }, { "category": "external", "summary": "Gentoo Linux Security Advisory GLSA-202210-02 vom 2022-10-16", "url": "https://security.gentoo.org/glsa/202210-02" }, { "category": "external", "summary": "Dell Knowledge Base Article", "url": "https://www.dell.com/support/kbdoc/en-us/000221474/dsa-2024-059-security-update-for-dell-networker-multiple-components-vulnerabilities" }, { "category": "external", "summary": "IBM Security Bulletin 7056034 vom 2023-10-19", "url": "https://www.ibm.com/support/pages/node/7056034" }, { "category": "external", "summary": "IBM Security Bulletin 7145367 vom 2024-03-27", "url": "https://www.ibm.com/support/pages/node/7145367" } ], "source_lang": "en-US", "title": "TLS: Mehrere Schwachstellen erm\u00f6glichen Umgehen von Sicherheitsvorkehrungen", "tracking": { "current_release_date": "2024-03-27T23:00:00.000+00:00", "generator": { "date": "2024-03-28T09:37:26.691+00:00", "engine": { "name": "BSI-WID", "version": "1.3.0" } }, "id": "WID-SEC-W-2022-1723", "initial_release_date": "2020-09-09T22:00:00.000+00:00", "revision_history": [ { "date": "2020-09-09T22:00:00.000+00:00", "number": "1", "summary": "Initiale Fassung" }, { "date": "2020-09-13T22:00:00.000+00:00", "number": "2", "summary": "Neue Updates von NetApp aufgenommen" }, { "date": "2020-09-15T22:00:00.000+00:00", "number": "3", "summary": "Neue Updates von SUSE aufgenommen" }, { "date": "2020-09-16T22:00:00.000+00:00", "number": "4", "summary": "Neue Updates von Ubuntu aufgenommen" }, { "date": "2020-09-27T22:00:00.000+00:00", "number": "5", "summary": "Neue Updates von Debian aufgenommen" }, { "date": "2020-10-05T22:00:00.000+00:00", "number": "6", "summary": "Neue Updates von SUSE aufgenommen" }, { "date": "2020-12-10T23:00:00.000+00:00", "number": "7", "summary": "Neue Updates von F5 aufgenommen" }, { "date": "2021-05-19T22:00:00.000+00:00", "number": "8", "summary": "Neue Updates von XEROX aufgenommen" }, { "date": "2021-10-13T22:00:00.000+00:00", "number": "9", "summary": "Neue Updates von Palo Alto Networks aufgenommen" }, { "date": "2021-12-02T23:00:00.000+00:00", "number": "10", "summary": "Neue Updates aufgenommen" }, { "date": "2022-10-16T22:00:00.000+00:00", "number": "11", "summary": "Neue Updates von Gentoo aufgenommen" }, { "date": "2023-10-19T22:00:00.000+00:00", "number": "12", "summary": "Neue Updates von IBM aufgenommen" }, { "date": "2024-01-25T23:00:00.000+00:00", "number": "13", "summary": "Neue Updates von Dell aufgenommen" }, { "date": "2024-03-27T23:00:00.000+00:00", "number": "14", "summary": "Neue Updates von IBM aufgenommen" } ], "status": "final", "version": "14" } }, "product_tree": { "branches": [ { "branches": [ { "category": "product_name", "name": "Debian Linux", "product": { "name": "Debian Linux", "product_id": "2951", "product_identification_helper": { "cpe": "cpe:/o:debian:debian_linux:-" } } } ], "category": "vendor", "name": "Debian" }, { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 19.10", "product": { "name": "Dell NetWorker \u003c 19.10", "product_id": "T032354", "product_identification_helper": { "cpe": "cpe:/a:dell:networker:19.10" } } } ], "category": "product_name", "name": "NetWorker" } ], "category": "vendor", "name": "Dell" }, { "branches": [ { "category": "product_name", "name": "F5 BIG-IP", "product": { "name": "F5 BIG-IP", "product_id": "T001663", "product_identification_helper": { "cpe": "cpe:/a:f5:big-ip:-" } } } ], "category": "vendor", "name": "F5" }, { "branches": [ { "category": "product_name", "name": "Gentoo Linux", "product": { "name": "Gentoo Linux", "product_id": "T012167", "product_identification_helper": { "cpe": "cpe:/o:gentoo:linux:-" } } } ], "category": "vendor", "name": "Gentoo" }, { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 7.5.0 UP8", "product": { "name": "IBM QRadar SIEM \u003c 7.5.0 UP8", "product_id": "T033681", "product_identification_helper": { "cpe": "cpe:/a:ibm:qradar_siem:7.5.0_up8" } } } ], "category": "product_name", "name": "QRadar SIEM" }, { "branches": [ { "category": "product_version_range", "name": "\u003c 8.0.0.24", "product": { "name": "IBM Rational Build Forge \u003c 8.0.0.24", "product_id": "T030689", "product_identification_helper": { "cpe": "cpe:/a:ibm:rational_build_forge:8.0.0.24" } } } ], "category": "product_name", "name": "Rational Build Forge" } ], "category": "vendor", "name": "IBM" }, { "branches": [ { "category": "product_name", "name": "NetApp Data ONTAP", "product": { "name": "NetApp Data ONTAP", "product_id": "7654", "product_identification_helper": { "cpe": "cpe:/a:netapp:data_ontap:-" } } } ], "category": "vendor", "name": "NetApp" }, { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c 1.0.2w", "product": { "name": "Open Source OpenSSL \u003c 1.0.2w", "product_id": "8269", "product_identification_helper": { "cpe": "cpe:/a:openssl:openssl:-" } } } ], "category": "product_name", "name": "OpenSSL" }, { "category": "product_name", "name": "Specification TLS", "product": { "name": "Specification TLS", "product_id": "T017244", "product_identification_helper": { "cpe": "cpe:/a:open_source:tls1:-" } } } ], "category": "vendor", "name": "Open Source" }, { "branches": [ { "category": "product_name", "name": "SUSE Linux", "product": { "name": "SUSE Linux", "product_id": "T002207", "product_identification_helper": { "cpe": "cpe:/o:suse:suse_linux:-" } } } ], "category": "vendor", "name": "SUSE" }, { "branches": [ { "category": "product_name", "name": "Ubuntu Linux", "product": { "name": "Ubuntu Linux", "product_id": "T000126", "product_identification_helper": { "cpe": "cpe:/o:canonical:ubuntu_linux:-" } } } ], "category": "vendor", "name": "Ubuntu" }, { "branches": [ { "branches": [ { "category": "product_version", "name": "7", "product": { "name": "Xerox FreeFlow Print Server 7", "product_id": "T000872", "product_identification_helper": { "cpe": "cpe:/a:xerox:freeflow_print_server:7" } } } ], "category": "product_name", "name": "FreeFlow Print Server" } ], "category": "vendor", "name": "Xerox" } ] }, "vulnerabilities": [ { "cve": "CVE-2020-12413", "notes": [ { "category": "description", "text": "In der Spezifikation von TLS 1.2 oder fr\u00fcher existiert eine Schwachstelle. Sie beruht darauf, dass bei Verwendung des Diffie-Hellman (DH) Schl\u00fcsselaustauschalgorithmus bei der Erzeugung des Premaster-Secrets die Ergebnisse des Schl\u00fcsselaustauschs gehasht und hierbei zun\u00e4chst die f\u00fchrenden Nullen entfernt werden. Ein Angreifer in einer Man-in-the-Middle Position kann dieses messen. Au\u00dferdem muss der Server so konfiguriert sein, dass er statische TLS-DH-Verschl\u00fcsselungssuiten verwendet oder der Server muss kurzlebige Verschl\u00fcsselungssuiten (TLS-DHE) verwenden und die Schl\u00fcssel f\u00fcr mehrere Verbindungen wiederverwenden. Durch Manipulation und mehrfaches Versenden der abgefangenen Daten kann der Angreifer dann m\u00f6glicherweise den Schl\u00fcssel erlangen." } ], "product_status": { "known_affected": [ "T017244", "2951", "T002207", "T000126", "7654", "T030689", "T000872", "T001663", "T033681", "T012167", "T032354" ] }, "release_date": "2020-09-09T22:00:00Z", "title": "CVE-2020-12413" }, { "cve": "CVE-2020-1968", "notes": [ { "category": "description", "text": "In der Spezifikation von TLS 1.2 oder fr\u00fcher existiert eine Schwachstelle. Sie beruht darauf, dass bei Verwendung des Diffie-Hellman (DH) Schl\u00fcsselaustauschalgorithmus bei der Erzeugung des Premaster-Secrets die Ergebnisse des Schl\u00fcsselaustauschs gehasht und hierbei zun\u00e4chst die f\u00fchrenden Nullen entfernt werden. Ein Angreifer in einer Man-in-the-Middle Position kann dieses messen. Au\u00dferdem muss der Server so konfiguriert sein, dass er statische TLS-DH-Verschl\u00fcsselungssuiten verwendet oder der Server muss kurzlebige Verschl\u00fcsselungssuiten (TLS-DHE) verwenden und die Schl\u00fcssel f\u00fcr mehrere Verbindungen wiederverwenden. Durch Manipulation und mehrfaches Versenden der abgefangenen Daten kann der Angreifer dann m\u00f6glicherweise den Schl\u00fcssel erlangen." } ], "product_status": { "known_affected": [ "T017244", "2951", "T002207", "T000126", "7654", "T030689", "T000872", "T001663", "T033681", "T012167", "T032354" ] }, "release_date": "2020-09-09T22:00:00Z", "title": "CVE-2020-1968" }, { "cve": "CVE-2020-5929", "notes": [ { "category": "description", "text": "In der Spezifikation von TLS 1.2 oder fr\u00fcher existiert eine Schwachstelle. Sie beruht darauf, dass bei Verwendung des Diffie-Hellman (DH) Schl\u00fcsselaustauschalgorithmus bei der Erzeugung des Premaster-Secrets die Ergebnisse des Schl\u00fcsselaustauschs gehasht und hierbei zun\u00e4chst die f\u00fchrenden Nullen entfernt werden. Ein Angreifer in einer Man-in-the-Middle Position kann dieses messen. Au\u00dferdem muss der Server so konfiguriert sein, dass er statische TLS-DH-Verschl\u00fcsselungssuiten verwendet oder der Server muss kurzlebige Verschl\u00fcsselungssuiten (TLS-DHE) verwenden und die Schl\u00fcssel f\u00fcr mehrere Verbindungen wiederverwenden. Durch Manipulation und mehrfaches Versenden der abgefangenen Daten kann der Angreifer dann m\u00f6glicherweise den Schl\u00fcssel erlangen." } ], "product_status": { "known_affected": [ "T017244", "2951", "T002207", "T000126", "7654", "T030689", "T000872", "T001663", "T033681", "T012167", "T032354" ] }, "release_date": "2020-09-09T22:00:00Z", "title": "CVE-2020-5929" } ] }
ghsa-mh8f-5gw2-5wgh
Vulnerability from github
The Raccoon attack exploits a flaw in the TLS specification which can lead to an attacker being able to compute the pre-master secret in connections which have used a Diffie-Hellman (DH) based ciphersuite. In such a case this would result in the attacker being able to eavesdrop on all encrypted communications sent over that TLS connection. The attack can only be exploited if an implementation re-uses a DH secret across multiple TLS connections. Note that this issue only impacts DH ciphersuites and not ECDH ciphersuites. This issue affects OpenSSL 1.0.2 which is out of support and no longer receiving public updates. OpenSSL 1.1.1 is not vulnerable to this issue. Fixed in OpenSSL 1.0.2w (Affected 1.0.2-1.0.2v).
{ "affected": [], "aliases": [ "CVE-2020-1968" ], "database_specific": { "cwe_ids": [ "CWE-203", "CWE-326" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2020-09-09T14:15:00Z", "severity": "MODERATE" }, "details": "The Raccoon attack exploits a flaw in the TLS specification which can lead to an attacker being able to compute the pre-master secret in connections which have used a Diffie-Hellman (DH) based ciphersuite. In such a case this would result in the attacker being able to eavesdrop on all encrypted communications sent over that TLS connection. The attack can only be exploited if an implementation re-uses a DH secret across multiple TLS connections. Note that this issue only impacts DH ciphersuites and not ECDH ciphersuites. This issue affects OpenSSL 1.0.2 which is out of support and no longer receiving public updates. OpenSSL 1.1.1 is not vulnerable to this issue. Fixed in OpenSSL 1.0.2w (Affected 1.0.2-1.0.2v).", "id": "GHSA-mh8f-5gw2-5wgh", "modified": "2022-05-24T17:27:38Z", "published": "2022-05-24T17:27:38Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2020-1968" }, { "type": "WEB", "url": "https://lists.debian.org/debian-lts-announce/2020/09/msg00016.html" }, { "type": "WEB", "url": "https://security.gentoo.org/glsa/202210-02" }, { "type": "WEB", "url": "https://security.netapp.com/advisory/ntap-20200911-0004" }, { "type": "WEB", "url": "https://usn.ubuntu.com/4504-1" }, { "type": "WEB", "url": "https://www.openssl.org/news/secadv/20200909.txt" }, { "type": "WEB", "url": "https://www.oracle.com//security-alerts/cpujul2021.html" }, { "type": "WEB", "url": "https://www.oracle.com/security-alerts/cpuApr2021.html" }, { "type": "WEB", "url": "https://www.oracle.com/security-alerts/cpuapr2022.html" }, { "type": "WEB", "url": "https://www.oracle.com/security-alerts/cpujan2021.html" }, { "type": "WEB", "url": "https://www.oracle.com/security-alerts/cpuoct2021.html" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N", "type": "CVSS_V3" } ] }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.