cve-2020-28384
Vulnerability from cvelistv5
Published
2021-01-12 20:18
Modified
2024-08-04 16:33
Severity ?
Summary
A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP12), Solid Edge SE2021 (All Versions < SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process.
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:33:59.070Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-055/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-076/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Solid Edge SE2020",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c SE2020MP12"
            }
          ]
        },
        {
          "product": "Solid Edge SE2021",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All Versions \u003c SE2021MP2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-121",
              "description": "CWE-121: Stack-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-02-09T15:38:20",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-055/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-076/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2020-28384",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Solid Edge SE2020",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All Versions \u003c SE2020MP12"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Solid Edge SE2021",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All Versions \u003c SE2021MP2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-121: Stack-based Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-055/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-055/"
            },
            {
              "name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04",
              "refsource": "MISC",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-076/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-076/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-28384",
    "datePublished": "2021-01-12T20:18:35",
    "dateReserved": "2020-11-10T00:00:00",
    "dateUpdated": "2024-08-04T16:33:59.070Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2020-28384\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2021-01-12T21:15:17.917\",\"lastModified\":\"2021-12-10T21:45:27.490\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP12), Solid Edge SE2021 (All Versions \u003c SE2021MP2). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could lead to a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Solid Edge SE2020 (Todas las versiones anteriores a SE2020MP12), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP2). Las aplicaciones afectadas carecen de una comprobaci\u00f3n apropiada de los datos proporcionados por el usuario al analizar archivos PAR. Esto podr\u00eda conllevar a un desbordamiento del b\u00fafer en la regi\u00f3n stack de la memoria. Un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":6.8},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-121\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"se2020\",\"matchCriteriaId\":\"7AF39DFE-A31B-4324-BB62-0B446ACA04B7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"07440B76-B975-4946-8A97-38C564D240E4\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack1:*:*:*:*:*:*\",\"matchCriteriaId\":\"5F0A748E-BB6F-4604-8024-F50DC0C20EAF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack10:*:*:*:*:*:*\",\"matchCriteriaId\":\"F4F37267-6B37-46A4-B9F9-4264BEC922D1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack11:*:*:*:*:*:*\",\"matchCriteriaId\":\"CB1DC54B-E715-4425-B6B6-900F2CFBCE03\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack2:*:*:*:*:*:*\",\"matchCriteriaId\":\"2F495722-39BD-4BA1-A643-C7D0BA81CC21\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack3:*:*:*:*:*:*\",\"matchCriteriaId\":\"7B776512-BF3D-4F70-BD58-AFF8E1B03EE2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack4:*:*:*:*:*:*\",\"matchCriteriaId\":\"99E05299-50FD-4292-9978-8E05C1483FE2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack5:*:*:*:*:*:*\",\"matchCriteriaId\":\"2447D05B-2634-4895-B7B0-6F7DBB9D2EC2\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack6:*:*:*:*:*:*\",\"matchCriteriaId\":\"CBBD39F3-790F-4017-A57E-6EFC314F0557\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack7:*:*:*:*:*:*\",\"matchCriteriaId\":\"B4387BFA-8A98-433E-9EF7-B29226C195A7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack8:*:*:*:*:*:*\",\"matchCriteriaId\":\"9E380F66-C11C-472B-9B71-7CB4AF4FABDC\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack9:*:*:*:*:*:*\",\"matchCriteriaId\":\"0CF4ACE1-B069-4007-8142-7F90015BBE9D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*\",\"matchCriteriaId\":\"39D237BD-EE55-4B40-ABC3-194C4BF7C6CD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*\",\"matchCriteriaId\":\"49F5649A-349C-42C6-AFFF-CEE1ABC14E67\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-979834.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://us-cert.cisa.gov/ics/advisories/icsa-21-012-04\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"US Government Resource\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-055/\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-076/\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.