CVE-2020-7575 (GCVE-0-2020-7575)
Vulnerability from cvelistv5 – Published: 2020-04-14 19:50 – Updated: 2024-08-04 09:33- CWE-80 - Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Climatix POL908 (BACnet/IP module) |
Affected:
All versions
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T09:33:19.843Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-886514.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Climatix POL908 (BACnet/IP module)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "Climatix POL909 (AWM module)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V11.32"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions \u003c V11.32). A persistent cross-site scripting (XSS) vulnerability exists in the web server access log page of the affected devices that could allow an attacker to inject arbitrary JavaScript code via specially crafted GET requests. The code could be potentially executed later by another (privileged) user. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users\u0027 web sessions."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-80",
"description": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-02-09T15:38:21",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-886514.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-7575",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Climatix POL908 (BACnet/IP module)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "Climatix POL909 (AWM module)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V11.32"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions \u003c V11.32). A persistent cross-site scripting (XSS) vulnerability exists in the web server access log page of the affected devices that could allow an attacker to inject arbitrary JavaScript code via specially crafted GET requests. The code could be potentially executed later by another (privileged) user. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users\u0027 web sessions."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-886514.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-886514.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-7575",
"datePublished": "2020-04-14T19:50:54",
"dateReserved": "2020-01-21T00:00:00",
"dateUpdated": "2024-08-04T09:33:19.843Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:climatix_pol908_firmware:*:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"10406062-CF18-409F-825F-5C24F676E710\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:climatix_pol908:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"51BC0394-A0B0-4B0D-976C-84606340736A\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:siemens:climatix_pol909_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"11.32\", \"matchCriteriaId\": \"B6DF9014-C729-4CBF-8EBF-BBC960BFED12\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:siemens:climatix_pol909:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"256380A1-0197-4FED-AF9B-E05D59C7D1F1\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions \u003c V11.32). A persistent cross-site scripting (XSS) vulnerability exists in the web server access log page of the affected devices that could allow an attacker to inject arbitrary JavaScript code via specially crafted GET requests. The code could be potentially executed later by another (privileged) user. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users\u0027 web sessions.\"}, {\"lang\": \"es\", \"value\": \"Se ha identificado una vulnerabilidad en Climatix POL908 (m\\u00f3dulo BACnet/IP) (todas las versiones), Climatix POL909 (m\\u00f3dulo AWM) (todas las versiones anteriores a V11.32). Se presenta una vulnerabilidad de tipo cross-site scripting (XSS) persistente en la p\\u00e1gina de registro de acceso al servidor web de los dispositivos afectados que podr\\u00eda permitir a un atacante inyectar c\\u00f3digo JavaScript arbitrario por medio de peticiones GET especialmente dise\\u00f1adas. El c\\u00f3digo podr\\u00eda ser ejecutado posteriormente por otro usuario (privilegiado). La vulnerabilidad de seguridad podr\\u00eda ser explotada por un atacante con acceso de red al sistema afectado. Una explotaci\\u00f3n con \\u00e9xito no requiere privilegios system. Un atacante podr\\u00eda utilizar la vulnerabilidad para comprometer la confidencialidad e integridad de las sesiones web de otros usuarios.\"}]",
"id": "CVE-2020-7575",
"lastModified": "2024-11-21T05:37:24.323",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 6.1, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 2.7}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:N/I:P/A:N\", \"baseScore\": 4.3, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"MEDIUM\", \"exploitabilityScore\": 8.6, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
"published": "2020-04-14T20:15:15.543",
"references": "[{\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-886514.pdf\", \"source\": \"productcert@siemens.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://cert-portal.siemens.com/productcert/pdf/ssa-886514.pdf\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"productcert@siemens.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-80\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2020-7575\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2020-04-14T20:15:15.543\",\"lastModified\":\"2024-11-21T05:37:24.323\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions \u003c V11.32). A persistent cross-site scripting (XSS) vulnerability exists in the web server access log page of the affected devices that could allow an attacker to inject arbitrary JavaScript code via specially crafted GET requests. The code could be potentially executed later by another (privileged) user. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users\u0027 web sessions.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Climatix POL908 (m\u00f3dulo BACnet/IP) (todas las versiones), Climatix POL909 (m\u00f3dulo AWM) (todas las versiones anteriores a V11.32). Se presenta una vulnerabilidad de tipo cross-site scripting (XSS) persistente en la p\u00e1gina de registro de acceso al servidor web de los dispositivos afectados que podr\u00eda permitir a un atacante inyectar c\u00f3digo JavaScript arbitrario por medio de peticiones GET especialmente dise\u00f1adas. El c\u00f3digo podr\u00eda ser ejecutado posteriormente por otro usuario (privilegiado). La vulnerabilidad de seguridad podr\u00eda ser explotada por un atacante con acceso de red al sistema afectado. Una explotaci\u00f3n con \u00e9xito no requiere privilegios system. Un atacante podr\u00eda utilizar la vulnerabilidad para comprometer la confidencialidad e integridad de las sesiones web de otros usuarios.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":6.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.8,\"impactScore\":2.7}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:P/A:N\",\"baseScore\":4.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-80\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:climatix_pol908_firmware:*:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"10406062-CF18-409F-825F-5C24F676E710\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:climatix_pol908:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"51BC0394-A0B0-4B0D-976C-84606340736A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:climatix_pol909_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"11.32\",\"matchCriteriaId\":\"B6DF9014-C729-4CBF-8EBF-BBC960BFED12\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:climatix_pol909:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"256380A1-0197-4FED-AF9B-E05D59C7D1F1\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-886514.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-886514.pdf\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
CERTFR-2020-AVI-207
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SIMATIC RF180C | ||
| Siemens | N/A | SCALANCE X-200IRT | ||
| Siemens | N/A | SCALANCE X-300 | ||
| Siemens | N/A | SCALANCE S615 versions antérieures à V6.1 | ||
| Siemens | N/A | SIMATIC PN/PN Coupler | ||
| Siemens | N/A | Climatix POL908 | ||
| Siemens | N/A | SIMATIC CP 1242-7 versions antérieures à V3.2 | ||
| Siemens | N/A | INEMA Remote Connect Server versions antérieures à V2.1 | ||
| Siemens | N/A | APOGEE PXC versions antérieures ou égales à V3.0 | ||
| Siemens | N/A | SINAMICS S/G Control Unit w. PROFINET | ||
| Siemens | N/A | TIM 3V-IE Advanced versions antérieures à V2.8 | ||
| Siemens | N/A | SIMATIC S7-1500 Software Controller versions antérieures à V20.8 | ||
| Siemens | N/A | SIMATIC RF186CI | ||
| Siemens | N/A | SIMATIC CP 1543-1 versions antérieures à V2.2 | ||
| Siemens | N/A | Desigo PXM20 (Power PC) versions antérieures ou égales à V2.3x | ||
| Siemens | N/A | SIMATIC S7-400 PN/DP V7 | ||
| Siemens | N/A | APOGEE MEC/MBC/PXC (P2) versions antérieures à V2.8.2 | ||
| Siemens | N/A | SIMATIC RF188CI | ||
| Siemens | N/A | SIMATIC ET200MP IM155-5 PN HF | ||
| Siemens | N/A | SIMATIC CP 1543SP-1 versions antérieures à V2.1 | ||
| Siemens | N/A | SIMATIC S7-410 CPU | ||
| Siemens | N/A | RUGGEDCOM RM1224 versions antérieures à V6.1 | ||
| Siemens | N/A | SIDOOR ATE531S | ||
| Siemens | N/A | SIMATIC ET200SP IM155-6 PN/2 HF | ||
| Siemens | N/A | SIMATIC TDC CP51M1 | ||
| Siemens | N/A | SIMATIC ET200SP IM155-6 MF HF | ||
| Siemens | N/A | SIMATIC ET200SP IM155-6 PN HA | ||
| Siemens | N/A | SIMATIC CP 1243-7 LTE US versions antérieures à V3.2 | ||
| Siemens | N/A | SIMATIC CP 1542SP-1 IRC versions antérieures à V2.1 | ||
| Siemens | N/A | SIMATIC ET200SP IM155-6 PN HF | ||
| Siemens | N/A | TIM 3V-IE DNP3 versions antérieures à V3.3 | ||
| Siemens | N/A | SIMATIC CP 443-1 Advanced | ||
| Siemens | N/A | KTK ATE530S | ||
| Siemens | N/A | SIMATIC CP 1243-8 IRC versions antérieures à V3.2 | ||
| Siemens | N/A | SIMATIC RF186C | ||
| Siemens | N/A | SCALANCE W700 IEEE 802.11a/b/g/n versions antérieures à V6.4 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU family versions antérieures à V2.8 | ||
| Siemens | N/A | TALON TC Series (BACnet) versions antérieures ou égales à V3.0 | ||
| Siemens | N/A | SIMATIC RF185C | ||
| Siemens | N/A | SIMATIC ET 200SP Open Controller CPU1515SP PC2 versions antérieures à V20.8 | ||
| Siemens | N/A | TIM 4R-IE DNP3 versions antérieures à V3.3 | ||
| Siemens | N/A | SIMATIC WinAC RTX (F) 2010 | ||
| Siemens | N/A | SIDOOR ATE530S COATED | ||
| Siemens | N/A | SIMATIC S7-300 CPU | ||
| Siemens | N/A | Climatix POL909 | ||
| Siemens | N/A | SIMATIC ET 200SP Open Controller CPU1515SP PC versions antérieures à V2.1.7 | ||
| Siemens | N/A | SIMATIC ET200SP IM155-6 PN/3 HF | ||
| Siemens | N/A | IE/PB-Link V3 | ||
| Siemens | N/A | SIMOTICS CONNECT 400 versions antérieures à V0.3.0.330 | ||
| Siemens | N/A | TIM 4R-IE versions antérieures à V2.8 | ||
| Siemens | N/A | APOGEE PXC Series (P2) versions antérieures ou égales à V2.8.2 | ||
| Siemens | N/A | SCALANCE W1700 IEEE 802.11ac versions antérieures à V2.0 | ||
| Siemens | N/A | SCALANCE M-800 versions antérieures à V6.1 | ||
| Siemens | N/A | SCALANCE SC-600 versions antérieures à V2.0 | ||
| Siemens | N/A | Desigo PXC (Power PC) versions antérieures ou égales à V2.3x | ||
| Siemens | N/A | SIDOOR ATD430W | ||
| Siemens | N/A | SIMATIC CP 1243-1 versions antérieures à V3.2 | ||
| Siemens | N/A | SIMATIC RF188C | ||
| Siemens | N/A | SIMATIC CP 1243-7 LTE EU versions antérieures à V3.2 | ||
| Siemens | N/A | RUGGEDCOM ROX II versions antérieures à V2.13.3 | ||
| Siemens | N/A | SIMATIC CP 1542SP-1 versions antérieures à V2.1 | ||
| Siemens | N/A | SIMATIC TDC CPU555 | ||
| Siemens | N/A | SIMATIC CP 443-1 | ||
| Siemens | N/A | SIMATIC MICRO-DRIVE PDC | ||
| Siemens | N/A | TIM 3V-IE versions antérieures à V2.8 | ||
| Siemens | N/A | SIMATIC RF182C | ||
| Siemens | N/A | SCALANCE X-200 |
| Title | Publication Time | Tags | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SIMATIC RF180C",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X-200IRT",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X-300",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE S615 versions ant\u00e9rieures \u00e0 V6.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PN/PN Coupler",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Climatix POL908",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1242-7 versions ant\u00e9rieures \u00e0 V3.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "INEMA Remote Connect Server versions ant\u00e9rieures \u00e0 V2.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC versions ant\u00e9rieures ou \u00e9gales \u00e0 V3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS S/G Control Unit w. PROFINET",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 3V-IE Advanced versions ant\u00e9rieures \u00e0 V2.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 Software Controller versions ant\u00e9rieures \u00e0 V20.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF186CI",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1543-1 versions ant\u00e9rieures \u00e0 V2.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXM20 (Power PC) versions ant\u00e9rieures ou \u00e9gales \u00e0 V2.3x",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-400 PN/DP V7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE MEC/MBC/PXC (P2) versions ant\u00e9rieures \u00e0 V2.8.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF188CI",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET200MP IM155-5 PN HF",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1543SP-1 versions ant\u00e9rieures \u00e0 V2.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-410 CPU",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RM1224 versions ant\u00e9rieures \u00e0 V6.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIDOOR ATE531S",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET200SP IM155-6 PN/2 HF",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC TDC CP51M1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET200SP IM155-6 MF HF",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET200SP IM155-6 PN HA",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1243-7 LTE US versions ant\u00e9rieures \u00e0 V3.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1542SP-1 IRC versions ant\u00e9rieures \u00e0 V2.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET200SP IM155-6 PN HF",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 3V-IE DNP3 versions ant\u00e9rieures \u00e0 V3.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 443-1 Advanced",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "KTK ATE530S",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1243-8 IRC versions ant\u00e9rieures \u00e0 V3.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF186C",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W700 IEEE 802.11a/b/g/n versions ant\u00e9rieures \u00e0 V6.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU family versions ant\u00e9rieures \u00e0 V2.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TALON TC Series (BACnet) versions ant\u00e9rieures ou \u00e9gales \u00e0 V3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF185C",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200SP Open Controller CPU1515SP PC2 versions ant\u00e9rieures \u00e0 V20.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 4R-IE DNP3 versions ant\u00e9rieures \u00e0 V3.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinAC RTX (F) 2010",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIDOOR ATE530S COATED",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Climatix POL909",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200SP Open Controller CPU1515SP PC versions ant\u00e9rieures \u00e0 V2.1.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET200SP IM155-6 PN/3 HF",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "IE/PB-Link V3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOTICS CONNECT 400 versions ant\u00e9rieures \u00e0 V0.3.0.330",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 4R-IE versions ant\u00e9rieures \u00e0 V2.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC Series (P2) versions ant\u00e9rieures ou \u00e9gales \u00e0 V2.8.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1700 IEEE 802.11ac versions ant\u00e9rieures \u00e0 V2.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE M-800 versions ant\u00e9rieures \u00e0 V6.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE SC-600 versions ant\u00e9rieures \u00e0 V2.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC (Power PC) versions ant\u00e9rieures ou \u00e9gales \u00e0 V2.3x",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIDOOR ATD430W",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1243-1 versions ant\u00e9rieures \u00e0 V3.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF188C",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1243-7 LTE EU versions ant\u00e9rieures \u00e0 V3.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX II versions ant\u00e9rieures \u00e0 V2.13.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1542SP-1 versions ant\u00e9rieures \u00e0 V2.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC TDC CPU555",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 443-1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MICRO-DRIVE PDC",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 3V-IE versions ant\u00e9rieures \u00e0 V2.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF182C",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X-200",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2018-5391",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-5391"
},
{
"name": "CVE-2020-7575",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7575"
},
{
"name": "CVE-2020-7574",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7574"
},
{
"name": "CVE-2019-13939",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13939"
},
{
"name": "CVE-2018-5390",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-5390"
},
{
"name": "CVE-2019-10939",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10939"
},
{
"name": "CVE-2019-19300",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19300"
},
{
"name": "CVE-2019-19301",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19301"
}
],
"links": [],
"reference": "CERTFR-2020-AVI-207",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2020-04-14T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-886514 du 14 avril 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-886514.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-102233 du 14 avril 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-102233.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-359303 du 14 avril 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-359303.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-162506 du 14 avril 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162506.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-593272 du 14 avril 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-593272.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-377115 du 14 avril 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-377115.pdf"
}
]
}
CERTFR-2020-AVI-207
Vulnerability from certfr_avis - Published: - Updated:
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SIMATIC RF180C | ||
| Siemens | N/A | SCALANCE X-200IRT | ||
| Siemens | N/A | SCALANCE X-300 | ||
| Siemens | N/A | SCALANCE S615 versions antérieures à V6.1 | ||
| Siemens | N/A | SIMATIC PN/PN Coupler | ||
| Siemens | N/A | Climatix POL908 | ||
| Siemens | N/A | SIMATIC CP 1242-7 versions antérieures à V3.2 | ||
| Siemens | N/A | INEMA Remote Connect Server versions antérieures à V2.1 | ||
| Siemens | N/A | APOGEE PXC versions antérieures ou égales à V3.0 | ||
| Siemens | N/A | SINAMICS S/G Control Unit w. PROFINET | ||
| Siemens | N/A | TIM 3V-IE Advanced versions antérieures à V2.8 | ||
| Siemens | N/A | SIMATIC S7-1500 Software Controller versions antérieures à V20.8 | ||
| Siemens | N/A | SIMATIC RF186CI | ||
| Siemens | N/A | SIMATIC CP 1543-1 versions antérieures à V2.2 | ||
| Siemens | N/A | Desigo PXM20 (Power PC) versions antérieures ou égales à V2.3x | ||
| Siemens | N/A | SIMATIC S7-400 PN/DP V7 | ||
| Siemens | N/A | APOGEE MEC/MBC/PXC (P2) versions antérieures à V2.8.2 | ||
| Siemens | N/A | SIMATIC RF188CI | ||
| Siemens | N/A | SIMATIC ET200MP IM155-5 PN HF | ||
| Siemens | N/A | SIMATIC CP 1543SP-1 versions antérieures à V2.1 | ||
| Siemens | N/A | SIMATIC S7-410 CPU | ||
| Siemens | N/A | RUGGEDCOM RM1224 versions antérieures à V6.1 | ||
| Siemens | N/A | SIDOOR ATE531S | ||
| Siemens | N/A | SIMATIC ET200SP IM155-6 PN/2 HF | ||
| Siemens | N/A | SIMATIC TDC CP51M1 | ||
| Siemens | N/A | SIMATIC ET200SP IM155-6 MF HF | ||
| Siemens | N/A | SIMATIC ET200SP IM155-6 PN HA | ||
| Siemens | N/A | SIMATIC CP 1243-7 LTE US versions antérieures à V3.2 | ||
| Siemens | N/A | SIMATIC CP 1542SP-1 IRC versions antérieures à V2.1 | ||
| Siemens | N/A | SIMATIC ET200SP IM155-6 PN HF | ||
| Siemens | N/A | TIM 3V-IE DNP3 versions antérieures à V3.3 | ||
| Siemens | N/A | SIMATIC CP 443-1 Advanced | ||
| Siemens | N/A | KTK ATE530S | ||
| Siemens | N/A | SIMATIC CP 1243-8 IRC versions antérieures à V3.2 | ||
| Siemens | N/A | SIMATIC RF186C | ||
| Siemens | N/A | SCALANCE W700 IEEE 802.11a/b/g/n versions antérieures à V6.4 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU family versions antérieures à V2.8 | ||
| Siemens | N/A | TALON TC Series (BACnet) versions antérieures ou égales à V3.0 | ||
| Siemens | N/A | SIMATIC RF185C | ||
| Siemens | N/A | SIMATIC ET 200SP Open Controller CPU1515SP PC2 versions antérieures à V20.8 | ||
| Siemens | N/A | TIM 4R-IE DNP3 versions antérieures à V3.3 | ||
| Siemens | N/A | SIMATIC WinAC RTX (F) 2010 | ||
| Siemens | N/A | SIDOOR ATE530S COATED | ||
| Siemens | N/A | SIMATIC S7-300 CPU | ||
| Siemens | N/A | Climatix POL909 | ||
| Siemens | N/A | SIMATIC ET 200SP Open Controller CPU1515SP PC versions antérieures à V2.1.7 | ||
| Siemens | N/A | SIMATIC ET200SP IM155-6 PN/3 HF | ||
| Siemens | N/A | IE/PB-Link V3 | ||
| Siemens | N/A | SIMOTICS CONNECT 400 versions antérieures à V0.3.0.330 | ||
| Siemens | N/A | TIM 4R-IE versions antérieures à V2.8 | ||
| Siemens | N/A | APOGEE PXC Series (P2) versions antérieures ou égales à V2.8.2 | ||
| Siemens | N/A | SCALANCE W1700 IEEE 802.11ac versions antérieures à V2.0 | ||
| Siemens | N/A | SCALANCE M-800 versions antérieures à V6.1 | ||
| Siemens | N/A | SCALANCE SC-600 versions antérieures à V2.0 | ||
| Siemens | N/A | Desigo PXC (Power PC) versions antérieures ou égales à V2.3x | ||
| Siemens | N/A | SIDOOR ATD430W | ||
| Siemens | N/A | SIMATIC CP 1243-1 versions antérieures à V3.2 | ||
| Siemens | N/A | SIMATIC RF188C | ||
| Siemens | N/A | SIMATIC CP 1243-7 LTE EU versions antérieures à V3.2 | ||
| Siemens | N/A | RUGGEDCOM ROX II versions antérieures à V2.13.3 | ||
| Siemens | N/A | SIMATIC CP 1542SP-1 versions antérieures à V2.1 | ||
| Siemens | N/A | SIMATIC TDC CPU555 | ||
| Siemens | N/A | SIMATIC CP 443-1 | ||
| Siemens | N/A | SIMATIC MICRO-DRIVE PDC | ||
| Siemens | N/A | TIM 3V-IE versions antérieures à V2.8 | ||
| Siemens | N/A | SIMATIC RF182C | ||
| Siemens | N/A | SCALANCE X-200 |
| Title | Publication Time | Tags | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SIMATIC RF180C",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X-200IRT",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X-300",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE S615 versions ant\u00e9rieures \u00e0 V6.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PN/PN Coupler",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Climatix POL908",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1242-7 versions ant\u00e9rieures \u00e0 V3.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "INEMA Remote Connect Server versions ant\u00e9rieures \u00e0 V2.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC versions ant\u00e9rieures ou \u00e9gales \u00e0 V3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS S/G Control Unit w. PROFINET",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 3V-IE Advanced versions ant\u00e9rieures \u00e0 V2.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 Software Controller versions ant\u00e9rieures \u00e0 V20.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF186CI",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1543-1 versions ant\u00e9rieures \u00e0 V2.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXM20 (Power PC) versions ant\u00e9rieures ou \u00e9gales \u00e0 V2.3x",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-400 PN/DP V7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE MEC/MBC/PXC (P2) versions ant\u00e9rieures \u00e0 V2.8.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF188CI",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET200MP IM155-5 PN HF",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1543SP-1 versions ant\u00e9rieures \u00e0 V2.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-410 CPU",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RM1224 versions ant\u00e9rieures \u00e0 V6.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIDOOR ATE531S",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET200SP IM155-6 PN/2 HF",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC TDC CP51M1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET200SP IM155-6 MF HF",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET200SP IM155-6 PN HA",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1243-7 LTE US versions ant\u00e9rieures \u00e0 V3.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1542SP-1 IRC versions ant\u00e9rieures \u00e0 V2.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET200SP IM155-6 PN HF",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 3V-IE DNP3 versions ant\u00e9rieures \u00e0 V3.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 443-1 Advanced",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "KTK ATE530S",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1243-8 IRC versions ant\u00e9rieures \u00e0 V3.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF186C",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W700 IEEE 802.11a/b/g/n versions ant\u00e9rieures \u00e0 V6.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU family versions ant\u00e9rieures \u00e0 V2.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TALON TC Series (BACnet) versions ant\u00e9rieures ou \u00e9gales \u00e0 V3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF185C",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200SP Open Controller CPU1515SP PC2 versions ant\u00e9rieures \u00e0 V20.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 4R-IE DNP3 versions ant\u00e9rieures \u00e0 V3.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinAC RTX (F) 2010",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIDOOR ATE530S COATED",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Climatix POL909",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200SP Open Controller CPU1515SP PC versions ant\u00e9rieures \u00e0 V2.1.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET200SP IM155-6 PN/3 HF",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "IE/PB-Link V3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOTICS CONNECT 400 versions ant\u00e9rieures \u00e0 V0.3.0.330",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 4R-IE versions ant\u00e9rieures \u00e0 V2.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC Series (P2) versions ant\u00e9rieures ou \u00e9gales \u00e0 V2.8.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1700 IEEE 802.11ac versions ant\u00e9rieures \u00e0 V2.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE M-800 versions ant\u00e9rieures \u00e0 V6.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE SC-600 versions ant\u00e9rieures \u00e0 V2.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC (Power PC) versions ant\u00e9rieures ou \u00e9gales \u00e0 V2.3x",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIDOOR ATD430W",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1243-1 versions ant\u00e9rieures \u00e0 V3.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF188C",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1243-7 LTE EU versions ant\u00e9rieures \u00e0 V3.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX II versions ant\u00e9rieures \u00e0 V2.13.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1542SP-1 versions ant\u00e9rieures \u00e0 V2.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC TDC CPU555",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 443-1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MICRO-DRIVE PDC",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 3V-IE versions ant\u00e9rieures \u00e0 V2.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF182C",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X-200",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2018-5391",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-5391"
},
{
"name": "CVE-2020-7575",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7575"
},
{
"name": "CVE-2020-7574",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7574"
},
{
"name": "CVE-2019-13939",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-13939"
},
{
"name": "CVE-2018-5390",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-5390"
},
{
"name": "CVE-2019-10939",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10939"
},
{
"name": "CVE-2019-19300",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19300"
},
{
"name": "CVE-2019-19301",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19301"
}
],
"links": [],
"reference": "CERTFR-2020-AVI-207",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2020-04-14T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-886514 du 14 avril 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-886514.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-102233 du 14 avril 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-102233.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-359303 du 14 avril 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-359303.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-162506 du 14 avril 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-162506.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-593272 du 14 avril 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-593272.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-377115 du 14 avril 2020",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-377115.pdf"
}
]
}
ICSA-20-105-04
Vulnerability from csaf_cisa - Published: 2020-04-14 00:00 - Updated: 2021-02-09 00:00Notes
{
"document": {
"acknowledgments": [
{
"names": [
"Ezequiel Fernandez"
],
"organization": "Dreamlab Technologies",
"summary": "reporting these vulnerabilities to Siemens"
}
],
"category": "csaf_security_advisory",
"csaf_version": "2.0",
"distribution": {
"text": "Disclosure is not limited",
"tlp": {
"label": "WHITE",
"url": "https://us-cert.cisa.gov/tlp/"
}
},
"lang": "en-US",
"notes": [
{
"category": "general",
"text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov",
"title": "CISA Disclaimer"
},
{
"category": "legal_disclaimer",
"text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.",
"title": "Legal Notice"
},
{
"category": "summary",
"text": "Successful exploitation of these vulnerabilities could allow a remote attacker to execute arbitrary code to access confidential information without authentication.",
"title": "Risk evaluation"
},
{
"category": "other",
"text": "Commercial Facilities",
"title": "Critical infrastructure sectors"
},
{
"category": "other",
"text": "Worldwide",
"title": "Countries/areas deployed"
},
{
"category": "other",
"text": "Germany",
"title": "Company headquarters location"
},
{
"category": "general",
"text": "CISA recommends users take the following measures to protect themselves from social engineering attacks:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.",
"title": "Recommended Practices"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and \nsolutions, please contact the Siemens ProductCERT:\n\nhttps://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "general",
"text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories",
"title": "Additional Resources"
},
{
"category": "other",
"text": "No known public exploits specifically target these vulnerabilities.",
"title": "Exploitability"
}
],
"publisher": {
"category": "coordinator",
"contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870",
"name": "CISA",
"namespace": "https://www.cisa.gov/"
},
"references": [
{
"category": "self",
"summary": "ICS Advisory ICSA-20-105-04 JSON",
"url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2020/icsa-20-105-04.json"
},
{
"category": "self",
"summary": "ICS Advisory ICSA-20-105-04 Web Version",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-20-105-04"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ics/alerts/ICS-ALERT-10-301-01"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"
},
{
"category": "external",
"summary": "Recommended Practices",
"url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B"
},
{
"category": "external",
"summary": "SSA-496604: SSA-886514: Persistent XSS Vulnerabilities in the Web Interface of Climatix POL908 and POL909 Modules - TXT Version",
"url": "https://cert-portal.siemens.com/productcert/txt/SSA-886514.txt"
}
],
"title": "Siemens Climatix (Update A)",
"tracking": {
"current_release_date": "2021-02-09T00:00:00.000000Z",
"generator": {
"engine": {
"name": "CISA CSAF Generator",
"version": "1.0.0"
}
},
"id": "ICSA-20-105-04",
"initial_release_date": "2020-04-14T00:00:00.000000Z",
"revision_history": [
{
"date": "2020-04-14T00:00:00.000000Z",
"legacy_version": "Initial",
"number": "1",
"summary": "ICSA-20-105-04 Siemens Climatix"
},
{
"date": "2021-02-09T00:00:00.000000Z",
"legacy_version": "A",
"number": "2",
"summary": "ICSA-20-105-04 Siemens Climatix (Update A)"
}
],
"status": "final",
"version": "2"
}
},
"product_tree": {
"branches": [
{
"branches": [
{
"branches": [
{
"category": "product_version_range",
"name": "All versions",
"product": {
"name": "Climatix POL908 (BACnet/IP module): All versions",
"product_id": "CSAFPID-0001"
}
}
],
"category": "product_name",
"name": "Climatix POL908 (BACnet/IP module)"
},
{
"branches": [
{
"category": "product_version_range",
"name": "All versions \u003c V11.32",
"product": {
"name": "Climatix POL909 (AWM module): All versions \u003c V11.32",
"product_id": "CSAFPID-0002"
}
}
],
"category": "product_name",
"name": "Climatix POL909 (AWM module)"
}
],
"category": "vendor",
"name": "Siemens"
}
]
},
"vulnerabilities": [
{
"cve": "CVE-2020-7574",
"cwe": {
"id": "CWE-79",
"name": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
},
"notes": [
{
"category": "summary",
"text": "A persistent cross-site scripting (XSS) vulnerability exists in the \"Server Config\" web interface of the affected devices that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user.",
"title": "Summary"
},
{
"category": "summary",
"text": "The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users\u0027 web session.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "https://support.industry.siemens.com/cs/ww/en/view/109747351 (login",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109747351"
},
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7574"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update Climatix POL908 and POL909 to V11.22 or later version. These\nversions disable the web interface by default, as it is no longer needed\nin standard use cases.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Climatix POL908 is designed to be operated in protected BACnet/IP\nnetworks only. Do not connect it to other networks, such as an Office\nLAN or the Internet. Also consider to remove POL908, in case the\nintegrated BACnet/IP implementation in newer versions of Climatix 600\ncontrollers is already sufficient for your environment.\n\n_The remaining mitigation measures apply only, if the web interface is\nactivated (e.g.\u00a0via the Climatix SCOPE tool):_",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Climatix POL909: When configuring your custom web application, disable\nthe access to the default web pages provided by POL909",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Enforce authentication for the web interface, and change the default\npassword of the standard ADMIN user",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Disable JavaScript within the web browser used to access the web server\nof Climatix POL908",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Utilize a modern web browser with integrated XSS filtering mechanisms",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "See recommendations from section Workarounds and Mitigations ",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V11.32 - Download: https://support.industry.siemens.com/cs/ww/en/view/109747351 (login required) ",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109747351"
},
{
"category": "mitigation",
"details": "As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
},
{
"cve": "CVE-2020-7575",
"cwe": {
"id": "CWE-80",
"name": "Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
},
"notes": [
{
"category": "summary",
"text": "A persistent cross-site scripting (XSS) vulnerability exists in the web server access log page of the affected devices that could allow an attacker to inject arbitrary JavaScript code via specially crafted GET requests. The code could be potentially executed later by another (privileged) user.",
"title": "Summary"
},
{
"category": "summary",
"text": "The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users\u0027 web sessions.",
"title": "Summary"
}
],
"product_status": {
"known_affected": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
"references": [
{
"category": "external",
"summary": "https://support.industry.siemens.com/cs/ww/en/view/109747351 (login",
"url": "https://support.industry.siemens.com/cs/ww/en/view/109747351"
},
{
"category": "external",
"summary": "web.nvd.nist.gov",
"url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2020-7575"
},
{
"category": "external",
"summary": "www.first.org",
"url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N"
}
],
"remediations": [
{
"category": "vendor_fix",
"details": "Update Climatix POL908 and POL909 to V11.22 or later version. These\nversions disable the web interface by default, as it is no longer needed\nin standard use cases.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Climatix POL908 is designed to be operated in protected BACnet/IP\nnetworks only. Do not connect it to other networks, such as an Office\nLAN or the Internet. Also consider to remove POL908, in case the\nintegrated BACnet/IP implementation in newer versions of Climatix 600\ncontrollers is already sufficient for your environment.\n\n_The remaining mitigation measures apply only, if the web interface is\nactivated (e.g.\u00a0via the Climatix SCOPE tool):_",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Climatix POL909: When configuring your custom web application, disable\nthe access to the default web pages provided by POL909",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Enforce authentication for the web interface, and change the default\npassword of the standard ADMIN user",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Disable JavaScript within the web browser used to access the web server\nof Climatix POL908",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "Utilize a modern web browser with integrated XSS filtering mechanisms",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
},
{
"category": "vendor_fix",
"details": "See recommendations from section Workarounds and Mitigations ",
"product_ids": [
"CSAFPID-0001"
]
},
{
"category": "vendor_fix",
"details": "Update to V11.32 - Download: https://support.industry.siemens.com/cs/ww/en/view/109747351 (login required) ",
"product_ids": [
"CSAFPID-0002"
],
"url": "https://support.industry.siemens.com/cs/ww/en/view/109747351"
},
{
"category": "mitigation",
"details": "As a general security measure Siemens strongly recommends to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.",
"product_ids": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
],
"scores": [
{
"cvss_v3": {
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N/E:P/RL:T/RC:C",
"version": "3.1"
},
"products": [
"CSAFPID-0001",
"CSAFPID-0002"
]
}
]
}
]
}
GHSA-X224-39VW-8RH7
Vulnerability from github – Published: 2022-05-24 17:14 – Updated: 2022-05-24 17:14A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions). A persistent cross-site scripting (XSS) vulnerability exists in the web server access log page of the affected devices that could allow an attacker to inject arbitrary JavaScript code via specially crafted GET requests. The code could be potentially executed later by another (privileged) user. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users' web sessions.
{
"affected": [],
"aliases": [
"CVE-2020-7575"
],
"database_specific": {
"cwe_ids": [
"CWE-79"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2020-04-14T20:15:00Z",
"severity": "MODERATE"
},
"details": "A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions). A persistent cross-site scripting (XSS) vulnerability exists in the web server access log page of the affected devices that could allow an attacker to inject arbitrary JavaScript code via specially crafted GET requests. The code could be potentially executed later by another (privileged) user. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users\u0027 web sessions.",
"id": "GHSA-x224-39vw-8rh7",
"modified": "2022-05-24T17:14:17Z",
"published": "2022-05-24T17:14:17Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2020-7575"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-886514.pdf"
}
],
"schema_version": "1.4.0",
"severity": []
}
FKIE_CVE-2020-7575
Vulnerability from fkie_nvd - Published: 2020-04-14 20:15 - Updated: 2024-11-21 05:37| Vendor | Product | Version | |
|---|---|---|---|
| siemens | climatix_pol908_firmware | * | |
| siemens | climatix_pol908 | - | |
| siemens | climatix_pol909_firmware | * | |
| siemens | climatix_pol909 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:climatix_pol908_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "10406062-CF18-409F-825F-5C24F676E710",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:climatix_pol908:-:*:*:*:*:*:*:*",
"matchCriteriaId": "51BC0394-A0B0-4B0D-976C-84606340736A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:climatix_pol909_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B6DF9014-C729-4CBF-8EBF-BBC960BFED12",
"versionEndExcluding": "11.32",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:climatix_pol909:-:*:*:*:*:*:*:*",
"matchCriteriaId": "256380A1-0197-4FED-AF9B-E05D59C7D1F1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions \u003c V11.32). A persistent cross-site scripting (XSS) vulnerability exists in the web server access log page of the affected devices that could allow an attacker to inject arbitrary JavaScript code via specially crafted GET requests. The code could be potentially executed later by another (privileged) user. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users\u0027 web sessions."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Climatix POL908 (m\u00f3dulo BACnet/IP) (todas las versiones), Climatix POL909 (m\u00f3dulo AWM) (todas las versiones anteriores a V11.32). Se presenta una vulnerabilidad de tipo cross-site scripting (XSS) persistente en la p\u00e1gina de registro de acceso al servidor web de los dispositivos afectados que podr\u00eda permitir a un atacante inyectar c\u00f3digo JavaScript arbitrario por medio de peticiones GET especialmente dise\u00f1adas. El c\u00f3digo podr\u00eda ser ejecutado posteriormente por otro usuario (privilegiado). La vulnerabilidad de seguridad podr\u00eda ser explotada por un atacante con acceso de red al sistema afectado. Una explotaci\u00f3n con \u00e9xito no requiere privilegios system. Un atacante podr\u00eda utilizar la vulnerabilidad para comprometer la confidencialidad e integridad de las sesiones web de otros usuarios."
}
],
"id": "CVE-2020-7575",
"lastModified": "2024-11-21T05:37:24.323",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-04-14T20:15:15.543",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-886514.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-886514.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-80"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
GSD-2020-7575
Vulnerability from gsd - Updated: 2023-12-13 01:21{
"GSD": {
"alias": "CVE-2020-7575",
"description": "A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions \u003c V11.32). A persistent cross-site scripting (XSS) vulnerability exists in the web server access log page of the affected devices that could allow an attacker to inject arbitrary JavaScript code via specially crafted GET requests. The code could be potentially executed later by another (privileged) user. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users\u0027 web sessions.",
"id": "GSD-2020-7575"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2020-7575"
],
"details": "A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions \u003c V11.32). A persistent cross-site scripting (XSS) vulnerability exists in the web server access log page of the affected devices that could allow an attacker to inject arbitrary JavaScript code via specially crafted GET requests. The code could be potentially executed later by another (privileged) user. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users\u0027 web sessions.",
"id": "GSD-2020-7575",
"modified": "2023-12-13T01:21:52.190296Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-7575",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Climatix POL908 (BACnet/IP module)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "Climatix POL909 (AWM module)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V11.32"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions \u003c V11.32). A persistent cross-site scripting (XSS) vulnerability exists in the web server access log page of the affected devices that could allow an attacker to inject arbitrary JavaScript code via specially crafted GET requests. The code could be potentially executed later by another (privileged) user. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users\u0027 web sessions."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-886514.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-886514.pdf"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:climatix_pol908_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:climatix_pol908:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:climatix_pol909_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "11.32",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:climatix_pol909:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-7575"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions \u003c V11.32). A persistent cross-site scripting (XSS) vulnerability exists in the web server access log page of the affected devices that could allow an attacker to inject arbitrary JavaScript code via specially crafted GET requests. The code could be potentially executed later by another (privileged) user. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users\u0027 web sessions."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-886514.pdf",
"refsource": "MISC",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-886514.pdf"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": true
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7
}
},
"lastModifiedDate": "2021-03-04T20:26Z",
"publishedDate": "2020-04-14T20:15Z"
}
}
}
VAR-202004-1862
Vulnerability from variot - Updated: 2023-12-18 13:18A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions < V11.32). A persistent cross-site scripting (XSS) vulnerability exists in the web server access log page of the affected devices that could allow an attacker to inject arbitrary JavaScript code via specially crafted GET requests. The code could be potentially executed later by another (privileged) user. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users' web sessions. Multiple Siemens products contain cross-site scripting vulnerabilities.Information may be obtained and tampered with
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202004-1862",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "climatix pol908",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "*"
},
{
"model": "climatix pol909",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "11.32"
},
{
"model": "climatix pol908",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
},
{
"model": "climatix pol909",
"scope": null,
"trust": 0.8,
"vendor": "siemens",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-003560"
},
{
"db": "NVD",
"id": "CVE-2020-7575"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:climatix_pol908_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:climatix_pol908:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:climatix_pol909_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "11.32",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:climatix_pol909:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2020-7575"
}
]
},
"cve": "CVE-2020-7575",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"integrityImpact": "PARTIAL",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"trust": 1.0,
"userInteractionRequired": true,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Medium",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 4.3,
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "JVNDB-2020-003560",
"impactScore": null,
"integrityImpact": "Partial",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "Medium",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"trust": 1.0,
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "None",
"baseScore": 6.1,
"baseSeverity": "Medium",
"confidentialityImpact": "Low",
"exploitabilityScore": null,
"id": "JVNDB-2020-003560",
"impactScore": null,
"integrityImpact": "Low",
"privilegesRequired": "None",
"scope": "Changed",
"trust": 0.8,
"userInteraction": "Required",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2020-7575",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "JVNDB-2020-003560",
"trust": 0.8,
"value": "Medium"
},
{
"author": "CNNVD",
"id": "CNNVD-202004-932",
"trust": 0.6,
"value": "MEDIUM"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-003560"
},
{
"db": "NVD",
"id": "CVE-2020-7575"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-932"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in Climatix POL908 (BACnet/IP module) (All versions), Climatix POL909 (AWM module) (All versions \u003c V11.32). A persistent cross-site scripting (XSS) vulnerability exists in the web server access log page of the affected devices that could allow an attacker to inject arbitrary JavaScript code via specially crafted GET requests. The code could be potentially executed later by another (privileged) user. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires no system privileges. An attacker could use the vulnerability to compromise the confidentiality and integrity of other users\u0027 web sessions. Multiple Siemens products contain cross-site scripting vulnerabilities.Information may be obtained and tampered with",
"sources": [
{
"db": "NVD",
"id": "CVE-2020-7575"
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003560"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2020-7575",
"trust": 2.4
},
{
"db": "SIEMENS",
"id": "SSA-886514",
"trust": 1.6
},
{
"db": "ICS CERT",
"id": "ICSA-20-105-04",
"trust": 1.4
},
{
"db": "JVN",
"id": "JVNVU95499848",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2020-003560",
"trust": 0.8
},
{
"db": "AUSCERT",
"id": "ESB-2020.1314",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202004-932",
"trust": 0.6
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-003560"
},
{
"db": "NVD",
"id": "CVE-2020-7575"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-932"
}
]
},
"id": "VAR-202004-1862",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.14583333
},
"last_update_date": "2023-12-18T13:18:17.968000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-886514",
"trust": 0.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-886514.pdf"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-003560"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-79",
"trust": 1.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-003560"
},
{
"db": "NVD",
"id": "CVE-2020-7575"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.6,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-886514.pdf"
},
{
"trust": 1.4,
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-105-04"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2020-7575"
},
{
"trust": 0.8,
"url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2020-7575"
},
{
"trust": 0.8,
"url": "http://jvn.jp/vu/jvnvu95499848/index.html"
},
{
"trust": 0.6,
"url": "https://www.auscert.org.au/bulletins/esb-2020.1314/"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-105-04"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-003560"
},
{
"db": "NVD",
"id": "CVE-2020-7575"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-932"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2020-003560"
},
{
"db": "NVD",
"id": "CVE-2020-7575"
},
{
"db": "CNNVD",
"id": "CNNVD-202004-932"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-04-20T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-003560"
},
{
"date": "2020-04-14T20:15:15.543000",
"db": "NVD",
"id": "CVE-2020-7575"
},
{
"date": "2020-04-14T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202004-932"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2020-04-21T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2020-003560"
},
{
"date": "2021-03-04T20:26:27.443000",
"db": "NVD",
"id": "CVE-2020-7575"
},
{
"date": "2021-02-18T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202004-932"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202004-932"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Cross-site scripting vulnerabilities in multiple Siemens products",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2020-003560"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "XSS",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202004-932"
}
],
"trust": 0.6
}
}
CNVD-2020-26246
Vulnerability from cnvd - Published: 2020-05-03厂商尚未提供漏洞修复方案,请关注厂商主页更新: https://www.siemens.com/
| Name | ['Siemens Climatix POL908', 'Siemens Climatix POL909'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2020-7575"
}
},
"description": "Siemens Climatix\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u4e00\u5957\u4e13\u4e3a\u7a7a\u8c03\u3001\u5236\u51b7\u548c\u533a\u57df\u4f9b\u70edOEM\u7814\u53d1\u7684\u6807\u51c6\u5316\u548c\u53ef\u7f16\u7a0b\u63a7\u5236\u89e3\u51b3\u65b9\u6848\uff0c\u5b83\u63d0\u4f9b\u5168\u9762\u7684HVAC\u7ec4\u5408\uff0c\u53ef\u6839\u636e\u7279\u5b9a\u9700\u6c42\u8fdb\u884c\u6269\u5c55\u3002BACnet IP - POL908\u662f\u5176\u4e2d\u7684\u4e00\u4e2aBACnet IP\u901a\u4fe1\u6a21\u5757\u3002AWM Module - POL909\u662f\u5176\u4e2d\u7684\u4e00\u4e2aAWM\u901a\u4fe1\u6a21\u5757\u3002\n\nSiemens Climatix POL908\u548cPOL909\u5b58\u5728\u8de8\u7ad9\u811a\u672c\u6f0f\u6d1e\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u6ce8\u5165\u4efb\u610fJavaScript\u4ee3\u7801\uff0c\u5f71\u54cd\u5176\u4ed6\u7528\u6237Web\u4f1a\u8bdd\u7684\u4fdd\u5bc6\u6027\u548c\u5b8c\u6574\u6027\u3002",
"formalWay": "\u5382\u5546\u5c1a\u672a\u63d0\u4f9b\u6f0f\u6d1e\u4fee\u590d\u65b9\u6848\uff0c\u8bf7\u5173\u6ce8\u5382\u5546\u4e3b\u9875\u66f4\u65b0\uff1a\r\nhttps://www.siemens.com/",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2020-26246",
"openTime": "2020-05-03",
"products": {
"product": [
"Siemens Climatix POL908",
"Siemens Climatix POL909"
]
},
"referenceLink": "https://nvd.nist.gov/vuln/detail/CVE-2020-7575",
"serverity": "\u4e2d",
"submitTime": "2020-04-15",
"title": "Siemens Climatix POL908\u548cPOL909\u8de8\u7ad9\u811a\u672c\u6f0f\u6d1e\uff08CNVD-2020-26246\uff09"
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.