CVE-2020-7240 (GCVE-0-2020-7240)
Vulnerability from cvelistv5 – Published: 2020-01-20 19:27 – Updated: 2024-08-28 13:28 Disputed
VLAI?
Summary
Meinberg Lantime M300 and M1000 devices allow attackers (with privileges to configure a device) to execute arbitrary OS commands by editing the /config/netconf.cmd script (aka Extended Network Configuration). Note: According to the description, the vulnerability requires a fully authenticated super-user account using a webUI function that allows super users to edit a script supposed to execute OS commands. The given weakness enumeration (CWE-78) is not applicable in this case as it refers to abusing functions/input fields not supposed to be accepting OS commands by using 'Special Elements.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:h:meinberg:ims-lantime_m1000:-:*:*:*:*:*:*:*"
],
"defaultStatus": "affected",
"product": "ims-lantime_m1000",
"vendor": "meinberg",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:h:meinberg:lantime_m300:-:*:*:*:*:*:*:*"
],
"defaultStatus": "affected",
"product": "lantime_m300",
"vendor": "meinberg",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2020-7240",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-28T13:28:09.070070Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-28T13:28:59.219Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:25:48.448Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://sku11army.blogspot.com/2020/01/heinberg-lantime-m1000-rce.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://sku11army.blogspot.com/2020/01/meinberg-lantime-m1000-rce.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://wolke.meinberg.de/index.php/s/dKP3PKgFXS6sPRE#pdfviewer"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Meinberg Lantime M300 and M1000 devices allow attackers (with privileges to configure a device) to execute arbitrary OS commands by editing the /config/netconf.cmd script (aka Extended Network Configuration). Note: According to the description, the vulnerability requires a fully authenticated super-user account using a webUI function that allows super users to edit a script supposed to execute OS commands. The given weakness enumeration (CWE-78) is not applicable in this case as it refers to abusing functions/input fields not supposed to be accepting OS commands by using \u0027Special Elements."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-02-11T12:02:33",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://sku11army.blogspot.com/2020/01/heinberg-lantime-m1000-rce.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://sku11army.blogspot.com/2020/01/meinberg-lantime-m1000-rce.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://wolke.meinberg.de/index.php/s/dKP3PKgFXS6sPRE#pdfviewer"
}
],
"tags": [
"disputed"
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-7240",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "** DISPUTED ** Meinberg Lantime M300 and M1000 devices allow attackers (with privileges to configure a device) to execute arbitrary OS commands by editing the /config/netconf.cmd script (aka Extended Network Configuration). Note: According to the description, the vulnerability requires a fully authenticated super-user account using a webUI function that allows super users to edit a script supposed to execute OS commands. The given weakness enumeration (CWE-78) is not applicable in this case as it refers to abusing functions/input fields not supposed to be accepting OS commands by using \u0027Special Elements.\u0027"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://sku11army.blogspot.com/2020/01/heinberg-lantime-m1000-rce.html",
"refsource": "MISC",
"url": "https://sku11army.blogspot.com/2020/01/heinberg-lantime-m1000-rce.html"
},
{
"name": "https://sku11army.blogspot.com/2020/01/meinberg-lantime-m1000-rce.html",
"refsource": "MISC",
"url": "https://sku11army.blogspot.com/2020/01/meinberg-lantime-m1000-rce.html"
},
{
"name": "https://wolke.meinberg.de/index.php/s/dKP3PKgFXS6sPRE#pdfviewer",
"refsource": "MISC",
"url": "https://wolke.meinberg.de/index.php/s/dKP3PKgFXS6sPRE#pdfviewer"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-7240",
"datePublished": "2020-01-20T19:27:51",
"dateReserved": "2020-01-20T00:00:00",
"dateUpdated": "2024-08-28T13:28:59.219Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:meinbergglobal:lantime_m300_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"2E3FA110-8EF7-4E9B-A7B7-40CB534E9AE6\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:meinbergglobal:lantime_m300:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"D5FCA50A-2C6A-41ED-8E9D-38BA52C8428B\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:meinbergglobal:lantime_m1000_firmware:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"749D2112-626A-4A59-B8F4-F1C75CB8ED94\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:meinbergglobal:lantime_m1000:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E35F4190-89B4-4F14-89C9-C7A4E61FB300\"}]}]}]",
"cveTags": "[{\"sourceIdentifier\": \"cve@mitre.org\", \"tags\": [\"disputed\"]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Meinberg Lantime M300 and M1000 devices allow attackers (with privileges to configure a device) to execute arbitrary OS commands by editing the /config/netconf.cmd script (aka Extended Network Configuration). Note: According to the description, the vulnerability requires a fully authenticated super-user account using a webUI function that allows super users to edit a script supposed to execute OS commands. The given weakness enumeration (CWE-78) is not applicable in this case as it refers to abusing functions/input fields not supposed to be accepting OS commands by using \u0027Special Elements.\"}, {\"lang\": \"es\", \"value\": \"** EN DSIPUTA ** Los dispositivos Meinberg Lantime M300 y M1000 permiten a los atacantes (con privilegios para configurar un dispositivo) ejecutar comandos arbitrarios del sistema operativo editando el script /config/netconf.cmd (tambi\\u00e9n conocido como Configuraci\\u00f3n de red extendida). Nota: Seg\\u00fan la descripci\\u00f3n, la vulnerabilidad requiere una cuenta de superusuario totalmente autenticada que use una funci\\u00f3n webUI que permita a los superusuarios editar un script que supuestamente ejecute comandos del sistema operativo. La enumeraci\\u00f3n de debilidad dada (CWE-78) no es aplicable en este caso, ya que se refiere al abuso de funciones / campos de entrada que no deben aceptar comandos del sistema operativo mediante el uso de \u0027Elementos especiales\u0027.\"}]",
"id": "CVE-2020-7240",
"lastModified": "2024-11-21T05:36:54.123",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:S/C:C/I:C/A:C\", \"baseScore\": 9.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 8.0, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2020-01-20T20:15:11.317",
"references": "[{\"url\": \"https://sku11army.blogspot.com/2020/01/heinberg-lantime-m1000-rce.html\", \"source\": \"cve@mitre.org\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://sku11army.blogspot.com/2020/01/meinberg-lantime-m1000-rce.html\", \"source\": \"cve@mitre.org\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://wolke.meinberg.de/index.php/s/dKP3PKgFXS6sPRE#pdfviewer\", \"source\": \"cve@mitre.org\"}, {\"url\": \"https://sku11army.blogspot.com/2020/01/heinberg-lantime-m1000-rce.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://sku11army.blogspot.com/2020/01/meinberg-lantime-m1000-rce.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Exploit\", \"Third Party Advisory\"]}, {\"url\": \"https://wolke.meinberg.de/index.php/s/dKP3PKgFXS6sPRE#pdfviewer\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-78\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-7240\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2020-01-20T20:15:11.317\",\"lastModified\":\"2024-11-21T05:36:54.123\",\"vulnStatus\":\"Modified\",\"cveTags\":[{\"sourceIdentifier\":\"cve@mitre.org\",\"tags\":[\"disputed\"]}],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Meinberg Lantime M300 and M1000 devices allow attackers (with privileges to configure a device) to execute arbitrary OS commands by editing the /config/netconf.cmd script (aka Extended Network Configuration). Note: According to the description, the vulnerability requires a fully authenticated super-user account using a webUI function that allows super users to edit a script supposed to execute OS commands. The given weakness enumeration (CWE-78) is not applicable in this case as it refers to abusing functions/input fields not supposed to be accepting OS commands by using \u0027Special Elements.\"},{\"lang\":\"es\",\"value\":\"** EN DSIPUTA ** Los dispositivos Meinberg Lantime M300 y M1000 permiten a los atacantes (con privilegios para configurar un dispositivo) ejecutar comandos arbitrarios del sistema operativo editando el script /config/netconf.cmd (tambi\u00e9n conocido como Configuraci\u00f3n de red extendida). Nota: Seg\u00fan la descripci\u00f3n, la vulnerabilidad requiere una cuenta de superusuario totalmente autenticada que use una funci\u00f3n webUI que permita a los superusuarios editar un script que supuestamente ejecute comandos del sistema operativo. La enumeraci\u00f3n de debilidad dada (CWE-78) no es aplicable en este caso, ya que se refiere al abuso de funciones / campos de entrada que no deben aceptar comandos del sistema operativo mediante el uso de \u0027Elementos especiales\u0027.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:C/I:C/A:C\",\"baseScore\":9.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:meinbergglobal:lantime_m300_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2E3FA110-8EF7-4E9B-A7B7-40CB534E9AE6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:meinbergglobal:lantime_m300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D5FCA50A-2C6A-41ED-8E9D-38BA52C8428B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:meinbergglobal:lantime_m1000_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"749D2112-626A-4A59-B8F4-F1C75CB8ED94\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:meinbergglobal:lantime_m1000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E35F4190-89B4-4F14-89C9-C7A4E61FB300\"}]}]}],\"references\":[{\"url\":\"https://sku11army.blogspot.com/2020/01/heinberg-lantime-m1000-rce.html\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://sku11army.blogspot.com/2020/01/meinberg-lantime-m1000-rce.html\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://wolke.meinberg.de/index.php/s/dKP3PKgFXS6sPRE#pdfviewer\",\"source\":\"cve@mitre.org\"},{\"url\":\"https://sku11army.blogspot.com/2020/01/heinberg-lantime-m1000-rce.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://sku11army.blogspot.com/2020/01/meinberg-lantime-m1000-rce.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://wolke.meinberg.de/index.php/s/dKP3PKgFXS6sPRE#pdfviewer\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://sku11army.blogspot.com/2020/01/heinberg-lantime-m1000-rce.html\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}, {\"url\": \"https://sku11army.blogspot.com/2020/01/meinberg-lantime-m1000-rce.html\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}, {\"url\": \"https://wolke.meinberg.de/index.php/s/dKP3PKgFXS6sPRE#pdfviewer\", \"tags\": [\"x_refsource_MISC\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-04T09:25:48.448Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2020-7240\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-08-28T13:28:09.070070Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:h:meinberg:ims-lantime_m1000:-:*:*:*:*:*:*:*\"], \"vendor\": \"meinberg\", \"product\": \"ims-lantime_m1000\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"affected\"}, {\"cpes\": [\"cpe:2.3:h:meinberg:lantime_m300:-:*:*:*:*:*:*:*\"], \"vendor\": \"meinberg\", \"product\": \"lantime_m300\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"*\", \"versionType\": \"custom\"}], \"defaultStatus\": \"affected\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-06-11T18:06:51.872Z\"}}], \"cna\": {\"tags\": [\"disputed\"], \"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"references\": [{\"url\": \"https://sku11army.blogspot.com/2020/01/heinberg-lantime-m1000-rce.html\", \"tags\": [\"x_refsource_MISC\"]}, {\"url\": \"https://sku11army.blogspot.com/2020/01/meinberg-lantime-m1000-rce.html\", \"tags\": [\"x_refsource_MISC\"]}, {\"url\": \"https://wolke.meinberg.de/index.php/s/dKP3PKgFXS6sPRE#pdfviewer\", \"tags\": [\"x_refsource_MISC\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"Meinberg Lantime M300 and M1000 devices allow attackers (with privileges to configure a device) to execute arbitrary OS commands by editing the /config/netconf.cmd script (aka Extended Network Configuration). Note: According to the description, the vulnerability requires a fully authenticated super-user account using a webUI function that allows super users to edit a script supposed to execute OS commands. The given weakness enumeration (CWE-78) is not applicable in this case as it refers to abusing functions/input fields not supposed to be accepting OS commands by using \u0027Special Elements.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"n/a\"}]}], \"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2020-02-11T12:02:33\"}, \"x_legacyV4Record\": {\"affects\": {\"vendor\": {\"vendor_data\": [{\"product\": {\"product_data\": [{\"version\": {\"version_data\": [{\"version_value\": \"n/a\"}]}, \"product_name\": \"n/a\"}]}, \"vendor_name\": \"n/a\"}]}}, \"data_type\": \"CVE\", \"references\": {\"reference_data\": [{\"url\": \"https://sku11army.blogspot.com/2020/01/heinberg-lantime-m1000-rce.html\", \"name\": \"https://sku11army.blogspot.com/2020/01/heinberg-lantime-m1000-rce.html\", \"refsource\": \"MISC\"}, {\"url\": \"https://sku11army.blogspot.com/2020/01/meinberg-lantime-m1000-rce.html\", \"name\": \"https://sku11army.blogspot.com/2020/01/meinberg-lantime-m1000-rce.html\", \"refsource\": \"MISC\"}, {\"url\": \"https://wolke.meinberg.de/index.php/s/dKP3PKgFXS6sPRE#pdfviewer\", \"name\": \"https://wolke.meinberg.de/index.php/s/dKP3PKgFXS6sPRE#pdfviewer\", \"refsource\": \"MISC\"}]}, \"data_format\": \"MITRE\", \"description\": {\"description_data\": [{\"lang\": \"eng\", \"value\": \"** DISPUTED ** Meinberg Lantime M300 and M1000 devices allow attackers (with privileges to configure a device) to execute arbitrary OS commands by editing the /config/netconf.cmd script (aka Extended Network Configuration). Note: According to the description, the vulnerability requires a fully authenticated super-user account using a webUI function that allows super users to edit a script supposed to execute OS commands. The given weakness enumeration (CWE-78) is not applicable in this case as it refers to abusing functions/input fields not supposed to be accepting OS commands by using \u0027Special Elements.\u0027\"}]}, \"problemtype\": {\"problemtype_data\": [{\"description\": [{\"lang\": \"eng\", \"value\": \"n/a\"}]}]}, \"data_version\": \"4.0\", \"CVE_data_meta\": {\"ID\": \"CVE-2020-7240\", \"STATE\": \"PUBLIC\", \"ASSIGNER\": \"cve@mitre.org\"}}}}",
"cveMetadata": "{\"cveId\": \"CVE-2020-7240\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-28T13:28:59.219Z\", \"dateReserved\": \"2020-01-20T00:00:00\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"datePublished\": \"2020-01-20T19:27:51\", \"assignerShortName\": \"mitre\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…