Action not permitted
Modal body text goes here.
cve-2021-25176
Vulnerability from cvelistv5
▼ | URL | Tags | |
---|---|---|---|
cve@mitre.org | https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf | Patch, Third Party Advisory | |
cve@mitre.org | https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf | Patch, Third Party Advisory | |
cve@mitre.org | https://www.opendesign.com/security-advisories | Vendor Advisory | |
cve@mitre.org | https://www.zerodayinitiative.com/advisories/ZDI-21-221/ | Third Party Advisory, VDB Entry | |
cve@mitre.org | https://www.zerodayinitiative.com/advisories/ZDI-21-222/ | Third Party Advisory, VDB Entry |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-03T19:56:10.730Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.opendesign.com/security-advisories" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-221/" }, { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-222/" }, { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "n/a", "vendor": "n/a", "versions": [ { "status": "affected", "version": "n/a" } ] } ], "descriptions": [ { "lang": "en", "value": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A NULL pointer dereference exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart)." } ], "problemTypes": [ { "descriptions": [ { "description": "n/a", "lang": "en", "type": "text" } ] } ], "providerMetadata": { "dateUpdated": "2022-03-08T14:06:16", "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.opendesign.com/security-advisories" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-221/" }, { "tags": [ "x_refsource_MISC" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-222/" }, { "tags": [ "x_refsource_CONFIRM" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-25176", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A NULL pointer dereference exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.opendesign.com/security-advisories", "refsource": "MISC", "url": "https://www.opendesign.com/security-advisories" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-221/", "refsource": "MISC", "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-221/" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-222/", "refsource": "MISC", "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-222/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" } ] } } } }, "cveMetadata": { "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "cveId": "CVE-2021-25176", "datePublished": "2021-01-18T07:13:46", "dateReserved": "2021-01-15T00:00:00", "dateUpdated": "2024-08-03T19:56:10.730Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-25176\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2021-01-18T08:15:13.227\",\"lastModified\":\"2022-04-08T13:20:01.937\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A NULL pointer dereference exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart).\"},{\"lang\":\"es\",\"value\":\"Se detect\u00f3 un problema en el SDK de dibujos de Open Design Alliance anterior a la versi\u00f3n 2021.11. Existe una derivaci\u00f3n de puntero nulo al renderizar archivos .DXF y .DWG malformados. Esto puede permitir a los atacantes provocar un fallo, permitiendo potencialmente un ataque de denegaci\u00f3n de servicio (Bloqueo, Salida o Reinicio)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"REQUIRED\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:P/I:P/A:P\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\",\"baseScore\":6.8},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.6,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-476\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:opendesign:drawings_software_development_kit:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2021.11\",\"matchCriteriaId\":\"DADB9784-46BC-459C-A8E3-BF688917FF31\"}]}]},{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:comos:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"10.4.1\",\"matchCriteriaId\":\"0F0CFB85-CD4F-424C-8B9F-9289D08FA665\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"13.1.0.1\",\"matchCriteriaId\":\"4FB80DF8-5E85-4072-8999-02EDA895A112\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"13.1.0.1\",\"matchCriteriaId\":\"0EB3193F-54C0-4678-A22D-A98D2134F9E7\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf\",\"source\":\"cve@mitre.org\",\"tags\":[\"Patch\",\"Third Party Advisory\"]},{\"url\":\"https://www.opendesign.com/security-advisories\",\"source\":\"cve@mitre.org\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-221/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-222/\",\"source\":\"cve@mitre.org\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}" } }
icsa-21-047-01
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "names": [ "Michael DePlante (@izobashi)", "rgod" ], "organization": "Trend Micro \u0027s Zero Day Initiative", "summary": "reporting these vulnerabilities to CISA. Siemens ProductCERT assisted coordination with Open Design Alliance" }, { "organization": "Siemens ProductCERT", "summary": "assisting coordination with Open Design Alliance" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities may allow code execution in the context of the current process or cause a denial-of-service condition.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "United States", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take the following measures to protect themselves from social engineering attacks:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage onus-cert.cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on us-cert.cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-663999: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.1.0.1 - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-663999.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-047-01 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2021/icsa-21-047-01.json" }, { "category": "self", "summary": "ICS Advisory ICSA-21-047-01 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-21-047-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ncas/tips/ST04-014" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "SSA-663999: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.1.0.1 - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf" }, { "category": "external", "summary": "SSA-663999: Multiple File Parsing Vulnerabilities in JT2Go and Teamcenter Visualization before V13.1.0.1 - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-663999.txt" } ], "title": "Open Design Alliance Drawings SDK (Update A)", "tracking": { "current_release_date": "2021-05-06T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-21-047-01", "initial_release_date": "2021-02-16T00:00:00.000000Z", "revision_history": [ { "date": "2021-02-16T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-21-047-01 Open Design Alliance Drawings SDK" }, { "date": "2021-05-06T00:00:00.000000Z", "legacy_version": "A", "number": "2", "summary": "ICSA-21-047-01 Open Design Alliance Drawings SDK (Update A)" } ], "status": "final", "version": "2" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c V13.1.0.1", "product": { "name": "JT2Go", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "JT2Go" }, { "branches": [ { "category": "product_version_range", "name": "\u003c V13.1.0.1", "product": { "name": "Teamcenter Visualization", "product_id": "CSAFPID-0002" } } ], "category": "product_name", "name": "Teamcenter Visualization" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2020-26989", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Affected applications lack proper validation of user-supplied data when parsing of PAR files. This could result in a stack based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11892)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2020-26989 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2020-26989 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-26989.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2020-26989" }, { "cve": "CVE-2020-26990", "cwe": { "id": "CWE-843", "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)" }, "notes": [ { "category": "summary", "text": "Affected applications lack proper validation of user-supplied data when parsing ASM files. A crafted ASM file could trigger a type confusion condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11897)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2020-26990 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2020-26990 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-26990.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2020-26990" }, { "cve": "CVE-2020-27000", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "Affected applications lack proper validation of user-supplied data when parsing BMP files. This can result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12018)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2020-27000 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2020-27000 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27000.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2020-27000" }, { "cve": "CVE-2020-27003", "cwe": { "id": "CWE-822", "name": "Untrusted Pointer Dereference" }, "notes": [ { "category": "summary", "text": "Affected applications lack proper validation of user-supplied data when parsing TIFF files. This could lead to pointer dereferences of a value obtained from untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12158)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2020-27003 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2020-27003 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27003.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2020-27003" }, { "cve": "CVE-2020-27004", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Affected applications lack proper validation of user-supplied data when parsing of CGM files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to access data in the context of the current process. (ZDI-CAN-12163)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2020-27004 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2020-27004 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27004.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2020-27004" }, { "cve": "CVE-2020-27005", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Affected applications lack proper validation of user-supplied data when parsing of TGA files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12178)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2020-27005 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2020-27005 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27005.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2020-27005" }, { "cve": "CVE-2020-27006", "cwe": { "id": "CWE-119", "name": "Improper Restriction of Operations within the Bounds of a Memory Buffer" }, "notes": [ { "category": "summary", "text": "Affected applications lack proper validation of user-supplied data when parsing of PCT files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12182)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2020-27006 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2020-27006 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27006.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2020-27006" }, { "cve": "CVE-2020-27007", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Affected applications lack proper validation of user-supplied data when parsing of HPG files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to access data in the context of the current process. (ZDI-CAN-12207)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2020-27007 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2020-27007 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27007.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2020-27007" }, { "cve": "CVE-2020-27008", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Affected applications lack proper validation of user-supplied data when parsing of PLT files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to access data in the context of the current process. (ZDI-CAN-12209)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2020-27008 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2020-27008 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-27008.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2020-27008" }, { "cve": "CVE-2020-28383", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Affected applications lack proper validation of user-supplied data when parsing PAR files. This can result in an out of bounds write past the memory location that is a read only image address. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-11885)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2020-28383 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2020-28383 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-28383.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2020-28383" }, { "cve": "CVE-2020-28394", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Affected applications lack proper validation of user-supplied data when parsing of RAS files. This could result in a memory access past the end of an allocated buffer. An attacker could leverage this vulnerability to access data in the context of the current process. (ZDI-CAN-12283)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2020-28394 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2020-28394 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2020-28394.json" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2020-28394" }, { "cve": "CVE-2021-25173", "cwe": { "id": "CWE-789", "name": "Memory Allocation with Excessive Size Value" }, "notes": [ { "category": "summary", "text": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.12. A memory allocation with excessive size vulnerability exists when reading malformed DGN files, which could allow attackers to cause a crash, potentially enabling denial of service (crash, exit, or restart). (ZDI-CAN-12019)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-25173 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-25173 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25173.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-25173" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-25173" }, { "cve": "CVE-2021-25174", "cwe": { "id": "CWE-789", "name": "Memory Allocation with Excessive Size Value" }, "notes": [ { "category": "summary", "text": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.12. A memory corruption vulnerability exists when reading malformed DGN files. It could allow attackers to cause a crash, potentially enabling denial of service (Crash, Exit, or Restart). (ZDI-CAN-12026)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-25174 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-25174 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25174.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-25174" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-25174" }, { "cve": "CVE-2021-25175", "cwe": { "id": "CWE-822", "name": "Untrusted Pointer Dereference" }, "notes": [ { "category": "summary", "text": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A Type Conversion issue exists when rendering malformed .DXF and .DWG files. This could allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). (ZDI-CAN-11912, ZDI-CAN-11993, ZDI-CAN-11988)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-25175 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-25175 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25175.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-25175" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-25175" }, { "cve": "CVE-2021-25176", "cwe": { "id": "CWE-822", "name": "Untrusted Pointer Dereference" }, "notes": [ { "category": "summary", "text": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A NULL pointer dereference exists when rendering malformed .DXF and .DWG files. This could allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). (ZDI-CAN-11913, ZDI-CAN-11989)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-25176 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-25176 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25176.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-25176" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-25176" }, { "cve": "CVE-2021-25177", "cwe": { "id": "CWE-843", "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)" }, "notes": [ { "category": "summary", "text": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A Type Confusion issue exists when rendering malformed .DXF and .DWG files. (ZDI-CAN-11927)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-25177 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-25177 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25177.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-25177" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-25177" }, { "cve": "CVE-2021-25178", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A stack-based buffer overflow vulnerability exists when the recover operation is run with malformed .DXF and .DWG files. (ZDI-CAN-11901, ZDI-CAN-12165, ZDI-CAN-12166)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-25178 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-25178 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25178.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-25178" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-25178" }, { "cve": "CVE-2021-31784", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "An out-of-bounds write vulnerability exists in the file-reading procedure in Open Design Alliance Drawings SDK before 2021.6.\n\nThis could allow an attacker to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart) or possible code execution. (ZDI-CAN-11915)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001", "CSAFPID-0002" ] }, "references": [ { "summary": "CVE-2021-31784 - JT2Go", "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "summary": "CVE-2021-31784 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-31784.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-31784" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://www.plm.automation.siemens.com/global/en/products/plm-components/jt2go.html" }, { "category": "vendor_fix", "details": "Update to V13.1.0.1 or later version", "product_ids": [ "CSAFPID-0002" ] }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in JT2Go and Teamcenter Visualization", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001", "CSAFPID-0002" ] } ], "title": "CVE-2021-31784" } ] }
icsa-22-069-06
Vulnerability from csaf_cisa
Notes
{ "document": { "acknowledgments": [ { "organization": "Siemens", "summary": "reporting these vulnerabilities to CISA" } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en-US", "notes": [ { "category": "general", "text": "This CSAF advisory was extracted from unstructured data and may contain inaccuracies. If you notice any errors, please reach out to the designated contact at CISA CSAF: central@cisa.dhs.gov", "title": "CISA Disclaimer" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "summary", "text": "Successful exploitation of these vulnerabilities may result in leaked information or remote code execution in the context of the current process.", "title": "Risk evaluation" }, { "category": "other", "text": "Multiple Sectors", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability. Specifically, users should:", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.\nCISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Additional mitigation guidance and recommended practices are publicly available on the ICS webpage on cisa.gov in the Technical Information Paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.\nOrganizations observing any suspected malicious activity should follow their established internal procedures and report their findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "other", "text": "No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.", "title": "Exploitability" } ], "publisher": { "category": "coordinator", "contact_details": "Email: CISAservicedesk@cisa.dhs.gov;\n Toll Free: 1-888-282-0870", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "external", "summary": "SSA-155599: File Parsing Vulnerabilities in COMOS - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-155599.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-069-06 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2022/icsa-22-069-06.json" }, { "category": "self", "summary": "ICS Advisory ICSA-22-069-06 Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-069-06" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" }, { "category": "external", "summary": "SSA-155599: File Parsing Vulnerabilities in COMOS - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" }, { "category": "external", "summary": "SSA-155599: File Parsing Vulnerabilities in COMOS - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-155599.txt" } ], "title": "Siemens COMOS", "tracking": { "current_release_date": "2022-03-10T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1.0.0" } }, "id": "ICSA-22-069-06", "initial_release_date": "2022-03-10T00:00:00.000000Z", "revision_history": [ { "date": "2022-03-10T00:00:00.000000Z", "legacy_version": "Initial", "number": "1", "summary": "ICSA-22-069-06 Siemens COMOS" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003c V10.4.1", "product": { "name": "COMOS", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "COMOS" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2021-25173", "cwe": { "id": "CWE-789", "name": "Memory Allocation with Excessive Size Value" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.12 contains a memory allocation with excessive size vulnerability while parsing specially crafted DGN files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-12019)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25173 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25173 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25173.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-25173" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25173" }, { "cve": "CVE-2021-25174", "cwe": { "id": "CWE-789", "name": "Memory Allocation with Excessive Size Value" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.12 contains a memory allocation with excessive size vulnerability while parsing specially crafted DGN files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-12026)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25174 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25174 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25174.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-25174" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25174" }, { "cve": "CVE-2021-25175", "cwe": { "id": "CWE-822", "name": "Untrusted Pointer Dereference" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.11 contains a type conversion vulnerability while parsing specially crafted DXF and DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-11912, ZDI-CAN-11993, ZDI-CAN-11988)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25175 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25175 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25175.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-25175" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25175" }, { "cve": "CVE-2021-25176", "cwe": { "id": "CWE-822", "name": "Untrusted Pointer Dereference" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.11 contains a NULL pointer dereference vulnerability while parsing DXF and DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-11913, ZDI-CAN-11989)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25176 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25176 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25176.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-25176" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25176" }, { "cve": "CVE-2021-25177", "cwe": { "id": "CWE-843", "name": "Access of Resource Using Incompatible Type (\u0027Type Confusion\u0027)" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.11 contains a type confusion issue while parsing specially crafted DXF and DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-11927)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25177 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25177 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25177.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-25177" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25177" }, { "cve": "CVE-2021-25178", "cwe": { "id": "CWE-121", "name": "Stack-based Buffer Overflow" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.11 contains a stack-based buffer overflow vulnerability while parsing specially crafted DXF or DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-11901, ZDI-CAN-12165, ZDI-CAN-12166)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-25178 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-25178 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-25178.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-25178" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-25178" }, { "cve": "CVE-2021-31784", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.6 contains an out-of-bounds write issue while parsing specially crafted DXF files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-11915)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-31784 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-31784 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-31784.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-31784" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-31784" }, { "cve": "CVE-2021-32936", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DXF files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-13408)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32936 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32936 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32936.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32936" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32936" }, { "cve": "CVE-2021-32938", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to an out-of-bounds read while parsing specially crafted DWG files. This could allow an attacker to read sensitive information from memory locations and to cause a denial of service (crash). (ZDI-CAN-13378)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32938 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32938 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32938.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32938" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32938" }, { "cve": "CVE-2021-32940", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to an out-of-bounds read while parsing specially crafted DWG files. This could allow an attacker to read sensitive information from memory locations and to cause a denial of service. (ZDI-CAN-13412)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32940 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32940 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32940.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32940" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32940" }, { "cve": "CVE-2021-32944", "cwe": { "id": "CWE-416", "name": "Use After Free" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2021.11 contains a use-after-free vulnerability while parsing specially crafted DGN files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-13468, ZDI-CAN-13413)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32944 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32944 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32944.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32944" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32944" }, { "cve": "CVE-2021-32946", "cwe": { "id": "CWE-754", "name": "Improper Check for Unusual or Exceptional Conditions" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to improper check for unusual or exceptional conditions while parsing specially crafted DGN files. This could allow an attacker to cause a denial-of-service condition or execute code in the context of the current process. (ZDI-CAN-13411, ZDI-CAN-13409)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32946 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32946 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32946.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32946" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32946" }, { "cve": "CVE-2021-32948", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DWG files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-13410)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32948 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32948 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32948.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32948" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32948" }, { "cve": "CVE-2021-32950", "cwe": { "id": "CWE-125", "name": "Out-of-bounds Read" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 are vulnerable to an out-of-bounds read while parsing specially crafted DXF files. This could allow an attacker to read sensitive information from memory locations and to cause a denial of service. (ZDI-CAN-13415)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32950 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32950 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32950.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32950" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.1, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32950" }, { "cve": "CVE-2021-32952", "cwe": { "id": "CWE-787", "name": "Out-of-bounds Write" }, "notes": [ { "category": "summary", "text": "Open Design Alliance Drawings SDK before 2022.4 contains an out-of-bounds write issue while parsing specially crafted DGN files. This could result in a write past the end of an allocated buffer and allow an attacker to execute code in the context of the current process. (ZDI-CAN-13417)", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "references": [ { "summary": "CVE-2021-32952 - COMOS", "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "summary": "CVE-2021-32952 Mitre 5.0 json", "url": "https://cert-portal.siemens.com/productcert/mitre/CVE-2021-32952.json" }, { "category": "external", "summary": "web.nvd.nist.gov", "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnId=CVE-2021-32952" }, { "category": "external", "summary": "www.first.org", "url": "https://www.first.org/cvss/calculator/3.0#CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H" } ], "remediations": [ { "category": "vendor_fix", "details": "Update to V10.4.1 or later version", "product_ids": [ "CSAFPID-0001" ], "url": "https://support.industry.siemens.com/cs/ww/en/view/109805632/" }, { "category": "mitigation", "details": "Avoid to open untrusted files from unknown sources in COMOS", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\n\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2021-32952" } ] }
gsd-2021-25176
Vulnerability from gsd
{ "GSD": { "alias": "CVE-2021-25176", "description": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A NULL pointer dereference exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart).", "id": "GSD-2021-25176" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2021-25176" ], "details": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A NULL pointer dereference exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart).", "id": "GSD-2021-25176", "modified": "2023-12-13T01:23:21.360132Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-25176", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "n/a", "version": { "version_data": [ { "version_value": "n/a" } ] } } ] }, "vendor_name": "n/a" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A NULL pointer dereference exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "n/a" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.opendesign.com/security-advisories", "refsource": "MISC", "url": "https://www.opendesign.com/security-advisories" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-221/", "refsource": "MISC", "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-221/" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-222/", "refsource": "MISC", "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-222/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf", "refsource": "CONFIRM", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" } ] } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:opendesign:drawings_software_development_kit:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2021.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:comos:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "10.4.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "13.1.0.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "13.1.0.1", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "cve@mitre.org", "ID": "CVE-2021-25176" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A NULL pointer dereference exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart)." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-476" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.opendesign.com/security-advisories", "refsource": "MISC", "tags": [ "Vendor Advisory" ], "url": "https://www.opendesign.com/security-advisories" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf", "refsource": "CONFIRM", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-221/", "refsource": "MISC", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-221/" }, { "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-222/", "refsource": "MISC", "tags": [ "Third Party Advisory", "VDB Entry" ], "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-222/" }, { "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf", "refsource": "CONFIRM", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" } ] } }, "impact": { "baseMetricV2": { "acInsufInfo": false, "cvssV2": { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "integrityImpact": "PARTIAL", "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, "exploitabilityScore": 8.6, "impactScore": 6.4, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "userInteractionRequired": true }, "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 5.9 } }, "lastModifiedDate": "2022-04-08T13:20Z", "publishedDate": "2021-01-18T08:15Z" } } }
var-202101-1899
Vulnerability from variot
An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A NULL pointer dereference exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). Open Design Alliance Drawings SDK Has NULL A pointer dereference vulnerability exists.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of DXF files. The issue results from the lack of proper validation of a user-supplied value prior to dereferencing it as a pointer. An attacker can leverage this vulnerability to execute code in the context of the current process. The development kit accesses the data in .dwg and .dgn through a convenient, object-oriented API, and provides functions such as C++ API, support for repairing files, and support for .NET, JAVA, and Python development languages
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202101-1899", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "jt2go", "scope": null, "trust": 1.4, "vendor": "siemens", "version": null }, { "model": "drawings software development kit", "scope": "lt", "trust": 1.0, "vendor": "opendesign", "version": "2021.11" }, { "model": "teamcenter visualization", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "13.1.0.1" }, { "model": "jt2go", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "13.1.0.1" }, { "model": "comos", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "10.4.1" }, { "model": "teamcenter visualization", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null }, { "model": "drawings sdk", "scope": null, "trust": 0.8, "vendor": "open design alliance", "version": null }, { "model": "jt2go", "scope": null, "trust": 0.8, "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9", "version": null } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-222" }, { "db": "ZDI", "id": "ZDI-21-221" }, { "db": "JVNDB", "id": "JVNDB-2021-002747" }, { "db": "NVD", "id": "CVE-2021-25176" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:opendesign:drawings_software_development_kit:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2021.11", "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:siemens:comos:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "10.4.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:jt2go:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "13.1.0.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:siemens:teamcenter_visualization:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "13.1.0.1", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-25176" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "rgod", "sources": [ { "db": "ZDI", "id": "ZDI-21-222" } ], "trust": 0.7 }, "cve": "CVE-2021-25176", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "impactScore": 6.4, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": true, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Partial", "baseScore": 6.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2021-25176", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.9, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "PARTIAL", "baseScore": 6.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "VHN-383905", "impactScore": 6.4, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:P", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "ZDI", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2021-25176", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.4, "userInteraction": "REQUIRED", "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2021-25176", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-25176", "trust": 1.8, "value": "HIGH" }, { "author": "ZDI", "id": "CVE-2021-25176", "trust": 1.4, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202101-1316", "trust": 0.6, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-383905", "trust": 0.1, "value": "MEDIUM" }, { "author": "VULMON", "id": "CVE-2021-25176", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-222" }, { "db": "ZDI", "id": "ZDI-21-221" }, { "db": "VULHUB", "id": "VHN-383905" }, { "db": "VULMON", "id": "CVE-2021-25176" }, { "db": "JVNDB", "id": "JVNDB-2021-002747" }, { "db": "NVD", "id": "CVE-2021-25176" }, { "db": "CNNVD", "id": "CNNVD-202101-1316" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A NULL pointer dereference exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). Open Design Alliance Drawings SDK Has NULL A pointer dereference vulnerability exists.Information is obtained, information is tampered with, and service is disrupted (DoS) It may be put into a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens JT2Go. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of DXF files. The issue results from the lack of proper validation of a user-supplied value prior to dereferencing it as a pointer. An attacker can leverage this vulnerability to execute code in the context of the current process. The development kit accesses the data in .dwg and .dgn through a convenient, object-oriented API, and provides functions such as C++ API, support for repairing files, and support for .NET, JAVA, and Python development languages", "sources": [ { "db": "NVD", "id": "CVE-2021-25176" }, { "db": "JVNDB", "id": "JVNDB-2021-002747" }, { "db": "ZDI", "id": "ZDI-21-222" }, { "db": "ZDI", "id": "ZDI-21-221" }, { "db": "VULHUB", "id": "VHN-383905" }, { "db": "VULMON", "id": "CVE-2021-25176" } ], "trust": 3.06 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-25176", "trust": 4.0 }, { "db": "ZDI", "id": "ZDI-21-222", "trust": 3.3 }, { "db": "ZDI", "id": "ZDI-21-221", "trust": 3.3 }, { "db": "SIEMENS", "id": "SSA-663999", "trust": 1.8 }, { "db": "SIEMENS", "id": "SSA-155599", "trust": 1.7 }, { "db": "ICS CERT", "id": "ICSA-21-047-01", "trust": 1.4 }, { "db": "JVN", "id": "JVNVU92291213", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-002747", "trust": 0.8 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-11989", "trust": 0.7 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-11913", "trust": 0.7 }, { "db": "CNNVD", "id": "CNNVD-202101-1316", "trust": 0.7 }, { "db": "AUSCERT", "id": "ESB-2022.1047", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2021.0577", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-21-040-06", "trust": 0.6 }, { "db": "ICS CERT", "id": "ICSA-22-069-06", "trust": 0.6 }, { "db": "CS-HELP", "id": "SB2022031102", "trust": 0.6 }, { "db": "VULHUB", "id": "VHN-383905", "trust": 0.1 }, { "db": "VULMON", "id": "CVE-2021-25176", "trust": 0.1 } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-222" }, { "db": "ZDI", "id": "ZDI-21-221" }, { "db": "VULHUB", "id": "VHN-383905" }, { "db": "VULMON", "id": "CVE-2021-25176" }, { "db": "JVNDB", "id": "JVNDB-2021-002747" }, { "db": "NVD", "id": "CVE-2021-25176" }, { "db": "CNNVD", "id": "CNNVD-202101-1316" } ] }, "id": "VAR-202101-1899", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-383905" } ], "trust": 0.25799868000000004 }, "last_update_date": "2023-12-18T10:51:11.320000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Siemens has issued an update to correct this vulnerability.", "trust": 1.4, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-06" }, { "title": "Vulnerabilities\u00a0in\u00a0the\u00a0ODA\u00a0Drawings\u00a0Software\u00a0Development\u00a0Kit Siemens Siemens\u00a0Security\u00a0Advisory", "trust": 0.8, "url": "https://www.opendesign.com/security-advisories" }, { "title": "Open Design Alliance Drawings SDK Fixes for code issue vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=139575" }, { "title": "Siemens Security Advisories: Siemens Security Advisory", "trust": 0.1, "url": "https://vulmon.com/vendoradvisory?qidtp=siemens_security_advisories\u0026qid=1c3bdb36e22f42f5b9339f0ff806382c" } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-222" }, { "db": "ZDI", "id": "ZDI-21-221" }, { "db": "VULMON", "id": "CVE-2021-25176" }, { "db": "JVNDB", "id": "JVNDB-2021-002747" }, { "db": "CNNVD", "id": "CNNVD-202101-1316" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-476", "trust": 1.1 }, { "problemtype": "NULL Pointer dereference (CWE-476) [NVD Evaluation ]", "trust": 0.8 } ], "sources": [ { "db": "VULHUB", "id": "VHN-383905" }, { "db": "JVNDB", "id": "JVNDB-2021-002747" }, { "db": "NVD", "id": "CVE-2021-25176" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.7, "url": "https://www.zerodayinitiative.com/advisories/zdi-21-222/" }, { "trust": 2.6, "url": "https://www.zerodayinitiative.com/advisories/zdi-21-221/" }, { "trust": 2.0, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-06" }, { "trust": 1.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf" }, { "trust": 1.8, "url": "https://www.opendesign.com/security-advisories" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2021-25176" }, { "trust": 1.4, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-047-01" }, { "trust": 0.8, "url": "http://jvn.jp/vu/jvnvu92291213/index.html" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2022.1047" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2021.0577" }, { "trust": 0.6, "url": "https://www.cybersecurity-help.cz/vdb/sb2022031102" }, { "trust": 0.6, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-069-06" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/476.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-222" }, { "db": "ZDI", "id": "ZDI-21-221" }, { "db": "VULHUB", "id": "VHN-383905" }, { "db": "VULMON", "id": "CVE-2021-25176" }, { "db": "JVNDB", "id": "JVNDB-2021-002747" }, { "db": "NVD", "id": "CVE-2021-25176" }, { "db": "CNNVD", "id": "CNNVD-202101-1316" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "ZDI", "id": "ZDI-21-222" }, { "db": "ZDI", "id": "ZDI-21-221" }, { "db": "VULHUB", "id": "VHN-383905" }, { "db": "VULMON", "id": "CVE-2021-25176" }, { "db": "JVNDB", "id": "JVNDB-2021-002747" }, { "db": "NVD", "id": "CVE-2021-25176" }, { "db": "CNNVD", "id": "CNNVD-202101-1316" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-02-24T00:00:00", "db": "ZDI", "id": "ZDI-21-222" }, { "date": "2021-02-24T00:00:00", "db": "ZDI", "id": "ZDI-21-221" }, { "date": "2021-01-18T00:00:00", "db": "VULHUB", "id": "VHN-383905" }, { "date": "2021-01-18T00:00:00", "db": "VULMON", "id": "CVE-2021-25176" }, { "date": "2021-09-29T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-002747" }, { "date": "2021-01-18T08:15:13.227000", "db": "NVD", "id": "CVE-2021-25176" }, { "date": "2021-01-18T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-1316" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-02-24T00:00:00", "db": "ZDI", "id": "ZDI-21-222" }, { "date": "2021-02-24T00:00:00", "db": "ZDI", "id": "ZDI-21-221" }, { "date": "2022-04-08T00:00:00", "db": "VULHUB", "id": "VHN-383905" }, { "date": "2021-03-04T00:00:00", "db": "VULMON", "id": "CVE-2021-25176" }, { "date": "2021-09-29T08:26:00", "db": "JVNDB", "id": "JVNDB-2021-002747" }, { "date": "2022-04-08T13:20:01.937000", "db": "NVD", "id": "CVE-2021-25176" }, { "date": "2022-03-14T00:00:00", "db": "CNNVD", "id": "CNNVD-202101-1316" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-1316" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Siemens JT2Go DXF File Parsing Untrusted Pointer Dereference Remote Code Execution Vulnerability", "sources": [ { "db": "ZDI", "id": "ZDI-21-222" }, { "db": "ZDI", "id": "ZDI-21-221" } ], "trust": 1.4 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "code problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-202101-1316" } ], "trust": 0.6 } }
ghsa-j2rh-4mpc-95mq
Vulnerability from github
An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A NULL pointer dereference exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). This is issue 2 of 3.
{ "affected": [], "aliases": [ "CVE-2021-25176" ], "database_specific": { "cwe_ids": [ "CWE-476" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2021-01-18T08:15:00Z", "severity": "MODERATE" }, "details": "An issue was discovered in Open Design Alliance Drawings SDK before 2021.11. A NULL pointer dereference exists when rendering malformed .DXF and .DWG files. This can allow attackers to cause a crash, potentially enabling a denial of service attack (Crash, Exit, or Restart). This is issue 2 of 3.", "id": "GHSA-j2rh-4mpc-95mq", "modified": "2022-05-24T17:39:25Z", "published": "2022-05-24T17:39:25Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-25176" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-155599.pdf" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-663999.pdf" }, { "type": "WEB", "url": "https://www.opendesign.com/security-advisories" }, { "type": "WEB", "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-221" }, { "type": "WEB", "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-222" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "type": "CVSS_V3" } ] }
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.