CVE-2020-26921 (GCVE-0-2020-26921)
Vulnerability from cvelistv5 – Published: 2020-10-09 06:28 – Updated: 2024-08-04 16:03
VLAI?
Summary
Certain NETGEAR devices are affected by authentication bypass. This affects GS110EMX before 1.0.1.7, GS810EMX before 1.7.1.3, XS512EM before 1.0.1.3, and XS724EM before 1.0.1.3.
Severity ?
8.3 (High)
CWE
- n/a
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:03:22.899Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://kb.netgear.com/000062332/Security-Advisory-for-Authentication-Bypass-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0305"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by authentication bypass. This affects GS110EMX before 1.0.1.7, GS810EMX before 1.7.1.3, XS512EM before 1.0.1.3, and XS724EM before 1.0.1.3."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:L/I:H/PR:N/S:U/UI:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-10-09T06:28:15",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://kb.netgear.com/000062332/Security-Advisory-for-Authentication-Bypass-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0305"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-26921",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Certain NETGEAR devices are affected by authentication bypass. This affects GS110EMX before 1.0.1.7, GS810EMX before 1.7.1.3, XS512EM before 1.0.1.3, and XS724EM before 1.0.1.3."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT",
"availabilityImpact": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AC:L/AV:A/A:H/C:L/I:H/PR:N/S:U/UI:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://kb.netgear.com/000062332/Security-Advisory-for-Authentication-Bypass-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0305",
"refsource": "MISC",
"url": "https://kb.netgear.com/000062332/Security-Advisory-for-Authentication-Bypass-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0305"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-26921",
"datePublished": "2020-10-09T06:28:15",
"dateReserved": "2020-10-09T00:00:00",
"dateUpdated": "2024-08-04T16:03:22.899Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:gs110emx_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.1.7\", \"matchCriteriaId\": \"682F53A0-6A97-44DE-B41B-183FE26696B4\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:gs110emx:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"0E1EEC50-F8C6-4B34-AB0A-EC5466FF7A74\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:gs810emx_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.7.1.3\", \"matchCriteriaId\": \"CA0BCF94-A218-405F-A354-087940AE6DC3\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:gs810emx:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"91F71973-C209-4401-B887-9399F9552D7D\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:xs512em_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.1.3\", \"matchCriteriaId\": \"3BFF0337-E1F3-434B-99DF-333768F6E29B\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:xs512em:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"48FCC8F7-1043-4069-924D-0124FE5D10B0\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:netgear:xs724em_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"1.0.1.3\", \"matchCriteriaId\": \"61D02F44-059E-46C9-9B2F-E44D35E63550\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:netgear:xs724em:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"30918F59-D8C5-4A49-A10D-A5703261CCE1\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Certain NETGEAR devices are affected by authentication bypass. This affects GS110EMX before 1.0.1.7, GS810EMX before 1.7.1.3, XS512EM before 1.0.1.3, and XS724EM before 1.0.1.3.\"}, {\"lang\": \"es\", \"value\": \"Determinados dispositivos NETGEAR, est\\u00e1n afectados por una omisi\\u00f3n de autenticaci\\u00f3n.\u0026#xa0;Esto afecta a GS110EMX versiones anteriores a 1.0.1.7, GS810EMX versiones anteriores a 1.7.1.3, XS512EM versiones anteriores a 1.0.1.3 y XS724EM versiones anteriores a 1.0.1.3\"}]",
"id": "CVE-2020-26921",
"lastModified": "2024-11-21T05:20:30.073",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cve@mitre.org\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H\", \"baseScore\": 8.3, \"baseSeverity\": \"HIGH\", \"attackVector\": \"ADJACENT_NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.5}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"ADJACENT_NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:A/AC:L/Au:N/C:P/I:P/A:P\", \"baseScore\": 5.8, \"accessVector\": \"ADJACENT_NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"PARTIAL\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"PARTIAL\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 6.5, \"impactScore\": 6.4, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2020-10-09T07:15:17.760",
"references": "[{\"url\": \"https://kb.netgear.com/000062332/Security-Advisory-for-Authentication-Bypass-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0305\", \"source\": \"cve@mitre.org\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://kb.netgear.com/000062332/Security-Advisory-for-Authentication-Bypass-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0305\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-287\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-26921\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2020-10-09T07:15:17.760\",\"lastModified\":\"2024-11-21T05:20:30.073\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Certain NETGEAR devices are affected by authentication bypass. This affects GS110EMX before 1.0.1.7, GS810EMX before 1.7.1.3, XS512EM before 1.0.1.3, and XS724EM before 1.0.1.3.\"},{\"lang\":\"es\",\"value\":\"Determinados dispositivos NETGEAR, est\u00e1n afectados por una omisi\u00f3n de autenticaci\u00f3n.\u0026#xa0;Esto afecta a GS110EMX versiones anteriores a 1.0.1.7, GS810EMX versiones anteriores a 1.7.1.3, XS512EM versiones anteriores a 1.0.1.3 y XS724EM versiones anteriores a 1.0.1.3\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cve@mitre.org\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H\",\"baseScore\":8.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.5},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:A/AC:L/Au:N/C:P/I:P/A:P\",\"baseScore\":5.8,\"accessVector\":\"ADJACENT_NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":6.5,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:gs110emx_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.1.7\",\"matchCriteriaId\":\"682F53A0-6A97-44DE-B41B-183FE26696B4\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:gs110emx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0E1EEC50-F8C6-4B34-AB0A-EC5466FF7A74\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:gs810emx_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.7.1.3\",\"matchCriteriaId\":\"CA0BCF94-A218-405F-A354-087940AE6DC3\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:gs810emx:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"91F71973-C209-4401-B887-9399F9552D7D\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:xs512em_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.1.3\",\"matchCriteriaId\":\"3BFF0337-E1F3-434B-99DF-333768F6E29B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:xs512em:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"48FCC8F7-1043-4069-924D-0124FE5D10B0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:netgear:xs724em_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.0.1.3\",\"matchCriteriaId\":\"61D02F44-059E-46C9-9B2F-E44D35E63550\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:netgear:xs724em:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"30918F59-D8C5-4A49-A10D-A5703261CCE1\"}]}]}],\"references\":[{\"url\":\"https://kb.netgear.com/000062332/Security-Advisory-for-Authentication-Bypass-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0305\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://kb.netgear.com/000062332/Security-Advisory-for-Authentication-Bypass-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0305\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…