GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2020-22659 (GCVE-0-2020-22659)

Vulnerability from cvelistv5 – Published: 2023-01-20 00:00 – Updated: 2025-04-03 17:57
VLAI
Summary
In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300) before 3.6.2.0.795, Virtual SmartZone (vSZ) before 3.6.2.0.795, ZoneDirector 1100 9.10.2.0.130, ZoneDirector 1200 10.2.1.0.218, ZoneDirector 3000 10.2.1.0.218, ZoneDirector 5000 10.0.1.0.151, a vulnerability allows attackers to exploit the official image signature to force injection unauthorized image signature.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-04-03 17:56 UTC
CWE
  • n/a
  • CWE-347 - Improper Verification of Cryptographic Signature
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T14:51:11.182Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.ruckuswireless.com/security_bulletins/302"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "NONE",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2020-22659",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-03T17:56:23.793345Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-347",
                "description": "CWE-347 Improper Verification of Cryptographic Signature",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-03T17:57:18.623Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300) before 3.6.2.0.795, Virtual SmartZone (vSZ) before 3.6.2.0.795, ZoneDirector 1100 9.10.2.0.130, ZoneDirector 1200 10.2.1.0.218, ZoneDirector 3000 10.2.1.0.218, ZoneDirector 5000 10.0.1.0.151, a vulnerability allows attackers to exploit the official image signature to force injection unauthorized image signature."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-06T20:14:18.648Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://support.ruckuswireless.com/security_bulletins/302"
        },
        {
          "url": "https://hdhrmi.blogspot.com/2020/03/multiple-vulnerabilities-in-ruckus.html?m=1"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-22659",
    "datePublished": "2023-01-20T00:00:00.000Z",
    "dateReserved": "2020-08-13T00:00:00.000Z",
    "dateUpdated": "2025-04-03T17:57:18.623Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2020-22659",
      "date": "2026-09-15",
      "epss": "0.00313",
      "percentile": "0.24103"
    },
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ruckuswireless:r310_firmware:10.5.1.0.199:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5ED8801F-2B0B-480D-876D-9F662B995851\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ruckuswireless:r310:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"40D3129E-4C02-484F-96B6-59D76F787D21\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ruckuswireless:r500_firmware:10.5.1.0.199:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E54CB15F-CA79-403B-A1B1-B7832B65EEC3\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ruckuswireless:r500:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"9BBDBE9C-BE4B-4ED6-AF62-8FE484C519E2\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ruckuswireless:r600_firmware:10.5.1.0.199:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"27E05347-1CFD-46FC-999A-90E6C40CEE26\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ruckuswireless:r600:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5421B1D7-E630-4BDA-BA34-7DD8D0738DF4\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ruckuswireless:t300_firmware:10.5.1.0.199:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5D91278C-B07E-44FF-ABBA-10E8B5830FFA\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ruckuswireless:t300:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0511674E-59A6-427C-A265-B277D84DE301\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ruckuswireless:t301n_firmware:10.5.1.0.199:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E0412E29-6DB5-4C01-B8C3-702EB7EBE8DE\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ruckuswireless:t301n:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"EBB7A43E-F5F1-465A-841F-05214EDA6833\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ruckuswireless:t301s_firmware:10.5.1.0.199:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"6DAA3771-2795-403D-8506-C155403C8B7C\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ruckuswireless:t301s:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"68C4D9AC-5B1C-4066-8216-3F7127C3CC64\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ruckuswireless:scg200_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.6.2.0.795\", \"matchCriteriaId\": \"775F1067-344F-49AD-9901-97D2F1AC5F0F\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ruckuswireless:scg200:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E6FB3968-8D8A-4D04-B3D1-18A28CA8C249\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ruckuswireless:sz-100_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.6.2.0.795\", \"matchCriteriaId\": \"46BCF71C-8A66-45C8-B1ED-8957B670CBF5\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ruckuswireless:sz-100:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3B9F3E41-79CA-45B7-B799-B0A64E60BA16\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ruckuswireless:sz-300_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.6.2.0.795\", \"matchCriteriaId\": \"7CEA2295-79BE-4728-8BF2-DEAB2BCAA0E5\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ruckuswireless:sz-300:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"4087D2FB-0853-40AE-A03F-803B5972A404\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ruckuswireless:vsz_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"3.6.2.0.795\", \"matchCriteriaId\": \"B3E5690D-7955-4E12-AE51-C3CDAD596096\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ruckuswireless:vsz:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"A1E9A46B-D8E4-489A-8648-28EDDF000E28\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ruckuswireless:zonedirector_1100_firmware:9.10.2.0.130:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"76872953-AA21-41F1-832E-5CD04CA0FF9A\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ruckuswireless:zonedirector_1100:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"CF376AF6-E73A-425B-8E31-36330D8FEB73\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ruckuswireless:zonedirector_1200_firmware:10.2.1.0.218:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"83AD20A3-C56E-4436-A9CC-29884EF9EB67\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ruckuswireless:zonedirector_1200:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0FE0C2B2-D14B-4798-95C4-F911B3B1D88E\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ruckuswireless:zonedirector_3000_firmware:10.2.1.0.218:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"86A26EBE-4077-4DE7-BC6C-D38F5A3D3E7B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ruckuswireless:zonedirector_3000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5A1F42A8-8785-48A5-B0B0-68504EFD38B9\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:ruckuswireless:zonedirector_5000_firmware:10.0.1.0.151:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"04D53E59-6431-4ED3-BA0B-E54B2FBCDE0D\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:ruckuswireless:zonedirector_5000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1DA49DE5-DA7F-4531-9ACF-353561DA90E4\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300) before 3.6.2.0.795, Virtual SmartZone (vSZ) before 3.6.2.0.795, ZoneDirector 1100 9.10.2.0.130, ZoneDirector 1200 10.2.1.0.218, ZoneDirector 3000 10.2.1.0.218, ZoneDirector 5000 10.0.1.0.151, a vulnerability allows attackers to exploit the official image signature to force injection unauthorized image signature.\"}, {\"lang\": \"es\", \"value\": \"En Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0 .199, SmartCell Gateway 200 (SCG200) anterior a 3.6.2.0.795, SmartZone 100 (SZ-100) anterior a 3.6.2.0.795, SmartZone 300 (SZ300) anterior a 3.6.2.0.795, Virtual SmartZone (vSZ) anterior a 3.6.2.0.795, ZoneDirector 1100 9.10.2.0.130, ZoneDirector 1200 10.2.1.0.218, ZoneDirector 3000 10.2.1.0.218, ZoneDirector 5000 10.0.1.0.151, una vulnerabilidad permite a los atacantes explotar la firma de la imagen oficial para forzar la inyecci\\u00f3n de una firma de imagen no autorizada.\"}]",
      "id": "CVE-2020-22659",
      "lastModified": "2024-11-21T05:13:21.283",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 3.6}]}",
      "published": "2023-01-20T19:15:12.897",
      "references": "[{\"url\": \"https://hdhrmi.blogspot.com/2020/03/multiple-vulnerabilities-in-ruckus.html?m=1\", \"source\": \"cve@mitre.org\"}, {\"url\": \"https://support.ruckuswireless.com/security_bulletins/302\", \"source\": \"cve@mitre.org\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://support.ruckuswireless.com/security_bulletins/302\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
      "sourceIdentifier": "cve@mitre.org",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-noinfo\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2020-22659\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2023-01-20T19:15:12.897\",\"lastModified\":\"2025-04-03T18:15:40.023\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300) before 3.6.2.0.795, Virtual SmartZone (vSZ) before 3.6.2.0.795, ZoneDirector 1100 9.10.2.0.130, ZoneDirector 1200 10.2.1.0.218, ZoneDirector 3000 10.2.1.0.218, ZoneDirector 5000 10.0.1.0.151, a vulnerability allows attackers to exploit the official image signature to force injection unauthorized image signature.\"},{\"lang\":\"es\",\"value\":\"En Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0 .199, SmartCell Gateway 200 (SCG200) anterior a 3.6.2.0.795, SmartZone 100 (SZ-100) anterior a 3.6.2.0.795, SmartZone 300 (SZ300) anterior a 3.6.2.0.795, Virtual SmartZone (vSZ) anterior a 3.6.2.0.795, ZoneDirector 1100 9.10.2.0.130, ZoneDirector 1200 10.2.1.0.218, ZoneDirector 3000 10.2.1.0.218, ZoneDirector 5000 10.0.1.0.151, una vulnerabilidad permite a los atacantes explotar la firma de la imagen oficial para forzar la inyecci\u00f3n de una firma de imagen no autorizada.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]},{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-347\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ruckuswireless:r310_firmware:10.5.1.0.199:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5ED8801F-2B0B-480D-876D-9F662B995851\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:r310:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"40D3129E-4C02-484F-96B6-59D76F787D21\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ruckuswireless:r500_firmware:10.5.1.0.199:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E54CB15F-CA79-403B-A1B1-B7832B65EEC3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:r500:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9BBDBE9C-BE4B-4ED6-AF62-8FE484C519E2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ruckuswireless:r600_firmware:10.5.1.0.199:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"27E05347-1CFD-46FC-999A-90E6C40CEE26\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:r600:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5421B1D7-E630-4BDA-BA34-7DD8D0738DF4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ruckuswireless:t300_firmware:10.5.1.0.199:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5D91278C-B07E-44FF-ABBA-10E8B5830FFA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:t300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0511674E-59A6-427C-A265-B277D84DE301\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ruckuswireless:t301n_firmware:10.5.1.0.199:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E0412E29-6DB5-4C01-B8C3-702EB7EBE8DE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:t301n:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EBB7A43E-F5F1-465A-841F-05214EDA6833\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ruckuswireless:t301s_firmware:10.5.1.0.199:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6DAA3771-2795-403D-8506-C155403C8B7C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:t301s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"68C4D9AC-5B1C-4066-8216-3F7127C3CC64\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ruckuswireless:scg200_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.6.2.0.795\",\"matchCriteriaId\":\"775F1067-344F-49AD-9901-97D2F1AC5F0F\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:scg200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E6FB3968-8D8A-4D04-B3D1-18A28CA8C249\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ruckuswireless:sz-100_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.6.2.0.795\",\"matchCriteriaId\":\"46BCF71C-8A66-45C8-B1ED-8957B670CBF5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:sz-100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3B9F3E41-79CA-45B7-B799-B0A64E60BA16\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ruckuswireless:sz-300_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.6.2.0.795\",\"matchCriteriaId\":\"7CEA2295-79BE-4728-8BF2-DEAB2BCAA0E5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:sz-300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4087D2FB-0853-40AE-A03F-803B5972A404\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ruckuswireless:vsz_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.6.2.0.795\",\"matchCriteriaId\":\"B3E5690D-7955-4E12-AE51-C3CDAD596096\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:vsz:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A1E9A46B-D8E4-489A-8648-28EDDF000E28\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ruckuswireless:zonedirector_1100_firmware:9.10.2.0.130:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"76872953-AA21-41F1-832E-5CD04CA0FF9A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:zonedirector_1100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CF376AF6-E73A-425B-8E31-36330D8FEB73\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ruckuswireless:zonedirector_1200_firmware:10.2.1.0.218:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"83AD20A3-C56E-4436-A9CC-29884EF9EB67\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:zonedirector_1200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0FE0C2B2-D14B-4798-95C4-F911B3B1D88E\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ruckuswireless:zonedirector_3000_firmware:10.2.1.0.218:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"86A26EBE-4077-4DE7-BC6C-D38F5A3D3E7B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:zonedirector_3000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5A1F42A8-8785-48A5-B0B0-68504EFD38B9\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:ruckuswireless:zonedirector_5000_firmware:10.0.1.0.151:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"04D53E59-6431-4ED3-BA0B-E54B2FBCDE0D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:ruckuswireless:zonedirector_5000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1DA49DE5-DA7F-4531-9ACF-353561DA90E4\"}]}]}],\"references\":[{\"url\":\"https://hdhrmi.blogspot.com/2020/03/multiple-vulnerabilities-in-ruckus.html?m=1\",\"source\":\"cve@mitre.org\"},{\"url\":\"https://support.ruckuswireless.com/security_bulletins/302\",\"source\":\"cve@mitre.org\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://support.ruckuswireless.com/security_bulletins/302\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://support.ruckuswireless.com/security_bulletins/302\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-04T14:51:11.182Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"NONE\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2020-22659\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-03T17:56:23.793345Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-347\", \"description\": \"CWE-347 Improper Verification of Cryptographic Signature\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-04-03T17:57:12.844Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"references\": [{\"url\": \"https://support.ruckuswireless.com/security_bulletins/302\"}, {\"url\": \"https://hdhrmi.blogspot.com/2020/03/multiple-vulnerabilities-in-ruckus.html?m=1\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300) before 3.6.2.0.795, Virtual SmartZone (vSZ) before 3.6.2.0.795, ZoneDirector 1100 9.10.2.0.130, ZoneDirector 1200 10.2.1.0.218, ZoneDirector 3000 10.2.1.0.218, ZoneDirector 5000 10.0.1.0.151, a vulnerability allows attackers to exploit the official image signature to force injection unauthorized image signature.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"n/a\"}]}], \"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2024-08-06T20:14:18.648Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2020-22659\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-04-03T17:57:18.623Z\", \"dateReserved\": \"2020-08-13T00:00:00.000Z\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"datePublished\": \"2023-01-20T00:00:00.000Z\", \"assignerShortName\": \"mitre\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…