This vulnerability allows a firewall bypass on affected installations of TP-Link Archer A7 prior to Archer C7(US)_V5_210125 and Archer A7(US)_V5_200220 AC1750 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of IPv6 connections. The issue results from the lack of proper filtering of IPv6 SSH connections. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-12309.
Severity ?
8.1 (High)
CWE
- CWE-693 - Protection Mechanism Failure
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
Credits
Team FLASHBACK: Pedro Ribeiro (@pedrib1337 | pedrib@gmail.com) + Radek Domanski (@RabbitPro)
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:48:15.952Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-214/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Archer A7",
"vendor": "TP-Link",
"versions": [
{
"status": "affected",
"version": "prior to Archer C7(US)_V5_210125 and Archer A7(US)_V5_200220"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Team FLASHBACK: Pedro Ribeiro (@pedrib1337 | pedrib@gmail.com) + Radek Domanski (@RabbitPro)"
}
],
"descriptions": [
{
"lang": "en",
"value": "This vulnerability allows a firewall bypass on affected installations of TP-Link Archer A7 prior to Archer C7(US)_V5_210125 and Archer A7(US)_V5_200220 AC1750 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of IPv6 connections. The issue results from the lack of proper filtering of IPv6 SSH connections. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-12309."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-693",
"description": "CWE-693: Protection Mechanism Failure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-29T21:05:33",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-214/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"ID": "CVE-2021-27245",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Archer A7",
"version": {
"version_data": [
{
"version_value": "prior to Archer C7(US)_V5_210125 and Archer A7(US)_V5_200220"
}
]
}
}
]
},
"vendor_name": "TP-Link"
}
]
}
},
"credit": "Team FLASHBACK: Pedro Ribeiro (@pedrib1337 | pedrib@gmail.com) + Radek Domanski (@RabbitPro)",
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "This vulnerability allows a firewall bypass on affected installations of TP-Link Archer A7 prior to Archer C7(US)_V5_210125 and Archer A7(US)_V5_200220 AC1750 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of IPv6 connections. The issue results from the lack of proper filtering of IPv6 SSH connections. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-12309."
}
]
},
"impact": {
"cvss": {
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-693: Protection Mechanism Failure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-21-214/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-21-214/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2021-27245",
"datePublished": "2021-03-29T21:05:33",
"dateReserved": "2021-02-16T00:00:00",
"dateUpdated": "2024-08-03T20:48:15.952Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:tp-link:archer_a7_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"c7\\\\(us\\\\)_v5_210125\", \"matchCriteriaId\": \"63702440-447F-40AF-84B9-CAE8DF07F990\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:tp-link:archer_a7:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8436480B-77AE-4910-AD80-2AC21F36992A\"}]}]}, {\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:tp-link:archer_a7_firmware:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"a7\\\\(us\\\\)_v5_200220\", \"matchCriteriaId\": \"F767618F-6E2D-4BCC-BAAD-5DC3EF8BC4B0\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:tp-link:archer_a7:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8436480B-77AE-4910-AD80-2AC21F36992A\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"This vulnerability allows a firewall bypass on affected installations of TP-Link Archer A7 prior to Archer C7(US)_V5_210125 and Archer A7(US)_V5_200220 AC1750 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of IPv6 connections. The issue results from the lack of proper filtering of IPv6 SSH connections. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-12309.\"}, {\"lang\": \"es\", \"value\": \"Esta vulnerabilidad permite una omisi\\u00f3n del firewall en las instalaciones afectadas de TP-Link Archer A7 antes de los enrutadores Archer C7(EE. UU.)_V5_210125 y Archer A7(EE. UU.)_V5_200220 AC1750.\u0026#xa0;No es requerida una autenticaci\\u00f3n para explotar esta vulnerabilidad.\u0026#xa0;El fallo espec\\u00edfico se presenta dentro del manejo de las conexiones IPv6.\u0026#xa0;El problema resulta de una falta de filtrado apropiado de las conexiones SSH IPv6.\u0026#xa0;Un atacante puede aprovechar esto junto con otras vulnerabilidades para ejecutar c\\u00f3digo en el contexto de root.\u0026#xa0;Era ZDI-CAN-12309\"}]",
"id": "CVE-2021-27245",
"lastModified": "2024-11-21T05:57:40.570",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.1, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.2, \"impactScore\": 5.9}], \"cvssMetricV30\": [{\"source\": \"zdi-disclosures@trendmicro.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.1, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.2, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:N/C:C/I:C/A:C\", \"baseScore\": 9.3, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 8.6, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
"published": "2021-03-29T21:15:12.953",
"references": "[{\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-21-214/\", \"source\": \"zdi-disclosures@trendmicro.com\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}, {\"url\": \"https://www.zerodayinitiative.com/advisories/ZDI-21-214/\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\", \"VDB Entry\"]}]",
"sourceIdentifier": "zdi-disclosures@trendmicro.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"zdi-disclosures@trendmicro.com\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-693\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2021-27245\",\"sourceIdentifier\":\"zdi-disclosures@trendmicro.com\",\"published\":\"2021-03-29T21:15:12.953\",\"lastModified\":\"2024-11-21T05:57:40.570\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"This vulnerability allows a firewall bypass on affected installations of TP-Link Archer A7 prior to Archer C7(US)_V5_210125 and Archer A7(US)_V5_200220 AC1750 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of IPv6 connections. The issue results from the lack of proper filtering of IPv6 SSH connections. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-12309.\"},{\"lang\":\"es\",\"value\":\"Esta vulnerabilidad permite una omisi\u00f3n del firewall en las instalaciones afectadas de TP-Link Archer A7 antes de los enrutadores Archer C7(EE. UU.)_V5_210125 y Archer A7(EE. UU.)_V5_200220 AC1750.\u0026#xa0;No es requerida una autenticaci\u00f3n para explotar esta vulnerabilidad.\u0026#xa0;El fallo espec\u00edfico se presenta dentro del manejo de las conexiones IPv6.\u0026#xa0;El problema resulta de una falta de filtrado apropiado de las conexiones SSH IPv6.\u0026#xa0;Un atacante puede aprovechar esto junto con otras vulnerabilidades para ejecutar c\u00f3digo en el contexto de root.\u0026#xa0;Era ZDI-CAN-12309\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":5.9}],\"cvssMetricV30\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:C/I:C/A:C\",\"baseScore\":9.3,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.6,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-693\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:tp-link:archer_a7_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"c7\\\\(us\\\\)_v5_210125\",\"matchCriteriaId\":\"63702440-447F-40AF-84B9-CAE8DF07F990\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:tp-link:archer_a7:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8436480B-77AE-4910-AD80-2AC21F36992A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:tp-link:archer_a7_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"a7\\\\(us\\\\)_v5_200220\",\"matchCriteriaId\":\"F767618F-6E2D-4BCC-BAAD-5DC3EF8BC4B0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:tp-link:archer_a7:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8436480B-77AE-4910-AD80-2AC21F36992A\"}]}]}],\"references\":[{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-214/\",\"source\":\"zdi-disclosures@trendmicro.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-21-214/\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…